HI-POT TESTER. User s Manual

Similar documents
HI-POT TESTER User Manual

MOTOR ARMATURE TESTER

MOTOR STATOR TESTER ENGLISH MANUAL. 2 st Oct 2009 V1.1Version

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

8751/ Wire Universal Cable/Harness Tester

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

INSTRUCTION MANUAL AC AUTOMATIC INSULATION/ WITHSTANDING HiTESTER

C.A 6165 Appliance multitester

2-Wire universal Cable /Harness Tester

TH2683 Insulation Resistance Meter. User s Mannual

IMPULSE / SURGE TESTER 7703 User Manual

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

3700 SERIES USER MANUAL

OPERATION MANUAL. TH5100 Series Withstanding Voltage Tester. TONGHUI (CHANGZHOU) Electronic Co., Ltd. Version 1.0

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User's Guide. Model W 3-in-1 Switching DC Power Supply

SC6540. Quick Start Guide

I. PANEL DESCRIPTION... 1

Universal AC Power Source + AC Power Analyzer

Model 7705 Control Module

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Application Note. Use of Palm Switches with QuadTech Hipot Testers

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

EC Declaration of Conformity

M191. Operation manual. Insulation Tester Calibrator

Dielectric Withstand and Ground Bond Testers

99 Washington Street Melrose, MA Phone Toll Free Visit us at

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

OPERATING INSTRUCTION

Model 2440 Service Manual Rev. B / December 2004

ELECTRICAL SAFETY TESTER USER MANUAL ELECTRICAL SAFETY TESTER USER MANUAL

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

2-2 Testing space Tension and Compression test can be available at the lower section of movable crosshead. Upper tension type : Sold separately.

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

Electrical Safety Tester

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Series 2200 Multichannel Programmable DC Power Supplies User Manual

i.shine 1136 RGBW Color Stainer CN USER MANUAL

RESISTANCE/CURRENT METER Model 863/6487

User Guide True RMS Multimeter Extech EX205T

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

User's Guide. MiniTec TM Series Model MN25 MultiMeter

CONTENT Warning...1 I.Brief Introduction...3 II.Electrical Symbol...4 III.Series Model...4 IV. Technical Specifications...4 V.

PF LED Profile. User Manual

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

INSTRUCTION MANUAL. AUTOMATIC INSULATION WITHSTANDING HiTESTER

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

Multifunction Calibrator

SI3300. user and installation manual. 4-20mA/DC-Digital Display

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.

Demonstration Case BENNING DB 1

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

IMPORTANT SAFETY INSTRUCTIONS

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

3153 Instruction Manual

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

RIGOL. Quick Guide. DSA1000 Series Spectrum Analyzer. Nov RIGOL Technologies, Inc

Model 2700 Multimeter/Data Acquisition System Service Manual

Mini Digital Multimeter

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

EPS Power Supply

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

CW-WW LEDWash USER MANUAL

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Blitzer Strobe. User Manual. Order code: EQLED366

ZF LED Zoom Fresnel. User Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

ETHOS Auto Ranging Digital Multimeter

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Manual Control Unit GFC 32

MANUAL PCE-123

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Earth Resistance and Resistivity Tester

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

High Precision Quad Output DC Power Supply

2 in 1 LAN Tester and Multimeter Model:

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Model 2001 Multimeter

NETRONICS HS3500 CONTROLLER

OPERATION MANUAL TOS5052 DANGER

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

CE MultiTesterXA MI 3394 Quick Guide Ver , Code no

700 Series 200 Amp Clamp Meters

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

FG-7000 Digital Force Gauge Operation Manual

TC100 Precision Thermocouple Calibrator

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

GCI-5K INSTALLATION AND OPERATOR S MANUAL

Blitzer RGB Strobe. User Manual. Order code: EQLED365

i.shine 3148 RGBW Color Stainer XP USER MANUAL

VAT series controller and transmitter. Manual

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Manual Simatek Control Unit GFC 32

AutoRanging Digital MultiMeter

Transcription:

HI-POT TESTER 7620 User s Manual

Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control... 5 1.7 Malfunction... 5 1.8 Switch the Unit off...... 5 1.9 Preservation... 5 1.10 In case of emergency... 5 2. General Instruction... 5 3. 2.1 Contents and Accessories... 5 2.2 The Front Panel... 6. 2.3 The Back Panel... 7 Operation Instruction... 8 3.1 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 Display... 8 OPERATION... 8 3.2.10 3.2.11 Test Step (Step):... 9 Test Mode (Mode):... 9 Voltage setup (Volt):... 9 Frequency selection (Freq )... 9 Setup High Limit (HI )... 9 Setup Low Limit (LO)... 9 Setup Offset (OFFS )... 9 Setup Arcs (Arcs)... 9 Setup Dwel (Dwel )... 9 Setup Ramp time(ramp)... 10 High Voltage Output setting (CH)... 10 3.3 SYSTEM SETUP (System):... 10 3.3.1. 3.3.2. 3.3.3. 3.3.4. 3.3.5. Test Mode... 10 Step Test Fail... 10 Test Next Step By... 10 Output Step Signal... 11 Alarm... 11 2

