INSTRUCTION/INSTALLATION SHEET lyriq Studio High Performance Keypad

Similar documents
INSTRUCTION/INSTALLATION SHEET lyriq Studio Keypad

INSTRUCTION/INSTALLATION SHEET lyriq High Performance Keypad Volume Control With IR

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad

User s Guide. Digital Whole Home Audio Distribution System. Includes 8 audio source inputs and 8 amplified audio zones

User s Guide. Digital Whole Home Audio Distribution System

D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL

AUD-340 Installation Guide

AUD-220 Installation Guide

PXR 1506 / WATT MIXER AMPLIFIER

PRE116/126. User Manual.

AMP20. User Manual.

5100 series 5.1 multimedia speaker system

OLi POWA-5 Active Monitors

Self Amplified Digital Keypad with Bluetooth and Analog Inputs MONOPRICE PID 10222

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

C-300 Preamplifier User s guide

Instruction Manual. 5.1 Channel Cinema System with Remote Wirless and Glossy MODEL:LS 250

Audio Zone Amplifier 2 x 20 watts Installation Guide

A Watt Stereo Amplifier

VOICE-ACTIVATED INTERCOM SYSTEM

THANK YOU! CR120H. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

CRASHER BLUETOOTH WIRELESS STEREO SPEAKER INSTRUCTION MANUAL

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

BRN WHT/BRM BLU WHT/BLU GRN WHT/GRN ORG WHT/ORG

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

I1000M Operation Manual

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

AD-400. CD Player with USB/SD and FM Tuner. Item ref: UK User Manual

Users Manual. Pronomic TAS-18 Active Touring System

Control Your World. Lighting Control System

Soundbar Remote Power Cable Quick User Guide Wall Mount Bracket 2 x Mounting Screws WARNING

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

Keypad KEY-2.7. Instruction Manual

VE9121 Series Classroom Audio Management System

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

Neets Control EcHo Plus. Installation Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Neets Control EcHo Plus. Installation Manual

U-150 Integrated Amplifier User s guide

U-300 Unity Amplifier User s guide

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

WA-210. Wall Mounted Amplifier with USB/FM and Bluetooth. Item ref: UK, UK User Manual. Version 1.0

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

QuickNetwork QND300 Distribution Panel

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

IT Designs Copyright All Rights Reserved. Mix-It, Mix-It2 and M logo are trademarks of IT Designs.

2.1 CH Soundbar Speaker System MODEL: STUDIO UHD2. Instruction Manual PLEASE READ REFORE OPERATING THIS EQUIPMENT.

DM25, DM40. Compact 100V mixer-amplifiers with Bluetooth. Item ref: UK, UK User Manual

KP7 Keypad Quick Install Guide

PS8 - II. Professional Power Sequencer. User s Manual

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top)

Speaker Selectors Models SSW-4 and SSW-6. User Manual

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

PCM60A 100W MAX P.A. AMPLIFIER.

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

LTD East 5th Street Superior, WI USA tel: fax:

Blonde On Blonde OWNER S MANUAL SWR SCOTTSDALE, AZ USA

WELCOME SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS. MRKP1E Keypad controller EU and UK Standard

POWER MANAGEMENT Power Supplies

Section. Placing onlocation

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button

THANK YOU! Crush PiX 20L. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

VM SERIES Rackmount 100V mixer-amplifiers

CR6S Stereo Micro Crush

XENO 8. User & Installation Manual.

Wireless Audio Soundbar

IMPORTANT! USER MANUAL. LPU192CD Hi-Fi Turntable Stereo System WARRANTY INFORMATION INSIDE. PLEASE READ.

