Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth

Similar documents
Wavelength (nm) Specifications Summary. Active pixels 512 x 512. Pixel size (W x H) 24 µm x 24 µm

Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth (typical) 100,000 e -

Specifications Summary. Active pixels 2048 x Active area pixel well depth 100,000 e - Maximum readout rate. Read noise 2.9 e - Maximum cooling

Specifications Summary 3. Active pixels 2048 x Pixel size (W x H) 13.5 µm x 13.5 µm. Active area pixel well depth. Maximum readout rate

Neo scmos. Specifications Summary. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 25,000 e - Pixel readout rate (MHz) 560, 400, 200

Neo scmos. Specifications Summary. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 30,000 e - Pixel readout rate (MHz) 560, 200

800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

25.6 mm wide / 1600 pixel, 3 MHz Spectroscopy EMCCD. Specifications Summary 1. Output node well depth: Conventional mode Electron Multiplying mode

idus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88

Newton EMCCD. Specifications Summary 1. Output node well depth (typical) High Sensitivity mode Electron Multiplying mode

scmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary

andor.com Scientific CMOS - Fast, sensitive, compact and light Features and Benefits Specifications Summary Ultra Sensitive Imaging Low Light Imaging

Neo scmos. Specifications Summary 2. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 30,000 e - Pixel readout rate (MHz) 560, 200

Specifications Summary 2

600 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

Specifications Summary 2

1 MHz (2.4 e - ) 20 MHz (6.5 e - ) YEAR VACUUM WARRANTY. Pushing Interline Further. Specifications Summary. Active pixels (W x H) 1392 x 1040

ixon Specifications Summary Active pixels 128 x 128 Active area pixel well depth 250,000 e - Gain register pixel well depth 800,000 e -

5.5 Megapixel, -40ºC, 1 e- Noise Rolling and Global Shutter Scientific CMOS YEAR VACUUM WARRANTY. Specifications Summary 2. Pixel size (W x H) 6.

26.6 x 3.3 mm / 1024 x 127 pixel Spectroscopy CCD. Specifications Summary 2. Active pixels 1024 x 127. Register well depth (typical) 1,000,000 e -

16, x 1 Binning 14,000 12,000. Frame Rate (Frames/s) 10,000 4 x 4 Binning 8, x 2 Binning 6,000 4,000 2,000. Cropped Mode Array Size

27 mm wide, 3 MHz Spectroscopy CCD. Spectroscopy at Pace. Specifications Summary 1. Register well depth:

26.6 x 3.3 mm / 1024 x 127 pixel Spectroscopy CCD. Specifications Summary 2. Active pixels 1024 x 127. Register well depth (typical) 1,000,000 e -

Coherent kev Supercontinuum for Broad Element-Specificity. Courtesy of Dr. Daniil Kartashov. Specifications Summary 2. Register well depth

Specifications Summary 1. Array Size (pixels) Pixel Well Depth (typical) 94,000 e - Dark Current 2. Read Noise 3

Specifications Summary 3. Active pixels 2048 x Pixel size (W x H) 13.5 x 13.5 µm. Active area pixel well depth (typical) 100,000 e -

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Dark Current 2. Pixel Well Depth (typical) e e -

27 mm wide, 3 MHz Spectroscopy CCD. Spectroscopy at Pace. Specifications Summary 1. Register well depth:

ikon-xl 230 VERY LARGE AREA ASTRONOMY CCD P P P CCD NEW

. Ideal for fast, shutterless imaging

ikon-xl 231 VERY LARGE AREA ASTRONOMY CCD P P P P CCD NEW

DV887 (back illuminated)

SYNCERITY TM 1024 x 256

IMAGING GROUP. 512 x 512 imaging array; 24 mm x 24 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

IMAGING GROUP x 1300 imaging array; 20mm x 20mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

Applications: Astronomy, Photometry, EL/PL Imaging, Luminescence & Fluorescence Imaging, and Bose-Einstein Condensate (BEC) Page 1 of 7 IMAGING GROUP

IMAGING GROUP x 2048 imaging array; 13.5mm x 13.5mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

PIXIS: 512 IMAGING GROUP

ProEM -HS:1024BX3 FEATURES BENEFITS

Specifications. Wavelength range (nm) Focal length (mm) 195. Aperture F/7. Spectral resolution (λ/ λ) 1 (corresponding to 3 pixels FWHM)

20 MHz/16-bit readout 61 fps rate at full-frame resolution. Use ROI/binning for hundreds of frames per second.

195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195.

PyLoN: Applications: Astronomy, Chemiluminescence, Bioluminescence, Phosphor Imaging, Ultra-low light Imaging and Spectroscopy.

