Pre-installation guide for analytical systems User manual HPLC

Similar documents
TA Instruments Installation Requirements for Microcalorimeter Systems

TA Instruments Installation Requirements for Microcalorimeter Systems

Nano DSC and MCDSC. Site Preparation Guide

SepacoreControl Software data sheet

OpenLAB. CDS EZChrom Edition KNAUER Instrument Control SOFTWARE

Valve Unifier VU 4.1 Instructions HPLC. Document No. V6855

TAM Air Isothermal Calorimeter. Site Preparation Guide

TCC-100 Thermostatted Column Compartment Quick Installation Guide August 2003 Rev. 2 Page Dionex

Dionex SRD-10 Suppressor Regenerant Detector Installation Instructions

Installing TAM Air Assistant Software TM

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

Release Note for Agilent LC and CE Drivers Revision A.02.19

Release Note for Agilent LC and CE drivers Revision A.02.14

Column Thermostat for HPLC and GPC STH 585

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

Breeze 2 Installation and Configuration Guide

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

USB 3.0 Dual Head Display Adapter

Agilent OpenLAB Chromatography Data System (CDS)

TA Instruments Installation Requirements for Microcalorimeter Systems

Compaq Evo D310 Micro Desktop

Specifications LAN *3

Customer Responsibilities

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

Release Note for Agilent LC and CE Drivers Revision A SR1

Sepacore X10 / X50 system Technical data sheet

Operating Instructions

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

RТTH DUAL ROOM SWITCH

WIRELESS OFFICE DESKTOP SL DESIGN

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Agilent 2100 Bioanalyzer System & Applications Site Preparation Checklist

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

CD-70 USB Display User Manual

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

USER GUIDE FOR NETmc MARINE 73fifty Harvester PC

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

Operating Manual MPI-300 NCS-M Parameter Tool

Communication Gateway COM 610. Product Guide

Customer Responsibilities

THAYER SCALE. AUDiTORTM CONTINUOUS WEIGHING & FEEDING OF BULK MATERIALS. NTEP CERTIFIED Conveyor Belt Scale Monitor and Software package.

HITACHI LACHROM ELITE

PLEXUS MUSIC MANAGEMENT SYSTEM

DM 161 S-DIAS Digital Mixed Module

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Release Note for Agilent LC and CE Drivers Revision A.02.17

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

Release Note for Agilent LC and CE Drivers Revision A.02.16

Electronic Temperature Controller. Instruction Manual Version

2100 POS System User Guide

Customer Responsibilities

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

RADCOM s Platform Specifications. Valid from Version 7.10

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

HMIPPH7A0701 Panel PC Performance - Hard Disk - 15'' - AC - 0 slot - fan

modunet292: novanet-ethernet interface

Version 1.0 March 2014 OLC 10.1

KS 108 easy Compact automation unit for industrial control and process technology

3+1 U CPCI Serial System

CPCI System Subrack 1 U

2190 POS System User Guide

Sauter Systems

Quick Start Guide and Health and Safety Information

Automation Prüftechnik Formenbau Kunststofftechnik RFID Systeme Lasertechnik. User Manual. Daimler LF-SPG. Version Date Editor Changes / Comments

RCO-3000 Advanced Fanless System with 5 th Gen Intel Broadwell Core i5/i3 or Celeron Processor, 2x LAN

Zenith DS9000 Dispensing System

Customer Responsibilities

AO 081 S-DIAS Analog Output Module

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11

Installation and Operating instructions for. Control Cabinet PC C6240 from Version: 2.0 Date:

FX-1 CD-RW Rev. 148

Installation- and Operating instructions for. Build-in Industrial PCs C3620, C3640 from Version: 3.0 Date:

TWINHEAD. Plug-In PC - PLUGTH series for Panasonic Professional Displays. Operating Instructions. PN1H (Model number PLUGTH series) English

KL 181 S-DIAS +24 V Potential Distributor Module

Avanti HP Series Centrifuges Preinstallation

AZURA instruments & components for (U)HPLC, Prep LC, FPLC and osmometry

Release Note for Agilent LC and CE Drivers Revision A.02.15

HMIBMUSI29D2801 Modular Box PC HMIBM Universal SSD DC Windows 10 2 slots

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer.

