Bio Compatibility Kit

Similar documents
Installation Note for Isocratic-to- Quaternary Pump Upgrade Kit G1352A

9 Maintenance and Repair

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Release Note for Agilent LC and CE drivers Revision A.02.14

Agilent Splitter Kits

Release Note for Agilent LC and CE Drivers Revision A.02.16

ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d.

Release Note for Agilent LC and CE Drivers Revision A.02.15

Modular Functional Fluid Circuit Guide

Release Note for Agilent LC and CE Drivers Revision A.02.17

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

9 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module. InfinityLab LC Series Diode Array Detectors User Manual

Agilent InfinityLab LC Series 1290 Infinity II Preparative Column Compartment

Agilent 1290 Infinity 2D-LC-Solution

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1)

HOW TO ORDER SWIVEL JOINTS

Release Note for Agilent LC and CE Drivers Revision A.02.19

Release Note for Agilent LC and CE Drivers Revision A SR1

Agilent SD-1 Purification Solution

Accessories for

Agilent 1290 Infinity with ISET

Brownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology

Agilent G1978B Multimode Source for 6100 Series Single Quad LC/MS

Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize.

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Agilent GC/MSD Instructions

User Manual. Agilent 1260 Infinity HPLC-Chip Cube Interface (G4240A )

Agilent 6100 Series Quad LC/MS System

Manual for the MicroSIA Instrument

MICROFLUIDIC EOF KIT 9015

Survival Laser SL-VPB Laser Parts Bundle Assembly & Operation Instructions

Preparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat Insert, Full-Bolted, and Union Type Holder

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

Economizer Regulator Filter Upgrade

2-1. the ESI Probe Assembly. the PEEK Safety Sleeve and Sample Tube to the ESI Probe

Accessories for

PLATINblue MSQ Plus. Connection Guide V6951A UHPLC/HPLC. Mass spectrometry

14. Chromatography Syringes/Microlitre Syringes

Survival Laser SL-001.4PB Laser Parts Bundle Assembly & Operation Instructions

Accessories for all your hose needs

Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions

Removal and Installation8

Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions

Preparation and Installation of the CM and CMV Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Epson SureColor F6070 Setup Guide

Agilent 1290 Infinity Binary Pump VL

Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

MX Series II Operating Manual. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

Agilent 1290 Infinity with ISET

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns to 10.0 cm i.d. -

Standard Operating Procedure

TCC-100 Thermostatted Column Compartment Quick Installation Guide August 2003 Rev. 2 Page Dionex

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

Further Information can be found at

Agilent HPLC System Firmware Bulletin

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Agilent 1200 Infinity II Series Refractive Index Detector

E1135C PDU and Pod Upgrade Procedure

RT2Y Compact temperature switch intrinsic safety

Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition

HITACHI LACHROM ELITE

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

VOYAGER PUMP DOWN PROCEDURE (BENCH-TOP MODELS)

Agilent Instrument Control Framework (ICF) Update A Driver Update 1 (DU1) Hot Fix 2 (HF2)

Vanquish. UHPLC System. Operating Manual

Introduction to the HPLC ChemStation and Acquisition

Agilent HPLC System Firmware Bulletin

Automated Fraction Re-Analysis Does it really make sense?

Using the Chromeleon Summit 2 Tandem Operation Wizard

Professional Thermostat/Reactor Vario

CBT LW 4-PUMP ADD-ON INTERNATIONAL INSTALLATION GUIDE

IOM Personal Sampler

P1P Touchscreen Installation Guide

Oven Loggermaster BEVS User Manual

Variable Area Flowmeters Installation Instructions G Series and M Series

Agilent 1290 Infinity 2D-LC Solution

Agilent Instrument Control Framework for Agilent LC/CE and GC instruments in Non-Agilent Chromatography Data Systems A.02.

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

Service Manual - Memory Upgrade

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Samsung Galaxy S8+ Battery Replacement

Pretium Rack-mountable 1U Housing Hardware

AC-43 Accelerometer. User Manual

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Removal and Installation 8

Connectivity Products

Steps for LCMS-8040 Triple Quadrupole

Video Borescope Inspection Camera

Written By: Sam Lionheart

Customers should provide all necessary operating supplies upon request of the engineer.

