MicroContamination Solutions, Inc. P.O. Box 6897, Incline Village, Nevada 89450

Similar documents
A smart system with an easy touch APC SmartTouch. Airborne Particle Counter

PARTICLE MEASUREMENT IN CLEAN ROOMS.

Obtaining the Weld Quality You Need. What to Look for in a Cleanroom Welding Contractor

SECTION CLEANROOM CERTIFICATION

A course entitled. Particle counting to ISO Parts 1& 2

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Cable Particulation Study for Cleanroom Environments. White Paper

Air Technology Division

Test report. Evaluation of particle generation from a chair for use in cleanrooms

Airborne Particle Monitoring: Impact of ISO Calibration

CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION

FS209E and ISO Cleanroom Standards

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

FS209E and ISO Cleanroom Standards

Introduction to Contamination Cotitrol and Cleanroom Technology Matts Rarnstorp copyright 0 WXLEY-VCI.? Verlag GmbH, 2000

Cleanroom Standards CLEANROOM TUTORIAL PROGRAMME CLEANROOM CLASSES ISO CLEANROOM STANDARDS (SEP 05)

HARBEC Inc Ontario, NY

HOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT

CHANGES TO THE STANDARD FOR ISO ISO Cleanrooms and Associated Controlled Environments

CI-150 Series. Airborne Particle Counters

Cleanroom Certification Report

WHITEPAPER CLEAN ROOM DESIGN AND THE ROLE OF FLOORING. An overview of cleanroom design and flooring considerations to ensure regulatory compliance.

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

The modular application of the cleanroom solutions for manufacturing facilities

Summary of Findings. Living Room with standard 1 filter. Initial Test in Living. 4 months later in Living Room with CirrusAir

SOLAIR Portable. Airborne Particle Counters 2017/11/09

MECHANICAL CONTRACTORS ASSOCIATION OF AMERICA, INC. CLEANROOM PIPING AND PROCEDURES BASIC CONSIDERATIONS

Changes to GMP force cleanroom re-classifications

This document is a preview generated by EVS

CLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES

Understanding Particle Counter Technology and the risks of data integrity of particle counts. by Jason Kelly

Cleanroom manufacture and online supplies

Cleanrooms and associated controlled environments. Part 14: Assessment of suitability for use of equipment by airborne particle concentration

Handheld P A R T I C L E C O U N T E R S

Cleanroom Suitability Assessment of Equipment according to upcoming ISO standards. Frank Buerger, Fraunhofer IPA, October 10 th 2013, Dresden

Handheld P A R T I C L E C O U N T E R S

USER MANUAL Video Particle Counter with built in Camera Model VPC300

FEDERAL STANDARD 209E FOR CLEANROOM - AN OBSOLETE DOCUMENT!

Ease of Use. Data at Your Fingertips LMS PHARMA

Handheld P A R T I C L E C O U N T E R S 2017/11/10

Technical Review: European GMP Annex edition

Professional Resources Catalog

Hardwall & Softwall Cleanrooms

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Features. 400LXR Series Linear Motor Tables. 400LXR Series

Agenda. Scope ISO IS : Flowchart. IS : Flowchart. Onderbouwd inschatten en rekenen aan cleanrooms

I3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing

Press release. High-purity positioning systems for demanding applications. Assembly in Schneeberger's cleanroom

APRIL 2010 VOL. 13 NO. 4. Modular Cleanrooms for Business Startups and New Product Development

ACS Series. Mechanical-Bearing Rotary Stage. Integral pneumatic ER collet chuck or 3-jaw gripper. Clear aperture for product feed-through

Cleanroom Design. Second Edition W. WHYTE. JOHN WILEY& SONS Chichester New York Weinheim Brisbane Singapore Toronto. Edited by

Fluke 983. Users Manual. Particle Counter. 99 Washington Street Melrose, MA Phone Toll Free

REGULATORY COMPLIANCE. Each device complies with the EMC Directive 2004/108/EC and is CE marked

Genesis MX STM-Series

Dust Monitors: Optical Particle Counters: Differential Pressure Recorders: 81

ISO INTERNATIONAL STANDARD

Spectrum S-920N-C Cleanroom Series

Automotive Electronics Council Component Technical Committee

GT-321 HAND HELD PARTICLE COUNTER OPERATION MANUAL

Reliable Environmental Monitoring Systems by Design

icountlcm20 Fluid Condition Monitoring

Cleanrooms and Standards The Road Ahead

Energy Saving in Cleanrooms

From Standards to Practice: Sterile Respirator Hoods

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly!

