SIMATIC. ET 200SP HA Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Security information 1. Product overview 2.

Similar documents
SIMATIC. ET 200SP HA Digital Input Module DI 32x24VDC HA (6DL1131-6BL00-0PH1) Security information 1. Preface 2. Product overview 3.

Siemens Distributor SIMATIC. ET 200SP HA Digital Input Module DI 16x24VDC HA (6DL1131-6BH00-0PH1) Security information 1. Product overview 2.

ST (6ES7132-6FD00-0BB1)

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP Digital output module RQ 4x120VDC-230VAC/5A NO ST (6ES7132-6HD01-0BB1) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP HA Analog output module AQ 8xI HART HA (6DL1135-6TF00-0PH1) Security information 1. Product overview 2. Wiring 3.

ST (6ES7522-1BH00-0AB0)

SIMATIC. ET 200SP Digital output module RQ 4x24VUC/2A CO ST (6ES7132-6GD51-0BA0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP Digital input module DI 8x24VDC BA (6ES7131-6BF01-0AA0) Preface. Documentation guide 1. Product overview 2.

Digital output module. DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0) SIMATIC. ET 200SP Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0)

ST (6ES7522-5HF00-0AB0)

Digital output module. DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0) SIMATIC. ET 200SP Digital output module DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0) Preface

Digital output module. DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) SIMATIC

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview.

Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) SIMATIC. ET 200SP Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) Preface

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Digital output module. DQ 8x24VDC/0.5A HF (6ES7132-6BF00-0CA0) SIMATIC. ET 200SP Digital output module DQ 8x24VDC/0.5A HF (6ES7132-6BF00-0CA0) Preface

SIMATIC. S7-1500/ET 200MP Digital output module DQ 32x24VDC/0.5A BA (6ES7522-1BL10-0AA0) Preface. Documentation guide. Product overview.

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

SIMATIC. ET 200SP Digital input module DI 8x24VDC ST (6ES7131-6BF01-0BA0) Preface. Documentation guide. Product overview.

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

SIMATIC. S7-1500/ET 200MP Technology Module TM NPU (6ES7556-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200SP HA Analog Input Module AI 16xI 2-wire HART HA ( 6DL1134-6TH00-0PH1) Security information 1. Product overview 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200SP HA Input/output module AI-DI 16/ DQ16x24VDC HART HA (6DL1133-6EW00-0PH1) Security information 1. Product overview 2.

Analog output module AQ 2xI ST (6ES7135-6GB00-0BA1) SIMATIC. ET 200SP Analog output module AQ 2xI ST (6ES7135-6GB00-0BA1) Preface. Documentation guide

Digital output module. DQ 16x24VDC/0.5A HF (6ES7522-1BH01-0AB0) SIMATIC

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Digital input module. DI 8x24VDC HF (6ES7131-6BF00-0CA0) SIMATIC. ET 200SP Digital input module DI 8x24VDC HF (6ES7131-6BF00-0CA0) Preface

SIMATIC. S7-1500/ET 200MP Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Preface. Documentation guide. Product overview.

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

Readme SiVArc V14 SP1 Update 6

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

Siemens Drives & PLCs

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Digital input module DI 8x24VDC HS (6ES7131 6BF00 0DA0) SIMATIC ET 200SP (6ES7131 6BF00 0DA0) Preface. Documentation guide.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SIMATIC. ET 200SP DQ 4x VAC/2A HF digital output module (6ES7132-6FD00-0CU0) Preface. Guide to documentation 1. Product overview 2.

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200AL Interface module IM DP (6ES7157-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring 3.

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC. ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Preface. Guide to the documentation. New properties. Product overview 3

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0)

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC S Analog output module AQ 4xU/I ST (6ES7532-5HD00-0AB0) Manual. Answers for industry.

