Thank you for choosing the DIL LaserMount from Arroyo Instruments. The DIL LaserMount is designed for high performance and long term use.

Similar documents
The Butterfly LaserMount also offers all the features you would expect from a modern butterfly laser diode fixture, including:

Page 2 262/264 LaserMount User s Manual. Table of Contents

Page LaserMount User s Manual

Page TECMount User s Manual. Table of Contents

Laser Diode Controller Instruction Manual

Sacher Lasertechnik Group

Butterfly Laser Diode Mount

FIRST, A WORD ON SAFETY

Sacher Lasertechnik Group

Precision Instrumentation for Lasers and LEDs

Thermoelectric Cooler Controller TED1000

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

DBR Laser Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

DATASHEET AND OPERATING GUIDE LDMOUNT-5A

Model 500 Series Laser Diode Driver User's Manual

# 6. Choosing the Right Laser Diode Mount for Your Application

Gateway Profile 4 service guide

PLD Series +5V Laser Diode Drivers

PMDX-105 Quad Isolator Board

Precision Instrumentation for Lasers and LEDs

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Hybrid AC Driver [GCNC-1110]

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

The new 6300 Series. The new dual range

Ultra Low Noise Laser 1550nm

SATA II HDD Canister KISS DA 435 Quick Reference Guide

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Adjustable Timing Control PN 8680

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

INSTRUCTION MANUAL. IN-WALL DOCKING SYSTEM for ipod INTRODUCTION BOX CONTENTS. iport REAR-PANEL CONNECTIONS. Figure 1: iport Connections

600 mw Fiber Bragg Grating Stabilized 14xx nm Pump Modules with Ultra-Low Power Consumption. S35 Series

Adjustable Timing Control PN 8680

Global Water Instrumentation, Inc.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

OWNER S MANUAL Calc-U-Dri PRINTER

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

SMD Series Integrated Stepper Driver and Motor Revision 1.3

TEC 2000 INSTRUCTION MANUAL TEC SERIES

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Keysight M8000 Series BER Test Solutions

MPP200 User s Manual

RangerBOSS Network Ready Constant Monitor Model CM2800

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

DMX Switch Pack. User Manual. EU version shown P/N

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

Enclosure TS-530 User Manual

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

Installation Manual. Table of Contents

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

Proliphix EPA-60 Installation Guide

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

EP/2 Installation Instructions

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

V8/V80. Installation manual. Version 5.0

USB 2.0 LR 4-Port Extender

FA-2448 SIX POSITION Filter Wheel

Integrated Stepper Drive & Motor

Page Series ComboSource User s Manual. Table of Contents

BCD Interface for the 520 Indicator DISCONTINUED. Installation and Configuration Manual Rev A

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Installing The Loop Start Line Board In The FX Series Digital Communications System

PIM-Mini Pulsed Current Source Operation Manual

BCD Interface for the 520 Indicator. Installation and Configuration Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

Page TECSource User s Manual

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL

TSD-DA28 2x8 Balanced Line Distribution Amplifier

N+1 DC Power System with Battery Backup / Charging Function

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Compact Laser Diode Driver Version 2.4 cldd User s Guide

OP8662 High Voltage and Current Probe User Guide.

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

120Ra-1 Pentium III Processor Installation Insert

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

CAT U S E R M A N U A L

SynJet PAR25 LED Cooler with Heat Sink

Spec Tech Industrial Electric Technical Support. Model: DL34-(XX) Quick Start

Resolver to Digital Expansion Board

QuickTouch (QT4) Owner s Manual

Page 2 LaserPak User s Manual. Table of Contents

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

PCM-7140 Pulsed Current Source Operation Manual

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

BUGLE2 MM / MC Phonostage PCB

Transcription:

