Fuel Cell Preparation. The anode supported SOFC studied was Ni-YSZ/YSZ/LSM-

Similar documents
Three-Dimensional Analysis of Solid Oxide Fuel Cell Ni-YSZ Anode Interconnectivity

Advanced materials research using the Real-Time 3D Analytical FIB-SEM 'NX9000'

Simulation and Prediction of 3-D Microstructural Evolution of Ni Cermet Anode

Quantification of Ni-YSZ Anode Microstructure Based on Dual Beam FIB-SEM Technique. Sakyo-ku, Kyoto , Japan. Bunkyo-ku, Tokyo , Japan

Marco Cantoni, Pierre Burdet

Removing Aluminum Cap in 90 nm Copper Technology

MicraGEM-Si A flexible process platform for complex MEMS devices

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Improvement of the correlative AFM and ToF-SIMS approach using an empirical sputter model for 3D chemical characterization

FEI Helios NanoLab 600 TEM specimen prep recipe Nicholas G. Rudawski (352) (office) (805) (cell) Last updated: 07/16/18

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

The digital twin in STAR-CCM+ Automated design optimization of fuel cells

The Electrochemical Innovation Lab X-ray Suite: from macro- to nano-ct

ACCURATE TEXTURE MEASUREMENTS ON THIN FILMS USING A POWDER X-RAY DIFFRACTOMETER

SWING ARM OPTICAL CMM

ION BEAM MILLING SYSTEM FOR TEM, SEM AND LM PREPARATION. Leica EM RES102

Crystal Quality Analysis Group

SEM topography. Live quantitative surface topography in SEM

Nondestructive Nanoscale 3D Elemental Mapping and Analysis of a Solid Oxide Fuel Cell Anode

Reconstruction of atomic force microscopy image by using nanofabricated tip characterizer toward the actual sample surface topography

Defect Repair for EUVL Mask Blanks

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

MICROTOPOGRAPHY THE PHOTOGRAMMETRIC DETERMINATION OF FRICTION SURFACES

AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER

SHELBY COUNTY SCHOOLS: GEOMETRY 1ST NINE WEEKS OCTOBER 2015

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

Mu lt i s p e c t r a l

Focused Ion Beam (FIB) Circuit Edit

Post-Process Process CMOS Front End Engineering With Focused Ion Beams

ULTRAVISION 3.7R21. Product Bulletin. UltraVision, a complete UT and Phased Array inspection package!

ksa MOS Ultra-Scan Performance Test Data

Supporting Information for Critical Factors of the 3D Microstructural Formation. in Hybrid Conductive Adhesive Materials by X-ray Nano-tomography

Measurements using three-dimensional product imaging

Understanding FFT- based algorithm to calculate image displacements with IDL programming language Cynthia Rodriguez University of Texas at San Antonio

The same X-ray transparent in situ pouch cell design and sample holder plates were used for both 2D

Image Acquisition Systems

SEM Drift Correction. Procedure Guide

CARBON NANOTUBE FLAT PLATE BLACKBODY CALIBRATOR. John C. Fleming

MEDICAL IMAGING 2nd Part Computed Tomography

Increasing laser processing efficiency using multibeam and tailored beam profiles

3D-Analysis of Microstructures with Confocal Laser Scanning Microscopy

Image Processing, Quantification and Model Reconstructions in SEM/FIB

Error Detection and Correction Methodology for Laser Milling Processes on Biocompatible Ceramic Materials

Tomography. Introduction to Tomography TEM Tilt-Series Tomography in Life Science STEM Tomography in Materials Science

QUALITY ASSURANCE OF MULTIFIBER CONNECTORS

Supporting information for: BOCS: Bottom-up Open-source Coarse-graining. Software

Focused Ion Beam Micro Machining and Micro Assembly

3D Computed Tomography (CT) Its Application to Aerospace Industry

Real-time quantitative differential interference contrast (DIC) microscopy implemented via novel liquid crystal prisms

Supporting Information

Micro Cutting Tool Measurement by Focus-Variation

Supporting Information: FIB-SEM Tomography Probes the Meso-Scale Pore Space of an Individual Catalytic Cracking Particle

Review of paper Non-image-forming optical components by P. R. Yoder Jr.