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

Digital output module. F-DQ 4x24VDC/2A PM HF (6ES7136-6DB00-0CA0) SIMATIC. ET 200SP Digital output module F-DQ 4x24VDC/2A PM HF (6ES7136-6DB00-0CA0)

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

SINETPLAN Siemens Network Planner

Siemens Drives & PLCs

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

Preface. Guide SIMATIC. System overview. Integration into the automation system 3. IO-Link system. Function Manual 12/2017 A5E AB

Transcription:

Security information 1 Product overview 2 SIMATIC ET 200SP HA Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual Wiring 3 Parameters 4 Displays and interrupts 5 Technical specifications 6 Drivers, parameters, diagnostics messages and address space A 11/2017 A5E39389042-AC

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY A5E39389042-AC P 01/2018 Subject to change Copyright Siemens AG 2017. All rights reserved

Table of contents 1 Security information...5 2 Product overview...7 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA...7 3 Wiring...11 3.1 Pin assignment of the I/O module RQ 4x120VDC-230VAC/5A CO HA...11 3.2 Schematic circuit diagram...13 4 Parameters...15 4.1 Parameters of the I/O module RQ 4x120VDC-230VAC/5A CO HA...15 4.2 Module/channel parameters...16 4.3 Explanation of the module/channel parameters...17 5 Displays and interrupts...19 5.1 Status and error displays of the I/O module RQ 4x120VDC-230VAC/5A CO HA...19 5.2 Interrupts...21 6 Technical specifications...23 6.1 Switching cycles...26 A Drivers, parameters, diagnostics messages and address space...27 A.1 Concept of the driver and diagnostics blocks...27 A.2 Parameter assignment...29 A.3 Parameter assignment and structure of the module/channel parameters...31 A.4 Diagnostics messages and maintenance events...34 A.5 Address space...36 Index...37 Manual, 11/2017, A5E39389042-AC 3

Table of contents 4 Manual, 11/2017, A5E39389042-AC

Security information [ID: 91015510155] 1 Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines, and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial security measures that may be implemented, please visit: https://www.siemens.com/industrialsecurity Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://www.siemens.com/industrialsecurity. Validity of the documentation This device manual describes the RQ 4 x 120 V DC-230 V AC/5 A CO HA I/O module with the Article No. 6DL1132-6HD50-0PK0. It supplements the ET 200SP HA / ET 200SP HA Distributed I/O system system manual. Functions that generally relate to the system are described in this manual. The information in this device manual and the system/function manuals enables you to put the ET 200SP HA into operation. Appendices The appendices provide information that is relevant for using the ET 200SP HA outside the PCS 7 environment. Manual, 11/2017, A5E39389042-AC 5

Security information Conventions Please also observe notes marked as follows: Note A note contains important information on the product described in the documentation, on the handling of the product and on the section of the documentation to which particular attention should be paid. 6 Manual, 11/2017, A5E39389042-AC

Product overview 2 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA [ID: 80187982219] View of the module RQ 4x120VDC..230VAC/5A CO DIAG MT 1.0 11.1 3.2.3 5.0.1 7.2.3 9.0 14.1 11.2.3 13.0 12.1 15.2.3 HA 2 4 6 8 10 12 14 16 1P1 L+ 24VDC M 1P2 2P1 L+ 24VDC M 2P2.0.2 MAX. 10 A.1.3 PWR X 2 3 4 V 1.0.0 CC40 1 Module type and designation 8 Output disable switch 2 LED for diagnostics 9 Module type color coding 3 LED for maintenance 10 Product version 4 2D matrix code 11 Function status and firmware version 5 Wiring diagram 12 Color code for selection of the color-coded labels 6 LEDs for channel status 13 Serial number 7 LED for supply voltage 14 Article number Figure 2-1 View of the RQ 4x120VDC-230VAC/5A CO HA 6DL1132-6HD50-0PK0 Manual, 11/2017, A5E39389042-AC 7