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

Stereo - Amplifier. User s Manual

AB-910W. A-Bus Two Zone Audio Kit w/bluetooth & 2 pair In-Wall Speakers. Intelligent Entertainment Infrastructure Security Solutions CHANNEL VISION

Model #28599 Wireless Bluetooth Surround Bar & Subwoofer 285W

Blue Point Engineering

HP-101 HEADPHONE AMPLIFIER

QuickNetwork QND200 Distribution Panel

HRS-1S. Half Rack Analog Stereo Audio Speaker Monitor. User Guide. Part Number , Revision E

Universal Docking Station with 2.4GHz Wireless Speakers for iphone/ipod

INSTALLATION INSTRUCTIONS

OWNER S MANUAL CD-2 V 1.3

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

SUBWOOFER SYSTEM YST-MSW10

MODEL 805 USER MANUAL

ple420p 4KHz 6KHz 15KH power in-dash 4 band parametric equalizer

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

AB-315. ibus Wall-Dock for A-Bus Audio Systems

HD View 12 Plus and HD View 6

MXA2080. Stereo Power Amplifier. Owner s Manual

Bluetooth integrated amplifier. USER Guide Model s GDI-BTAR122 & GDI-BTAR502

USER MANUAL ENGLISH. itube 452. Amplifier 2 x 45Watt FATMAN. TLAudio

MT /12-Slot Digital MultiTasker

DAB A d a pt e r 3+ Dear Customer,

U S E R M A N U A L. Pod3. Copyright 2007 IPE Music

TVA2.1 2-Channel Digital Amplifier Installation Manual

Siemens Energy & Automation. structured. WIRING Product Training Series: Hi-Fi Whole Home Audio Session 4

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

INSTALLATION INSTRUCTIONS. MRKP1 Keypad controller North American Standard. Safety Information

Transcription:

1. Introduction The, P/N AU5010-xx (see Figure 1), is an integral part of the lyriq Multi-Room Audio System. It is a component which, when combined with other essential components (a Source Input Unit, Distribution Module and Speakers) and your source equipment (receiver, CD player, etc.), creates a versatile whole-house audio system that will fill your rooms with highquality sound for years to come. It uses Category 5 wiring to distribute audio signals, control information and IR for remote control. The High Performance has two on-board 20 Watt per channel class D amplifiers to provide a rich level of clean sound even in large room applications. It also contains a full set of features, including the ability to control all other keypad volume controls in the house. Build a system that accommodates the needs of any space by combining the with the lyriq Studio (P/N AU5009-xx) in the same system. The AU5010-xx is available in white (-WH), light almond (-LA), titanium (-TI), or gloss black (-GB). 2. Description The front panel of the, PN AU5010-xx (see Figure 1), looks almost identical to the standard lyriq Studio (AU5009-xx). It also has push buttons for STANDBY (backlit with red LED when in Standby Mode), for MUTE (backlit with red LEDs, when Mute function is selected), VOLUME UP/DOWN (with six associated blue Volume Bar Graph LEDs), SOURCE SELECT (with six blue Source Selection LEDs), and WHOLE HOUSE (backlit with white LEDs when not selected and with flashing blue/white LEDs when Whole House function is selected). There is also an IR target window. The visual cue from the front panel that this is a High Performance Volume Control are the parenthesis surrounding the music note on the lower left corner of the display area. Figure 1 NOTE: lyriq s are recommended for indoor use only. On the rear of the (see Figure 2) the Category 5 connection is an RJ45 jack (J1). The TB2 speaker output connections (left and right, plus and minus) are spring loaded and designed to support up to 14 gauge wire. The TB3 Line Out connections (plus and minus) are also spring loaded and designed to support up to 14 gauge wire. This mono-summed output is designed for powered sub-woofers and as such is filtered through an 80Hz low pass filter. The other terminal block on the rear (TB1) is used for powering the keypad. Up to 14 gauge speaker wire may be used for this purpose, and this speaker wire (two or four conductor) is run from a power distribution module (P/N AU1001) in the enclosure to the. We recommend 16/4 speaker wire, since it is available paired with Category 5 from a variety of sources. Again, the TB1 connections are spring loaded (plus and minus) with the two plus connections on the red portion of TB1 and the two minus connections on the black portion of TB1. For ease of installation, connect the red wire and white wire to the red (plus) portion of TB1 and the black and green wire to the black (minus) portion of TB1. Figure 2 Page 1 of 8