The Effectiveness of Air Showers in the Contamination Control Process

Get Instant Access to ebook Iso Pdf PDF at Our Huge Library ISO PDF PDF. ==> Download: ISO PDF PDF

CLEAN ROOM PROTOCOL AND WAFER HANDLING

PowerMax-Pro USB and RS Sensors

PREPARE PROBE FOR CLASS 10 CLEANROOM

Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

VDMA OPPI Seminar Polymer material handling solutions for medical products. Srikanth, , motan India

User Manual. ParticleScan CR ParticleScan Pro

PowerMax-Pro kw Sensors

QUALITY CONTROL AT THE TTF CLEANROOM INFRASTRUCTURE FOR CAVITY - PROCESSING

Why Epson Robots? Leading Epson technology. What you need, when you need it. Intuitive programming software. Reliability you can count on

Get Instant Access to ebook Iso PDF at Our Huge Library ISO PDF. ==> Download: ISO PDF

Technical Specification

The Environmental Manager of Pharma S.A. needs a solution to monitory and control the contamination in Pharmaceutical Cleanrooms.

IOM Personal Sampler

10 COMMON TRAPS IN DESIGNING A CLEANROOM

PALBAM Class WAFER CASSETTE

F 470 LASER GLASS SCRIBER

Specific Accreditation Criteria

Building Cleanrooms. - Regulations, Air-Handling, Design & Construction -

PM2.5 and PM10 Monitors , & Instruction Manual

A Basic Introduction to Clean Rooms

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 3: Test methods

PointWrite Touch Module User Manual

0.1 Slow Monitoring and Recording System

CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION

Linear Servo Motor Driven

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

Modular CLEANROOM Solutions

TRANSFER THE QB/T FROM THE OPTICAL TABLE TO VERTICAL MANIPULATOR

Component List. Standard. Optional Extras. Consumables ITEM MODEL QTY. Main Unit Power Cord (with NEMA plug) - 1

Transcription:

To: Jeff Winters, Michael Freier From: Edward Vitenberg Subject: MultiMetrixs End-Effector Cleanliness Test Report Date: October 4, 2002 I. Overview MultiMetrixs End-Effector Cleanliness Test Report For the test performed within Front End System Minienvironment on October 3, 2002, at IRSI facility in Santa Clara, we had the following objective: Provide additional evaluation and acquire airborne particulate data in a close vicinity of critical moving components of MultiMetrixs edge-gripping end-effector IEG 300 during a cleanliness test based on ISO 14644 Standard guidelines in order to analyze this end-effector s performance. Particles 0.1 micron were measured. Our MetOne particle counter automatically segments particles into 6 size thresholds: 0.1, 0.2, 0.3, 0.5, 0.7, and 1.0 micron. All air samplings were done at a flow rate of 1 cubic foot per minute (cfm), which is the flow rate typically used for cleanroom certifications. Also, our MetOne particle counter automatically printed out the results of particulate cleanliness test and two rolls of continuous consecutive printouts are available for your reference. II. Test Facility As mentioned above, the test was performed within the Front End System Minienvironment unit placed in a regular non-classified room at IRSI facility in Santa Clara. The Minienvironment has an integrated ULPA filtration system combined with MCS proprietary diffusion panel that is sealably covering 100% of the internal cross-section. Thus, the internal background targets were met without any additional portable cleanroom even in the challenging and otherwise inappropriate ambient conditions. III. Test Equipment and Materials All test equipment devices were within current calibration, all self-diagnostics were within the specified ranges. The following test equipment and materials were used during the test: MetOne Laser Particle Counter, Model A2100B, 1 cfm sampling, 0.1 µm minimum threshold. Clear vinyl plastic film. Cleanroom tape. Isopropanol alcohol. Cleanroom wipes. 1

