UNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated April 2018

Similar documents
UNIFIED FACILITIES GUIDE SPECIFICATIONS

ROLLING COUNTER SHUTTERS

LEE DAN COMMUNICATIONS, INC.

LEE DAN COMMUNICATIONS, INC.

Common grade: ASTM A36..min. 36,000 yield / min. 58,000 tensile. Size Weight (lbs.) Weight (lbs.)

LEE DAN COMMUNICATIONS, INC.

TILBURY STEEL SERVICE CENTRE

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

UFGS (August 2013) UNIFIED FACILITIES GUIDE SPECIFICATIONS

VAREC 5000/5010 SERIES FLAME ARRESTERS

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

Stainless Steel Sinks

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Assembly and Maintenance

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Index. Aluminum. Channel. Coil. Floor Plates. Angles. Flats. Beams. Expanded Metal. Hexagons. Angle Bar Beams Galvanized...

UNIFIED FACILITIES GUIDE SPECIFICATIONS

North US 290 US 183. MLK Blvd. FM 969. ASERO Steel Sales. Ben White TX 71 IH-35 US 183

Thermal management. Thermal management

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Addendum # 2. Bid # Scoreboards (Softball Baseball Soccer) Addition Specification on Softball and Baseball

SECTION WIRING AND CONTROL DEVICES

DUKE UNIVERSITY CONSTRUCTION STANDARDS

SECTION EGR ELEVATED GLASS RAILING SYSTEMS. A. Tempered Glass Wet Glazed in Elevated Railing Assemblies.

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

RE Series Rack from Eaton Product Presentation

SECTION A. Tempered Glass Free Standing Swing Gate Post Assemblies.

SECTION TAPER-LOC DRY GLAZE GLASS RAILING SYSTEMS. A. Monolithic Tempered Glass Dry Glazed Railing Assemblies.

2019 Data Center Solutions

EcoTec SP tables and base cabinets

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Standard Bellows Metering Pumps

Current Control Houses

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Rolling Shutters - 3 Part Specs

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

HP Modular Cooling System: water cooling technology for high-density server installations

Océ CS9060. User s Guide. Eco Solvent

RESTRICTED WORLD TRADE G/IT/SPEC/8/Rev.1 23 February 1998 ORGANIZATION PROPOSED ADDITIONS TO PRODUCT COVERAGE. Submission by Australia.

DETAIL SPECIFICATION SHEET

SECTION SWITCHGEAR

Emery County Senior Center Green River 06/07

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR TRAVEL TIME SYSTEM. UNIV:SRP 1 of 6 ITS:APPR:CLC:DBP:

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

9. SPARE PARTS -43- STEAM SYSTEM (OPTION ONLY) Steam Switch Water Solenoid

2010 Replacement Parts List For Swing Doors

MILITARY SPECIFICATION REVETMENT KIT, PREFABRICATED MODULAR TYPE; CORRUGATED STEEL PANELS

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments.

DIRECT DRIVE VANEAXIAL FIXED PITCH FANS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION THERMAL UTILITY METERING INTERFACE

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SECTION PANELBOARDS

resistance for high requirement

Specification. Radiamatic Detectors and Accessories

The 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.

Instrument Prep & Pack Tables... Ergonomic/Hydraulic

Plate. Channels - Standard Structural* Conforms to ASTM A36 Lengths Available: 20 Ft. and 40 Ft. Stock items are highlighted in blue.

Specification and Design Catalog. Waterside Economizer

DOCKING STATION SPECIFICATIONS

Governing Standards. All wiring and components shall meet the applicable requirements of the NEC.

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

IVR15-SPI 1.5 Solid State Illuminated Rail 2 Post Integral Power Supply

Dishmachine Division Please call for pricing or

Index. E Expanded Metal Raised Flattened Grating... 93

Nominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

Plumbing. New-Toilet In A Box. Please call for the Best Price (954) S TRAP TOILET IN A BOX X57734 $139.

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

Plumbing Brass Specification Guide

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Heat Exchanger Condenser Expanders

Linear Luminaire with LED Series 6012/5

SECTION [13200] FRAMED 2000 CLEANROOM WALL SYSTEM

Pressure Test Pumps. Test Pump. Electric Test Pump. Assembly and Maintenance Test Pumps

Liebert XDA Air Flow Enhancer. User Manual

Technical Data Sheet Excel 741

Pre-installation Manual

Compact Bellows Pumps

InForm Superstructures

ENCLOSURE HEAT DISSIPATION

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858)