3. Installation Installation of the is best accomplished at multiple times during new construction, at Rough-in before the drywall is installed, and at Trim-out after the drywall is installed and painted. NOTE: Before connecting the volume controls: Make sure that power supplies are not connected to the lyriq Audio and Power Distribution Modules. For instructions on pre-wiring and installing other components of the lyriq Audio System, please see the Instruction Sheets included with those components. NOTE: Always follow TIA-570-B and T568A wiring standards for installing and terminating Category 5 cable. Failure to follow the correct wiring standard could result in damaged equipment and/or electrical interference issues. Carefully label each wire for its intended use to avoid mis-wiring. NOTE: Maintain a minimum 12 separation between Category 5 cable and any 120VAC cabling. A. Rough-in steps: 1) A single Category 5 cable and 16/4 speaker wire should be run from the enclosure location to a single gang outlet box at each Volume Control location (typically mounted at electrical light switch height). B. Trim-out steps: 1) Connect the volume control by terminating the pre-wired Category 5 cable from the enclosure with an RJ45 plug, following the T568A wiring standard and insert this plug into jack J1 (see Figure 2). 2) For the power connection (TB1) strip 3/8 of insulation from each of the four conductors and insert the red and white wires into the red (plus) portion of TB1. Insert the stripped black and green wires into the black (minus) portion of TB1 (see Figure 2). NOTE: The two red connections are tied together, as are the two black connections. They are provided in pairs to provide flexibility of wiring. NOTE: Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus. That wiring will also work, as long as it is also followed at the other end of the cable (at the Power Distribution Module in the enclosure). 3) Speaker/Line Out/Sub-Woofer connections (see Figure 2): NOTE: Polarity and channels are clearly marked (L+, L-, R-, R+) for proper identification during installation. a) Use TB2 to connect one pair (only) of 8 ohm evōq audio speakers to the volume control. b) Use TB3 to connect your evōq powered sub-woofer or an external amplifier to the volume control. These connection terminals do not provide any amplification but the volume control on the keypad Page 2 of 8

controls the output level of this connection. 4) Connections in the enclosure (see Figure 3 ): a) The Category 5 cable that was run to each volume control location should be terminated with an RJ45 plug according to the T568A wiring standard and inserted into one of the zone output jacks of the associated lyriq audio distribution module. Figure 3 b) For the 16/4 speaker wire power cable that was run to each volume control location, strip 3/8 of insulation from each of the four conductors and insert the red and white wires into the red (plus ) portion of TB1. Insert the stripped black and green wires into the black (minus) portion of TB1 NOTE: As noted before, Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus. That wiring will also work, as long as it is also followed at each end of the cable. c) To connect more than eight (8) s to a 4 Source 8 Zone Module, cascade Single Source Modules. To cascade a Single Source Module, simply run a Cat 5e jumper from any Zone port RJ45 jack on the front panel of the Multi-source Module to the Source In RJ45 jack on the front panel of a Single Source Module (see Figure 4). Page 3 of 8

Figure 4 5) Mounting: check all connections and test the system s operation before installing the volume controls into the wall. Use the included screws to install the volume control and wall plate into the single gang box. NOTE: A 20 cubic inch or larger single gang box is recommended. Page 4 of 8