Spark Holland introduces

ASXPRESS PLUS Rapid Sample Introduction System Quick Installation Guide

OnePlus 5 Screen and Digitizer Assembly Replacement

Spark Holland introduces

MODEL 8000MP LEVEL SENSOR

INSTALLATION INSTRUCTIONS

Transcription:

General Information 1 Installing the 2 How to Use the 5 Important Safety and Solvent Compatibility Considerations 5 Setting the Minimum or Maximum Operating Pressure in ChemStation 7 Setting the Minimum or Maximum Operating Pressure in the Control Module 7 Parts and Materials 8 In this note the installation and use of the new are described in detail. WARNING This kit is designed for the use with operating pressures of up to 200 bar. The user must always assure that the operating pressure does not exceed this limit. Mechanical stress, exposure of the used PEEK parts to some critical solvents or operation at elevated temperatures may significantly reduce the lifetime the recommendable operating pressure of the used PEEK parts. For more details, please refer to the detailed WARNING statements inside this note on pg. 6! Features The new Bio compatibility kit offers the following features: Fits for 1100 Series Isocratic (G1310A), Quaternary (G1311A) and Binary pumps (G1312A), Standard Autosamplers (G1313A or G1329A). Minimizes metal contacts of solvents and sample. Operating pressure of up to 200 bar. General Information When to use the For the injection of samples containing Bio-Molecules and substances that should be tested for biological activity the is the option of choice, because it minimizes the exposure of samples and mobile phases to metal contacts in the flow path. Exposure of the sample substances to metal ions that could potentially lead to changes in the properties of the analytes and thus to erroneous results can be almost completely avoided. Agilent Technologies

Installing the Installing the Table 1 Requirements and preparation Description Part Number Tools required 2.5-mm hexagonal key (shipped with every ALS) 9/64 hexagonal key (shipped with every ALS) 1/4 inch wrench (shipped with every 1100 series module) Flat head screw driver 10 mm wrench or adjustable wrench Tubing Cutter (included in this kit) 8710-2412 8710-2394 8710-0510 N/A N/A 8710-1930 Parts required (for a detailed ship list please refer to Parts and Materials at the end of this note) Column (must be ordered by the user depending on the application) Bio-compatible Flow Cell, e.g. 500 nl cell for Agilent 1100 Series MWD (G1365A,B,C) or DAD (G1315A,B,C) 5065-9972 Preparations for this procedure PN G1315-68714 or Option #014 for a new instrument order Switch off the pump at the main power switch. Remove the front covers (from pump, std. ALS, thermostatted Column Cormpartment (if present) and detector. 1 Remove the standard solvent inlet filters (glass or SST frits) from the solvent bottles bottle head assemblies and replace them by the ones delivered with this kit (PTFE, PN 3150-0958). Remove the adapter holding the original frit by pulling it off the solvent tubing. A piece of sanding paper will help to slide the new PTFE filter into the tubing. Repeat this procedure for every solvent inlet tubing that will be used with this kit. Bottle head assembly with PTFE solvent inlet filter Original std. glass inlet filter Figure 1 NEW PTFE inlet filter Replacing the std. solvent inlet filters by the PTFE one 2 Use the Rhe-Flex Fittings (PN 0100-1631) delivered with this kit for connections on the high pressure side of the system (between pump outlet and the head of the column), use the std. finger tight fittings (PN 5063-6591) to connect the column outlet tubing and the flow cell. Make sure to press the tubing firmly down into the seat while tightening the fitting to avoid loose tubings and potential unwanted dead volume. 2

Installing the Finger tight Fitting Figure 2 Rhe-Flex Fitting Finger tight and Rhe-Flex Fittings for tubing connections 3 Replace the std. 0.17 mm ID (green sleeve) SST capillary that connects the pump with the Autosampler by one of the PEEK tubings delivered with this kit (either 0.18 mm ID yellow or 0.25 mm ID blue PEEK tubing). The tubing must be cut to the right length, using the tubing cutter delivered with this kit. Avoid strong curves and bends in the tubing in order not to damage the tubing. NOTE The flex-tubing (PN 0890-0316, not shown in the figures) should be used with every pressurized PEEK tubing for minimizing potential negative effects of bursting tubing. It should be cut to a length shorter than the tubing that it will be used with (tubing length - 2 times fitting length) and slid across the tubing. PEEK tubing Pump - ALS Figure 3 PEEK tubing connection from pump to Autosampler (with yellow 0.18mm ID tubing) 4 Replace the std. Rotor seal in the Autosampler s injection valve by the PEEK rotor seal (PN 0100-2231) as described in the Autosampler Reference Manual. 5 Replace the std. capillary from the Autosampler s injection valve (port 2) to the bottom of the metering head by the PEEK tubing included with this kit (PN G1313-87306). 6 Replace the std. sample loop from Autosampler s top of the metering head to the needle by the PEEK loop included with this kit (PN G1313-87309). 7 Replace the std. needle assembly by the needle assembly (PN G1313-87203) for the use with the PEEK needle seat (PN G1313-87104). Strictly follow the procedure 3