3.3.6. PASSWORD... 11 3.4 CONFIG KEY... 12 3.4.1 AC H.V. CALIBRATION...... 12 3.4.2 DC H.V. CALIBRATION...... 12 3.4.3 LOAD DEFAULT AC & DC CALIBRATION VALUE... 12 3.5 FILE KEY... 13 3.5.1 Save File... 13 3.5.2 Load File... 13 3.5.3 DEL File... 13 3.6 Function KEYS... 13 3.6.1 Test Key... 13 3.6.2 Abort Key... 14 3.6.3 Reset Key... 14 3.6.5 Enter Key... 14 3.7 Key Lock Function... 14 3.8 Remote Control (REMOTE)... 14 3

1. Before WARNING! This equipment is intended for use by suitably trained and competent person. This product is capable of having hazardous voltages of 6000V DC for testing, appropriate precautions should be taken for safety. This product can cause hazards if it is not used in accordance with these instructions. Read them carefully and follow them in all respects. Double-check connections to the unit before use. DO NOT USE THIS EQUIPMENT IF IT IS DAMAGED. 1.1 Electric Shock Avoidance Please wear a pair of insulating gloves when using the equipment to avoid electric shock. 1.2 Grounding Disconnection of the protective ground terminal is likely to make the equipment dangerous. Check connections to the ground terminal on the back panel carefully. 1.3 AC Power Supply This equipment is provided with power cable capable of carrying the input current for both 115V and 230V operation. The Supply voltage can be checked by looking on the rear panel next to the power inlet connector. The supply voltage setting can be changed by first disconnecting the unit from the power supply and adjusting the switch to read required voltage. Before applying power to the instrument, ensure that the voltage selector located at rear panel is set to the voltage of the local power supply. 1.4 Connecting Test Leads to High Voltage output terminal Turn off the equipment before connecting the tes leads to the high voltage output terminal. Ensure the wires and leads are in a safe condition. 1.5 Warm-up This equipment can begin work immediately after turned on, for more accura te results, please wait 15 minutes for the tester to warm-up. 4

1.6 External control The tester can be controlled by external signals. Be sure that the operator can not reach the high-tension output terminal and the object during the external control. 1.7 Malfunction If find there are malfunctions with the tester (For Example: There is a great difference on value between the voltage displayed by the voltmeter and the voltage you set, or the signal lamp for high-tension output terminal steadily on while there is not high voltage outputting), please stop using it immediately, contact us for repairing. 1.8 Switching the unit off When the tester is not in use, please switch it off. 1.9 Preservation The unit can work efficiently at temperature of 5 o C ~ 40 o C, humidity of 80% RH, and can be stored in a place of -20 o C ~ 70 o C, 80% RH. Please do not put the tester at a dusty place or a place of high-temperature, high-humidity. Shaking frequently and insolation is also forbidden. 1.10 In Case of Emergency If receiving an electric shock or the tester is causing fire, please turn off the tester and disconnect the power source. 2. General 2.1 Contents & Accessories There should have the following items in the package: 1. HT-7620 HI-POT Tester *1 2. High voltage test leads (Red) *2 3. AC power cable *1 4. 3 to 2 AC Line Adaptor *1 5. User's manual *1 6. Safety pin for high-tension current output *1 5

2.2 The Front (8) (9) (1) (2) (3) (4) (7) (6) (5) (1) LCD Display (2) Navigation Keys (3) Control Keys (4) Data Entry Keys (5) High Voltage output terminal (6) High Voltage output terminal Signal (7) Power Switch (8) Test Key (With PASS LED) (9) Abort Key (With FAIL LED) 6

2.3 The Back Panel (3) (2) (1) (4) (5) (6) ( 7 ) (1) AC mains power input (2) Fuse holder (3) Ground terminal (4) Safety Inter Lock (5) Remote port (6) 115/230 voltage selector (7) RS-232 Port 7

