Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Similar documents
Model Sono-Trak General Specification

OPERATING INSTRUCTIONS

Series DMHF Heat Meter

Series TFXD FIXED LOCATION TRANSIT TIME FLOW METER FEATURES

SITRANS F flowmeters SITRANS F US

Clamp-On Transit Time Ultrasonic Flow Meters

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

Series TFXP PORTABLE TRANSIT TIME FLOW METER FEATURES

Ultrasonic Flow Meter Brochure

Ultra Sonic Flowmeter DATASHEET

UTM10 Series Ultrasonic Transit-time Flowmeters

Ultrasonic Heat Flow Meters

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

DMTFP Portable Ultrasonic Flow Meters

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Clamp-on

DCT7088 Portable Digital Correlation Transit Time Flowmeter

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

AG3000 SERIES FLANGED MAGMETER

imag 4700 Series FLANGED MAGMETER

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co.

Flow Measurement SITRANS F US Clamp-on

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

AG3000 SERIES FLANGED MAGMETER

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

imag 4700 Series FLANGED MAGMETER

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

Level and Flow Measurement. Flow Pulse

Sono-Trak Operation & Maintenance Manual

Track fluid flow from outside the pipe

PanaFlow Gas Meter System

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level-Lance Model 5400A

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level and Flow Measurement. Flow Pulse

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

imag-series Flanged Magmeter

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

TPE 1464 Series Pressure Transducer

Flow Measurement SITRANS F US Clamp-on

ThermoPro TM Series TP10

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

MAG. ECO FLO imag Series NSF FEATURES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

SITRANS L Level instruments

Universal IV Water Cut Meter

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

DMT345 and DMT346 Dewpoint Transmitters

Applications. Features And Benefits. Ultrasonic Transit-Time Flowmeter For Permanent Installation

Conductivity Transmitters

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

MMT330 Series Moisture and Temperature Transmitters for Oil

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

OPTISONIC 6400 Technical Datasheet

Family of Water Cut Analyzers

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Submersible Liquid Level Transmitter Series: PT-500

Digital O.R.P. Transmitter Type 8206

DIN-Rail Mounted Ultrasonic Flow Meter

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

Model FP-100 General Specification

Ultra CLAMP-ON ULTRASONIC FLOW AND ENERGY METERS FOR LIQUIDS. dynasonics.com

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Signet 2552 Metal Magmeter Flow Sensors

Gladiator Acoustic Switch Series

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Welcome to the Webinar

CDD4 Duct Carbon Dioxide Transmitter

TFX Ultra CLAMP-ON ULTRASONIC FLOW AND ENERGY METERS FOR LIQUIDS BENEFITS FEATURES

Variable Area Flowmeter DATASHEET

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

Flow Measurement SITRANS F US Clamp-on

Transcription:

A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic technology. This easy-to-install and easy-to-program system provides the ideal solution for low-cost, reliable, and maintenance-free measurement. Benefits Fast and easy installation Rugged and maintenance-free with no moving parts Fits pipe sizes from 2 to 100 (50 to 2540 mm) Non-invasive, bi-directional measurement Reliable and accurate readings provides ±2.0% of rate accuracy and ±0.1% repeatability Features Simple, clamp-on design Time domain expansion technology used to increase resolution Flexible, field-programmable EZ-Logic user interface NEMA 6-rated transducer housings Flexible module I/O design Built-in infrared capability for optional PC interface Applications Ideally suited for: Deionized water Ultrapure water General water Acids Solvents Overview The Sono-Trak Transit Time meter delivers performance excellence in a non-invasive, bi-directional, ultrasonic metering system. Consisting of simple, clamp-on transducers and a menu-driven programmable display, the system eliminates mechanical wear, drift, and pressure drop problems associated with traditional technologies making it the ideal choice for new installations and system retrofits. This exceptionally compatible, reliable, and accurate metering solution is suitable for clean, swirl-free liquids in most industrial applications. Compatible and Reliable The Sono-Trak Transit Time meter fits pipe sizes from 2 to 100 (50 to 2540 mm) and accommodates a wide variety of pipe materials. In addition, it can sustain high-temperature and high-pressure conditions. With no orifice plates or other moving parts to wear, recalibrate, or maintain, the Sono-Trak Transit Time meter offers ±0.1% of rate repeatability. Non-contact fluid measurement not only allows installation during, but also eliminates chemical corrosion, caking, and risk of fluid contamination. Highly Accurate The Sono-Trak Transit Time meter uses advanced ultrasonic technology for accurate measurement. Transducers operate as both transmitter and receiver of signals, with one transducer upstream and one downstream. By taking bi-directional measurement transmitting high-frequency sound waves through the pipe into the stream in both directions the electronics determine the difference in time (transit time) of the upstream and downstream signals. Advanced digital signal processing translates the transit time and calculates the average fluid velocity delivering ± 2.0% of rate accuracy in a typical field installation. Response time is user selectable from 0.3 to 30 seconds. 72 Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification.