Page 2 212/214 DIL LaserMount User s Manual Introduction Thank you for choosing the DIL LaserMount from Arroyo Instruments. The DIL LaserMount is designed for high performance and long term use. For applications requiring case temperature control, the 214 TEC DIL LaserMount integrates an 8W Peltier cooler for precise control of the package temperature. With an operating range of -5 C to 85 C, the TEC DIL LaserMount should cover most of your case temperature control needs. Both DIL LaserMounts are heavily finned to provide the highest heat dissipation capability, allowing you to operate at more extreme conditions or higher powers. Both mounts also have an array of screw down mounting options available with the removable base. The 212 DIL LaserMount can also be used for mini-dil devices, although it does not provide any heat sinking capability. The DIL LaserMount also offers all the features you would expect from a modern DIL laser diode fixture, including: Designed to be quickly integrated with Arroyo s LaserSource and TECSource instruments. Industry-standard D-sub connectors and pin-outs allow for quick integration into existing laser applications. Screw terminals for all 8 or 14 pins of the device, allowing for easy, solder-less configuration of the fixture. The 214 TEC DIL LaserMount features three standard connectors, eliminating the need for custom cabling to the two TEC interfaces.

212/214 DIL LaserMount User s Manual Page 3 Installation and Use Wiring the mount to your device: Start by configuring the wiring of the mount to match your DIL or mini-dil laser. To do this, remove the four screws from the bottom of the fixture and lift off the base plate. This will give you access to the screw terminals inside the fixture. Internal Wiring Example Using the wiring guide below, connect the wires to the appropriate pins of the DIL or mini-dil. The wires are color coded for easy identification.

Page 4 212/214 DIL LaserMount User s Manual Signal Color Laser Anode Red Laser Cathode Black Photodiode (PD) Anode Green Photodiode (PD) Cathode White Chassis Ground Brown TE (+) Orange TE (-) Yellow Thermistor Blue Thermistor Violet Fixture Wiring Guide CAUTION Make sure the LaserMount is earth grounded. The 1220 LaserSource and 1260 TECSource cables ground the fixture to earth ground through the shell connector. If you are not using 1220 and 1260 cables, make sure the LaserMount is grounded through the DB9 or DB15 connectors, or via the banana jack. Your mount was shipped with four rubber feet, which can be used if the fixture will not be bolted to an optical bench or other mounting system. The feet prevent the fixture from skidding on a smooth surface. If you plan to use the feet, install them now in the four corners of the label side of the bottom plate. Once you have wired the mount for your device and optionally installed the feet, place the base plate back on the mount and screw in the four screws. Connect to Laser Diode Driver and TEC Controller: Next, connect the DIL LaserMount to your laser diode driver and temperature controller. For the 214 TEC DIL LaserMount, you will need a second temperature controller for the case temperature control. NOTE Arroyo Instruments offers Laser and TEC cables designed to connect directly between our LaserSource and TECSource products. If you use your own cables, ensure the connections are properly made between the instrument and the mount, and that proper grounding techniques are used. The pin-out of the connectors can be found later in this document.

212/214 DIL LaserMount User s Manual Page 5 WARNING Be sure you are properly ESD protected before handling your laser. For additional information, read the section titled Laser Diode Protection later in this manual. Mounting your device: Remove the two small mounting screws from the DIL mounting plate, open the ZIF socket, and carefully place your DIL or mini-dil laser into the ZIF socket. Make sure the fiber is exiting through the gap provided in the front of the mount. For DIL devices, screw in the mounting screws, but do not over tighten, as you can strip the threads in the mounting plate. For mini-dil devices, leave the screws out of the fixture. Close the ZIF socket. Loading of the Device Your mount is now ready for use. Additional technical information can be found below.