Product overview 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA Properties NOTICE I/O modules with relay contacts I/O modules with relay contacts are only suitable for an elevation up to 3000 m (corresponds to air pressure of around 690 hpa). I/O modules with relay contacts are tested and approved in accordance with the relay manufacturer s specifications. Strength of shock: Peak value 98 m/s² Duration 11 ms The I/O module has the following technical properties: 4; electrically isolated relay outputs Change-over contact (CO: changeover) combination of an NC and an NO contact Suitable for solenoid valves, DC contactors, and indicator lights Channel-granular configurable substitute value reaction Module-specific configurable diagnostics for missing supply voltage L+ Output current per output 5 A The I/O module supports the following functions: Firmware update I&M identification data Parameter reassignment in RUN Value status QI You can configure the I/O module with HW Config and integrate it into your system Output disable switch If you want to pull the I/O module in runtime, you have to press the output disable switch for 3 seconds for the I/O module to be deenergized. Note that the NC contact is closed in this state. When the output disable switch has been pressed for 3 seconds, the LED DIAG flashes red, the LED MT lights up yellow and the I/O module generates a diagnostics message. See section Status and error displays of the I/O module RQ 4x120VDC-230VAC/5A CO HA (Page 19). Note Pressing the output disable switch interrupts any ongoing firmware update. A firmware update cannot be performed when the device is deenergized. 8 Manual, 11/2017, A5E39389042-AC

Product overview 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA Accessories The following accessories must be ordered separately: Labeling strips Color-coded labels Reference identification label Shield connector Manual, 11/2017, A5E39389042-AC 9

Product overview 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA 10 Manual, 11/2017, A5E39389042-AC

Wiring 3 3.1 Pin assignment of the I/O module RQ 4x120VDC-230VAC/5A CO HA [ID: 85663030923] Terminal blocks You can operate the I/O module with the following terminal blocks: 6DL1193-6TP00-0DK0, light 6DL1193-6TP00-0BK0, dark The terminal block is not included in the scope of delivery of the I/O module and must be ordered separately. Note You can find additional information on the configuration in the system manual. WARNING Risk of death or serious injury from electric shock! Prior to working on the system and module, always disconnect them from the power supply. NOTICE External fuse for relay outputs The outputs have to be protected with an external safety fuse with a maximum trip current of 6 A. The fuse has to be a micro fuse with the fast trigger characteristic. Manual, 11/2017, A5E39389042-AC 11

Wiring 3.1 Pin assignment of the I/O module RQ 4x120VDC-230VAC/5A CO HA General pin assignment Table 3-1 Pin assignment of the RQ 4x120VDC-230VAC/5A CO HA Terminal Assignment Terminal Assignment Explanations 1 3 5 7 9 11 13 COM 0 COM 2 COM 0 COM 2 C 0 C 2 O 0 2 4 6 8 10 12 14 COM 1 COM 3 COM 1 COM 3 C 1 C 3 O 1 COM n : Common contact C n : NO O n : NC 1P1: Supply voltage L+ of the voltage bus 1P 2P1: Supply voltage L+ of the voltage bus 2P 1P2: Ground reference of the voltage bus 1P 2P2: Ground reference of the voltage bus 2P 15 O 2 16 O 3 1P1 L+ 1P2 M 2P1 L+ 2P2 M 1.0 11.1 2 3.2.3 4 5.0.1 6 7.2.3 8 9.0 14.1 10 11.2.3 12 13.0 12.1 14 15.2.3 16 1P1 L+ 24VDC M 1P2 2P1 L+ 24VDC M 2P2 MAX. 10 A Note You can use the two COM ports for each channel for looping this signal through. Note that the maximum current capacity is 5 A. 12 Manual, 11/2017, A5E39389042-AC

Wiring 3.2 Schematic circuit diagram 3.2 Schematic circuit diagram [ID: 80188014219] The following figure shows the block diagram of the RQ 4x120VDC-230VAC/5A CO HA. Figure 3-1 Block diagram RQ 4x120VDC-230VAC/5A CO HA Manual, 11/2017, A5E39389042-AC 13

Wiring 3.2 Schematic circuit diagram 14 Manual, 11/2017, A5E39389042-AC

Parameters 4 4.1 Parameters of the I/O module RQ 4x120VDC-230VAC/5A CO HA [ID: 80188111115] Configuring You configure the I/O module with PCS 7 V9.0 or higher. Parameters You define the functioning of the I/O module via parameters. See also Parameter assignment (Page 29) Manual, 11/2017, A5E39389042-AC 15