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

RO 051 S-DIAS Relay Output Module

TELTONIKA ModemUSB/G10 User Manual v0.1

3/4 U CPCI Serial Case System

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual

User Manual HIGH PERFORMANCE USB GRAPHIC ADAPTER. DA Rev. 2-2

KS 108 easy Compact automation unit for industrial control and process technology

icore Kiosk system Installation Guide

Alliance e2695 Separations Module Firmware Version 3.04

HMIBMUCI29D2W01 Modular Box PC HMIBM Universal CFast DC WES 2 slots

VI 021 S-DIAS VARAN Control Module

Installation and Operating instructions for Industrial PC series C61xx from Version: 3.0 Date:

SegoSerial Industrial Grade Converter Isolated Dual RS232 - USB. Installation and operation. English Rev. 1.2 Status June I9

Agilent U2722A USB Modular Source Measure Unit. Data Sheet

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual

Transcription:

Pre-installation guide for analytical systems User manual HPLC

For your own safety, read the manual and always observe the warnings and safety information on the device and in the manual! 1 Manuel en français: Si jamais vous préfériez un manuel en français pour ce produit, veuillez vous contacter le support technique (Technical Support) par email ou par fax avec le no. de série. Merci beaucoup. Technical Support: Phone: +49 30 809727-111 (9-17h, Central European Time) Fax: +49 30 8015010 E-Mail: support@knauer.net Languages: German, English Publisher: KNAUER Wissenschaftliche Geräte GmbH Hegauer Weg 38 D-14163 Berlin Phone: +49 30 809727-0 Fax: +49 30 8015010 Internet: www.knauer.net E-Mail: info@knauer.net Version information: Article number: V6802 Version number: 3.1 Last update: 2017/06/19 Original edition

2 The information in this document is subject to change without prior notice. For latest version of the manual, check our website: http://www.knauer.net/knowledge.html Copyright: This document contains confidential information and may not be reproduced without written content of KNAUER Wissenschaftliche Geräte GmbH. KNAUER Wissenschaftliche Geräte GmbH 2017 All rights reserved. AZURA is a registered trademark of KNAUER Wissenschaftliche Geräte GmbH.

Table of contents Table of contents 3 Overview..................................................... 4 Storing unopened shipping boxes............................... 4 Installation site requirements.................................... 4 Ambient conditions......................................... 4 Space requirements of the HPLC system....................... 4 Analytical AZURA HPLC systems................................ 6 Individual devices........................................... 6 System layout examples..................................... 6 Power supply.................................................. 7 Universal AC/DC switching power adapter.................. 7 Power cable............................................. 7 Power connection........................................ 7 Minimum computer requirements............................... 8 KNAUER ClarityChrom /KNAUER ClarityChrom Prep 7.2.0..... 8 OpenLAB CDS EZChrom Edition............................ 8 KNAUER PurityChrom 5.................................... 9 Thermo ScientificTM DionexTM ChromeleonTM 7.2 CDS....... 10 KNAUER Mobile Control 4.0................................ 10 Uninstalling software, KNAUER drivers and extensions............ 10 Settings for sleep function.................................. 10 Technical data................................................ 11 Checklist..................................................... 12 Index........................................................ 13

4 Overview Overview This manual describes how to prepare for installing an analytical AZURA System. It contains information on the following: intermediate storage of shipping boxes system set-up installation site requirements dimensions of analytical systems power supply characteristic data of individual modules computer requirements for software Storing unopened shipping boxes The shipping boxes are supplied on a pallet sized 80 x 120 cm. In your planning, include the following information for immediate storage of this pallet. sufficient space storage temperatures must be in the temperature range 4 40 C, 39 104 F Installation site requirements The HPLC system will be set up, installed and commissioned by KNAUER or a company authorized and contracted by KNAUER. KNAUER recommends inviting future users to be present while setting up and commissioning the module so that they can become familiar with the analyzer and how to handle it. Ambient conditions humidity: below 90 % (non-condensing) temperature range: 4 40 C; 39 104 F Space requirements of the HPLC system Only if the requirements for ambient conditions of the operating environment are met, can the intended use be ensured. Details on the operating conditions can be found in the Technical Data section.

Installation site requirements 5 Device defect The device overheats at exposure to sunlight and insufficient air circulation. Device failures are very likely. Set up the device in such a way that it is protected against exposure to direct sunlight. Keep at least 15 cm clear at the rear and 5 10 cm at each side for air circulation. Space requirements At least 5 cm if another device is set up on one side At least 10 cm if further devices are set up on both sides At least 15 cm on the rear panel for the fan. Leave the power plug on the rear of the device accessible to be able to disconnect the device from the mains. General requirements Position the device on a level and even surface. Protect the device against direct exposure to sunlight. Set up the device at a location not exposed to air drafts (A/C systems). Do not set up the device near other machines that cause floor vibrations. The leak sensor may malfunction if the device is placed on an inclined surface. Use a level to check that the device is in horizontal position. Earth quake regions If the device is set up in a region where earth quakes are common, secure the device at the two fixing points 1. The fixing points are situated on both sides of the device.