4. Operation A. ON/OFF: Press STANDBY button to toggle ON or OFF (see Figure 5). Remote After pressing On-Q button, press On/Off button to toggle ON or OFF (see Figure 6). B. Power-Save Mode: only After 30 seconds of inactivity, the will go into Power-Save or sleep mode. Pressing any button on the will awaken it from this mode, performing the action associated with the button push. C. SOURCE select: Press SOURCE rocker switch up (right side) or down (left side) to select desired source (see Figure 5). Remote Press SOURCE UP or DOWN button to select desired source (see Figure 6). NOTE: ( or Remote) For Single Source Systems, source toggles between source #1 and any connected Studio Local Source/s. For Multi-Source Systems, source toggles between 1, 2, 3, 4 and connected Studio Local Sources. If more than one Local Source is connected, they are indicated by L and 2. NOTE: Upon source change, volume mutes and then ramps back up to prior volume setting automatically. Standby IR Target Source LEDs Whole House On-Q Universal Remote (P/N AU1060) Figure 5 Mute Volume s/ LEDs Source On-Q Figure 6 D. VOLUME Steps: or Remote Press VOLUME + (Up) or VOLUME (Down) button (36 steps). E. MUTE: or Remote Press MUTE button to toggle Mute On or Off. NOTE: When returning from MUTE, volume control will ramp to premute or adjusted state (source, volume and backlight level). F. DO NOT DISTURB (see Figure 5): When the is off, pressing MUTE toggles Do Not Disturb (DND). This mode is indicated by both the red POWER and MUTE LED on. When is in DND mode, it will Not respond to whole house commands from other locations. G. WHOLE-HOUSE Mode (see Figure 5): NOTE: In this mode, every operation performed on this keypad will be relayed to all keypads not in (DND) mode in the system. or Remote Press the WHOLE HOUSE button to toggle the Whole House function On or Off (On the, the WHOLE HOUSE Local Whole House On/Off Room Page 5 of 8 Source s i Volume s Mute

button turns blue). In this mode, all functions performed on the local keypad such as Volume Up/Down, Mute/Un-Mute, Source selection, or Power On/Off are relayed to and performed on all active keypads in the system. NOTE: The Whole-House mode will be exited when the user fails to press a key within 10 seconds or by pressing the WHOLE HOUSE button again. H. DIMMING set-up: Press Volume+ and Volume- at the same time to enter mode. Backlights will flash. Press + or to adjust level of light. I. POWER UP SELF TEST (see Figure 5): only When power is applied to the Studio, the following start up test will occur: 1) The white backlight LEDs will illuminate to full intensity. 2) The MUTE button backlight will transition to red and back to white. 3) The WHOLE HOUSE button backlight will transition to blue and back to white. 4) The volume indicator LEDs and then source indicator LEDs will illuminate left to right and then back to the left. 5) The white backlight LEDs will dim to off and the Standby button will be backlit red. 6) When done, the powers down, NOTE: The first 5 power up self tests will take about 15 seconds, and about 2 seconds after that. Hitting any button during the test will interrupt the test and the will operate as normal. 5. Important Safety Precautions: Read the instructions that are included with all associated lyriq Audio products before installing any single component. If you are unsure of any of the installation procedures contact On-Q/Legrand Technical Support @ 1-800-321-2343 option 1 or contact an On-Q/Legrand installer. Do not attempt to service, move or change any component of the lyriq Audio system unless you are qualified to do so. This system should be installed by a qualified installer and must conform to all local building and electrical codes. Do not apply power to the lyriq Audio System until all components are installed and wiring is properly terminated. Do not attempt to terminate, change or un-install any wiring without first turning off power to the lyriq Audio System located in the Enclosure. Unplug the power to the lyriq Audio System from the power outlet before proceeding with wiring terminations or changes. Install all system components away from heat sources such as HVAC ducts/registers, stoves or any other heat source. Do not expose any component that was designed for indoor use to moisture. Doing so can create electrical hazards or render the component unusable. Exposure to moisture will also void the warranty on the system. Do not use vacuum cleaners, liquid or aerosol cleaners to clean system cover plates. A damp cloth may be used. 6. Installer Set Up Mode (see Page 7 and 8) Page 6 of 8