Parameters 4.2 Module/channel parameters 4.2 Module/channel parameters [ID: 91038645131] Parameters of the RQ 4x120VDC-230VAC/5A CO HA You have the following setting options: Table 4-1 Parameters and their default settings Parameter Value range Default Parameter reassignment in RUN Diagnostics, Missing supply voltage L+ Enabled Disabled Channel activated Enabled Disabled Reaction to CPU STOP Turn off Substitute value 1 0 Keep last value Output substitute value 1 Potential group Use potential group of the left module Allow new potential group Disabled Yes Module Enabled Yes Channel Turn off Yes Channel 0 Yes Channel Use potential group of the left module 1 Only in effect when "Substitute value" has been enabled for the "Reaction to CPU STOP" parameter. No Efficiency range Module 16 Manual, 11/2017, A5E39389042-AC

Parameters 4.3 Explanation of the module/channel parameters 4.3 Explanation of the module/channel parameters [ID: 80188160651] Diagnostics, Missing supply voltage L+ Enabling of the diagnostics for missing or insufficient supply voltage L+. Channel activated Specifies whether a digital output is activated or deactivated. Reaction to CPU STOP Determines the reaction of the digital output to CPU STOP or to failure of communication between the interface module and CPU. Substitute value The substitute value is output by the module at CPU STOP if you set the "Reaction to CPU STOP" parameter to "Substitute value". Potential group A potential group consists of a group of directly adjacent I/O modules within an ET 200SP station HA, which are supplied via a common supply voltage. A potential group begins with a light terminal block, via which the required supply voltage is fed to all I/O modules of the potential group. The light-colored terminal block interrupts the selfassembling voltage buses to the left neighbor All other I/O modules of this potential group are plugged into dark terminal blocks. I/O modules on dark terminal blocks take the potential of self-assembling voltage rail from the left neighbor. A potential group ends with the dark terminal block, which follows a light terminal block or a server module in the station configuration. You can find additional information on the configuration of the potential group in the system manual SIMATIC; Distributed I/O System; ET 200SP HA. Manual, 11/2017, A5E39389042-AC 17

Parameters 4.3 Explanation of the module/channel parameters 18 Manual, 11/2017, A5E39389042-AC

Displays and interrupts 5 5.1 Status and error displays of the I/O module RQ 4x120VDC-230VAC/ 5A CO HA [ID: 80188253579] LED displays The following figure shows the LED displays of the I/O module. RQ HA 4x120VDC..230VAC/5A CO DIAG MT 1.0 11.1 2 3.2.3 4 5.4.5 6 7.6.7 8 9 11 13 15.0.2.0.2 14 12.1.3.1.3 10 12 14 16 1P1 LP+ 24VDC M 1P2 2P1 LP+ 24VDC M 2P2 MAX. 10 A.0.1.2.3 PWR X 2 3 4 V 1.0.0 CC40 1 2 3 4 6DL1132-6HD50-0PK0 DIAG LED (green/red) MT LED (yellow) Channel status LED (green) PWR LED (green) Figure 5-1 LED displays Meaning of the LED displays The following tables show the meaning of the status and error displays. Measures for dealing with diagnostics messages can be found in the section Diagnostics messages and maintenance events (Page 34). Manual, 11/2017, A5E39389042-AC 19

Displays and interrupts 5.1 Status and error displays of the I/O module RQ 4x120VDC-230VAC/5A CO HA DIAG LED Table 5-1 Diagnostics display of the DIAG LED DIAG LED Off Flashes On Flashes Meaning The power supply of the ET 200SP HA is disrupted or switched off Module is not configured. Module is configured, a diagnostics message is not pending. Module is configured, at least one diagnostic message is pending. MT LED Table 5-2 MT LED Off On Maintenance display of the MT LED Meaning No maintenance required. Maintenance is required, i.e. at least one maintenance event has occurred. Channel status LED Table 5-3 Status display of the channel status LED Channel status LED Off On Meaning Process signal = 0 or channel disabled Process signal = 1 and channel enabled PWR LED Table 5-4 Status display of the PWR LED PWR LED Off On Meaning Supply voltage L+ missing Supply voltage L+ available 20 Manual, 11/2017, A5E39389042-AC