3 OPERATION ISTRUCTION 3.1 (14) (13) (12) (11) (1) (10) (2) (9) ( 7 ) (3) (8) (4) (5) (6) (1) High voltage output channel: HV channel-rt channel. (2) Output voltage. (3) Voltage setting. (4) Hi-limit setting. (5) Low-limit setting. (6) Current value detected (In IR mode, it is the resistance value). (7) Arc acuity setting, the value is 0 when arc detect is off. (8) Test duration. (9) Test duration setting. (10)Number of current step. (11) S stands for Single-test step while M stands for Multi-test step. (12)Units. Display Ωin IR mode (13)Massages of tester status. (14)Current test mode: AC, DC or IR. 3.2 Operation Please ensure the safety inter lock is plug in before testing, the unit will not out put high voltage and will display HI POT LOCK if safety inter lock is not in its place. When idling,press Setup key to enter option menu (Figure 1), use left and right arrow to shift the items, and use up and down arrow or numeric keyboard to change. 8

3.2.1 Test Step (Step ) Display current step, use up arrow and down arrow or numeric keyboard to edit. 3.2.2 Test Mode (Mode) Use up arrow and down arrow to shift the modes between AC, DC &IR. 3.2.3 Voltage Setup (Volt ) Use up arrow and down arrow to edit output voltage setting or key in the voltage value by numeric keypad (If the value you keyed in beyond the upper limit or below the lower limit, it will automatically fit the limit). 3.2.4 Frequency Selection (Freq.) Use up arrow and down arrow to shift the AC frequency between 50Hz & 60Hz. 3.2.5 Setup High Limit (HI) There will be a message showing HILIMIT as the FAIL indicator indicates when the current detected is beyond the upper limit. 3.2.6 Setup Low Limit (LO) There will be a message showing LOLIMIT as the FAIL indicator indicates when the current detected is beyond the lower limit. If the voltage is rising, the check for lower limit will pause until the process of rising finish. 3.2.7 Setup Offset (OFF) There are two ways for offset calibration: Auto setting & Manual setting. Auto setting: Put the cursor at OFF and press TEST, then the tester will te st the voltage and display the result, also a string of SAVE=ENTER shows up, press ENTER to save the result or press EXIT to abort. If the result saved, every time the test is running, the certain value would be taken out to make the test more accurate. 3.2.8 Setup Arcs (Arcs) The way to set Arc Sensitivity is the same as the one for other settings. The higher the value is, the lower sensitive it will be for the tester to arcs. And it will be ignored if the value sets at 0. 3.2.9 Setup Dwel (Dwel ) The value here determines the lasting time of test. If the value equals 00.0, there will be a continuous test until a low quality item detected or ABORT is pressed. 9

3.2.10 Setup Ramp Time (Ramp) The time needed for voltage to rise to preset voltage from 0. 3.2.11 High Voltage Output Setting (CH) Put the cursor at the output terminal channel, use up arrow and down arrow to shift the modes between HV & RT. One pair of HV &RT is needed at least. (Figure 1) Figure 1 3.3 SYSTEM SET-UP: Press SYS to enter the system option menu (Figure 2). Figure 2 3.3.1. TEST MODE Using the numeric key 1 to shift the test mode between SINGLE STEP & ALL STEP, if choose ALL STEP mode, the test will perform methodically from the 1 st step to the 8 th step when the test stared. Notice that if one of the steps is not set with output terminal, it will not be tested as the 3.3.2. STEP TEST FAIL User can select this option to stop the instrument from further testing when a low quality item is detected in a multi-step test. User can shift between the options by pressing numeric key 2. If choose STOP, the test will end as a low quality item is detected while choosing CONTINUE may ignore such a condition. 10

3.3.3. TEST NEXT STEP BY This mode is the trigger for the steps in a test. User can shift between the options by numeric key 3. If choose TEST KEY, the test will pause until the TEST key is pressed for every step while choosing AUTO may ensure a continuous test. 3.3.4. OUTPUT STEP SIGNAL User can use this option to set the signals for every step in a multi-step test. User can shift between the options by numeric key 4. If choose YES, the tester will display the signal results for every step while choosing NO the tester may display the judgment at the end of the test (in this condition, the judgment will be FAIL even there is only one low quality item). 3.3.5. ALARM It is the switch for FAIL alarm. User can shift between the options by numeric key 5. If choose ON, the FAIL signal lamp will bright with a beep while choosing OFF the signal lamp will bright without a beep. 3.3.6. PASSWORD Change password. Input the original password first, then input the new password and confirm it. (The original password for the system is 7620) Figure 2 11