Reducing Data Center Cooling Costs through Airflow Containment

TYPE 4/12 PREMIER SERIES

Webb Core Cleanroom Wall System

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

IRONRIDGE PRODUCT CATALOG

PRECISION. Mammography Illuminator. Model shown

[This page is intentionally blank]

SUBMERSIBLE PUMPS SEWAGE RANGE

Installation Site Survey Walchem Web-Based Controllers April 27, 2004

June 1, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA

Transcription:

USACE / NAVFAC / AFCEC / NASA UFGS-11 27 13 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-11475 (August 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated April 2018 SECTION TABLE OF CONTENTS DIVISION 11 - EQUIPMENT SECTION 11 27 13 RADIOGRAPHIC DARKROOM EQUIPMENT 04/06 PART 1 GENERAL 1.1 REFERENCES 1.2 RELATED REQUIREMENTS 1.3 SUBMITTALS PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Aluminum Alloy 2.1.2 Carbon Steel 2.1.3 Stainless Steel 2.2 ITEMS 2.2.1 Film-Loading Bin 2.2.2 Cassette Transfer Box Cabinet 2.2.3 Illuminator, Radiographic Film, Recess Mounted 2.2.3.1 Illuminator, 1 Panel Recessed 2.2.3.2 Illuminator, 2 Panel Recessed 2.2.3.3 Illuminator, 8 Panel Recessed 2.2.3.4 Illuminator, 4 Panel Recessed 2.2.3.5 Illuminator, 4 Panel Explosion Proof 2.2.4 Illuminator, 1 Panel Surface 2.2.5 Illuminator, 2 Panel Surface 2.2.6 Illuminator, 8 Panel With Desk 2.2.7 Processor, X-Ray Film, 90 Seconds 2.2.8 Developing Tank, X-Ray PART 3 EXECUTION 3.1 INSTALLATION 3.2 FIELD QUALITY CONTROL 3.2.1 Inspections 3.2.2 Adjustments -- End of Section Table of Contents -- SECTION 11 27 13 Page 1

SECTION 11 27 13 Page 2

USACE / NAVFAC / AFCEC / NASA UFGS-11 27 13 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-11475 (August 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated April 2018 SECTION 11 27 13 RADIOGRAPHIC DARKROOM EQUIPMENT 04/06 NOTE: This guide specification covers the requirements for radiographic darkroom equipment. Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s) or insert appropriate information. Remove information and requirements not required in respective project, whether or not brackets are present. Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR). NOTE: On the drawings, show equipment covered by this section and the relationship to adjacent work. NOTE: To avoid repetition, general requirements common to other medical and dental equipment sections are in Section 11 70 00 GENERAL REQUIREMENTS FOR MEDICAL AND DENTAL EQUIPMENT. PART 1 GENERAL 1.1 REFERENCES NOTE: This paragraph is used to list the publications cited in the text of the guide SECTION 11 27 13 Page 3

specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title. Use the Reference Wizard's Check Reference feature when you add a Reference Identifier (RID) outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates. References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process. The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM A480/A480M ASTM A568/A568M ASTM B221 ASTM B221M ASTM D2665 (2017) Standard Specification for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip (2017a) Standard Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric) (2014) Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings 1.2 RELATED REQUIREMENTS Conform to Section[s] 11 70 00 GENERAL REQUIREMENTS FOR MEDICAL AND DENTAL EQUIPMENT[,] [.]" [23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS][,][.]" [and] [26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS.] Provide final utility connections and utility service to equipment. 1.3 SUBMITTALS NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit SECTION 11 27 13 Page 4

the following list to reflect only the submittals required for the project. The Guide Specification technical editors have designated those items that require Government approval, due to their complexity or criticality, with a "G". Generally, other submittal items can be reviewed by the Contractor's Quality Control System. Only add a G to an item, if the submittal is sufficiently important or complex in context of the project. For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the "G" designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: "AE" for Architect-Engineer; "DO" for District Office (Engineering Division or other organization in the District Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project Office. Codes following the "G" typically are not used for Navy, Air Force, and NASA projects. Use the "S" classification only in SD-11 Closeout Submittals. The "S" following a submittal item indicates that the submittal is required for the Sustainability enotebook to fulfill federally mandated sustainable requirements in accordance with Section 01 33 29 SUSTAINABILITY REPORTING. Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects. Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are [for Contractor Quality Control approval.][for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability enotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-02 Shop Drawings NOTE: Delete items that are not used. Add any additional items requiring detail drawings. Film-Loading Bin Cassette Transfer Box Cabinet Processor, X-Ray Film, 90 seconds SECTION 11 27 13 Page 5