Displays and interrupts 5.2 Interrupts 5.2 Interrupts [ID: 80188284939] The I/O module supports diagnostics interrupts and maintenance messages. Diagnostics interrupts The I/O module generates a diagnostics interrupt for the following events: Channel/component temporarily unavailable Parameter assignment error Supply voltage missing Retentive memory in carrier module defective Retentive memory in the terminal block defective Shutdown on button activation Maintenance messages The I/O module generates a maintenance message for the following events: Retentive memory in carrier module defective Retentive memory in the terminal block defective Manual, 11/2017, A5E39389042-AC 21

Displays and interrupts 5.2 Interrupts 22 Manual, 11/2017, A5E39389042-AC

Technical specifications 6 [ID: 80188333963] Technical specifications of the RQ 4x120VDC-230VAC/5A CO HA Article number General information Product type designation HW functional status 6DL1132-6HD50-0PK0 RQ 4x120VDC-230VAC/5A CO HA FS01 Firmware version V1.0 FW update possible Yes Usable terminal block Color code for module-specific color identification plate Product function TB type K0 CC40 I&M data Yes; I&M0 to I&M3 Engineering with PCS 7 configurable/integrated as of version V9.0 Redundancy Redundancy capability No Supply voltage Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) Reverse polarity protection Input current Current consumption (rated value) Current consumption, max. Power loss 24 V 19.2 V 28.8 V Yes 50 ma; At 24 V and energized changeover coils 60 ma; At 19.2 V and energized changeover coils Power loss, typ. 2.8 W; At 24 V, energized changeover coils and 5 A current across each changeover contact Address area Address space per module Address space per module, max. 1 byte; + 1 byte for QI information Digital outputs Number of digital outputs 4 Switching frequency with resistive load, max. 2 Hz with inductive load, max. 0.5 Hz on lamp load, max. 2 Hz Total current of the outputs Manual, 11/2017, A5E39389042-AC 23

Technical specifications Article number Current per channel, max. 5 A Current per module, max. 20 A Total current of the outputs (per module) horizontal installation up to 70 C, max. 20 A vertical installation up to 60 C, max. 20 A Relay outputs Number of relay outputs 4 6DL1132-6HD50-0PK0 external protection for relay outputs yes; 6 A, see data in manual Switching capacity of contacts with inductive load, max. 2 A; 2 A (24 V DC), 0.5 A (60 V DC), 0.1 A (120 V DC) with resistive load, max. 5 A; 5 A (30 V DC), 5 A (230 V AC) Switching current, min. 8 ma Rated switching voltage (DC) 24 V; 24 V DC to 120 V DC Rated switching voltage (AC) 230 V; 24V AC to 230V AC Cable length shielded, max. 1 000 m unshielded, max. 200 m Interrupts/diagnostics/status information Diagnostics function Substitute values connectable Alarms Yes Yes Diagnostic alarm Yes Diagnostic messages Monitoring the supply voltage Yes parameterizable Yes Diagnostics indication LED MAINT LED Yes; yellow LED Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED Channel status display Yes; Green LED for module diagnostics Yes; green/red DIAG LED Potential separation Potential separation channels between the channels Yes between the channels and backplane bus Yes Between the channels and load voltage L+ Yes Permissible potential difference between different circuits between channels and backplane bus/supply voltage Between channels: 230 V AC (different system phase) 230 V AC 24 Manual, 11/2017, A5E39389042-AC

Technical specifications Article number Isolation tested with between channels and backplane bus/ supply voltage 6DL1132-6HD50-0PK0 4 200 V DC/1 min, type test between backplane bus and supply voltage 1 500 V DC/1 min, type test Ambient conditions Ambient temperature during operation horizontal installation, min. -40 C; No icing horizontal installation, max. 70 C vertical installation, min. -40 C; No icing vertical installation, max. 60 C Extended ambient conditions relative to ambient temperature-atmospheric pressure-installation altitude Dimensions Width Height Depth Weights Weight, approx. 3 000 m due to converter type used 22.5 mm 115 mm 138 mm 162 g Manual, 11/2017, A5E39389042-AC 25

