SPECIFICATIONS FOR RIBBON FIBER FUSION SPLICER 70R+

Similar documents
SPECIFICATIONS FOR RIBBON FIBER FUSION SPLICER 70R TENTATIVE

SPECIFICATIONS FOR SINGLE FIBER FUSION SPLICER 19S TENTATIVE

SPECIFICATIONS FOR SINGLE FIBER FUSION SPLICER 62S

Single Fiber Arc Fusion Splicer FSM 60S

FUSION SPLICING SYSTEMS. Fusion Splicers Cleavers Tools & Supplies Software

FSM-50S. New standard. New model. Just released! Optical Fiber Fusion Splicer. Provided by

FUSION SPLICING SYSTEMS. Fusion Splicers Cleavers Tools & Supplies Software

Table of Contents. Field Fusion Splicing Equipment. Specialty Fusion Splicing Equipment

FSM-30PF SPECIFICATIONS FOR FIBER FUSION SPLICER FOR HIGH TENSILE STRENGTH SPLICING 1. GENERAL

SPECIFICATION FOR FIBEROPTIC.COM TACTICAL FUSION SPLICER

High Precision Fusion Splicer

INNO Instrument Inc. Ver Copyright c 2014 INNO Instrument Inc. All rights reserved.

+ + Swift F1+ is a way on future splicers.

S178A. Hand-Held Core-Alignment Fusion Splicer

SKYCOM Fusion Splicer

S178 ver.2 Fusion Splicers Hand-Held Core-Alignment Fusion Splicer

Fitel Ninja NJ001 Handheld, Single Fiber Fusion Splicer

RoHS. OptiSplice One Handheld Fusion Splicer A LANscape Pretium Solutions Product. Corning Cable Systems

S153 v2 Fusion Splicers Hand-Held Active Alignment Fusion Splicer

ООО "Техэнком" Контрольно-измерительные приборы и оборудование Instruction manual

Products & SOLUTIONS Full-Line Product Catalog. Splicing Equipment. Test Equipment. Consumables & Tools. Cable Connectivity.

features and benefits

features and benefits

All-In-One Fusion Splicer

Products & SOLUTIONS. Full-Line Product Catalog. Splicing Equipment. Test Equipment. Consumables & Tools. Cable Connectivity.

TF-FS02 BLUETOOTH FUSION SPLICER Marine Street Farmingdale, NY (631) WE-CABLE

AV6481 Optical Fiber Fusion Splicer

PROLITE-40B OPTICAL FIBER FUSION SPLICER

AD450 Optical Fiber Fusion Splicer

Core-Aligning Fusion Splicers

FIBRE OPTIC FUSION SPLICING EQUIPMENT SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

Punch Down Tool. Krone. Krone compatible metal punch down tool used to terminate UTP network cable into patch panel or face plate punch down jacks.

AV6471A FTTH OPTICAL FIBER FUSION SPLICER

User manual Model: VIU-800 Brand:

GE A Acoustic Belt Tension Tester. User s Operation Manual

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

FIBER OPTIC SPLICERS. delivering products, knowledge, service and experience

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket

ARX 308 User Reference Manual

MPC " Industrial Web Tablet with Windows CE

Medimaging Integrated Solution Inc.

Optical Fiber Fusion Splicer User Manual

ILSINTECH Swift K11 Optical Fiber Arc Fusion Splicer

OPTICAL FIBER SOLUTIONS

Emerging Fiber Termination Solution

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

INJ-24A Series Quick Installation Guide

TYPE-81C Administrator menu

OptiSplice one Fusion Splice System for Applications in FTTx and LAN Environments. EMEA, APAC & China Edition Issue 2

TRC-190 User s Manual

Review of Generic Requirements for Remote Radio Head Protection Used in Fiber to the Antenna (FTTA) Systems GR-3177-CORE Issue 1, December 2014

SL-NW100. Introduction. How to Charge. How to Mount. Switch Operation. Appendix. CatEyeSYNC Manual (PDF)

Built-in Fanless Ionizer! BM-20. BM-22 (Smart range) BM-252. Series. Micro Analytical Balances BM-200 BM-300 BM g 0.