6 Analytical AZURA HPLC systems 1 Fig. 1 Fixing points on the device Analytical AZURA HPLC systems Individual devices Systems for analytical applications typically consist of the following devices: solvent tray gradient pump (quaternary, binary, or isocratic) with degasser, mixing chamber, and pressure sensor autosampler or manual valve analytical column column thermostat detector System layout examples Examples for set-up of an AZURA HPLC system: 1 detector (example) 2 pump (example) 3 solvent tray 4 column thermostat 5 autosampler 1 2 3 4 5 Fig. 2 AZURA system, horizontal setup

Power supply 7 1 solvent tray 2 pump (example) 3 detector (example) 4 column thermostat 5 autosampler 1 2 3 4 5 Power supply Universal AC/DC switching power adapter The modules are equipped with an universal AC/DC switched-mode power adapter rated for 100 240 V AC. Power cable Power cables are part of the delivery and come in numbers matching the destination. The cables are available for the following destinations: EU, USA, Switzerland, UK Power connection Fig. 3 AZURA system, vertical setup Prerequisites for power connection: The electrical power supply at the installation site must be connected directly to the nearest main power line. The power must be free from ripple, residual current, voltage peaks and electromagnetic interference. The connectors for the mains voltage are grounded accordingly. The modules receive sufficient power and reserve capacity. The number of sockets corresponds to the number of devices in the system. Multi-outlet power strip with ON/OFF switch for individual system modules and additionally required modules.

8 Minimum computer requirements Electronic defect Damage to the electronics if the device is turned on while connecting or interrupting the power connection. Switch off the device beforehand. Minimum computer requirements KNAUER ClarityChrom /KNAUER ClarityChrom Prep 7.2.0 Operating system CPU Memory (RAM) Graphics/resolution Drive Free disc space 1 Connections 2 Windows 10, 32/64 bit Windows 8, 32/64 bit Windows 7, 32/64 bit Windows Vista (SP2), 32/64 bit Windows XP (SP3) Pentium 2 GHz Windows XP: 512 MB + 256 MB for each addtl. system or PDA detector up to 10 Hz data rate Windows 10 / 8 / 7 / Vista: 2 GB + 512 MB for each addtl. system or PDA detector up to 10 Hz data rate For all: 4 GB for PLATINblue PDA-1 and AZURA DAD 6.1L / 2.1L Separate graphics card recommended if more than 1 system is to be controlled DVD ROM (12x) 20 GB available, 80 GB for PLATINblue PDA-1 and AZURA DAD 6.1L / 2.1L USB for the licence dongle COM or USB and/or LAN for device control (depends on device type) 1. At high data transfer rates of the PDA detector, files with up to 100 MB file size may be created. 2. For every device that you want to connect via serial port, a separate COM port is required. You may use a USB-to-COM adapter to increase the number of ports. OpenLAB CDS EZChrom Edition For the OpenLAB Distributed Systems license, you need a Shared Services Server. For Distributed Systems licenses, the Shared Services server must be installed on a separate computer with Windows Server operating system.

Minimum computer requirements 9 Prerequisite Microsoft.NET Framework 3.5 with SP1 and Windows Installer 4.5 (for SQL Installation with Shared Services Server) must be installed. Operating system Windows 8.1, 32/64 bit (EZChrom Edition Workstation, EZChrom Edition Client) Windows Server 2008 (R2, SP1) (Shared Services Server, EZChrom Edition Client) Windows 7 (SP1), 32/64 bit (EZChrom Edition Workstation, EZChrom Edition Client) CPU 3 GHz Dual-Core Memory (RAM) 4 GB (32 bit) 6 GB (64 bit) Graphics/resolution separate graphic card for > 1 system Drive DVD ROM (12x) Free disc space 1 160 GB Connections 2 100/1000 Mbit LAN Adapter LAN, COM or USB for device control (depends on device type) KNAUER PurityChrom 5 Operating system CPU Memory (RAM) Windows 10, 32/64 bit Windows 8, 32/64 bit Windows 7, 32/64 bit Windows Vista (SP2), 32/64 bit Windows XP (SP3) 2GHz 512 MB (Windows XP) 1.5 GB (Windows 8/7/Vista: 32 bit) + 128 MB for a PDA-Detector + 128 MB for every additional system 2 GB (Windows 8/7/Vista: 64 bit) + 4 GB for DAD 6.1L Graphics/resolution 1024 768 Drive DVD ROM (12x) Free disc space 1 20 GB Connections 2 USB for the licence dongle LAN, COM or USB for device control (depends on device type)