Developing Tank, X-Ray SD-03 Product Data Film-Loading Bin Cassette Transfer Box Cabinet Illuminator, 1 Panel Recessed Illuminator, 1 Panel Surface Illuminator, 2 Panel Recessed Illuminator, 2 Panel Surface Illuminator, 8 Panel With Desk Illuminator, 8 Panel Recessed Illuminator, 4 Panel Recessed Illuminator, 4 Panel Explosion Proof Processor, X-Ray Film, 90 seconds Developing Tank, X-Ray SD-10 Operation and Maintenance Data Film-Loading Bin, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Cassette Transfer Box Cabinet, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 1 Panel Recessed, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 1 Panel Surface, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 2 Panel Recessed, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 2 Panel Surface, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 8 Panel With Desk, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 8 Panel Recessed, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] Illuminator, 4 Panel Recessed, Data Package 1 plus wiring Diagrams and Control Diagrams; G[, [ ]] Illuminator, 4 Panel Explosion Proof, Data Package 1 plus wiring diagrams and control diagrams; G[, [ ]] SECTION 11 27 13 Page 6

Processor, X-Ray Film 90 seconds, Data Package 3; G[, [ ]] Chemical Automatic Mixer, Data Package 3; G[, [ ]] Developing Tank, X-Ray, Data Package 3; G[, [ ]] Submit in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA. PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Aluminum Alloy ASTM B221M ASTM B221, equivalent in ultimate tensile, yield, and shear strengths to Alloy 6063-T5 or 6063-T6. 2.1.2 Carbon Steel ASTM A568/A568M, cold-rolled sheets, commercial bright finish. Stretcher level sheets 1.5 mm thick 16 gage and lighter. 2.1.3 Stainless Steel ASTM A480/A480M, Class 301, 302, or 304. 2.2 ITEMS 2.2.1 Film-Loading Bin Cabinet suitable for storing and sorting open, unexposed boxes of medical radiographic film; approximately 525 mm wide, 450 mm deep and 875 mm high 21 inches wide, 18 inches deep and 34 1/2 inches high. Include: a. Base cabinet fabricated of carbon steel with finished sides, with solid-face, recessed base, suitable for application of resilient base material. b. Swing-out bin: flush mounted, with front panel marked "FILMS - DO NOT OPEN IN LIGHT." Counterbalance unit mount with continuous piano-type hinge along lower edge. c. Built-in spacers, dividing bin into five equal compartments each approximately 395 mm wide by 57 mm front to back by 500 mm deep 15 1/2 inches wide by 2 1/4 inches front to back by 20 inches deep. d. At least four removable inserts, suitable for adapting divided spaces to accept film boxes in sizes of 100 by 125 mm 4 by 5 inches, 125 by 175 mm 5 by 7 inches, 165 by 215 mm 6 1/2 by 8 1/2 inches, 200 by 250 mm 8 by 10 inches, 175 by 430 mm 7 by 17 inches, 240 by 240 mm 9 1/2 by 9 1/2 inches, 250 by 300 mm 10 by 12 inches, 275 by 350 mm 11 by 14 inches and 350 by 430 mm 14 by 17 inches, all with box tops flush with top of bin. e. Limit switch: 115 volts, 60 hertz (Hz), located in cabinet back, ready for connecting in series with darkroom white light so lights are automatically extinguished when bin is opened. SECTION 11 27 13 Page 7

2.2.2 Cassette Transfer Box Cabinet Four-door, automatic interlock, lead-lined, double compartment unit, suitable for through-the-wall transfer of radiographic film cassettes, approximately 550 mm wide by 475 mm deep by 550 mm high 22 inches wide by 19 inches deep by 22 inches high. Include: a. Automatic interlock doors, preventing both doors of a common compartment from being opened at same time. b. Label doors "EXPOSED" and "UNEXPOSED". c. Automatic signal device, activated when one or more standard, 125 by 175 mm 5 by 7 inch or larger cassettes are in compartments, consisting of: (1) Light system, mounted over doors of transfer cabinet, with white light on side of transfer cabinet opposite darkroom; lighted when compartment designated as "UNEXPOSED" is occupied and colored light on darkroom side of box; lighted when compartment designated as "EXPOSED" is occupied. (2) Colored light, safe for up to 2 minutes for unprotected high-speed medical radiographic films when they are exposed at distance of 600 mm 24 inches from light source. d. Voice passage, light, and radiation baffle. e. Installation accessories, including rough-in frame, brackets, and trim. f. Lead lining, 2 mm 1/16 inch minimum thickness, providing protection of complete assembly, equal to or greater than protection of wall within which it is located. g. Power source of [120] [208] [220] [ ] volts, [50] [60] Hz, single-phase, operating from primary electric power. 2.2.3 Illuminator, Radiographic Film, Recess Mounted Explosion-proof fluorescent fixture, with each viewing panel independently switched. Include: a. Electrical characteristics: [120] [220] [ ] volts, [50] [60] Hz, single-phase. b. Illumination: Maximum panel brightness not less than 1540 candelas per square meter 450 foot lamberts located within a 150 mm 6 inch square at center of viewing panel. Minimum panel brightness not less than 65 percent of maximum panel brightness. Do not include areas of viewing panel within 38 mm 1 1/2 inches of edges in brightness measurements. c. Trim for recessed installation. d. Film-holding device: Continuous-ball or strip-spring type extending across top of each viewing panel. All parts corrosion-resistant steel or plastic. SECTION 11 27 13 Page 8