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product

Ref Art. Nr. OSSGN. Operating instructions. Electric-arc fusion splicer.

White Paper. FASTConnect or FUSEConnect Which Should You Choose? ABSTRACT INTRODUCTION. Tom Jeffers, Associate Product Manager, AFL

User Manual. Printer P-52RUE

FUSION SPLICERS Splicing Made Easy and Affordable

Lenovo S60-a. Quick Start Guide. Read this guide carefully before using your smartphone.

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

Air Ion Counter - Operation Manual MOC 320 Oct. 16

Portable MEMS Inclinometer

Integrated Systems Central Europe


Wireless Inspection Camera with recording LCD monitor. Product code: SRCAMV6 CAMERA NUMBER:

BlueCheck III (BC3) User Manual

IDCE-840CT Battery Discharger & Capacity Tester

Field Splice Systems Fusion Splicers, Accessories, Tools and Consumables

Your Eye Inside. VIDEO BORESCOPES Made in USA. The next generation of fully-portable, articulating videoscopes!

I/A Series Hardware Mobile Workstation Indoor Unit

Handheld Video Microscope

Control Panel CP600 CP651, CP651-WEB

User's Manual. High-speed GB-IB Extender ZS-6103EF Series ZS-6103EF-F1 ZS-6103EF-F5. Zenisu Keisouku Inc.

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Dolphin CN80 Mobile Computer Accessories Guide

EVO-TM2A EVO-TM2B Touch Screen Monitor

840CT Battery Discharger &Capacity Tester

User's Guide. Video Borescope. Models BR200 and BR250

Skorpio X4 Mobile Computer

Technical Specification & Warranty mypos Europe Ltd. mypos Mini EN

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Fusion Splicers and Tools

Control Panel CP600 CP635, CP635-B, CP635-WEB

GA-12. madur Polska sp. z o.o.

Docking Stations HP Elite USB-C Docking Station G2 HP Elite USB-C Dock G3 HP USB-C Travel Hub

A-307. Mobile Data Terminal. Android OS Platform Datasheet

SPECIFICATION. Preliminary. TFT-LCD Monitor TITLE. Signature Date Prepared by Date

Handheld Micro Ohmmeters RMO-H series

SMART Board Interactive Whiteboard System

USER MANUAL Video Particle Counter with built in Camera Model VPC300

FT-20 Fire Training Fog Machine User Manual English

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Docking Stations HP Elite USB-C Docking Station G2 HP Elite USB-C Dock G3 HP USB-C Travel Hub

Skorpio X4 Mobile Computer

Mobilink TM P80 & P80 Plus Mobile Receipt Printer Product Information Guide

HCC-CW-201A. CWDM Analyzer. Operation Guide

f200 English User Manual Contents

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

Termination Box MOTB-001

Transcription:

Date: Sep 01, 2017 Doc. No.: B-17M3008 Messrs. SPECIFICATIONS FOR RIBBON FIBER FUSION SPLICER 70R+ Prepared by Taku Otani Engineer Engineering Department Precision Equipment Division Power&Telecommunication Systems Company Approved by Toshiro Mizushima Group Manager Engineering Department Precision Equipment Division Power&Telecommunication Systems Company