Installing the described in the manual and use the operating Software s maintenance step functions for removing, re-installing and aligning the needle. PEEK tubing from pump PEEK sample loop Needle for PEEK seat PEEK needle seat and seat capillary Figure 4 Tubing injection valve to metering PEEK rotor seal in injection valve PEEK tubing to column Replacing parts in the Autosampler 8 Remove the std. needle seat, following the procedure described in the Autosampler Reference Manual. 9 Using a 10 mm wrench or adjustable wrench and a 1/4 wrench, connect the PEEK needle seat (PN G1313-87104) to the PEEK seat capillary (PN G1313-87302). Mind the orientation of the capillary as shown on the photo. Figure 5 Connecting the PEEK needle seat to the PEEK seat capillary 10 Install the new PEEK needle seat and capillary assembly into it s holder in the Autosampler. Slide the seat and capillary into the holder by feeding the tubing in from top to bottom. Be careful not to damage the seat tubing by bending it too much! 4

How to Use the 11 Replace the std. 0.17 mm ID (green sleeve) SST capillary that connects the Autosampler to the column with one of the PEEK tubings delivered with this kit (either 0.18 mm ID yellow or 0.25 mm ID blue PEEK tubing). The tubing must be cut to the right length, using the tubing cutter delivered with this kit. Avoid strong curves and bends in the tubing in order not to damage the tubing. NOTE The flex-tubing (PN 0890-0316, not shown in the figures) should be used with every pressurized PEEK tubing for minimizing potential negative effects of bursting tubing. It should be cut to a length shorter than the tubing that it will be used with (tubing length - 2 times fitting length) and slid across the tubing. Figure 6 Tubing connections to and from the column 12 Replace the std. 0.17 mm ID (green sleeve) SST capillary that connects the column to the flow cell with one of the PEEK tubings delivered with this kit (either 0.18 mm ID yellow or 0.25 mm ID blue PEEK tubing). The tubing must be cut to the right length, using the tubing cutter delivered with this kit. Avoid strong curves and bends in the tubing in order not to damage it. Depending on the type of flow cell that is used in the detector, it might also be possible to directly connect the flow cell inlet tubing to the outlet of the column (as shown in the figure above). 13 We recommend to use this kit in combination with a bio-compatible flow cell, such as the 500 nl cell for the Agilent 1100 Series MWD (G1365A,B,C) or DAD (G1315A,B,C), PN G1315-68714 or Option #014 for a new instrument order. How to Use the Important Safety and Solvent Compatibility Considerations PEEK tubing can be used instead of stainless steel tubing in most applications. PEEK is inert to almost all organic solvents and is well known for its excellent bio-compatibility. Unlike metals, plastics are viscoelastic and, therefore, the yield strengths are not well defined. Therefore, we like to call your attention to the 5

