IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Similar documents
IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

Universal Safety Photo Eye UL MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

OPERATING INSTRUCTIONS

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Operating Instructions

INSTALLATION INSTRUCTIONS

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET

KXR20 Voltage Regulator

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

8000 Series: Installation Supplement R2-1-12

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Tempco Instruction Manual

icp installation guide

Photoelectric Sensor

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

SLM Series Slot Sensors

QAL50 Series Analog Line Sensor

Miniature Overhead Stirrer

onlinecomponents.com

DF-G2 High Speed Expert Dual Display Small Object Counter

CA-A480-A Elevator Controller. Reference & Installation Manual

T4HD: Installation Supplement R8.1.13

Photoelectric Sensor

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Vocia. Page Active Relay Module (PARM-1) Operation Manual

MAXIMA + Series ROTARY LEVEL CONTROL

AEXX-349 SERIES REMOTE DISPLAYS

KBMG MULTI-SPEED BOARD

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

General-Purpose Photoelectric Sensor

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Installation, Operation and Maintenance Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

MAXIMA+ Series Rotary Level Indicator

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Grundfos MAGNA, GENI Module

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

SafePace 600 Variable Messaging Sign

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

OZONE SWITCH Model OS-6. OS-6 Features

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

INSTALLATION INSTRUCTIONS

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

RTD SAMPLER OPERATOR S MANUAL

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

QuickTouch (QT4) Owner s Manual

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Operating instructions. Speed monitor D / / 2014

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC

Installation Instructions

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Digital Lighting Systems, Inc.

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

PCM-7140 Pulsed Current Source Operation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

5504 Thermocouple Analog Input Module

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

PMDX-170 Slotted Optical Sensor

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

THE ARIA. LED AREA LIGHT. eran industrial. ARL SERIES

87421/22A Power Supply. Operating and Service Manual

Compact Coded Magnetic Safety Interlock Switch and Control Units

MT8050iE series. Installation Instruction (1) (2)

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model DMX8DIM Installation and Operations Manual

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Specifications, Installation, and Operating Instructions

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

User Guide. Control Box. RoscoLED TM.

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

FTC-200 X-ray Tube Controller Users Manual

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Installation Instructions

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

Resolver to Digital Expansion Board

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

LED FOLDING WORKLIGHT TM

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

TSD-SEQ6 Sequencer Controller

Transcription:

O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support: technical@emxinc.com www.emxinc.com

Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Configuration settings and indicators 3 Installation 9 Verification and Operation 10 Troubleshooting 11 Ordering Information 12 Accessories 12 Warranty 12 IRB-MON Operating Instructions 1

Cautions and Warnings 1. Read and follow all operating and Installation instructions. 2. Always follow gate operator manufacturer installation instructions regarding installation of TYPE B1 sensor to the operator. 3. Disable the gate so it is unable to move. Refer servicing to qualified service personnel. IMPORTANT: This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. Product Overview The IRB-MON is a thru-beam photo eye and is an external entrapment protection device type B1, non-contact sensor for use with automatic gates and doors. The light beam is near infrared and pulses at a rate of 300/second (300Hz). The IRB-MON provides a signal to the gate or door operator that the beam is not obstructed. The operating range is up to 115ft. The IRB-MON operates over a wide range of 6-35VDC and 12-24VAC. A green alignment indicator on the receiver provides status information at a glance, making set-up and alignment easy. The IRB-MON includes 3 selectable operating configurations providing compatibility with most operators that accommodate monitored external entrapment protection devices per UL325-2016. REFER to operator installation instructions for proper configuration selection. CONFIGURATION 0 - NON-MONITORED and MONITORED Intended for use with operators that require simple relay contact activation to indicate beam obstruction. Reference Light ON/Dark ON setting. Jumper available for compatibility with Normally Open 10K termination operators. CONFIGURATION 1 MONITORED, HEARTBEAT 300Hz / 0Hz Intended for use with operators designed to accept a heartbeat form of monitoring, 300Hz when aligned, no obstruction, 0Hz when beam is obstructed. CONFIGURATION 2 MONITORED, HEARTBEAT 300Hz / 2Hz / 0Hz Intended for use with operators designed to accept a heartbeat form of monitoring, 300Hz when aligned, no obstruction, 2Hz when beam is obstructed, and 0Hz for a failure. IRB-MON Operating Instructions 2