STUDIO KVC Installer Setup Mode MTM-03/15/09 Activate by pressing the following key sequence (while on): MUTE, VOLUME UP, VOLUME DOWN, VOLUME DOWN, MUTE, VOLUME UP, VOLUME DOWN, VOLUME DOWN The KVC will indicate Installer Setup Mode by blinking its backlight LEDs. SETTING FUNCTION OPTIONS WHOLE HOUSE ENABLE/DISABLE TURN ON VOLUME MAXIMUM VOLUME Enables or disables this KVC s ability to respond to whole-house commands from other KVC s in the system Sets the turn on volume for this KVC. Alternatively, the KVC can be set to remember its last volume when it is turned on. Sets the maximum allowed volume for this KVC. ENABLED: (DEFAULT) This KVC may be controlled by whole house commands from other KVC s. DISABLED: This KVC will not respond to whole house commands from other KVC s. SPECIFIED VOLUME: (DEFAULT) The displayed volume setting is the turn on volume. LAST VOLUME: When this KVC is turned on, it will be set to its last volume. SPECIFIED VOLUME: (DEFAULT) The displayed volume setting is the maximum volume. IR TARGET & IR REPEAT ENABLED / DISABLED Controls the setting of this KVC s IR functionality IR TARGET ENABLED / IR REPEAT ENABLED: (DEFAULT) The KVC will process received IR commands and repeat any received IR throught the system. IR TARGET ENABLED / IR REPEAT DISABLED: The KVC will process received IR commands, but will NOT repeat any received IR throughout the system. This setting may be used to prevent IR noise at this KVC from effecting the rest of the system. IR TARGET DISABLED / IR REPEAT DISABLED: The KVC will not process any received IR commands. This setting may be used in extremely noisy IR environments to prevent audible noise. MIDPOINT: (DEFAULT) Equal balance between left and right. BALANCE Adjusts the left/right balance of this KVC s audio. to the left. FULL LEFT: Audio is balanced completely FULL RIGHT: Audio is balanced completely to the right. NOTE that other settings are available between the maximums. Page 7 of 8

SETTING FUNCTION OPTIONS GROUPING Allows the Integration Module to properly control multiple KVC s that are cascaded from an AU1002 Four Source, Eight Zone Distribution Module or an AU1014 Advanced Single Source Module. NO GROUPING: (DEFAULT) This KVC is not part of a cascaded group. This is also the proper setting in a non-integration Module system. GROUP MEMBER: This KVC is a member of a cascaded group, but is not the master. As such, it will not respond to an Integration Module s status queries. GROUP MASTER: This KVC is a member of a cascaded group and is the group master. As such, it is the only KVC in the group that will respond to an Integration Module s status queries. IR REPEATER PATTERN Sets the pattern that this KVC will use when repeating IR commands to the rest of the system. The KVC allows for different patterns based on the selected source (1-4). The pattern selected here will be for the source that was selected when Installer Setup Mode was activated. 40 khz FREQUENCY: This KVC will repeat IR commands using a 40 khz pattern. MIXED 40 khz/56 khz FREQUENCY: (DEFAULT) This KVC will repeat IR commands using a mixed 40 khz / 56 khz pattern. 56 khz FREQUENCY: This KVC will repeat IR commands using a 56 khz pattern. AUTOMATIC POWER OFF WHOLE HOUSE BUTTON ENABLED / DISABLED IR ACTIVITY FEEDBACK Determines whether this KVC will automatically power off after 20 minutes of audio loss. Determines if the whole house button on this KVC is operational. Allows the KVC to indicate the presense of IR activity by blinking its power led. ENABLED: (DEFAULT) This KVC will automatically power off after 20 minutes of audio inactivity. DISABLED: This KVC will never automatically power off. ENABLED: (DEFAULT) This KVC can control other KVC s in the system after pressing its whole house button. DISABLED: This KVC cannot activate whole house mode through the use of its whole house button. ENABLED: This KVC will show IR activity by blinking its power led. DISABLED: (DEFAULT) This KVC will not show any indication of IR activity. RESTORE DEFAULT Allows the user to reset the KVC s settings to their defaults. ACTIVATED: Pressing either volume button on this setting resets the defaults and blinks the leds to indicate. Page 8 of 8