Page 6 212/214 DIL LaserMount User s Manual Connector Pin-Outs 212 DIL LaserMount Connectors 214 TEC DIL LaserMount Connectors DB-9 Pin Description 1 & 2 No connection 3 Chassis Ground (GND) 4 & 5 Laser cathode 6 Photodiode cathode 7 Photodiode anode 8 & 9 Laser anode Laser DB-9 Connector Pin-Out On the 214 TEC DIL LaserMount, both TEC DB-15 connectors are pinned identically. DB-15 Pin Description 1 & 2 TE (+) 3 & 4 TE (-) 7 Thermistor 8 Thermistor 5, 6, 9 15 No connection TEC DB-15 Connector Pin-Out

Technical Specifications FICATIONS 212 DIL LaserMount LASER PACKAGE SUPPORTED Package INPUT CONNECTOR Laser Diode Laser TEC 212/214 DIL LaserMount User s Manual Page 7 14-pin DIL or 8-pin mini-dil (mini- DIL electrical connection only) DB-9, male DB-15, male 214 TEC DIL LaserMount TEMPERATURE CONTROL Temperature Range ( C) 1-5 to +85 Sensor Type 10kΩ Thermistor TE Module Imax = 3.9A Vmax = 3.75V Qmax = 8.2W LASER PACKAGE SUPPORTED Package 14-pin DIL INPUT CONNECTOR Laser Diode DB-9, male Laser TEC DB-15, male Mount TEC DB-15, male GENERAL Size w/ base (H x W x D) [in(mm)] 1.55(38) x 4.50(114) x 5.00(127) Size w/o base (H x W x D) [in(mm)] 1.35(34) x 3.50(97) x 5.00(127) Mounting holes ¼-20 through-hole, 4 on center (x2) 8-32 threaded holes (x4) M5 threaded holes (x4) Device mounting screws 4-40 x ¼ Socket Head Cap Screw 1 Temperature control range is dependent on the power dissipated into the heat sink. Mounting fixture to an optical table will increase the heat dissipation capability.

Page 8 212/214 DIL LaserMount User s Manual Mechanical Specifications Top View Bottom View with Base Plate Removed

212/214 DIL LaserMount User s Manual Page 9 Laser Diode Protection Electrostatic discharge and current spikes can be a significant cause of damage to laser diodes, but when proper precautions are taken, these risks can be greatly reduced or eliminated. Arroyo Instruments controllers offer state-of-art laser diode protection, but no instrument can fully shield the laser from damage. Please take these considerations into account when operating your laser: 1. Always set the current limit at or below the maximum current your laser can handle. This prevents the device from accidentally driving the current too high, either via the set point or from the modulation port. This also provides additional current limiting protection from ESD. 2. Always work in an ESD safe operating environment, including the use of wrist straps, ESD grounded work surfaces and floors, and ESD-safe tools. 3. Where the AC power to the laser driver to temperature controller may be noisy, use isolation transformers or uninterruptible power supplies that provide isolation. 4. Make sure all cables are securely connected and fastening screws are screwed in tight. 5. Do not route power cords or other cables in parallel with the laser or temperature controller cables, as coupling may occur between the cables and inject noise into the laser diode. 6. While it is not possible to create a ground loop through the LaserSource because of it s isolation of all inputs, it is possible when using other equipment. Ensure that any other equipment is properly isolated to avoid any ground loop problems. For additional ESD protection, adding 3.5μH (Mouser P/N 542-FB73-287) ferrite beads as close to the laser diode as possible is recommended. One ferrite bead should be used on each laser diode and photodiode diode anode and cathode, with the wire going through the bead at least twice (two turns).

Page 10 212/214 DIL LaserMount User s Manual Warranty Arroyo Instruments warrants this product to be free from defects in material and workmanship under normal use and service for a period of one (1) year from date of shipment. It does not apply when the product has been misused, altered or damaged by accident or abnormal conditions of operation. If found to be defective during the warranty period, the product will either be repaired or replaced at Arroyo Instruments's option. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. ARROYO INSTRUMENTS SHALL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM THE PURCHASE OR USE OF ITS PRODUCTS. Service and Support For service and support, contact your local distributor or Arroyo Instruments. Telephone: +1 (805) 481-6684 Facsimile: +1 (805) 481-6628 Email: support@arroyoinstruments.com Web: http://www.arroyoinstruments.com Address: 373 Front Street, Suite B Grover Beach, CA 93433 USA