Specifications Specifications Operating range Up to 115 ft. (35m) Detection angle 24 Sensitivity adjustment potentiometer Power indicator Green LED Detect indicator Flashing green LED Mode selection switch 3 modes: relay output, pulsed (3 frequency), pulsed (2 frequency Relay output operation Light ON/dark ON Relay output Form C contacts (NO, COM, NC) Power protection Thermal fuse Transmitter power cycle >300mS (for use in configuration 0 Monitored) Power (see Cautions and Warnings) 6 35VDC, 12 24VAC (Configuration 0 RELAY only) Current (Config. 0) 60mA (relay activated) Current (Config 1 & 2) 15mA (12VDC, includes TX and RX wired in parallel) Operating temperature -40 170 F (-40 77 C) Environmental NEMA 4X Dimensions (L x W x H) 2.3 (57mm) x 2.6 (65mm) x 3.7mm (94mm) Weight TX 0.35 lbs (159g), RX - 0.35 lbs (159g), Connections TX 2 terminals, RX 5 terminals Configuration settings and indicators CONFIGURATION SETTINGS - Remove power when changing configuration settings SW4 SW3 SW2 SW1 JUMPER FUNCTION ON OFF OFF OFF NC Configuration 0 - relay operation ON OFF OFF OFF 10K Configuration 0 Install jumper for 10K resistive termination OFF OFF OFF ON NC Configuration 1 - heartbeat output, 300Hz, 0Hz, no relay activation OFF OFF ON OFF NC Configuration 2 - heartbeat output, 300Hz, 2Hz, no relay activation ON OFF ON ON NC Configuration 0 - relay operation ON X X X NC Dark on - N.O. contact closed when beam obstructed OFF X X X NC Light on N.O. contact closed when beam is not obstructed See the following pages for detailed descriptions, switch settings and wiring GREEN STATUS INDICATOR IRB-MON-T (transmitter) ON Power IRB-MON-R (receiver) Flashing Blocked beam or not aligned IRB-MON-R (receiver) ON Aligned IRB-MON-R (receiver) OFF Receiver/Transmitter are too close See Troubleshooting Guide IRB-MON Operating Instructions 3

RESISTIVE NOTE: Remove power when changing Configuration settings NOTE: The relay contacts on the board and the references to them in these Instructions are shown in the energized state, no obstruction, Dark ON setting. IRB-MON Operating Instructions 4

WIRING DIAGRAM A N.C. NOTE: Remove power when changing Configuration settings NOTE: The relay contacts on the board and the references to them in these Instructions are shown in the energized state, no obstruction, Dark ON setting. IRB-MON Operating Instructions 5

WIRING DIAGRAM B IRB-MON Operating Instructions 6

PULSE NOTE: Remove power when changing Configuration settings IRB-MON Operating Instructions 7