ProEM -HS:1KBX3-10µm

ProEM -HS:1024BX3 FEATURES BENEFITS

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels

Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Easy integration into complex experimental setup

Video frame rates and higher to efficiently synchronize with high repetition rate lasers

PI-MTE3. Datasheet LARGE-FORMAT, IN-VACUUM CAMERAS. Direct detection of soft x-rays. Up to 4k x 4k sensor formats. Reads out as fast as 3 full fps

Back-illuminated scientific CMOS cameras. Datasheet

SOPHIA 2048B. Datasheet ULTRA-LOW-LIGHT, LOW-NOISE UV / VIS CAMERAS LARGE-FORMAT CCD CAMERAS

PI-MAX 4: 1024 EMB. Applications:

FEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy

pco.1600 cooled digital 14 bit CCD camera system

PI-MAX 4: 1024 x 256 SPECTROSCOPY GROUP

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

TuCam. Features and Benefits. Andor TuCam - High Performance, Two Camera Imaging Adapter. Specifications Summary. Applications Guide

pco.1600 cooled digital 14 bit CCD camera system

PI-MAX 4: 1024 x 256

High Performance, High Resolution Detector Solutions. Dr Colin Coates, Product Manager 2015

NIRvana: 640. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

PI-MAX 4: 1024i-RF. Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

Lt Megapixel High-Speed CMOS Camera with SuperSpeed USB 3.0

Quad-RO: 4320 X-RAY GROUP

SOPHIA -XO 2048B SOPHIA -XO 4096B

Revolutionary High-Speed Cameras for Spectroscopy

4.2 Megapixel Scientific CMOS Camera

TuCam. Andor TuCam - High Performance, Two Camera Imaging Adapter. Features and Benefits. Specifications Summary.

Control & Interface Electronics. CCD Sensor

istar 320T Series Features and Benefits Industry leading platform for nanosecond-scale, high-speed Spectroscopy Specifications Summary

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

High Resolution BSI Scientific CMOS

Specifications Summary. Aperture size. Transmission > 96% Application Guide. Real time multi color imaging. Co-localization

Back Illuminated Scientific CMOS

Zyla. Speed and Sensitivity for Physical Science Imaging and Spectroscopy ZYLA 4.2 PLUS ZYLA 5.5

FEATURES. APPLICATIONS Machine Vision Embedded Instrumentation Motion Control Traffic Monitoring Security

Specifications Summary

TRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013

The Phantom v211 provides a widescreen CMOS sensor and greater than 2 Gigapixels/second throughput

The Phantom v3411 provides a widescreen CMOS sensor and greater than 4 Gigapixels/second throughput

Phantom v7.3. Phantom v7.3. Datasheet. Mechanical Drawing. Sensor Spectral Response 1 / 10

Overview and History Research Focus OEM / Instrumentation Capability Lean Manufacturing principles andor Pioneering EMCCD Technology

WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent

The Imaging Source USB 3.0 Series Cameras DMK 23UV024 / DFK 23UV024

SBIG Research Series STL-1001E, STL-1302E, STL-4020M, STL-6303E and STL-11000M Large Format CCD Cameras

sensicam qe cooled digital 12bit CCD camera system

High resolution Low noise High dynamic range Unparalleled sensitivity. Vision At Its Best

CMOS USORIA. Features

The CCD-S3600-D(-UV) is a

2.8 Megapixel GigE camera with Sony ICX674 CCD sensor

pco.edge electrons 2048 x 1536 pixel 50 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range

Low Light Imaging Cameras. low light imaging. Discover New Ways of Seeing.

NOW MAC COMPATIBLE INFINITY D I G I T A L M I C R O S C O P Y C A M E R A S

Product Information Version 1.1. ZEISS Axiocam 503 mono Your Flexible and Sensitive 3 Megapixel Microscope Camera for Live Cell Imaging

Introducing Zyla 4.2 PLUS 82% QE and Industry Fastest Speed

BSI scmos. High Quantum Efficiency. Cooled Scientific CMOS Camera

Transcription:

Quantum efficiency (%) 100 90 80 70 60 50 40 30 BEX2-DD BV FI BU2 BR-DD New NOW AVAILABLE WITH Fringe Suppression & Low Light Imaging TECHNOLOGY Low Light Imaging Dual AR EXTENDED RANGE Ultra Sensitive Imaging 20 10 0 200 300 400 500 600 700 800 900 1000 1100 1200 Wavelength (nm) Features and Benefits Extended range Dual-AR option Superior UV-NIR broadband back-illuminated QE TE cooling to -100 C Critical for elimination of dark current Fringe Suppression Technology NIR etaloning greatly reduced (BR-DD and BEX2-DD sensor types) Up to 5 MHz pixel readout High frame rates achievable Ultra low noise readout Intelligent low-noise electronics offer the most silent system noise performance available UltraVac 1 Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year 13 x 13 µm pixel size Optimal balance of dynamic range and resolution Integrated shutter C-mount shutter as standard. Closed during readout to avoid vertical smear Cropped Sensor Mode Specialised acquisition mode for continuous imaging with fastest possible temporal resolution Enhanced Baseline Clamp Quantitative accuracy of dynamic measurements USB 2.0 connection Simple Plug & Play connection Industry-Leading Ultra-Sensitive Imaging Technology Andor s ikon-m 934 series cameras are designed to offer the ultimate in high-sensitivity, low noise performance, ideal for demanding imaging applications. These high resolution 1024 x 1024 CCD cameras boast up to 95% QE max, high dynamic range, 13 µm pixels and exceptionally low readout noise. The ikon-m benefits from negligible dark current with industry-leading thermoelectric cooling down to -100 C. The Deep Depletion sensor option offers ultimate performance for NIR applications, the new Dual AR coating extends the QE performance significantly across the UV/visible region of the spectrum for the broadest possible spectral coverage from one sensor. Fringe Suppression Technology radically minimizes etaloning effects in the NIR. Rapid vertical shifts combined with fast kinetics acquisition mode, comprehensive trigger modes and custom coated wedge window options, render the deep Depletion models ideal for NIR optimized Bose Einstein Condensation applications. Specifications Summary Active pixels 1024 x 1024 Sensor size 13.3 x 13.3 mm Pixel size (W x H) 13 µm x 13 µm Active area pixel well depth 100,000 e - (130,000 e - for BR-DD and BEX2-DD models) Pixel readout rates (MHz) 5, 3, 1, 0.05 Read noise 2.9 e - Maximum cooling -100 C Frame rate 4.4 fps (full frame) Page 1 of 6

System Specifications 2 Model number DU934P DU934P (Deep Depletion) Sensor options BU2: Back Illuminated CCD, UV-Enhanced, 250 nm optimized BV: Back Illuminated CCD, Vis optimized FI: Front Illuminated CCD BR-DD: Back Illuminated CCD,Deep Depletion with fringe suppression. Optimum sensor for Near IR applications. BEX2-DD: Back Illuminated CCD,Deep Depletion with fringe suppression, extended range dual AR coating Active pixels 1024 x 1024 Pixel size Image area Minimum temperatures 3 Air cooled Coolant recirculator Coolant chiller, coolant @ 10ºC, 0.75 l/min Digitization Blemish specifications System window type 13 x 13 μm 13.3 x 13.3 mm with 100% fill factor -80ºC -95ºC -100ºC 16-bit Grade 1 as per sensor manufacturer definition BU2 sensor: UV-grade fused silica, Broadband VUV-NIR, unwedged BV sensor: UV-grade fused silica, Broadband VIS-NIR, wedged BR-DD, BEX2-DD, FI sensors: UV-grade fused silica, Broadband VUV-NIR, wedged (other options available e.g. Bose-Einstein 780nm for Rb BEC experiments) Interface USB 2.0 Lens mount C-mount Advanced Performance Specifications 2 Dark current, e - /pixel/sec 4 @ -80 C @ -100 C 0.00030 0.00012 0.01700 0.00047 Pixel readout rates 5, 3, 1, 0.05 MHz Active area pixel well depth 100,000 e - 130,000 e - Read noise (e - ) 5 0.05 MHz 1 MHz 3 MHz 5 MHz 2.9 6.6 11.6 18.0 3.3 6.2 9.2 13.6 Linearity 6 Better than 99% Vertical clock speed 11.3 to 67.3 µs (software selectable) 4.25 to 64.25 µs (software selectable) Frame Rates 7 50 khz 1 MHz 1 x 1 0.04 0.1 0.2 0.4 2 x 2 0.2 0.2 0.4 0.8 4 x 4 0.6 0.6 0.9 1.5 8 x 8 2 1.2 1.7 2.8 16 x 16 5.1 2.3 3.2 5 3 MHz 1 x 1 2.6 5.2 10 18.6 2 x 2 6.3 10.9 19.3 33.2 4 x 4 13.4 20.9 34.2 53.5 8 x 8 25.1 36.3 54.4 76.5 16 x 16 41.5 56.1 76.5 97.1 1 x 1 0.9 1.8 3.5 6.9 2 x 2 2.9 4.3 7.5 13.5 4 x 4 7.9 9.4 14.8 24.6 8 x 8 18 18.2 26.6 40.7 16 x 16 33.4 31.6 43 59.8 5 MHz Visualization mode 1 x 1 4.4 8.5 16 28.8 2 x 2 8.4 15.9 28.5 47.6 4 x 4 15.6 28.1 47 70.8 8 x 8 27.3 45.8 69.4 93.5 16 x 16 43.6 66.9 91.2 111.5 Page 2 of 6