Technical specifications 6.1 Switching cycles 6.1 Switching cycles [ID: 80188362763] Switching capacity and lifetime of the contacts With an external protective circuit, the contacts will last longer than specified in the table. This table shows the switching capacity and lifetime of the relay contacts: Table 6-1 Switching capacity and lifetime of the relay contacts Resistive load Voltage Current Switching cycles (typical) For resistive load 24 V DC 5.0 A 0.1 million For resistive load 3.0 A 0.2 million 2.0 A 0.3 million 1.0 A 0.5 million 0.5 A 0.8 million 0.1 A 1 million 48 V DC 2.0 A 0.3 million 1.0 A 0.5 million 0.5 A 0.8 million 0.1 A 1 million 60 VDC 1.0 A 0.5 million 0.5 A 0.8 million 0.1 A 1 million 120 V DC 0.1 A 1 million 48 VAC to 230 VAC 5.0 A 0.1 million 3.0 A 0.2 million 2.0 A 0.3 million 1.0 A 0.5 million 0.5 A 0.8 million 0.1 A 1 million With inductive load 24 V DC 2.0 A 0.1 million With inductive load 1.0 A 0.3 million 0.5 A 0.5 million 0.1 A 1 million 48 V DC 1.0 A 0.3 million 0.5 A 0.5 million 0.1 A 1 million 60 VDC 0.5 A 0.5 million 0.1 A 1 million 120 V DC 0.1 A 1 million 48 V AC to 230 V AC 2.0 A 0.1 million 1.0 A 0.3 million 0.5 A 0.5 million 0.1 A 1 million 26 Manual, 11/2017, A5E39389042-AC

Drivers, parameters, diagnostics messages and address space A A.1 Concept of the driver and diagnostics blocks [ID: 96680281867] Use outside the PCS 7 environment The following information of the appendix relates to the use of the ET 200SP HA outside the PCS 7 environment. If you do not plan to operate outside the PCS 7 environment, you do not need the information in the appendix. Tasks of the driver and diagnostics blocks (driver blocks) In process control systems, certain demands are placed on the diagnostics/signal processing. This includes the monitoring of modules, DP/PA slaves and DP master systems for malfunctions and failures. To enable this, blocks are available in the PCS 7 library that implement the interface to the hardware including test functions. These blocks perform two basic tasks: They provide signals from the process to the AS for further processing. They monitor modules, DP/PA slaves, and DP master systems for failure. When the process signals are read in, these blocks access the process image input (or process image partition) (PII) and when the process signals are output, they access the process image output (or process image partition) (PIQ). Concept The concept of the driver and diagnostics blocks for PCS 7 can be characterized as follows: The separation between user data processing (CHANNEL blocks) and diagnostics data processing (MODULE blocks) The symbolic addressing of the I/O signals The automatic generation of the MODULE blocks by CFC Manual, 11/2017, A5E39389042-AC 27

Drivers, parameters, diagnostics messages and address space A.1 Concept of the driver and diagnostics blocks This block concept supports all modules from the list of approved modules. When new Siemens or non-siemens module types are integrated, the meta-knowledge for the driver generator can be extended by additional XML files (object and action lists). Note Note the following: The library with the driver blocks has to installed using the Setup program on the PC. This is the only method of ensuring that the meta-knowledge required for the driver generator is available. You must not copy the library from another computer. You can also use driver blocks from another library (for example, your own blocks from your own library). You can specify this additional library in the "Generate module drivers" dialog box. The driver generator then searches for the block to be imported in the library specified here. If the block is not found here, it is searched for in the library specified in the control file (XML file). If the S7 program contains a signal-processing block but not from one of the PCS 7 libraries, you have to specify the version of the driver library from which the driver blocks are to be imported in the "Generate module drivers" dialog box. Time-optimized processing To enable time-optimized processing during runtime, the organization blocks for error handling (for example, OB85, OB86) are automatically divided into runtime groups and the driver blocks are integrated in the corresponding runtime groups. If an error occurs, the SUBNET block, for example, activates the relevant runtime group, the RACK block or MODULE block contained in the runtime group detects the error, evaluates it and outputs a process control message to the OS. The diagnostics information of the module block (OMODE_xx output) is also transferred to the corresponding CHANNEL block (MODE input). If necessary, this information can be displayed by means of a PCS 7 block that can be operated and monitored on the OS or by means of a user block in a process picture (color change of the measured value or flashing display, etc.). 28 Manual, 11/2017, A5E39389042-AC