Page: 1 of 8 SPECIFICATIONS FOR RIBBON FIBER FUSION SPLICER 70R+ 1. General These specifications cover the Ribbon Fiber Fusion Splicer 70R+, which is designed for splicing ribbon fiber and single-count fiber for telecommunication use, up to 12-fiber ribbon. 2. Characteristics of 70R+ 2.1 Features The 70R+ is equipped with precise fixed V-groove for fiber alignment ribbon fiber splicer. The 70R+ has a series of features, such as "Automated wind-protector and tube-heater" for quicker splicing cycle as well as fewer operation steps, "innovative carrying-case design" for quicker preparation, "powerful Li-ion battery" for longer operation, and wireless communication functions. Market is from backbone network installation to opt-electronics components production for quality splice. 2.2 Product safety and environmental adaptations The 70R+ has been tested in accordance with the following EMC directives. EMC directive testing, Radiation noise EN55011 Group1, Class A acquired. EMC directive testing, Radiation noise EN61000-6-4 tested and passed EMC directive testing, Noise resistance EN61000-6-2 tested and passed EMC directive testing, Fire/Electrification N61010-1 tested and passed The 70R+ has been tested in accordance with the following requirements. Telcordia GR-765-CORE 2.3 Shock resistance, dust resistance, and rain resistance 1) Shock resistance The 70R+ has been designed to resist shock in accordance with the following requirements. Condition : Ability to withstand shock from all directions. Reference specifications : Telcordia GR-765-CORE Dropping height : 76cm Clarification : The item is capable to make 10 splices meeting certain performance after the test. 2) Dust resistance The 70R+ has been designed to resist dust in accordance with the following requirements. Dust material : Total 6 spoons of 0.1 to 500 microns diameter Alumina Silicate powder Apply method : Vibrating the item with air-circulate powder in a closed box Condition : The wind protector shall be properly closed. Reference specification : Telcordia TR-NWT-000264 (modified harder by Fujikura) Clarification : The item is capable to make 10 splices meeting certain performance after the test. 3) Rain resistance The 70R+ has been designed to resist rain in accordance with the following requirements. Specification : JIS C 0034 Rain simulating : more than R=10mm/h Time duration : 10min. Condition : The wind protector shall be properly closed. Criteria : After drying, the splicer is capable to make 10 splices meeting splice specification. 4) Notification These tests do not guarantee that the 70R+ will not be damaged under these conditions.

Page: 2 of 8 2.4 Environmental standards compliance The 70R+ is designed and being produced in consideration of following rules of environmental acceptability. EU RoHS directive compliant EU WEEE directive compliant EU PFOS directive compliant China RoHS directive compliant 2.5 Fusion Connector applications The 70R+ is adopted for Fujikura s FuseConnect System. 2.6 Automated Wind Protector The wind protector can be set to automatically close after the fiber holder is set and open when splicing is completed. This new feature reduces operation time and improve productivity. 2.7 Slide in AC adaptor 70R+ has the structure that the AC adapter can be installed inside the unit. The AC adapter doesn't occupy any working space outside of the unit. 2.8 Wireless communication function 70R+ has equipped with wireless communication function with the peripheral tools and smartphone.. 3. Specifications (Operational) 3.1 Applicable Optical Fibers Applicable Fiber count Single, 2, 4, 5, 6, 8, 10, and 12 Type of fiber SM (ITU-T G.652 & G.657), MM (ITU-T G.651) DS (ITU-T G.653), NZDS (ITU-T G.655) Applicable Fiber Ribbon : Cladding diameter = 125 m, Ribbon fiber thickness = 0.25mm to 0.4mm dimensions Single : Cladding diameter = 125 m, Coating diameter = 250 m and 900 m Fiber cleaved length 10-13mm 3.2 Fiber setting The 70R+ accepts Fiber Holder system for fiber setting. Fiber holder, FH-50-12 Ribbon fiber, 12-fiber Fiber holder, FH-50-10 Ribbon fiber, 10-fiber Fiber holder, FH-50-8 Ribbon fiber, 8-fiber Fiber holder, FH-50-6 Ribbon fiber, 6-fiber Fiber holder, FH-50-5 Ribbon fiber, 5-fiber Fiber holder, FH-50-4 Ribbon fiber, 4-fiber Fiber holder, FH-50-2 Ribbon fiber, 2-fiber Fiber holder, FH-50-250 Coating diameter of 250 m Fiber holder, FH-50-900 Coating diameter of 900 m