Display Module An easy-to-program, wall-mounted display employs fieldprogrammable EZ-Logic software. The default data output alternates between continuous, real-time rate readings and total readings shown in English and Metric user-selectable engineering units. With buffet-style input/output (I/O) module options, the electronics configuration is easily customized. Two I/O sockets will accept multiple modules, including pulse, analog, relay, RS-232, or RS-485. To streamline configuration, a built-in infrared communication port is available with optional Windows -compatible software, allowing multiple meters to be programmed with a personal computer. Sono-Trak Transit Time Optional Input/Output Modules Custom electronics configuration is made possible through multiple I/O module options: 4 to 20 ma Output Field configurable as a 2-wire active or passive transmitter, 800 Ω maximum resistance Frequency Output Open collector, field configurable for 0 to1000 Hz or 0 to 10,000 Hz output Dual Relay Output Used for batching, high/low alarms, empty pipe detection, and error indication RS-232 Communication Used to monitor information RS-485 Communication Used to network up to 100 units together in a master/slave configuration Signal moving upstream Upstream velocity = speed of sound - fluid velocity Signal moving downstream Downstream velocity = speed of sound + fluid velocity Installation Considerations Transducer Mounting The Sono-Trak Transit Time meter s non-invasive design uses stainless steel quick clamps and heavy-duty cables that are preterminated to facilitate fast and easy installation. The transducers mount on the outside of a process pipe with one transducer upstream and one downstream. Installation is non-intrusive as no sensor is inserted into the pipe. Transducer spacing is dependent upon pipe size and is calculated automatically during set-up. Straight run requirements are typically 10 diameters upstream and 5 diameters downstream. Accurate results may be achieved with straight run of 5 diameters upstream and 3 diameters downstream. Upstream valves and other piping configurations may require more straight run. Vertical Pipe Mounting The recommended direction in a vertical pipe is upwards. correct incorrect Horizontal Pipe Mounting Transducer should be mounted on a horizontal pipe as shown. correct incorrect 73

Zero Point Adjustment For best accuracy, a zero point setting must be made with a full pipe at no during initial start-up. Air/Gas Entrapment Excess gas entrapment can scatter or reflect the sound wave, causing inaccurate measurement. Allowable air/gas entrapment is 2%. Pipe Material The property of the pipe material can affect the performance of the meter. Good Results Caution Needed Do Not Use On Most metallic Cast iron Cement Plastic Lined pipes Pipes with internal deposits or severe corrosion Sonic Wave Forms To obtain the best possible signal strength, the following mounting options are recommended: 2 to 2.5 (DN50 to DN65) = W 3 to 12 (DN80 to DN300) = V 14 to 100 (DN350 to DN2500) = Z W V Z Cabling The Sono-Trak Transit Time includes a standard cable length of 25 (76 m) and optional lengths of 50 (15.2 m) and 75 (22.8 m). Custom cable lengths of 76 to 1000 (23.1 to 304.8 m) are also available. 74

Specifications Performance Accuracy Factory tested at ±0.5% of rate. 1 Typical field installation is ±2.0% of rate. Field performance is dependant on the accuracy of the pipe s internal diameter and wall thickness measurements as well as straight run conditions. Repeatability Response Time ±0.1% of rate Adjustable from.3 to 30 seconds 1 Factory test conditions: water at 70 F (21 C), velocity > 1 ft/sec on a 6 stainless steel pipe Physical Materials Wetted parts None Electronics housing Transducer housing Reinforced polycarbonate with stainless steel hardware NEMA 4X (IP65) 400 F (204 C): Torlon /Vespel /Stainless Steel; NEMA 6 (IP68) 250 F (121 C): Delrin /Ultem /Stainless Steel; NEMA 6 (IP68) Sensor cables Clamps Polyurethane armored coaxial Stainless Steel Cable Lengths Standard 25' (7.6 m) Options 50' (15.2 m) 75' (22.8 m) Custom 76 to 1000' (23.1 to 304.8 m) Weight Electronics 4.5 lb (2 kg) Transducers 4.5 lb (2.05 kg) for two transducers with 25' (7.6 m) of cable Size Electronics 7" (H) x 7" (W) x 5" (D) 177.8 mm (H) x 177.8 mm (W) x 127 mm (D) Transducer 2" (H) x 3.25" (W) x 1.45" (D) 50.8 mm (H) x 82.6 mm (W) x 36.8 mm (D) Maximum Transducer Cable Length 1000' (304.8 m) Cable Connection Standard submersible Mounting Electronics Remote wall Transducer External, adjustable clamp CSA Approval Class I Div II Groups A, B, C, D Class II and Class III Groups E, F 75