Drivers, parameters, diagnostics messages and address space A.2 Parameter assignment A.2 Parameter assignment [ID: 80188477835] Parameter assignment in the user program You can reconfigure individual channels of the module in RUN without this having an effect on the other channels. Changing parameters in RUN The "WRREC" instruction is used to transfer the parameters to the module using data record 128. The parameters set in STEP 7 are not changed in the CPU, which means that the parameters set in STEP 7 will be valid again after a restart. Output parameter STATUS Error_ Code_ 1 Error_ Code_ 2 If errors occur when transferring parameters with the "WRREC" instruction, the module continues operation with the previous parameter assignment. The STATUS output parameter contains the corresponding error code. The STATUS output parameter is 4 bytes long and is configured as followed: Byte1: Function_Num, general error code Byte2: Error_Decode, location of the error code Byte3: Error_Code_1, error code Byte4: Error_Code_2, manufacturer-specific extension of the error code Module-specific errors are displayed via Error_Decode = 0x80 and Error_Code_1 / Error_Code_2. Cause Solution 0xB0 0x00 Number of the data record unknown Enter valid number for data record. 0xB1 0x01 Length of the data record is incorrect Enter valid value for data record length. 0xB2 Variable Module cannot be reached Check station - is the module plugged in correctly? Check the parameters of the WRREC instruction. 0xE0 0x01 Wrong version in the header Correct the version number of the parameter block. 0xE0 0x02 Header error (number or length of parameter block) Correct the length and number of the parameter blocks. 0xE1 0x01 Reserved bit set Check and correct the parameters 0xE1 0x06 Invalid encoding for substitute value reaction Valid parameters Only the values specified in the following are permitted. Values that are not listed are rejected by the module. Manual, 11/2017, A5E39389042-AC 29

Drivers, parameters, diagnostics messages and address space A.2 Parameter assignment Every parameter data record is checked by the module. If an incorrect parameter is detected, the entire data record is rejected and the parameters of the module remain unchanged. 30 Manual, 11/2017, A5E39389042-AC

Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters A.3 Parameter assignment and structure of the module/channel parameters [ID: 91040766603] Structure of data record 128 Data record 128 has a length of 20 bytes. It contains module parameters as well as channel or technology parameters of the 4 channels; 2 bytes each. Figure A-1 Structure of data record 128 Manual, 11/2017, A5E39389042-AC 31

Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Header information and module parameters The following figure shows the structure of the header information and module parameters. Figure A-2 Header information and module parameters of data record 128 32 Manual, 11/2017, A5E39389042-AC

Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Channel parameters Each channel parameter block contains the cable parameters for the digital output (2 bytes). The following figure shows the configuration of the channel parameters for data record 128. x = 12 + (channel number * 2); with channel number 0 3 Any unused bits and bits or bytes marked with "reserved" must be set to zero. Activate a channel parameter by setting the corresponding bit to "1" or to the appropriate value. Figure A-3 Structure byte x to x+1 for the channels 0 to 3 Manual, 11/2017, A5E39389042-AC 33