Page: 3 of 8 Fiber holder, FH-60-250 Fiber holder, FH-60-LT900 Fiber holder, FH-60-DC250 Fiber holder, FH-60-IDC250 Fiber holder, FH-FC-20 Fiber holder, FH-FC-30 Coating diameter of 250 m Coating diameter of 900 m (5mm to 13mm cleave) For 900 m Loose Tube Fiber Coating diameter of 250 m (5mm to 13mm cleave) For Drop Cable Coating diameter of 250 m (5mm to 13mm cleave) For Low Friction Cable Coating diameter of 900 m (5mm to 13mm cleave) For 2mm sheath cord Coating diameter of 900 m (5mm to 13mm cleave) For 3mm sheath cord 3.3 Alignment of fiber The precise fixed V-grooves provide accurate fiber alignment. Two cameras observe fibers from both perpendicular axes, and fibers are aligned automatic by fiber image processing in both axes simultaneously. 3.4 Splicing Modes 1) Including preset splice modes, a total memory of 100 splicer modes are available. 2) The 70R+ has below Splice Modes. AUTO mode General splice settings suited for all fibers (Except MM) SM-AUTO mode For Single mode fiber (ITU-T G.652 & G.657) SM-FAST mode For Single mode fiber (ITU-T G.652 & G.657) For quick splice operation MM-AUTO mode For Multi mode fiber (ITU-T G.651) DS-AUTO mode For Dispersion shifted fiber (ITU-T G.653) NZ-AUTO mode For Non-zero Dispersion shifted fiber (ITU-T G.655) Other modes Regular splice modes User programmable mode area are available 3.5 Splicing Performance Typical splice loss (measured by cut-back method relevant to ITU-T standards) SM (ITU-T G.652 & G.657) 0.05dB MM (ITU-T G.651) 0.02dB DS (ITU-T G.653) 0.08dB NZDS (ITU-T G.655) 0.08dB Return loss 60dB or greater Typical splicing time SM AUTO mode 15 sec AUTO mode 15 sec SM FAST mode 11 sec

Page: 4 of 8 3.6 Splice loss estimate function Cladding axis offset are taken into account for accurate loss estimate. 3.7 Tube heater 1) Including preset heating modes, a total memory of 30 heating modes are available. 2) Heating modes FP-03 FP-03(L=40) FPS01-400-15/20/25/34/40 FPS01-900-20/25/34/45 FP-04(T) FP-05 3) Typical Heating time FP-03 coating dia.250μm FP-03 coating dia.900μm FP-03(L=40) coating dia.900μm Fujikura micro sleeves FP-04(T) FP-05 For Fujikura FP-03 (L=60mm) protection sleeve For Fujikura FP-03 (L=40mm) protection sleeve For Fujikura FPS01-400-15/20/25/34/40 micro sleeves respectively For Fujikura FPS01-900-20/25/34/45 micro sleeves respectively For Fujikura FP-04(T) protection sleeve For Fujikura FP-05 protection sleeve 13sec. 14sec. 17sec. 5 to 16 sec 18 sec 40 sec 4) Automated Tube-heater Auto-cover close and auto-start feature when splice joint is set in the heater unit. The clamping speed of the tube heater has been shortened from the previous model. 5) Fiber tensioning available. 3.9 Storage of Splice Results No. of splice memory Data stored 2,000 splices Date, Splice mode No./title1/title2, error message, estimated splice loss, cleave angle, axial offset, cleave angle threshold, estimated splice loss threshold, arc power, arc time. 3.10 Arc power calibration Real-time arc calibration Automatic arc power calibration Manual arc power calibration The arc power and time are automatically calibrated real-time by cladding illumination feed back during arc discharge. Applied to all AUTO splice modes. The arc power and time are automatically calibrated based on previous arc discharge. Applied to all AUTO splice modes. Manual arc power calibration function is available by using fiber s melting amount measuring. 3.11 Tension test Tension load 1.96N (200gf) to 2.25N(230gf) 3.12 Electrodes life 1,500 arc-discharges are possible by a pair of electrodes. 3.13 Wind protector Wind protector automatically open and close function. Auto start function by closing the wind protector is available.