3.4 CONFIG This key is used to enter the system option menu shown on Figure 3. Figure 3 3.4.1 AC H.V. CALIBRATION User can use it to correct the AC H.V. when there is something wrong with the voltage. Press numeric key 1 in system option menu followed by the password, take off the two clamps in order to avoid the influence on output voltage of terminal load. Enter the AC H.V. CALIBRATION menu (Figure 2), there will be a value of preset voltage to the left, a correcting code for voltage in the middle and the voltage detected to the right. At the beginning, the cursor will be on the line marked 500V and detect the voltage of it. Use up arrow and down arrow to adjust the detected voltage to the preset voltage by change the correcting code. The higher the correcting code is, the higher the output voltage will be. Press ENTER to shift to the next line, correct the AC H.V. in the same way. If you press ENTER while the cursor is on the line marked 2500V, the cursor will back to the line marked 500V. You can turn to the next page to continue the work by press the right button. When the work is finished, press EXIT to exit, the values will be saved automatically. 3.4.2 DC H.V. CALIBRATION User can use it to correct the DC H.V. when there is something wrong with the voltage. The method is the same as the AC H.V. correcting. Notice that the maximum voltage for DC is 6000V and there will be two more line than the AC H.V. correcting. 3.4.3 LOAD DEFAULT AC CAL. VALUE&LOAD EEFAULT DC CAL. VALUE User can load Default AC/DC Cal. Values by press S3/S4 followed by the password in the system option menu. The system will warn user with a message that Current correcting code will be lost. Press ENTER to load the default values or press EXIT to abort. 12

3.5 FILE Press it to enter the File Management menu (Figure 4). Figure 4 3.5.1 Save File User can use it to save the file when all the data are checked. Press 1 in the File Management menu to save the file. The filename must be a number within 8 characters. You can save 30 groups of data at most. Once saved, the data will be stored in the memory and won t be lost even if you switch off the tester. 3.5.2 Load File Load saved file. Press 2 in the File Management menu to load file. You can either key in the filename or use the up and down arrow keys to load file. 3.5.3 DEL File To delete file, please press the key 3 in the File Management menu. 3.6 FUNCTION KEYS The Function Keys are located on the instrument s upper right front panel, also displayed on Page 6 of this manual. 3.6.1 TEST Key Press TEST to start all tests. 13

3.6.2 ABORT Key Press this key to abort a test and return to the ready mode. It can also stop the action of signal lamp and beeper caused by an FAIL result. 3.6.3 RESET Key Press this key to reset the system. The data will be reloaded as the last saved file. 3.6.4 EXIT Key Press this key to exit the current menu, and return to the previous menu. 3.6.5 ENTER Key Press this key to enter into the selected menu. 3.7 Key Lock Press ENTER during the displayed opening message soon after the tester is switched ON to enable the KEY LOCK mode. There will be a message shown on the screen as KEY LOCK: ON. In this mode, the user can only carry out the test; this prevents data from being edited. To quit this mode, please reset the tester and press ENTER during the opening massage displaying. There will be a message as KEY LOCK: OFF shown on the screen as you successfully quit the mode. 3.8 REMOTE Control REMOTE port can be found on the back panel of the tester. Once connected, it enables you to operate the tester by external signals. The high voltage output terminal is hazardous, make sure that the operator cannot make contact with the remote port. Internal circuit diagram PIN# NAME FUNC 1 CTL1 WIND1 2 CTL2 WIND2 3 CTL3 WIND3 14

4 5 6 7 8 9 10 11 12 13 14 15 CTL4 CTL5 CTL6 CTL7 CTL8 V1 SW1 SW2 RST V2 V3 GND WIND4 Fixture PASS FAIL H.V. ON +12V TEST ABORT RESET +5V +12V Explanation: The CTL1-CTL8 contacts serve as the switch; they can not output voltage or signal. The current flowed through the contacts mustn t bigger than 100mA. (1) TEST: Cause a short circuit between the 13 th Pin (V2) and the 10 th Pin (SW1) can perform the function as TEST on the front panel. (2) ABORT: If the 13 th Pin (V2) and the 11 th Pin (SW2) are shorted. This can perform the same function as ABORT on the front panel. (3) RESET: If 13 th Pin (V2) and the 12 th Pin (RST) are shorted. This can perform the can perform the function as RESET on the front panel. (4) PASS: The 6 th Pin will earth if the device under test is within tolerance (High quality). (5) FAIL: The 7 th Pin will earth if the device under test is outside tolerance (Low quality). (6) H.V. ON: The 8 th Pin will earth as the terminal is outputting high-tension current. This signal indicates the instrument is in testing mode. Solenoid valve coil 1. Use H.V. ON contact to control the valve of fixture. 2. Signals for PASS, FAIL&LED 15