Quantum Efficiency Curves 8 Application Image 100 90 BEX2-DD BV BR-DD 80 70 BU2 Quantum efficiency (%) 60 50 40 30 FI 20 10 0 200 300 400 500 600 700 800 900 1000 1100 1200 Wavelength (nm) The top image shows surface plots of the transition from a thermal gas (left) to a Bose-Einstein condensate. The sharp, bimodal peak in the right figure is a signature of BEC. The graph below it shows fluorescence from a few-atom MOT against time, showing the discrete steps characteristic of single atoms entering and leaving the trap. Courtesy of Prof. Michael Chapman, Georgia Institute of Technology, USA. Have you found what you are looking for? Need a larger sensor? The ikon-l 936 houses a 4 megapixel, back-illuminated CCD sensor (27.6 mm x 27.6 mm), cooling to -100 C, low noise performance and up to 5 MHz readout. Need the ultimate in sensitivity? The ixon back-illuminated EMCCD series offers > 90% QE and single photon sensitivity, combined with fast frame rate performance. Need faster frame rates? The Neo and Zyla scmos deliver up to 100 frames/sec (full frame). Need smaller pixels? Check out the Luca EM EMCCDs, the Clara Interline CCD and the Neo and Zyla scmos. Need a price/performance EMCCD? The Luca EM R is a compact 1 megapixel EMCCD USB 2.0 camera, offering high resolution and ultra-sensitivity at 12.4 frames/sec. Need a customised version? Please contact us to discuss our Customer Special Request options. Check out Andor s New Neo and Zyla scmos. Simultaneously offering, ultra-sensitivity, high speed, high-resolution, large field of view & high dynamic range! Page 3 of 6

Creating The Optimum Product for You DU934P- BV example shown How to customise the ikon-m 934: Step 1. The ikon-m 934 comes with 5 options for sensor types. Please select the sensor which best suits your needs. Step 2. Please indicate alternative window option if required. Step 3. Please indicate which software you require. Step 4. For compatibility, please indicate which accessories are required. Step 1. Choose sensor type BR-DD: Back Illuminated, Deep Depletion CCD with fringe suppression BEX2-DD: Back Illuminated, Deep Depletion CCD, dual AR coated with fringe suppression BU2: Back Illuminated CCD, AR coated for optimised performance in the 250 nm region BV: Back Illuminated CCD, Vis optimised FI: Standard front illuminated device Step 2. Select alternative camera window (optional) The standard window has been selected to satisfy most applications. However, other options are available. The alternative camera window code must be specified at time of ordering. To view and select other window options please refer to the Camera Windows Supplementary Specification Sheet which gives the transmission characteristics, product codes and procedure for entering the order. Further detailed information on the windows can be found in the Technical note Camera Windows: Optimizing for Different Spectral Regions. Step 3. The ikon-m requires at least one of the following software options: Solis Imaging A 32-bit and fully 64-bit enabled application for Windows (XP, Vista, 7 and 8) offering rich functionality for data acquisition and processing. AndorBasic provides macro language control of data acquisition, processing, display and export. Andor SDK A software development kit that allows you to control the Andor range of cameras from your own application. Available as 32 and 64-bit libraries for Windows (XP, Vista, 7 and 8), compatible with C/C++, C#, Delphi, VB6, VB.NET, LabVIEW and Matlab. Linux SDK compatible with C/C++. Andor iq A comprehensive multi-dimensional imaging software package. Offers tight synchronization of EMCCD with a comprehensive range of microscopy hardware, along with comprehensive rendering and analysis functionality. Modular architecture for best price/ performance package on the market. Third party software compatibility Drivers are available so that the ikon-m 934 range can be operated through a large variety of third party imaging packages. See Andor web site for detail: http://www./software/ Step 4. The following accessories are available: XW-RECR Re-circulator for enhanced cooling performance ACC-XW-CHIL-160 Oasis 160 Ultra compact chiller unit OA-CCFM C-mount to Canon F-mount adapter OA-CNAF C-mount to Nikon F-mount adapter OA-COFM C-mount to Olympus F-mount adapter OA-CTOT C-mount to T-mount adapter OA-ECAF Auto ext. tubes (set of 3) for Canon AF OA-ECMT Auto ext. tubes (set of 3) for C-mount OA-ENAF Auto ext. tubes (set of 3) for Nikon AF XU-RECR/TRANS USB 2.0 - Transmitter and Receiver, including 2 power supplies Page 4 of 6