2.2.3.1 Illuminator, 1 Panel Recessed Single unit approximately 500 mm high by 375 mm long by 125 mm deep 20 inches high by 15 inches long by 5 inches deep. 2.2.3.2 Illuminator, 2 Panel Recessed Double unit approximately 500 mm high by 750 mm long by 125 mm deep 20 inches high by 30 inches long by 5 inches deep. 2.2.3.3 Illuminator, 8 Panel Recessed Eight-panel, (four in tandem, double deck), four over four, approximately 1000 mm high by 1500 mm wide by 125 mm deep 40 inches high by 60 inches wide by 5 inches deep. 2.2.3.4 Illuminator, 4 Panel Recessed Four-panel, approximately 700 mm high by 1750 mm wide by 150 mm deep 28 inches high by 69 inches wide by 6 inches deep. 2.2.3.5 Illuminator, 4 Panel Explosion Proof Four-unit, approximately 500 mm high by 1500 mm wide by 125 mm deep 20 inches high by 60 inches wide by 5 inches deep. 2.2.4 Illuminator, 1 Panel Surface Explosion-proof, single-panel, fluorescent fixture, each viewing panel independently switched. Approximate dimensions: 500 mm high by 430 mm wide by 125 mm deep 20 inches high by 17 inches wide by 5 inches deep. Include: a. Electrical characteristics: [120] [220] [ ] volts, [50] [60] Hz, single-phase. b. Illumination: Maximum panel brightness not less than 1540 cd/sq m 450 foot lamberts located within 150 mm 6 inch square at center of viewing panel. Minimum panel brightness not less than 65 percent of maximum. Do not include areas of viewing panel within 38 mm 1 1/2 inches of edges in brightness measurements. c. Enameled steel frame. d. Line cord, 3-wire, 2125 mm 7 feet long with hospital-grade plug. e. Film-holding device: Continuous-ball or strip-spring type extending across top of each viewing panel. Corrosion-resistant steel. f. Mounting hardware. 2.2.5 Illuminator, 2 Panel Surface Double unit, continuous-surface viewing with dual switches, heli-grip film support. Approximate dimensions: 450 mm high by 120 mm wide by 775 mm long 17 7/8 inches high by 4 3/4 inches wide by 31 inches long. Include: a. Electrical characteristics: [110] [220] [ ] volts, [50] [60] Hz, single-phase. SECTION 11 27 13 Page 9

b. Illumination: Maximum brightness not less than 1540cd/sq m 450 foot lamberts located within 150 mm 6 inch square at center of viewing panel. Minimum panel brightness not less than 65 percent of maximum. Do not include areas of viewing panel within 38 mm 1 1/2 inches of edges in brightness measurements. c. Stainless steel frame. d. Line cord, 3-wire, 2125 mm 7 feet long with hospital grade plug. e. Film holding device: Continuous-ball or strip-spring extending across top of each viewing panel. Corrosion-resistant steel. f. Mounting hardware. 2.2.6 Illuminator, 8 Panel With Desk Four over four format mounted in high density particleboard frame with walnut grain melamine, high-pressure laminated end panel. Mount lower bank of illuminators at a 30- or 45-degree angle. Illuminator unit approximately 1475 mm long by 525 mm deep by 1350 mm high 59 inches long by 21 inches deep by 54 inches high. Desk, of same construction as illuminator frame, shall be approximately 1500 mm long by 450 mm deep by 200 mm high 60 inches long by 18 inches deep by 8 inches high. Include: a. Electrical characteristics: [115] [230] [ ] volts, [50] [60] Hz, single-phase. b. Two remote control switches for individual light panel control. c. High intensity spot-viewer device, manual type. 2.2.7 Processor, X-Ray Film, 90 Seconds Unit shall automatically develop, fix, wash, and dry 350 mixed-sized medical radiographic films per hour at 90 seconds per film. Provide cabinetized unit, roller-transport type, for locating in lighted room and fed from darkroom through opening in wall. Include the following: a. Cabinet: chemical-resistant finish with removable panels to facilitate servicing. b. Controls: automatic, accessible from feed side of unit; include power switch and replenisher status indicators. c. Standby mode: to reduce power and water consumption when films are not being processed. NOTE: Heat and corrosive fumes are normally exhausted from darkroom face of this unit. The exhaust hose connects collar on unit to duct stub in the darkroom. Other specification sections must provide duct stub and exhaust fan, fabricated of corrosion-resistant materials. d. Exhaust hose: flexible, acid fume-resistant tubing, [3000 mm] [10 feet] SECTION 11 27 13 Page 10