Specifications (continued) Operating Specifications Applied Pipeline Sizes Measurable Fluids Measurable Flow Velocities Ambient Temperature Limit 2 to 100" (50 to 2540 mm) Most common liquids from waste water to petrochemical products Liquid -40 to 40 ft/sec (-12 to12 m/sec) -40 to 140ºF (-40 to 60ºC) Process Temperature Limit Standard -40 to 250ºF (-40 to120ºc) High temp option -40 to 400ºF (-40 to 205ºC) Ambient Humidity Limit Process Pressure Limit Power Requirements Up to 95% RH, non-condensing Not applicable Field configurable for AC or DC operation Power Consumption 12 to 24 VDC 115 VAC, 50/60 Hz (± 10%) 230 VAC, 50/60 Hz (± 10%) > 5 W Input/Output Modules A maximum of two outputs can be selected. All input/output modules are optically isolated up to 2,500 V against ground loops and electrical surges. 4 to 20 ma Output Field configurable as a 2-wire active or passive transmitter, 800 Ω maximum resistance Frequency Output Dual Relay Output RS485 Interface RS232 Interface Open collector, field configurable for 0 to 1000 Hz or 0 to 10,000 Hz output, 20 ma maximum (50% of duty cycle) Two SPDT form C contacts independently controlled; 175 V, ¼ A switch, 1 A carry current, 0.2 Ω resistance. Used for batching, high/low alarms, empty pipe detection, and error indication Used to network up to 100 units together in a master/slave configuration using built-in software and communications protocol. Supports 57.6 kb communications, up to 1000' (304.8 m) Used to monitor information. Supports up to 57.6 kb communications, (19.2 kb @ 50') Standard Interface LCD backlit display with 8-character large numeric and 8-character small alphanumeric. Four button menu-driven EZ-Logic interface for programming Flow Units English units User-selectable from gallons, cubic feet, millions of gallons, oil barrels, liquid barrels, feet, and pounds. Note: Gallons refers to U.S. Gallons. Metric units Liters, meters, cubic meters, and kilograms Time Units User-selectable from seconds, minutes, hours and days 76

Model Selection Category Electronics 2-line backlit display with 4-button keypad I/O Port 1 None Suffix Codes ST-30 4-20 ma output A Frequency output Dual relay output (dry contact) RS-232 interface RS-485 interface I/O Port 2 None N F R RS2 RS4 4-20 ma output A Frequency output Dual relay output (dry contact) RS-232 interface RS-485 interface Process Temperature N F R RS2 RS4-40 to 250ºF (-40 to 120ºC) 250-40 to 400ºF (-40 to 205ºC) 400 Transducers Submersible 1 Cable Length (specify length) 25' (7.6 m) 25 50' (15.2 m) 50 75' (22.8 m) 75 76 to 1000' (23.1 to 304.8 m) xx Pipe Clamp (specify pipe size) 2 to 12" (50 to 300 mm) 12 14 to 24" (350 to 600 mm) 24 26 to 36" (650 to 900 mm) 36 38 to 100" (950 to 2540 mm) xx Example ST-30- A- N- 250-1- 25-12 Accessories Description Part Number Windows communication software for IR Port/RS232/RS485 modules 6001100 Infrared serial communicator for wireless PC interface 1-800-138 Transducer cable conduit adapter ¾" NPT (requires 2 pieces) 340790 Low temp transducer and 25' of cable -40 to 250ºF (-40 to 120ºC)* 011143-125 High temp transducer and 25' of cable -40 to 400ºF (-40 to 205ºC)* 011143-225 * If a pair of transducers is required, two units of the same part number must be ordered. 77