WIRING DIAGRAM C TRANSMITTER WIRING IRB-MON Operating Instructions 8

Installation Install the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. DO NOT USE 12-24VAC IN PULSE CONFIGURATIONS. 1. Disconnect the IRB-MON from power before installing or servicing the device. 2. Always follow the instructions of the gate operator manufacturer regarding installation of type B1 sensors on the gate operator. The instructions of the gate operator manufacturer always supersede any instructions given in this or any other instructions by EMX Industries Inc. 3. Connect the IRB-MON power supply per requirements indicated in the specification table. 4. When using the relay outputs, do not exceed the voltage/current ratings indicated in the specification table. 5. Connect power to the terminals on the transmitter marked TX, polarity is not required. 6. Connect power to terminals marked POWER INPUT on the receiver, marked RX polarity is not required. 7. FOR CONFIGURATION 0 ONLY. Operators that require normally closed contact for entrapment protection, connect terminal NC and COM to the designated terminals in the gate operator. Operators that require normally open contact for entrapment protection, connect terminals COM and NO to the designated terminals in the gate operator. 8. Install the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 9. The IRB-MON is housed in a NEMA 4X enclosure. To insure the integrity of the enclosure make sure the covers are attached and closed tight using all four plastic screws provided. The wiring to the enclosure must enter via UL Listed watertight fitting such as a strain relief or watertight conduit connector. 10. The IRB-MON must be powered by Class 2 circuits only, wiring must be segregated from other circuits or insulation must be provided that is suitable for the highest voltage for those circuits. 11. NOTE: REDUCE SENSITIVITY (COUNTER-CLOCKWISE) WHEN INSTALLING AT <20 FT. IRB-MON Operating Instructions 9

Verification and operation Verify proper operation of the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 1. Verify that the IRB-MON transmitter and receiver in line of sight and apply power. 2. Place an obstruction (ex. hand) between the IRB-MON transmitter and receiver. The green LED on the receiver is flashing. Check the operator control board that the safety input is actuated. 3. Remove the obstruction and green LED will be on. 4. If the IRB-MON does not respond to the obstruction, lower the sensitivity by adjusting the SENSITIVITY pot counter-clockwise. 5. If the IRB-MON indicates an obstruction when there is no obstruction, increase the sensitivity by adjusting the SENSITIVITY pot clockwise. 6. Follow gate/door manufacturer s installation instructions and safety checks to verify that the IRB-MON is operating properly. IRB-MON Operating Instructions 10

Troubleshooting Symptom Possible cause Solution Does not detect obstruction Sensitivity too high Adjust SENSITIVITY pot of beam counter-clockwise Green LED flashes continuously (indicating an obstruction when an obstruction is not present) Signal is reflecting off another surface Sensitivity too low Transmitter does not have power Check area for highly reflective surfaces Adjust SENSITIVITY pot clockwise Check power source for transmitter Receiver activates but does not transmit signal to operator Receiver green LED off (1) Receiver does not see transmitter Faulty connection between receiver and operator control input Transmitter too close to receiver Make sure transmitter and receiver have line of sight alignment Verify all wires and terminal connections Adjust SENSITIVITY pot counter-clockwise Increase distance between transmitter and receiver (1) When transmitter is too close to the receiver the green LED will turn off, this prevents mounting the photo eyes in close proximity. IRB-MON Operating Instructions 11

Ordering Information IRB-MON Infrared photocell includes transmitter and receiver Accessories IRB-HD-SET IRB-SD-SET IRB-BR IRB-SP IRB-S Protective hood, aluminum, gold anodized Protective hood, steel, gray powder-coat Mounting bracket, L shape Strain relief, water-tight Nylon screws, set of 2 with nuts Warranty EMX Industries Incorporated warrants all products to be free of defects in materials and workmanship for a period of two years under normal use and service from the date of sale to our customer. This warranty does not cover normal wear and tear, abuse, misuse, overloading, altered products, damage caused by incorrect connections, lightning damage, or use other than intended design. There is no warranty of merchantability. There are no warranties expressed or implied or any affirmation of fact or representation except as set forth herein. EMX Industries Inc. sole responsibility and liability, and the purchaser s exclusive remedy shall be limited to the repair or replacement at EMX Industries option of a part or parts found not conforming to the warranty. In no event shall EMX Industries Inc. be liable for damages, including but not limited to damages resulting from non-conformity, defect in material or workmanship. Effective date: January 1 st, 2002 IRB-MON Operating Instructions 12

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America www.emxinc.com Technical Support: (216) 834-0761 technical@emxinc.com Sales: (216) 518-9888 Fax: (216) 518-9884 salessupport@emxinc.com Revision 2.5 5.31.16 IRB-MON Operating Instructions 13