[ ] long. NOTE: Select size and type. Location of replenisher tanks should be enclosed by raised curb, and enclosed area should include an acid-resistant drain to facilitate emptying tanks without lifting them. [e. Replenisher tanks: two, 53 liter 14 gallon capacity, suitable for locating inside processor cabinet.] [e. Item Chemical Automatic Mixer to automatically mix replenisher solutions: on rollers with flexible hose connector. Electrical characteristic: 120-volts, 60 Hz, single phase.] NOTE: When chemical tanks are remotely located, chemical supply lines (each approximately 25 mm one inch in diameter) should be concealed in construction. f. Chemical supply tubing, plastic: resistant to harm from chemicals, to run from chemical tank spout to processor fitting. NOTE: The wall where this unit is to be located may be provided with an opening larger than necessary, and millwork can provide a lightproofing rough-in frame fabricated from 20 mm 3/4 inch plywood with compressible foam lightlock strip. g. Lightproof stripping: compressible foam for application to either perimeter of rough opening or edge of unit's face. NOTE: Minimum drainpipe diameter shall be 88 mm 3 1/2 inches. It shall include a strainer and incorporate a bucket or funnel design that deters splashing during discharge. Both drain and waste lines from this drain must be both acid- and corrosion-resistant. h. Pipe and fittings: ASTM D2665, polyvinyl chloride (PVC). Assemble as L-shaped line connected to face of processor at waste opening, allowing waste flushed from processor to discharge directly over floor drain; provide 25 mm one inch minimum air gap between discharge end of pipe and drain. NOTE: Provide breaker in vicinity of processor to facilitate safe removal and servicing. i. Service characteristics: SECTION 11 27 13 Page 11

Electrical: [120/208] [120/240] [ ] volts; [50] [60] Hz; [3] [4] [5]-wire; [single-][three-] phase. 2.2.8 Developing Tank, X-Ray Refrigerated type tank assembly, refrigerated type, splashproof, single compartment unit, for manually developing, fixing, and washing medical radiographic films; approximate overall dimensions of 950 mm high by 500 mm wide by 525 mm deep 38 inches high by 20 inches wide by 21 inches deep. Include: a. Cabinet: Type 316 stainless steel, heliarc welded and chemically passivated, with insulated tank, assembly reinforced, and corrosion-resistant legs with adjustable leveling feet. b. Refrigeration unit: Integrally located, mounted on isolators, including thermostatic control, watercooled condenser, and cooled water storage tank; capable of delivering 95 liters per hour (LPH) [20] degree Centigrade (C) 25 gallons per hour (GPH) [68] [ ] degree Fahrenheit (F) water when incoming water is [29] [ ] degrees C [85] [ ] degrees F. c. Waste piping: Preinstalled, acid resistant, including overflow drain, drain valve, couplings, and fittings. d. Inserts: Two solution tanks, each with 19 liter 5 gallon capacity. NOTE: Select applicable paragraph(s) from following: [e. Insert tank covers: One for each insert, Type 316 stainless steel.] [e. Tank covers: For covering full tank opening and all inserts, Type 316 stainless steel.] f. Valve: Thermostatic, for wall surface mounting, 3.8 liters per minute (LPM) through 19 lpm at 412 kilopascals one gallon per minute (GPM) through 5 gpm at 45 pounds per square inch (psi), with integral dial thermometer, diverter valve, and spray hose unit for cleaning tank and components. PART 3 EXECUTION 3.1 INSTALLATION Install at locations indicated. Conform to installation requirements of Section 11 70 00 GENERAL REQUIREMENTS FOR MEDICAL AND DENTAL EQUIPMENT. 3.2 FIELD QUALITY CONTROL 3.2.1 Inspections Examine each item for visual defects and conformance to specifications. 3.2.2 Adjustments Adjust each item to ensure that equipment is operational and conforms to SECTION 11 27 13 Page 12

specification requirements. -- End of Section -- SECTION 11 27 13 Page 13