Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration, ir Conditioning and Resistance Heating and are manufactured to traditional Cutler-Hammer standards for quality and reliability. They are subjected to stringent quality assurance inspections and Number Selection Table 1. Definite Purpose Control Numbering System testing procedures. The life expectancy, both electrical and mechanical, will meet or exceed industry performance requirements for Definite Purpose devices. If more detailed technical information is required specifications, ratings, etc. contact your local Eaton distributor or sales office. C D N 1 1 1-8 Model C = Contactor = Three-Phase Starter B = Single-Phase Starter Type = Non-reversing & Starters 7 = Non-reversing Starters 9 = Non-reversing Starters = Reversing Contactor Frame Size = Compact 1-Pole B = Compact -Pole C = Compact 1-Pole W/Shunt D = 1, - and -Pole E =, -Pole F = 0 7, - and -Pole G = 90, - and -Pole H =, - and -Pole K = 00 and 00, -Pole L = 0, -Pole For Starters Only C = Common Control Wiring S = Separate Control Wiring Enclosure Type N = Open with Metal Mounting Plate R = Open with DIN Rail Mounting dapter (- and -Pole, 1 Only) G = NEM Type 1 Enclosed Power Terminals = Binding Head Screw B = Binding Head Screw and Quick Connect Terminals (side by side) C = Screw/Pressure Plate D = Screw/Pressure Plate and Quick Connect Terminals (side by side) E = Box Lugs (Posidrive Setscrew) F = Box Lugs (Posidrive Setscrew) and Quick Connect Terminals (side by side) G = Binding Head Screw and Quick Connect Terminals (vertical in-line) H = Screw/Pressure Plate and Quick Connect Terminals (vertical in-line) J = Box Lugs (Posidrive Setscrew) and Quick Connect Terminals (vertical in-line) K = Box Lugs (Hex Socket llen Head Setscrew) L = Box Lugs (Hex Socket llen Head Setscrew) and Quick Connect Terminals (side by side) M =Box Lugs (Hex Socket llen Head Setscrew) and Quick Connect Terminals (vertical in-line) Not available on devices. No. of Poles 1 = 1-Pole = -Pole = -Pole = -Pole Bulk Packaging Blank = individual pkg. -8 = 0 pc./pkg. (CD_) pc./pkg. (C_, CB_, CC_) -8 = Rotate coil terminals 180 for 1 Fuse Blocks = Class M, 00V, 0 7 = Class G, 00V, 1 8 = Class G, 00V, 0 1 = Class G, 00V, 0 = Class G, 00V, 0 1 = Class J, 00V, 0 = Class J, 00V, 0 = Class T, 00V, 0 = Class T, 00V, 0 1 = Class T, 00V, 0 = Class T, 00V, 0 1 = Class H, V, 0 = Class H, V, 0 1 = Class R, V, 0 = Class R, V, 0 uxiliary Contacts (Side Mount) = 1NO Pressure Plate B = 1NC Pressure Plate C = 1NO-1NC Pressure Plate D = NO Pressure Plate E = NC Pressure Plate F = 1NO Pressure Plate and QC G = 1NC Pressure Plate and QC H = 1NO-1NC Pressure Plate and QC J = NO Pressure Plate and QC K = NC Pressure Plate and QC L = 1NO-1NC Snap Switch QC Only M =NO-NC Snap Switch QC Only Coil Selection = 1 V C, /0 Hz B = 08 V C, /0 Hz C = V C, /0 Hz D = 00V C, / Hz H = 77V C, 0 Hz J = 0 V C, /0 Hz L = 80 V C, Hz 1 = 1 = 0 = 0 = = 0 = 0 Current Rating 7 = 7 90 = 90 = 00 = 00 00 = 00 0 = 0 R = 1V C, /0 Hz T = V C, /0 Hz 1R = 1V DC 1T = V DC 1W = 8V DC 1 = V DC C0001E
May 007 0, Compact 1- and -Pole C Contents Description Compact 1- and -Pole 0 Product Description...... Standards and Certifications.......... Technical Data Specifications......... Options................ Dimensions............. Product Selection........ Page Standards and Certifications UL Recognized Components: UL File Number E191, Guides NLDX and NLDX8 Certified Components: C. No. 1-0, File Number 808 Class 8 IEC 097--1 EN 097--1 Technical Data Specifications RI 780/790 Standard RoHS Compliance Compact -Pole Product Description Cutler-Hammer 0, single- and double-pole, Type C contactors from Eaton s electrical business feature a compact, efficient design with a low V coil and straight-through wiring. New contactor housing design effectively limits dust and other contaminants from magnet structure reduces or eliminates noise. These economically priced, UL recognized/ certified, ampere rated devices are well suited for use in heating/air conditioning, refrigeration, data processing and food service applications. Insulation : 90V Current Rated and hp/kw Rated Contacts: Double Break Magnet Coil: Class F, 1 C Contact rc Covers are standard on all Standard Power Terminals /1" Hex Washer Head Screws Quad () Quick Connect Terminals on all Line and Load Terminals Box Lugs available as option are marked with Line and Load Terminal Designations Operating Temperature Range: -1 to 18 F (- to 70 C) Terminal Wire Range Hex Washer Head Screws: 1 WG, 0 lb-in torque rating Box Lugs: 1 WG, lb-in torque rating; 8 WG, lb-in torque rating; WG, lb-in torque rating Mounting Position: Vertical, Horizontal or Tabletop Table. Coil Characteristics C Coil /0 Hz One-Pole 08/ 77 Two-Pole 08/ 77 Options Inrush V Sealed V Table. Compact Options Factory Installed Description..... Box lugs with quick connects for 0 contactors: 1-Pole 1-Pole with shunt -Pole To order replace letter in the th position of Number with letter F. EXMPLE: CBNF Sealed Watts dder Discount Symbol...................... 1CD-C C0001E
0, Compact 1- and -Pole C May 007 Product Selection When Ordering Specify Number plus Magnet Coil Suffix. Modify Number for any options required see factory installed Options Page. Table. Numbering System CBNB0 Incomplete Number Magnet Coil Suffix Compact 1-Pole Compact 1-Pole with Shunt Table. Compact Product Selection Open Type mpere Ratings Motor Horsepower Inductive Full Load Resistive Single-Pole 0 0 Single-Pole with Shunt 0 Double-Pole 0 0 0 0 Motor Kilowatts Locked Rotor 77V V 00V V 0V V 0V 1 1 1 1 1 1 7 00 7 00 0 1 1 00 80 0 0 Rating per pole. Incomplete Number. Replace underscore (_) in Number with Coil Suffix letter from Table. Bulk pack quantities are available in quantities of, contact local sales office. 1-1/ 7-1/ 7-1/ 7-1/ 1. 1.. 1. 1.. 1.1 1. 1....7...7....7. CNB1_ CNB_ CNB1_ CCNB1_ CCNB_ CCNB1_ CBNB0_ CBNB_ CBNB0_ CBNB_ 1.00 0. 7...00 7.00.00 7. 91. Dimensions Compact -Pole Table. Magnet Coil Selection C Coil /0 Hz 1 08 77 80 ( Hz); (0 Hz) Coil Suffix T B H C 0.0 (0.8) 0.1 (.) 0. (.) 0.0 (0.8) 0.1 (.) 0. (.) 1. 1.77. (8) () (1).19 (81) 1. 1.77. (8) () (1).19 (81) 1.1 () 1.97 (). (9) 1.1 () 1.97 (). (9) 1-Pole and 1-Pole +Shunt Ship. Wt.: 0. lb. (0. kg) -Pole Ship. Wt.: 0.7 lb. (0. kg) Figure 1. Compact pproximate Dimensions in Inches (mm) and Shipping Weights Technical Data....................... Page Options.............................. Page Discount Symbol..................... 1CD-C C0001E
May 007 1 0, -, - and -Pole C mm DP Contactor Product Description Cutler-Hammer Type C Definite Purpose 1 through 0, from Eaton s electrical business incorporate most competitive contactor mounting dimensions into a single baseplate. are dual-rated with inductive and resistive ratings as well as horsepower and kilowatt ratings. C contactors are furnished with pressure plates and quick connect terminals as standard on 1, and 0 devices and with box lugs and quickconnect terminals on,, 0 and 7. Other terminal configurations are available, see Table 1. will accept add-on auxiliary contacts order factory assembled or as kits for field installation. The separately available snap-on mechanical interlock permits interlocking two contactors for reversing or two-speed applications. rated 1 only are available with DIN rail mount as a factory installed option. Standards and Certifications UL Recognized Components UL File #E-191, Guide NLDX Certified Components File #LR, Class 0, 81 & 1 IEC 097--1 EN 097--1 RoHS Compliance (1 to Only) Technical Data and Specifications Magnet coil: Class B (CE, F, G, H and K), C Class F (CD and L), 1 C Class H (CD), 180 C (vailable as factory installed option) Contacts: Double break Coil terminals: 1 WG mbient temperature: 1 F ( C) maximum UL recognized, certified and conform to RI 