Product Drawings Dimensions in mm [inches] Third-angle projection 64.0 [2.52] 47.0 [1.85] 57.0 [2.25] 208.4 [8.2] M4 x 5 deep 4 off mountings to clear 6-32 UNC 107.5 [4.23] [2.44] 62.0 52.0 [2.04] [2.04] Focal Plane of Detector 52.0 90.0 [3.54] 105.0 [4.13] 17.5 [0.69] ±0.4 [0.16] Air in (air exit opposite side) = position of pixel 1,1 Weight: 2.2 kg [4 lb 13 oz] 25.4 [1.0] 13.0 [0.51] 25.4 [1.0] 13.0 [0.51] Connecting to the ikon-m 2 off M6 x 10 deep Camera Control Connector type: USB 2.0 with optional lockable connector TTL / Logic Connector type: SMB, provided with SMB - BNC cable Fire (Output), External Trigger (Input), Shutter (Output) [1.0] 25.4 3 off 1/4-20 UNC x 1/2" deep I 2 C connector Compatible with Fischer SC102A054-130 Shutter (TTL), I 2 C Clock, I 2 C Data, +5 Vdc, Ground Minimum cable clearance required at rear of camera 90 mm Mounting hole locations Typical Applications Bose-Einstein Condensation (BEC) Astronomy Bioluminescence/Chemiluminescence In-Vivo Imaging Photovoltaic Inspection (see the ikon-m PV Inspector Specification Sheet) Fire SMB External trigger SMB Shutter SMB Power Semiconductor Analysis I²C Lockable USB 2.0 Connector Biochip Reading Rear connector panel Page 5 of 6

Order Today Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: www./contact Our regional headquarters are: Europe Belfast, Northern Ireland Japan Tokyo Phone +44 (28) 9023 7126 Phone +81 (3) 3518 6488 Fax +44 (28) 9031 0792 Fax +81 (3) 3518 6489 North America China Connecticut, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 5129 4977 Fax +1 (860) 290 9566 Fax +86 (10) 6445 5401 Items shipped with your camera 1x 2 m BNC - SMB connection cable 1x 3 m USB 2.0 cable Type A to Type B 1x Power supply with mains cable 1x Quick launch guide 1x CD containing Andor user guides 1x Individual system performance booklet Footnotes: Specifications are subject to change without notice 1. Assembled in a state-of-the-art cleanroom facility, Andor s UltraVac vacuum process combines a permanent hermetic vacuum seal (no o-rings), with a stringent protocol to minimize outgassing, including use of proprietary material. 2. Figures are typical unless otherwise stated. 3. Specified minimum air cooled temperature assumes ambient temperature of 25 C. Specified minimum temperature with coolant assumes coolant temperature of 10 C. 4. The dark current measurement is averaged over the sensor area excluding any regions of blemishes. 5. Readout noise is for the entire system. It is a combination of sensor readout noise and A/D noise. Measurement is for Single Pixel readout with the sensor at a temperature of -80 C and minimum exposure time under dark conditions. 6. Linearity is measured from a plot of counts vs exposure time under constant photon flux up to the saturation point of the system. 7. The frame rates shown are for the BR-DD model, for a range of binning or array size combinations. All measurements are made with 4.25 μs vertical shift speed. It also assumes internal trigger mode of operation and minimum exposure time. Note: 5 MHz = Visualization mode only. 8. Quantum efficiency of the sensor at 20 C as supplied by the sensor manufacturer. Minimum Computer Requirements: 3.0 GHz single core or 2.4 GHz multi core processor 2 GB RAM 100 MB free hard disc to install software (at least 1GB recommended for data spooling) USB 2.0 High Speed Host Controller capable of sustained rate of 40MB/s Windows (XP, Vista, 7 and 8) or Linux Operating & Storage Conditions Operating Temperature: 0 C to 30 C ambient Relative Humidity: < 70% (non-condensing) Storage Temperature: -25 C to 50 C Power Requirements 110-240 VAC, 50-60 Hz FM40523 EMS91062 Windows is a registered trademark of Microsoft Corporation. LabVIEW is a registered trademark of National Instruments. MATLAB is a registered trademark of The MathWorks Inc. LiKonM934SS 0514 R1 Page 6 of 6