Page: 5 of 8 3.14 Operating conditions Operating altitude Operating humidity Operating temperature Operating wind condition From 0 to 3,660m above the sea level From 0 to 95% RH(Non-dew) From 10 to 50deg.C Up to 15m/s wind velocity 3.15 Storage conditions Storage humidity Storage temperature Long term storage temperature with battery From 0 to 95% RH(Non-dew) From 40 to 80deg.C From 20 to 30deg.C 4. Specifications (Product) 4.1 Dimensions and weight Dimensions Weight 146(W) x 159(D) x 150(H) mm Including wind protector, monitor, and rubber protector Excluding rubber foot 2.3kg, with ADC-18 AC adaptor 2.5kg, with BTR-09 battery 4.2 Fiber image display Viewing method Type of display monitor Surface protection of the monitor Image change-over Fiber view and magnification By two CMOS cameras for intersecting fiber viewing 4.7 inches TFT color LCD monitor Transparent plastic plate with anti-reflection coating The orientation of the screen is adjusted automatically according to monitor position. X / Y or both X and Y simultaneously (35X magnification) 4.2 Power Supply : AC adaptor Model name of AC adaptor AC power inlet DC power inlet Battery charge terminal DC outlet LED indicators Weight ADC-18, detachable AC adaptor Applicable voltage : from AC100V to AC240V Applicable current : Max.1A AC power cable : 3-pin cable with a grounding terminal, ACC-14 ~ ACC-17 Applicable voltage : from DC10V to DC15V Applicable current : Max.6A DC power cable : proprietary 3-pin cable, DCC-12, DCC-13 Charge cable : proprietary 5-pin charge cord, DCC-18 Applicable battery : proprietary battery, BTR-09 Charging time : approximate 5 hours Charging voltage and current : Max.16.8V, Max.0.8A Simultaneous battery charging and splice operation possible To main body : proprietary 8-pin connector Supply voltage and current : DC12V, 4A Green : normal and proper DC power supply Red : DC input voltage is over 15V Yellow : Battery is being charged Yellow blinking : Abnormal battery charging 386 g

Page: 6 of 8 4.3 Power supply : Battery Model name of battery Battery type Charging DC outlet Operation conditions Long term storage conditions Battery capacity Weight 4.4 Terminals USB terminal HJS terminal 4.5 Carrying case Dimensions BTR-09, detachable and rechargeable battery lithium battery 14.8V output voltage, 4000mAh capacity Remaining amount indicator equipped Charge power supply : ADC-18 Charge cord : proprietary 5-pin charge cord, DCC-18 Able to charge battery during splice operation when the battery is slotted in the splicer main body. To main body : proprietary 8-pin connector Supply voltage and current : DC14.8V, 4A Charging temperature : from 0 to 40 deg.c Discharging temperature : from 10 to 50 deg.c The battery to be fully discharged and charged in every 6 months to prevent the battery from memory effect. Storage temperature : from 20 to 30 deg.c The battery to be fully charged in every 6 months to prevent the battery from chemical damage caused by complete discharge. 110 splice and heat cycles 557 g Status : Slave Use for : Data and video signal transfer to PC Connector type : Mini-B Specification : USB2.0 Use for : power supply for HJS-02, HJS-03 Connector type : 6-pin Mini-DIN connector Supply power : DC12V, continuous 1A 547(W) x 277(D) x 281(H) mm, excluding rubber foot Including working table and strap 4.6 Wireless communication Wireless technical standard Bluetooth 4.1 Communication target RS02/03 Smartphone with Android or ios Wireless Certification Japan, USA, Canada, EU Member States, China, India etc *For details, refer to the following Splicer website: https://www.fusionsplicer.fujikura.com/ Communication distance up to 5 to 10 m (equivalent to Class 2) 4.6 Operating software User can upgrade the operating software for the 70R+, when new version released, via Internet. Instructions for software upgrade are described in the CD contained in the standard package.

5. Standard package Items/accessories stated in the table below are supplied as the 70R+ Standard Package. No. Name Model Q ty Note Doc. No.: B-17M3008 Page: 7 of 8 1 Fusion splicer 70R+ 1 pc. -- 2 Electrodes ELCT2-20A 1 pair Installed 3 AC adaptor / battery charger ADC-18 1 pc. - 4 AC power cord ACC-xx 1 pc. One of below types ACC-14 : USA, JAPAN type ACC-15 : Europe type ACC-16 : UK type ACC-17 : Australia type 5 Spare electrodes ELCT2-20A 1 pair -- 6 USB cable USB-01 1 pc. -- 7 Quick reference guide Q-70R+/19R+-E 1 pc. English 8 Instruction manual M-70+ 1 pc. CD containing operation manual and PC software 9 Warning and cautions W-70+-E 1 pc. English 10 Splicing report - 1 pc. English or Japanese 11 Carrying case CC-30 1 pc. Including working table and strap 12 Alcohol Pot AP-01 1pc 13 Screw Driver SD-01 1pc 14 Sleeve Loader SL-01 1pc 15 V-Groove Cleaning Brush VCB-01 1 pc 6. Optional accessories for Splicer Items stated in the table below are optional items and items for sell separately. No. Name Model Note 1 Fiber Holder FH-50-12 For 12-fiber ribbon FH-50-10 For 10-fiber ribbon FH-50-8 For 8-fiber ribbon FH-50-6 For 6-fiber ribbon FH-50-5 For 5-fiber ribbon FH-50-4 For 4-fiber ribbon FH-50-2 For 2-fiber ribbon FH-50-250 For 250 m coating, single count fiber FH-50-900 For 900 m coating, single count fiber FH-60-250 For 250 m coating, single count fiber FH-60-LT900 For 900 m coating, single count loose tube fiber FH-60-DC250 For 250 m coating, single count fiber in drop cable FH-60-IDC250 For 250 m coating, single count fiber in low friction cable FH-FC-20 For 900 m coating, single count fiber in 2mm sheath cord (Left side only) FH-FC-30 For 900 m coating, single count fiber in 3mm sheath cord 2 Battery pack BTR-09 Li-Ion battery 3 Battery charge cord DCC-18 Use for connecting BTR-09 and ADC-18 4 DC power cord DCC-12 For ADC-13, Cigarette lighter socket type DCC-13 For ADC-13, Alligator clamp type 5 Electrodes ELCT2-20A -- 6 Primary Coat Stripper PS-02 For single 250 m fiber

7 Jacket Stripper JS-01 For single 900 m fiber 8 Fiber Cleaver CT-05 For single fiber only CT-30 For single - 12 ribbon fibers cleaving 9 Fiber Protection FP-03 For single 250 m ~ 900 m(l=60) Sleeve FP-03(L=40) FP-04T FP-05 Micro sleeves 10 Ribbon Fiber Stripper RS02 RS03 11 Transfer clamp CLAMP-DC 12 J-Plate JP-06 For single 250 m ~ 900 m(l=40) For 8 ribbon fiber For 12 ribbon fiber For different type of single fiber Battery type Doc. No.: B-17M3008 Page: 8 of 8 7. Appearance. 70R+ Note: Specifications described herein are based or tested on Fujikura standards. Descriptions and specifications are subject to change without prior notice. ++ END OF SPECIFICATIONS ++