780 CE mark Terminal wire range: #8 binding head screw: 1 1 WG (one conductorsolid) #8 screw/pressure plate: 1 8 WG (one conductor) 1 8 WG (two conductors) Box lugs 1 : # posidrive screw or / hex socket screw Upper Level: 1 WG (one conductor) Lower Level: 1 WG (one conductor) Box lugs 0 7 Upper Level: 1 WG Lower Level: 1 WG Note: The box lugs on the 1 7 device can accept two conductors per pole. Box lugs 90: 1/0 1 WG Box lugs : /0 8 WG Box lugs 00 00: MCM WG Box lugs 0: 7 MCM WG Table 7. Lighting Duty Ratings ( to Only) Table IEC/CE Ratings (IEC 097--1, EN 097--1) for 1 through CD_ CD_ C-1 (Ic) C- (Ie) C- (Ie) C-8a Inductive Rating V 00V V 00V V 00V V 00V 1 0 0 0 0 0 1 0 Table 9. DC Ratings (1 to Only) -Pole, 1 0 Inductive DC-/ DC- 1 0 CD_ Inductive Rating 0 -Pole, Inductive 1 0 DC-/ DC- Tungsten & Ballast (V) 0 0 Table. Contactor Torque Ratings Contactor Size Terminal Wire Range Tightening Torque The box lugs on the 1 device can accept conductors per pole, the upper section will accept 1 WG and the lower section will accept 1 WG. The box lugs on the 0 7 device can accept conductors per pole, the upper section will accept 1 WG and the lower section will accept 1 WG. -Pole, 1 0 Inductive DC-/ DC- 1 0 1 0 -Pole, Inductive FL hp I e FL hp I e FL hp I e FL hp I e V DC Poles in Series / 1 V DC Poles in Series 8 / 8 1 V DC Poles in Series. 1/. 8 / 8. 1/. 8 / 8 V DC per Pole 1/. 1/. 1/. 1/. V DC per Pole 1 1 0 0 1 1 0 0 1 8 Binding Head Screw 1 1 WG lb-in Screw/Pressure Plate 8 1 WG 1 lb-in Box Lug 1 1 WG WG 8 WG WG 1 lb-in lb-in lb-in lb-in 0 7 Box Lug 1 WG 8 WG WG lb-in lb-in lb-in 90 Box Lug 1/0 1 WG 0 lb-in Box Lug 8 WG WG 1/0 WG lb-in lb-in lb-in 00 00 Box Lug MCM 00 lb-in 0 Box Lug 7 MCM lb-in DC-/ DC- C0001E
1 0, -, - and -Pole C May 007 Product Selection When Ordering Specify Number plus Magnet Coil Suffix, below. Incomplete Number. Replace underscore (_) in Number with Magnet Coil Suffix from table below. Carton quantities including 0 individually packaged units are available for - and - pole units through 0 inductive. with DC coils (only available up to 7) include an early break NC auxiliary contact, C0KGD1. See Page for more details. vailable only for 1 through 7 contactors and -pole contactors. vailable through 7. vailable through. vailable 0. vailable 1 90, others V. vailable through. Modify Number for any options required see Options, Page 7. Numbers of accessory kits required, Page 7. Table 1. C Product Selection Open Type Rating, mperes Maximum Motor Maximum Motor Horsepower Kilowatts Inductive Resistive Line Locked 1-Phase -Phase 1-Phase -Phase Full Load per Pole Rotor 1 0 0 7 0 7 0 0 7 0 7 0 7 0 7 0 7 7 90 0 7 90 0 7 1 0 7 00 00 00 00 00 00 0 0 00 90 90 7 0 1 1 1 0 180 180 1 00 00 00 00 0 0 00 7 00 0 70 70 70 0 0 00 1800 1800 0 0 1900 / 7-1/ 1 7-1/ 0 7-1/ 1 1 0 0 1 0 0 0 0 0 0. 1. 1.. 1..7... 7..7 7..7.7 1.1..7.7. 7. 7. 7. 7. 1 1 1 0 0 1 7 7 7 7 Table 1. Magnet Coil Selection 0 Hertz Hertz C 1 1 1 1 08 08 08 0 77 80 00 00 DC 1 8 Number of Poles Table. Numbering System CDND1 X Incomplete Number Open Type with Metal Mounting Plate CDND1_ CDND1_ CDND_ CDND_ CEND_ CDND0_ CDND0_ CEND_ CDNF_ CDNF_ CENF_ CDNJ_ CDNJ_ CFNF0_ CFNF0_ CFNF7_ CFNF7_ CGNF90_ CGNF90_ Magnet Coil Suffix 00 00.00 00 9. 1.00 1.00.00 17.00 180.00 197.00 1.00.00 91.00 1.00.00 87.00 Option Code as necessary Open Type with DIN Rail dapter CDRD1_ CDRD1_ CDRD_ CDRD_ CDRD0_ CDRD0_ CDRF_ CDRF_ CDRJ_ CDRJ_.00 7.00 7.00 81.00 81.00 800 9.00.00 171.00 187.00 N N N CHNE_ 7.00 N CKNE00_ 1,180.00 N CKNE00_,0.00 N CLNE0_,.00 N Coil Suffix R T E B J H L C D 1R 1T 1W 1 V /0 Hz for 0, 7 and all -Pole ( ). Class H C Coils available as option for 1 Contactor. dd before C Coil Suffix letter. Technical Data.................... Pages, Options........................... Page 7 ccessories...................... Page 7 Dimensions....................... Page 1 Discount Symbol.................. 1CD-C C0001E