IV. ISO 14644 Test Procedure While Federal Standard 209E established by SEMI (Semiconductor Equipment and Materials International) specifies that the cleanliness Class 1, the most restrictive in the recent past, allows no more than 35 particles of a 0.1 micron size per cubic foot of air, the ISO (International Organization for Standardization) provided substantially more stringent requirements in an ISO 14644 Standard that specifies the following limits: ISO Class 1 limit of 10 particles of a 0.1 micron size per 1 cubic meter of air or the limit of only 0.283 particles of a 0.1 micron size per cubic foot of air. ISO Class 2 limit of 100 particles of a 0.1 micron size per 1 cubic meter of air or the limit of only 2.83 particles of a 0.1 micron size per cubic foot of air. ISO Class 3 limit of 1000 particles of a 0.1 micron size per 1 cubic meter of air or the limit of only 28.3 particles of a 0.1 micron size per cubic foot of air. According to Standard ISO 14644, the use of sequential sampling procedure is recommended to dramatically reduce sample volumes and sampling times required to verify designated particle concentration limits. In order to comply with ISO Class 1 requirements, at least 14 sequential samples of 1cfm of air must be taken from the same location with no (or zero) counts of particles of a 0.1 micron size or above. Therefore, since we have ultimately targeted the robot and end-effector compliance with ISO Class 1 requirements, during this test we were repeatedly acquiring from each same location 14 sequential samples of 1cfm of air. As mentioned above, in order to comply with ISO Class 2 requirements, a 1 CFM sample should contain less than 3 particle counts of a 0.1 micron size or above. V. Airborne Particulate Cleanliness Test for MultiMetrixs Edge-Gripping End-Effector IEG 300 Our test was continued on October 3 with MultiMetrixs edge-gripping end-effector. Upon purging and background static counts check-up resulting in 7 sequential 1 cfm samples with ZERO particle counts, we went ahead with our dynamic test. a) MultiMetrixs Gripper Test #1 (without wafer) For this test, the end effector s fingers were repeatedly actuating performing clamp-unclamp motion 33 times per minute. The airborne sample probe was attached in close vicinity of a front actuating finger (1/4 below the end-effector) as shown in FIG. 1 on page 3. Fifteen sequential 1 cfm samples were taken at this position with ALL ZERO particle counts in a row. Hence, it passes ISO1 requirements. 2

FIG. 1 b) MultiMetrixs Gripper Test #2 (without wafer) For this test, the end-effector was flipped 90º and the end effector s fingers were still repeatedly actuating performing clamp-unclamp motion. The airborne sample probe was attached 1/2 below the cutout in the gripper s body, through which a rear gripping finger is protruding as shown in FIG. 2. Upon purging and background static counts check-up resulting in 7 sequential 1 cfm samples with ZERO particle counts, we went ahead with our dynamic test. Multiple sequential 1 cfm samples were taken at this position. FIG. 2 3

Two rounds of 14 sequential 1 cfm samples and one additional round of 7 sequential 1 cfm samples were taken at this probe position as shown in FIG. 2 above. The following data table shown in FIG. 3 illustrates airborne particle counts acquired during this phase of our test. Number of 0.1 µm particles per 1 CFM during 14 minute round 1 st round 0 0 0 0 0 0 0 0 0 0 2 1 2 2 ISO2 2 nd round 0 0 0 0 0 0 1 0 0 5 0 0 0 1 ISO2 3 rd round 0 0 0 0 0 0 1 ISO2 FIG. 3 Since the particle counts acquired at this probe position were encouragingly close to comply with ISO1 requirements, we decided to continue cleaning the minienvironment up and perform additional background verification. After obtaining 16 sequential 1 cfm samples with ZERO particle counts in a static mode, we continued the dynamic counts acquisition. As on can see from the data table shown in FIG. 4, the particle counts were in compliance with ISO Class 1 requirements two times in a row. Number of 0.1 µm particles per 1 CFM during 14 minute round 1 st round 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ISO1 2 nd round 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ISO1 FIG. 4 c) MultiMetrixs Gripper Test #3 (with wafer on) For this test, the end-effector was flipped 90º back to horizontal position, and the wafer was placed on the end-effector. The airborne sample probe was attached in close vicinity of a front actuating finger (1/4 below the end-effector) as shown in FIG. 5. FIG. 5 4

Upon purging and background static counts check-up resulting in 7 sequential 1 cfm samples with ZERO particle counts, we went ahead with our dynamic test. For this test, the end effector s fingers were repeatedly actuating performing clamp-unclamp motion 33 times per minute. Fifteen sequential 1 cfm samples were taken at this position with ALL ZERO particle counts in a row. Hence, it passes ISO1 requirements again with wafer on. d) MultiMetrixs Gripper Test #4 (with wafer on) The probe was replaced to the rear fingers with wafer still on as shown in FIG. 6. FIG. 6 Upon purging and background static counts check-up resulting in 12 sequential 1 cfm samples with ZERO particle counts, we continued our dynamic test. We weren t able to see results that complied with ISO1 at this time. As on can see from the data table shown in FIG. 7, the particle counts for this test with wafer were in compliance with ISO2 requirements with 7 sequential ZERO counts samples. Number of 0.1 µm particles per 1 CFM during 17 minute round 0 0 4 0 0 0 0 0 0 4 0 0 0 0 0 0 0 ISO2 FIG. 7 5

VI. Conclusion These tests demonstrate that cleanliness performance of MultiMetrixs edge-gripping endeffector was significantly improved comparing to the previous test held on August 7 (see our report dated August 12) with ISO1 achievement vs. Federal 209E Class 1 or ISO3 obtained previously. Sincerely, Edward Vitenberg, MCS, Inc. 6