Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Similar documents
DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Agilent OBSAI Protocol Tester

Firmware Guide. Keysight PXIe Chassis Family

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

Agilent Technologies E5385A 100-Pin Probe

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent 70612B K18 Switch Matrix

Agilent Gb/s Serial BERT

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Quick Start/Installation Guide

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Errata. Agilent References in this manual. About this manual. Support for your product

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

86100 Series Infiniium DCA Oscilloscope

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Add Source and Receiver Attenuators Upgrade Kit

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent CSV Export Utility

87421/22A Power Supply. Operating and Service Manual

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Agilent Softtouch 2.0 Midbus Probe

Agilent OpenLAB Chromatography Data System (CDS)

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Agilent OpenLAB. Data Store. Maintenance Guide

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent InfiniiMax II 1168A/1169A Probes

Agilent N4219B Packet Analysis Probe for Serial ATA. User s Guide

Keysight U2722A/U2723A USB Modular Source Measure Units

Agilent OpenLAB. Data Store. Backup and Restore Guide

Agilent 1260 Infinity Purification Solution

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Errata. Agilent References in this manual. About this manual. Support for your product

Keysight E7515A UXM Firmware Update Tool

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Agilent U2941A Parametric Test Fixture

BenchCel Workstations Software

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Getting Started Guide

Setting Up Probes. Online Help

* * Agilent Power Distribution Unit (PDU) Installation Guide

Agilent OpenLAB Chromatography Data System

Agilent N4880A. Reference Clock Multiplier. User s Guide

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Agilent E2094M IO Libraries

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent Series Logic Analysis System

Keysight U4431A MIPI M-PHY Protocol Analyzer. User Guide

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Keysight E4990A Impedance Analyzer

Installation and Quick Start Guide

Agilent TS-8989 PXI Functional Test System

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Advanced Test Equipment Rentals ATEC (2832)

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Agilent 16442B. User s Guide. Agilent Technologies

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Keysight E4982A LCR Meter

Cary 50. Pre-Installation Manual

Agilent Dissolution Tester Driver

Agilent N1022A Active Probe Adapter User Guide

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

Agilent OpenLAB Data Store. Maintenance Guide

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Agilent OpenLAB Chromatography Data System (CDS)

Agilent Technologies LogicWave

Agilent OpenLAB Chromatography Data System (CDS)

Keysight M9393A PXIe Vector Signal Analyzer

HP E2485A. Installation Guide. Memory Expansion Interface. Copyright Hewlett-Packard Company 1997 All Rights Reserved

RZ2 BioAmp Processor. Operator s Manual

Agilent OpenLAB Chromatography Data System (CDS)

Agilent ChemStation Plus

MC-12 Software Installation Instructions

Agilent ChemStation Plus

Agilent Connector Plate

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

RZ5/RZ5D/RZ6 Processor. Operator s Manual

Agilent E5072A Network Analyzer

Upgrading and Servicing Guide

Agilent Technologies. PXI 6½ Digit Multimeters. Startup Guide M9181A, M9182A, M9183A. Agilent Technologies

Agilent TS-5400 High Performance PXI Functional Test System

Agilent TS-8989 PXI Functional Test System

Keysight MIPI M-PHY Command Line Packet Generator. User s Guide

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Manual Version: V1.00. Video Decoder Quick Guide

Keysight 42941A Impedance Probe Kit

Agilent G6011A Quiet Cover MS

Keysight Combiner and Mechanical Switches Upgrade Kit

B63/ NS MS. EtherNet/IP LINK

Agilent 89600B VSA. Software Installation Guide

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Transcription:

Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Notices Keysight Technologies 2013-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws. Manual Part Number E5864-97001 Edition Second Edition, November 2014 Printed in Malaysia Published By: Keysight Technologies Plot No. CP-11, Sector- 8, IMT Manesar, Gurgaon - 122051, India Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as "Commercial computer software" as defined in DFAR 252.227-7014 (June 1995), or as a "commercial item" as defined in FAR 2.101(a) or as "Restricted computer software" as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Keysight Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. 2 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Safety Summary General Before Applying Power Ground the Instrument Fuses Do Not Operate in an Explosive Atmosphere Do Not Remove the Instrument Cover Cleaning Do Not Modify the Instrument In Case of Damage The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings or operating instructions in the product manuals violates safety standards of design, manufacture, and intended use of the instrument. Keysight Technologies assumes no liability for the customer's failure to comply with these requirements. Product manuals are provided with your instrument on CD-ROM and/or in printed form. Printed manuals are an option for many products. Manuals may also be available on the Web. Go to www.keysight.com and type in your product number in the Search field at the top of the page. Do not use this product in any manner not specified by the manufacturer. The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions. Verify that all safety precautions are taken. Make all connections to the unit before applying power. Note the instrument's external markings described in Safety Symbols. If your product is provided with a grounding type power plug, the instrument chassis and cover must be connected to an electrical ground to minimize shock hazard. The ground pin must be firmly connected to an electrical ground (safety ground) terminal at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury. See the user's guide or operator's manual for information about line-fuse replacement. Some instruments contain an internal fuse, which is not user accessible. Do not operate the instrument in the presence of flammable gases or fumes. Only qualified, service-trained personnel who are aware of the hazards involved should remove instrument covers. Always disconnect the power cable and any external circuits before removing the instrument cover. Clean the outside of the instrument with a soft, lint-free, slightly dampened cloth. Do not use detergent or chemical solvents. Do not install substitute parts or perform any unauthorized modification to the product. Return the product to an Keysight Sales and Service Office for service and repair to ensure that safety features are maintained. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. 3 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could resul t in personal injury or death. Do not proceed beyond a WARNING notice until the ind icated cond itions are fully understood and met. Safety Symbols Table 1 Safety Symbol Symbol Description Direct current Alternating current Both direct and alternating current Three phase alternating current Three phase alternating current Earth ground terminal Protective earth ground terminal Frame or chassis ground terminal Terminal is at earth potential Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 4

Symbol Description Equipotentiality N L Neutral conductor on permanently installed equipment Line conductor on permanently installed equipment On (mains supply) Off (mains supply) Standby (mains supply). The instrument is not completely disconnected from the mains supply when the power switch is in the standby position In position of a bi-stable push switch Out position of a bi-stable push switch Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION Caution, refer to accompanying documentation Caution, risk of electric shock Do not apply around or remove from HAZARDOUS LIVE conductors Application around and removal from HAZARDOUS LIVE conductors is permitted Caution, hot surface 5 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Symbol Description Ionizing radiation CAT I CAT II CAT III CAT IV IEC Measurement Category I Measurement Category II Measurement Category III Measurement Category IV Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 6

Compliance and Environmental Information Table 2 Compliance and Environmental Information Safety Symbol Description CSA is the Canadian certification mark to demonstrate compliance with the Safety requirements. The C-tick mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australia EMC Framework regulations under the terms of the Radio Communication Act of 1992. CE compliance marking to the EU Safety and EMC Directives. ISM GRP-1A classification according to the international EMC standard. ICES/NMB-001 compliance marking to the Canadian EMC standard. 7 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 8

Contents 1 Handling the Removable Hard Drive 2 Installing the Hard Drive Protecting Against Electrostatic Discharge (ESD) 11 Protecting Against Contamination of the Edge Connector 11 Protecting Against Physical Shock 12 Step 1. Back up data for transfer to new hard drive 14 Step 2. Power OFF the 16850 logic analyzer 14 Using the Windows Shutdown 15 Using a Short Press of the Power Button 15 Using a Long Press of the Power Button 15 Unplugging the Power Cord or Power Loss 16 Step 3. Remove the current hard drive 16 Step 4. Install the new hard drive 18 Step 5. Power on the 16850 logic analyzer 19 Step 6. Perform the first-time set up steps 19 Step 7. Perform the first-time set up proced ures 19 Step 8. Restore data 19 Step 9. Install any add itional application software 19 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 9

Contents 10 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 1 Handling the Removable Hard Drive For the integrity of the data on your hard disk drive, Keysight recommends that you take the following precautions while handling and storing the hard disk drives: Store unused hard disk drives in the shipping container. Protect the hard disk drive from electrostatic discharge (ESD). Protect the hard disk drive s edge connectors from physical contamination. Protect the hard disk drive from physical shock. Protecting Against Electrostatic Discharge (ESD) CAUTION Electrostatic discharge can damage electronic components. Use grounded wrist straps and mats when handling electronic components. Protecting Against Contamination of the Edge Connector CAUTION The hard drive edge connector is sensitive to ESD and mechanical or material contamination. Take precautions to protect the edge connector from contamination during handling and storage.

1 Handling the Removable Hard Drive Protecting Against Physical Shock CAUTION While operating, do not expose the hard disk drive to more than 5 to 500 Hz at 0.3 g rms. 12 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 2 Installing the Hard Drive Step 1. Back up data for transfer to new hard drive / 14 Step 2. Power OFF the 16850 logic analyzer / 14 Step 3. Remove the current hard drive / 16 Step 4. Install the new hard drive / 18 Step 5. Power on the 16850 logic analyzer / 19 Step 6. Perform the first-time set up steps / 19 Step 7. Perform the first-time set up procedures / 19 Step 8. Restore data / 19 Step 9. Install any additional application software / 19 CAUTION Electrostatic discharge can damage electronic components. Use grounded wrist straps and mats when handling electronic components.