Using ANSYS and CFX to Model Aluminum Reduction Cell since1984 and Beyond. Dr. Marc Dupuis

METHOD FOR DETERMINING WAFER FLATNESS USING THE MOVING AVERAGE QUALIFICATION METRIC BASED ON SCANNING LITHOGRAPHY

Selective Space Structures Manual

NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS

Optimizing Lift-Out. Cheryl Hartfield. Senior Applications Specialist, Omniprobe

Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections

On the importance of FIB-SEM specific segmentation algorithms for porous media

Scanning Capacitance Microscopy Investigations of Focused Ion Beam Damage in Silicon

OPSE FINAL EXAM Fall CLOSED BOOK. Two pages (front/back of both pages) of equations are allowed.

3D Field Computation and Ray-tracing

Volume visualization. Volume visualization. Volume visualization methods. Sources of volume visualization. Sources of volume visualization

Supporting information SI 0: TEM & STEM acquisition parameters, in 2D and 3D

Three-Dimensional Laser Scanner. Field Evaluation Specifications

SUPPLEMENTARY INFORMATION. Plasmonic black gold by adiabatic nanofocusing and absorption of. light in ultra-sharp convex grooves

Leica EM TXP. Target Surfacing System

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

LEICA EM TXP. Target surfacing system

WETTING PROPERTIES OF STRUCTURED INTERFACES COMPOSED OF SURFACE-ATTACHED SPHERICAL NANOPARTICLES

ULTRASONIC INSPECT ABILITY MODELS FOR JET ENGINE FORGINGS

HARP-NEF Front End Assembly

Supporting Information

Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time

Advanced method for the accurate measurement of tilt angle in a transmission electron microscopy goniometer

Analysis of a silicon piezoresistive pressure sensor

Complete 3D measurement solution

SUPPLEMENTARY INFORMATION

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 14: Invasive attacks

ypr y Ca 3/8 MnO 3 (y = 0.375) powders (bottom) at µ 0 H = 0.1 T, which are two prototype manganite

STEM electron tomography in the Scanning Electron Microscope

3D Imaging and Investigation of Failure and Deformation in Thermal Barrier Coatings Using Computed X-ray Tomography

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control

Transmission Electron Tomography 3D Reconstruction of Directed Self-Assembly Di-Block Copolymers

Calibration of a portable interferometer for fiber optic connector endface measurements

T-SCAN 3 3D DIGITIZING

Numerical Procedure for Modeling of Light Emitting Diode with Mesh- Like Electrode

Influence of Geometrical Configuration of Cantilever Structure on Sensitivity of MEMS Resonant Sensors

Product Specifications

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

Supporting Information. for. Pattern generation for direct-write three-dimensional nanoscale. structures via focused electron beam induced deposition

Transcription:

Supplemental Information Fuel Cell Preparation. The anode supported SOFC studied was Ni-YSZ/YSZ/LSM- YSZ,LSM (YSZ = 8 mol% Y 2 O 3 -stabilized ZrO 2 and LSM = La 0.8 Sr 0.2 MnO 3 ). The anode substrates, consisting of NiO/YSZ (70/30wt%) with 10% starch filler, were bisque fired at 1000 0 C. Thin (10-20 µm) layers of NiO/YSZ (50/50wt%) and YSZ were deposited on the supports using a colloidal deposition technique similar to that described previously. 27 The anode and electrolyte were co-fired at 1400 0 C for 6h. LSM-YSZ cathode layers were applied and fired at 1200 0 C for 4 h. A second layer of pure LSM slurry was then applied and fired at 1200 0 C for 4 h. The colloidal NiO/YSZ layer adjacent to the YSZ electrolyte, which was the electrochemically active portion of the anode, was the region studied in detail here. Fuel Cell Testing. Single cells were tested using a standard testing geometry, similar to that reported previously. 19 At the beginning of each test, the Ni-based anode was fully reduced in humidified H 2 at 800 0 C. The cells were tested with air at the cathode, while the fuel was humidified hydrogen. Image Collection. The present images were collected using a Zeiss 1540XB FIB-SEM. The configuration, illustrated schematically in Figure 1, allows simultaneous collection of a series of 2D cross-sectional SEM images as the specimen is sectioned by the FIB along the third axis. The fuel cell was first cut and polished, leaving a cross-sectional surface with the anode, electrolyte, and cathode exposed. The focused ion beam (FIB) was then used to mill a rectangular trench into this surface in the vicinity of the anode, as shown in Figure 1. The electron beam was used to image one of the trench side walls at an angle of 36 from normal to the side wall. As the FIB shaved away material from this surface, tilt-corrected SEM images were continuously acquired, with scan- and frame-grab rates synchronized with milling rate for

high quality imaging. In this manner, a series of 2D images was obtained. A few typical 2D images are shown in supplemental figure S2. A spacing v = 44nm between consecutive images was calculated from the fixed FIB milling rate and the milling time per image. Two independent milling rate calibrations were used. First, a calibration sample was milled using the same FIB scan rate and a fixed mill time, and the milled depth was measured by FIB imaging. The second method employed fiducial marks, milled on the top surface of the specimen prior to sectioning (Fig. 1A), to measure the milled depth. The two methods yielded results that agreed within 1% in measuring a milled depth of approximately 1 µm. Image Stacking. Accurate stacking of the images requires that the reconstruction account for any resolution differences in all directions and that the individual sections be aligned properly. Alignment of the images was accomplished by using the fiducial marks as points of reference. An FFT-based algorithm was subsequently implemented to verify the alignment. 28 A total of 82 images were used in the reconstruction to produce a total analyzed volume of 105.2 µm 3. The above process was done manually for the present data, taking a few weeks, much more than that needed for image acquisition and 3D calculations (a few hours each). Advances in automating this procedure are being made, such that future timescales for full reconstruction will be on the order of days. Due to the different resolutions in different directions 10 nm in the image plane and 50 nm between images in the 3D data sets, the desired approximately cube-shaped voxels were obtained by reducing the resolution to 41.7 nm in the images. This loss of resolution was not a serious problem for the present anodes, which were typical of state-ofthe-art SOFC anodes, where the feature sizes ranged from ~ 200 nm to 1 µm (see Figure 2). In one case, we adjusted the image resolution to check for potential errors. We calculated the total interfacial areas on 2D images with the original resolution (13.9 nm) and with the reduced

resolution (41.7 nm) that was normally used to obtain nearly cube-shaped voxels. The reduction in the interfacial areas in the 2D images due to resolution reduction was found to be 5% on the average, providing an estimate for the errors in the surface area associated with the resolution used. In the future, it should be possible to reduce the spacing between images in the FIB-SEM measurements, perhaps as low as 10 nm, thereby improving the resolution.

Supplemental Figures. Figure S1. Measured voltage and power density versus current density for the SOFC utilized in the present study. Figure S2. Four representative SEM image sections of the Ni-YSZ anode separated by 150 nm, illustrating the change in the microstructure with depth along the milling direction.

27 Zhan, Z. & Barnett, S.A. Solid oxide fuel cells operated by internal partial oxidation reforming of iso-octane. J. Power Sources, in press. 28 Xie, H., Hicks, N., Keller, G.R., Huang, H. & Kreinovich, V. An IDL/ENVI implementation of the FFT-based algorithm for automatic image registration. Computers and Geosciences 29(8), 1045-1055 (2003).