10 Uninstalling software, KNAUER drivers and extensions Thermo Scientific TM Dionex TM Chromeleon TM 7.2 CDS Operating system CPU Memory (RAM) Graphics/resolution drive Free disc space 1 Connections 2 KNAUER Mobile Control 4.0 Uninstalling software, KNAUER drivers and extensions To uninstall chromatography software and device drivers, use the Windows Control Panel (CONTROL PANEL > UNINSTALL A PROGRAM). Settings for sleep function Windows 8.1, 64 bit (Professional Edition) Windows 7 (SP1), 64 bit (Professional/Ultimate Edition) Using of 32 bit versions is not recommended. Windows Vista (SP2), 32 bit (Business/Ultimate Edition), using of Windows Vista is not recommended. 3 GHz Intel Core 2 Duo 3GB 1024 768, 32 bit colours DVD ROM (12x) 60 GB USB for the licence dongle LAn for device control Operating system Only for Windows 10: CPU 1.5 GHz Dual-Core Memory (RAM) 1 GB without data acquisition, 2 GB with data acquisition Graphics/resolution 1024 768 Drive - Free disc space 1 200 MB Connections 2 LAN, Wifi for download of installation data and device control When you are working with the chromatography software, disable the sleep function. Going to CHANGE ADVANCED POWER SETTINGS and DEVICE MANAGER, change the following settings to NEVER: Turn off the screen all hardware settings as hard drive, USB, netword adapter

Technical data 11 Hibernate mode In case hibernate mode is active during data collection, the run is interrupted and no more data is collected. Deactivate the option ALLOW THE COMPUTER TO TURN OFF THIS DEVICE TO SAVE POWER in the power management of the network adapter. The power management is customized by the network-adapter producer and can not always be changed. Set the WINDOWS UPDATES settings to manual. In case you allow automatic installation for WINDOWS UPDATES, the computer boots automatically. Booting interrupts data collection. Technical data For technical data about external devices, please refer to the website of the producer. Device Weight in kg Dimensions (W H D) in mm Solvent tray 3.4 361 85 523 - E 2.1L P 6.1L HPG 14.1 361 208.2 523 100 P 6.1L LPG 12.7 361 208.2 523 100 P6.1L 11.5 361 208.2 523 100 isocratic AS 6.1L 30 377 300 510 200 AS 6.1L cool/ 32 377 300 575 200 heat version CT 2.1 8.4 150 470 310 100 RID 2.1L 10.8 361 158 523 65 UVD 2.1L 5.9 361 158 523 75 DAD 6.1L 13.8 361 158 523 75 DAD 2.1L 12.2 361 158 523 75 MWD 2.1L 12.2 361 158 523 75 ASM 2.1L about 14 (depending on configuration) 361 158 523 100 V 2.1S (without valve) 1.2 121 138 190 60 Power consumption in W

12 Checklist Checklist Transportation and storage There must be enough space available for storing the shipping pallet. HPLC System set-up A lab table with adequate carrying capacity and dimensions is available. The power supply and cable are available. The power supply and cable comply with the requirements. Ambient conditions at installation site The installation site complies with the requirements with respect to equipment, temperature, humidity, vibration and high frequency emissions. Computer and Operating System The computer complies with the requirements or is delivered by KNAUER.

Index A AC/DC switching power adapter 7 air humidity 4 ambient conditions 4 C checklist 12 computer requirements 8 D dimensions 11 drivers 10 E electromagnetic interference 7 H hibernate mode 11 HPLC systems 6 I individual devices 6 installation site 5 L line voltage 7 N network adapter 11 O operating environment 4 overview 4 P power disconnect 5 plug 5 power cable 7 Power connection 7 power consumption 11 power strip 7 R residual current 7 S shipping box 4 sleep 10 Index 13 software 10 Space requirements 4 space requirements 5 system layout 6 system set-up 4 T Technical Data 11 temperature range, storage temperature 4 U uninstalling 10 V voltage peaks 7 voltage supply 7 W weight 11 Windows Updates 11 AZURA Pre-Installation Guide, V6802

KNAUER manuals online: www.knauer.net/knowledge KNAUER 2017 KNAUER Wissenschaftliche Geräte GmbH Hegauer Weg 38 14163 Berlin Phone: +49 30 809727-0 Fax: +49 30 8015010 E-Mail: info@knauer.net Internet: www.knauer.net