2 Installing the Hard Drive Step 1. Back up data for transfer to new hard drive Step 2. Power OFF the 16850 logic analyzer 1 Close the Keysight Logic and Protocol Analyzer application software. 2 Back up any data and server license files you want to retain using LAN, USB flash drive, writable CDs, etc. Keysight recommends floating licenses for logic analyzers with removable disks (such as the 16850-series logic analyzers). If the license server is on the logic analyzer, back up the server license files which are located in the LicenseFiles folder under the license server s installation directory. For example, the default location is: C:\ Program Files\Agilent Technologies\LicenseServer\LicenseFiles\ License files have the extension.lic. You can also use node-locked licenses. However, because the logic analyzer host ID changes with the hard disk drive, you must have separate licenses on each disk. Node-locked license files are located in the License folder under the Keysight Logic and Protocol Analyzer application s installation directory. For example, the default location is: C:\Program Files\Agilent Technologies\Logic Analyzer\License\ WARNING Hazardous voltages exist on the power supply. To avoid electrical shock, disconnect the power from the instrument before performing the following procedures. After disconnecting the power, wait at least six minutes for the capacitors on the power supply board to discharge before servicing the instrument. CAUTION Damage can occur to electronic components if you remove or replace assemblies when the instrument is on or when the power cable is connected. Never attempt to remove or install any assembly with the instrument on or with the power cable connected. 1 Power off the system using one of the methods explained below. 2 Remove the power cord. 14 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Installing the Hard Drive 2 Using the Windows Shutdown On the logic analysis system desktop, click Start > Shut Down or if you are running remote desktop, click Start > Settings > Windows Security > Shut Down. This software power off does the following: Closes all programs that are running. Writes all data to the disk. Turns off the power supply. If the system is unplugged while it is off and then plugged back in, the system will not power on until the power button is pressed. Using a Short Press of the Power Button Pressing the power button on a frame for a short time (less than 2 seconds): Closes all programs that are running. Writes all data to the disk. Turns off the power supply. If the power button is depressed for a short time (less than 2 seconds or so) while another instrument has an open Remote Desktop connection to this instrument, a message on the logic analysis system screen (not on the remote desktop) will pop up asking if you really want to power down. Clicking the 'yes' button results in the above events. Clicking 'no' will prevent the shutdown and not answering the dialog box (neither clicking "Yes" or "No") will have no effect. Further short presses on the power button will have no effect. Using a Long Press of the Power Button Pressing the power button for more than 4 seconds will power the system down abruptly. Use this method only when other methods have not responded: Programs that are running will not be shut down. Any data that has not been written to the disk will be lost. Turns off the power supply. If the system is unplugged while it is off and then plugged back in, the system will not power on until the power button is pressed. If the system does not boot, the hard disk drive will need to be re-imaged. Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 15

2 Installing the Hard Drive Unplugging the Power Cord or Power Loss Step 3. Remove the current hard drive Unplugging power while the instrument is turned on or a power loss is similar to the long press of the power button with one exception: When the system is plugged back in, it will power up and boot into Windows. The 16850 logic analyzer has a removable hard disk drive. It can be removed and replaced without disassembling the instrument. 1 Loosen both the thumb screws that hold the hard disk drive in place. Thumb Screws Removable Hard Disk Drive 16 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Installing the Hard Drive 2 2 Pull the drive tray out to remove the disk drive. Removable Hard Disk Drive pulled out Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 17

2 Installing the Hard Drive Step 4. Install the new hard drive 1 Slide the new removable hard drive into the drive bay. 2 Gently press the tray all the way in to seat the disk drive connectors. 3 Tighten both the thumb screws that hold the hard disk drive in place. 18 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Installing the Hard Drive 2 Step 5. Power on the 16850 logic analyzer Turn on the logic analyzer. Step 6. Perform the first-time set up steps Step 7. Perform the first-time set up procedures If you are using the E5864A replacement hard disk as an additional bootable drive, the replacement disk is pre-configured with the operating system, frame drivers, and logic and protocol analysis application software (just like the original 16850 disk as shipped from the factory). The next step is to perform the first-time set up procedures described in the 16850 -Series Logic Analyzers Installation Guide shipped with the 16850 logic analyzer. Step 8. Restore data The next step is to perform the first-time set up procedures described in the 16850-Series Logic Analyzer Installation Guide shipped with the 16850 logic analyzer. Step 9. Install any additional application software Restore the data and server license files you backed up in Step 1. Back up data for transfer to new hard drive" on page 14. Install any additional application software. Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 19

2 Installing the Hard Drive 20 Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide

Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide 21

This information is subject to change without notice. Keysight Technologies 2013-2014 Second Edition, November 2014 *E5864-97001* www.keysight.com