Drivers, parameters, diagnostics messages and address space A.4 Diagnostics messages and maintenance events A.4 Diagnostics messages and maintenance events [ID: 80188307851] Diagnostics messages A diagnostics message is generated for each diagnostics event and the DIAG LED on the RQ 4x120VDC-230VAC/5A CO HA flashes red or the MT LED lights up yellow. The diagnostics messages can be read in the diagnostics buffer of the CPU, for example. Diagnostic messages are assigned either channel-specific to an output or assigned as module messages to all outputs. All channels are switched off for diagnostics messages that affect the entire module. Only the corresponding relay contact is affected by diagnostics messages, which refer to individual channels. Table A-1 Diagnostics messages, their meanings and corrective measures Diagnostics message Parameter assignment error Supply voltage missing Channel/component temporarily unavailable Shutdown on button activation Retentive memory in carrier module defective Retentive memory in the terminal block defective Error code Assignment Meaning Solution 10 H Module Parameter assignment does not match the terminal block used Incorrect parameter assignment 11 H Module Missing or insufficient supply voltage L+ 1F H Module Firmware update is currently in progress or has been canceled. The module does not output any process or substitute values in this state. 122 H Module The output disable switch was activated 154 H Module An error of the memory block on the adapter module was detected during startup 155 H Module An error of the memory block on the terminal block was detected during startup Correct the parameter assignment Check terminal block 1 Check the supply voltage L+ on the terminal block Restart firmware update Wait for firmware update Pull and plug module Replace carrier module Replace terminal block 1 Only the terminal blocks (TB 45...) are suitable for operating I/O modules with IO redundancy. Maintenance events A maintenance event is generated for each maintenance required identified. The MT LED lights up on the module. 34 Manual, 11/2017, A5E39389042-AC

Drivers, parameters, diagnostics messages and address space A.4 Diagnostics messages and maintenance events Maintenance messages have no direct effect on the function of the module or digital outputs. Table A-2 Maintenance messages, their meaning and possible remedies Maintenance message Retentive memory in carrier module defective Retentive memory in the terminal block defective Error code Assignment Meaning / Cause Solution 154 H Module Fault detected in the data block on the carrier module during operation 155 H Module An error of the memory block on the terminal block was detected during operation Replace carrier module Replace terminal block Manual, 11/2017, A5E39389042-AC 35

Drivers, parameters, diagnostics messages and address space A.5 Address space A.5 Address space [ID: 80188171403] Abbreviations "IB" stands for input byte, that is, the module start address in the input area "QB" stands for output byte, that is the module start address in the output area "DQ" stands for digital output "QDQn" stands for the value status (QI) of digital output n Address space The following figure shows the mapping of the address space of the RQ 4x120VDC-230VAC/ 5A CO HA. QB/IB 7 6 5 4 3 2 1 0 QBx 0 0 0 0 DQ3 DQ2 DQ1 DQ0 IBx 0 0 0 0 QDQ3 QDQ2 QDQ1 QDQ0 Evaluating the value status There is a bit value status for each digital output in the input address space. Irrespective of the diagnostics enables, each value status (each QI bit) provides information on the validity of the corresponding process value. Value status = 1: Process value okay, "good" Value status = 0: Process value not okay, "bad" Basically, the value status is set to "good" if the digital value can be output without error. The value status is set to "bad" in the following cases: The digital value cannot be output due to an error. The digital channel is deactivated. 36 Manual, 11/2017, A5E39389042-AC

Index A Address space, 36 C Channel fault LED, 19 Channel parameters, 16, 31 Channel status LED, 19 Conventions, 6 D Data record 128, 31 Header information, 32 DIAG LED, 20 Diagnostics interrupt, 21 Documentation Range of validity, 5 S Properties, 8 Schematic circuit diagram, 13 Technical specifications, 23 Schematic circuit diagram, 13 T Technology parameters, 31 Terminal block, 11 V Value status, 36 Evaluating, 36 L LED displays, 19 M Module parameters, 16 MT LED, 20 P Parameters, 15, 16 Pin assignment, 12 PWR LED, 20 R RQ 4x120VDC-230VAC/5A CO HA Accessories, 9 Channel parameters, 16 Functions, 8 Module parameters, 16 Parameter, 15, 16 Parameters, 16 Pin assignment, 12 Manual, 11/2017, A5E39389042-AC 37

Index 38 Manual, 11/2017, A5E39389042-AC