How to Use the information, provided below regarding the many factors, which affect the burst pressure of PEEK tubing. In addition, the bending of the loop during the injection cycle of the Agilent ALS (G1313A or G1329A) adds additional stress and can shorten the lifetime of the PEEK loop capillary. We recommend checking the PEEK tubing on a regular base for leaks or other damages. WARNING The parts are designed for operating pressures lower than 200 bar, except when used with any of the critical solvents mentioned below. Never operate instruments with the Bio Compatibility kit installed at pressures higher than 200 b ar. We suggest you use caution, when working with any polymer tube under pressure. Exposing PEEK tubing to DMSO, THF and Methylene Chloride may cause the tubing to swell. Concentrated nitric and sulfuric acids will also degrade PEEK tubing. It is not recommended to use PEEK tubing with any of these solvents. Some Chlorinated Solvents, Alcohols, Ethers, Organic and Inorganic Acids or Sulfonated Compounds may reduce the lifetime and the burst pressure of PEEK tubing, especially if they are used in combination with elevated temperatures. For more detailed information about the solvent compatibility of PEEK tubing, please refer to the information given by some of the PEEK tubing vendors, such as: http://www.upchurch.com and http://www.rheodyne.com Never run the built in Pressure Test in the Agilent ChemStation s Diagnosis View for testing the leak tightness of a system that has the installed. The test is operated at pressures of 390 bar and above, which can result in bursting capillaries. The front doors of the HPLC modules equipped with the PEEK tubing must always be installed to avoid potential harm to the health of the user if a PEEK tubing bursts due to an overpressure or blockage. Always wear eye protection, when in close proximity to pressurized polymer tubing. Always use the Maximum Pressure Feature in the pump Settings, set to a value of 200 bars or below, to generate an immediate shutdown of the system, when the pressure rises above this Setting because of a blockage, too high flow or high solvent and sample vicosity. Extinguish all nearby flames if using flammable solvents. Do not use PEEK tubing that has been severely stressed or kinked. With high solvent flow rates, particularly with organic solvents, a static charge may build up on the surface of the tubing. Electrical sparking may occur. Take appropriate action to avoid any related danger. Electrically ground all modules that are part of the system. NOTE The Minimum Pressure feature in the pump Settings, might be used, set to a value of e.g. 10% below the minimum expected pressure during each run, to generate an immediate shutdown of the system, when the pressure falls below this Setting due to a leak. 6

How to Use the Setting the Minimum or Maximum Operating Pressure in ChemStation The setup of the Pressure Limits Setting is available by selecting Set up Pump from the context menu that pops up after clicking onto the Pump icon in the System Diagram of the Graphical User Interface in the ChemStation s Method and Run Control or by selecting Set up Pump from the Instrument menu in the Menu bar. Enter a value of maximum 200 bar for the Max. Pressure Limit and e.g. 10% below the expected minimum pressure during each run for the Min Pressure Limit in the top right corner of the upcoming Set up Pump Window. Operating pressure limits Figure 7 Pump Settings using the Maximum Pressure Setting in ChemStation Setting the Minimum or Maximum Operating Pressure in the Control Module The setup of the Pressure Limits Setting is available by pressing <F1> Settings from the Analysis View and then selecting the pump. In the upcoming Pump Settings screen, select <F3> Pressure. Highlight the Upper/Lower Pressure Limits using the Up/Down-Arrow keys and enter a value of maximum 200 bar for the max. pressure and e.g. 10% below the expected minimum pressure during each run for the Min Pressure Limit. Operating pressure limits Figure 8 Pump Settings using the Maximum Pressure Setting in the Control Module 7

Parts and Materials Parts and Materials Parts 5065-9972 Table 2 Parts for G1310A Isocratic, G1311A, Quaternary and G1312A Binary Pumps and G1313A and G1329A 1100 Series Standard and Thermostatted Autosamplers Description Part Number 1 Rotor seal, PEEK, 2-groove for 0101-0921 (for injection valve) 0100-2231 2 ZDV union, PEEK, with Fitting (for capillary to capillary connections) 0100-2441 3 Rheflex fittings, 5/PK (for connections to the tubings on the high pressure side of the system, i.e. upstream of the column) 0100-1631 4 Bio compatibility Kit Note (this note) 01100-90105 5 TUBING-FLEX.081-ID TFE.016-W (hose, for leak protection on PEEK tubings) 0890-0316 6 1/16" od 0.01" id 0.25mm, 1.5m/5 feet length, BLUE PEEK tubing (pump to sampler, sampler to column, column to detector flow cell tubing) 7 1/16"od 0.007"id (0.18mm), 1.5m/5 feet length, YELLOW PEEK tubing (pump to sampler, sampler to column, column to detector flow cell tubing) 0890-1762 0890-1763 8 4x FILTER PTFE LAST DROP 10UM TRIPOD TUBING (solvent inlet filter) 3150-0958 9 PEEK finger-tight fittings 1/16 in, 10PK (for PEEK tubing connections) 5063-6591 10 Plastic tubing cutter 8710-1930 12 Seat Assembly PEEK ALS G1313-87104 13 Needle Assembly for use with PEEK seat G1313-87203 14 PEEK Seat Tubing Assembly 0.17 G1313-87302 15 PEEK Valve to Metering Capillary G1313-87306 16 PEEK Sample Loop Capillary for 100ul Sample G1313-87309 Agilent Technologies 2005 Part Number: 01100-90105 *01100-90105* *01100-90105* Edition: 6/2005 Printed in Germany Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn