NMEA 2000 to NMEA 0183 Gateway NGW-1-ISO. Installation Manual

Similar documents
NGW-1. NMEA 2000 to NMEA 0183 Gateway. User Manual

Quick Network Block QNB-1-B. User Manual

NMEA Data Combiner NDC-3-B. User Manual

NBF-3. User Manual. NMEA 0183 Buffer. For all variants: NBF-3-BAS, Rev A. Issue 1.01

NMEA Buffer NBF-2-A. User Manual

NMEA Data Combiner NDC-3-B-USB. User Manual

NMEA Conversion Gateway Install/User Manual

NMEA Reader (v3.031) & EBL Reader (v1.090) Full User Manual

EMU-1. User Manual. Engine Monitoring Unit Analogue to NMEA For variant: EMU-1-BAS, Rev A. Issue 1.03

NMEA Data Multiplexer NDC-4 For all variants: NDC-4, NDC-4-USB, NDC-4-ASW NDC-4-AIS, NDC-4-AIS-USB. Install User Manual

NMEA Data Combiner. User Manual

Professional NMEA 0183 Multiplexer Install/User Manual

NMEA 0183 Multiplexer Install/User Manual

Your complete guide to building an NMEA 2000 network. Issue 1.1

intelligent monitoring solutions C A N t r a k C O N F I G U R A B L E I N P U T M O D U L E ( C C I M ) I N S T A L L A T I O N M A N U A L

NMEA Data Multiplexer NDC-4 For all variants: NDC-4, NDC-4-USB, NDC-4-ASW NDC-4-AIS, NDC-4-AIS-USB. Full User Manual

MEV Limited USB232/485 INSTRUCTION MANUAL

NMEA Data Combiner NDC-2-C. Full User Manual

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

F1000 User's Manual. (Version: V1.01)

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

LVX Control Unit. Features:

General Operating, Maintenance and Installation Manual

Installation Instructions

Strain Gage Measuring Amplifier GSV-3

PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

QK-A031 NMEA 0183 Multiplexer with SeaTalk Converter Features

Installation Instructions

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

ELAN DIGITAL SYSTEMS LTD.

PCI Express Powered USB Card

R507 I.S. Interface Module User Manual

Sauter Systems

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

Distributed Intrinsically Safe Fieldbus Applications

Altair RU. Owner s Manual. Document name: AtrRU-EN Document version: 0.3 Release date: 25/03/2009

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

IC232 PC- CARD USER S GUIDE

General Specifications. P2-SCM Serial Communications

PCI Express 4-Port Industrial Serial I/O Cards

Triple Touch DIMMER for Low Power LEDs

Product Data Sheet. BMS/Graphics Interface. Features

PRESSURE TRANSMITTER

Instruction Manual. T3110 T3110L T3110Ex

ELAN DIGITAL SYSTEMS LTD. CF428 COMPACT FLASH CF+ CARD USER S GUIDE

Installation Operation & Specifications Manual. General Description

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

LCI Load Cell Junction Box with Fault Monitor

Windows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

CANdoISO Module Datasheet

Operating instructions. Standstill monitor A / / 2011

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Windows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

Installation Guide Controller Series E130/E230/E430

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Operating instructions. Switching amplifier DN0210 DN / / 2015

HART UNIVERSAL TEMPERATURE TRANSMITTER

Product Catalogue.

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

UNIVERSAL TEMPERATURE TRANSMITTER

HART Modem for USB. Features. Description. Datasheet HmUSB-01 December Ideal for configurations, data acquisition and digital control.

Kvaser Leaf User Guide

Instructions manual / DPC Touch Firmware Upgrade 1. DPC Touch Firmware Upgrade SERVICE MANUAL

Owners Manual i-bdl Battery Data Logger

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

ABSOLUTE ROTARY ENCODER PROFIBUS-DP

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

USB-2001-TC. USB-based Thermocouple Input. User's Guide

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

P3-SCM. General Specifications

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Super universal modules

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Installation instructions Inclination sensor EC2019 EC / / 2013

CERTIFICATE of EU TYPE-APPROVAL

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

C-Bus Pascal Automation Controller

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Future Technology Devices International Ltd. USB to RS422 Serial Converter Cable. Datasheet

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Transcription:

NMEA 2000 to NMEA 0183 Gateway NGW-1-ISO (Hardware revision A) Installation Manual Issue 1.00 Gateway between the NMEA 2000 network and an NMEA 0183 device, or the serial port of a computer running NMEA 0183 compatible software Complete electrical isolation (of 1500 volts) between NMEA 0183 serial port and the NMEA 2000 connections Fully configurable via serial port or through the NMEA 2000 network

Contents NMEA 2000 to NMEA 0183 Gateway - NGW-1-ISO Important notices 4 Notices 4 Foreword 4 Introduction 4 Technical features 5 Software updates 5 Connecting devices together 5 The NMEA 2000 standard 5 Connections 6 Connecting to the NMEA 2000 network 7 NMEA 2000 connections 7 Connecting to an NMEA 0183 device 7 NMEA 0183 connections 7 Connecting to an RS232 (PC) port 8 RS232 Connections 8 Connecting to an RS485 (IEC 61162-2) listening device 8 RS485 Connections 8 Specifications 9 Troubleshooting guide 10 Status LEDs 10 Product order codes 11 Company Information 11 Page 3

Important notices Actisense and the Actisense logo are registered trademarks of Active Research Limited. All rights are reserved. The contents of this manual may not be transferred or copied without the express written permission of Active Research Limited. All other trademarks are the property of their respective owners. The Actisense NMEA 2000 to NMEA 0183 Gateway (NGW-1-ISO) is intended for use in a marine environment, primarily for below deck use. If the NGW-1-ISO is to be used in a more severe environment, such use may be considered misuse under the seller s guarantee. The NGW-1-ISO has been certified to comply with the European directive for Electro-Magnetic Compatibility (EN60945), and is appropriately CE marked. Operation of the unit should be in conjunction with appropriate CE approved shielded connectors and cabling used in accordance with the CE directive EN60945. Any EMC related issues should be reported to Active Research immediately to allow the company to rectify or resolve EMC related problems in accordance with its obligations under EN60945. If the unit is misconnected so that compliance failure occurs, the company shall not be held responsible for compliance failure until suitable EMC guidelines for connection are seen to have been taken. Notices When using this document, please note the following: The products described in this manual and the specifications thereof may be changed without prior notice. To obtain up-to-date information and/or specifications, contact Active Research Limited or visit the Actisense website (www.actisense.com). Foreword At Active Research Limited, we recognise that instructions are often skipped, so we have aimed to write this document in an informative and direct manner that will aid the user. We have covered all the points a typical user needs to know. Please read all sections before installing and using the NGW-1-ISO, and any referenced software programs. Introduction The NGW-1-ISO allows NMEA 0183 electronic equipment to be connected to a vessel s NMEA 2000 network. This can allow equipment installers to adopt the NMEA 2000 network early, whilst connecting any existing NMEA 0183 devices to the new bus standard. The NMEA 2000 network can reduce installation costs of marine equipment and greatly reduce a boat s wiring harness complexity, leading to improved reliability and reduction in unnecessary weight. Now only a single cable is required from the bridge to the engines, sensors and all other NMEA 2000 instruments on the boat NMEA 2000 uses the CAN Bus system (prevalent in most modern cars), to provide the quality and security of data transmissions that the NMEA 0183 bus can never hope to provide. This enables NMEA 2000 products to achieve better transmission reliability in the passage of data through the vessel. The NMEA Gateway can transfer data from an NMEA 0183 source and place that data on the NMEA 2000 bus, or it can take NMEA 2000 data from the NMEA 2000 bus and make it available to the NMEA 0183 instrument. Full information on the complete Actisense product range and supporting software packages can be found on the Actisense website (www.actisense.com). Active Research Limited will not be liable for infringement of copyright, industrial property right, or other rights of a third party caused by the use of information or drawings described in this manual. Active Research Limited will not be held responsible for any damage to the user that may result from an accident during operation of this unit when used in accordance with this document. Page 4

NMEA 2000 to NMEA 0183 Gateway - NGW-1-ISO Technical features High-speed 32-bit ARM processor capable of up to 40 million instructions per second. Flash ROM technology that supports automatic programming for quick and easy updates, 10,000+ erase cycles and a 10-year Data Retention provides carefree user configuration. On-chip memory store allows buffering of short term NMEA data, allowing the unit to smooth short-term peaks in the NMEA data flow. Fully configurable via the serial connection or over the NMEA 2000 network allowing optimisation of the serial interface to better suit the system it is a part of. NMEA 2000 interface offers 2500 volts of opto-isolation, protecting the system even during the most extreme fault conditions and fully compliant with the NMEA 2000 standard for interfacing with the NMEA 2000 network. NMEA 2000 network powered to offer easy installation with no need for a direct connection to the vessels main battery supply. The NGW-1-ISO takes all its power from the NMEA 2000 network connection and contains a clever built-in power isolator to power its serial circuitry without the need of an extra battery source. This creates total isolation between the serial and NMEA 2000 circuitry to completely eliminate the risk of ground loop faults occurring and the resulting damage. Connecting devices together The NMEA 2000 standard The NMEA 2000 system is a low-cost data network operating at 250 kbits/sec utilizing the Controller Area Network (CAN). Multiple devices can be connected together on a single trunk cable to simply and easily share information between themselves. NMEA 2000 uses a shielded cable and a differential signalling scheme, whereby two wires are used to transmit the NMEA data named CAN High and CAN Low. These connections will be labelled as NET HI and NET LO respectively. Power is also supplied through the NMEA 2000 cable named NET Supply and NET Common. These connections will be labelled NET SUP and NET COM respectively on the PCB. Please refer to the Connecting to the NMEA 2000 Network section for an example of these connection methods. Software updates The NGW-1-ISO s built-in firmware is held in flash memory, allowing quick and easy upgrades using either the latest NGW-1-ISO ActiPatch, or alternatively the NMEA 2000 Gateway Configuration Tool running on a PC connected to the NGW-1-ISO. It is our policy to provide these updates free on the Actisense website (www.actisense.com), so that the NMEA 2000 to NMEA 0183 Gateway (NGW-1-ISO) can be further developed over time, and should there be any bugs reported in the firmware, they can be promptly fixed without the unit requiring to come out of commission. Page 5

Connections 1 3 4 2 5 Figure 1 All external connections Figure 1 shows an internal view of the NGW-1-ISO Printed Circuit Board (PCB). 1. NMEA 2000 Interface A five way screw terminal block is supplied for connecting the NMEA 2000 cable. The CAN interface is fully compatible with the NMEA 2000 standard. Actisense supplies a pre-fitted four-core screened cable for the NMEA 2000 connection, fitted with a male micro-fit connector. The colour codes used for this cable are: Wire colour NMEA 2000 Shield / Screen Blue White Black Red SHIELD NET LO NET HI NET COM NET SUP If you need to use your own NMEA 2000 cable, the five way screw terminal block is provided within the NGW-1 to allow easy connection, along with a spare cable gland that should be fitted on to the new cable to help maintain the water protection level. Any such cable is required to conform in full to the NMEA 2000 specification and be no longer than 6 metres (maximum drop length). 2. NMEA 2000 indicator LED This LED flashes when NMEA 2000 data set to be transferred is received by the NGW-1-ISO. It can be clearly seen through the NGW-1-ISO s translucent lid when the case is closed. 3. Serial opto-isolated input. Two screw terminals are provided to connect the serial input. The serial input is of the differential optoisolated type and uses the unique Actisense low current drain circuitry (2 ma @ 2.0 V). 4. Serial ISO-Drive output. Three screw terminals are provided to connect to the serial ISO-Drive output. The serial output comprises of three connections: +, - and Ground (GND). The colour codes used for this cable are: Wire colour NMEA 0183 Shield / Screen SHIELD Blue ISO Out B / - White ISO Out A / + Black Opto In B / - Red Opto In A / + In most installations, this ground (GND) can be left disconnected. It is useful where an RS485 or IEC61162-2 3 terminal type connection is required, or where ground continuity is needed between source and target connections. No damage will be caused by connecting to this GND in error. Always follow the connection diagrams shown in this manual to ensure correct operation. 5. Serial data indicator LED This LED flashes when serial data set to be transferred is received by the NGW-1-ISO. It can be clearly seen through the NGW-1-ISO s translucent lid when the case is closed. To open the NGW-1-ISO, remove the two screws in the base of the unit, then slide off the top of the case. The cable glands need to be slid out from the top of the case in order to access the internal connections. The NGW-1- ISO circuitry will be left attached to the base of the unit and the two supplied cables attached to their connectors. Note: When opening the NGW-1-ISO case, be aware that the circuitry inside is not 100% protected against static electricity. Please ensure that, when opening the case, you use precautions against static damage by only touching the connector block and by holding the unit by its plastic base. In this way, the risks of static damage will be minimised. Page 6

NMEA 2000 to NMEA 0183 Gateway - NGW-1-ISO Connecting to the NMEA 2000 network CAN Network CAN Lo CAN Hi Shield NET COM NET SUP Figure 2 NMEA 2000 connections NMEA 2000 connections The Actisense NGW-1-ISO is designed to be connected to the vessel s NMEA 2000 network using the supplied, pre-fitted Actisense cable. If a different length cable is required, an NMEA 2000 certified cable of the required length (maximum 6 metres) should be connected to the vessel s NMEA 2000 network using a standard NMEA 2000 connector. The standard wiring connection can be seen in Figure 2. Note: 1. Wire colours are for guidance only. The colours given relate to the supplied Actisense cable and the NMEA 2000 standard cable definition. Connecting to an NMEA 0183 device B/- A/+ / / GND TX B/- / GND A/+ / RX Do not connect NMEA Talker NMEA Listener Figure 3 NMEA 0183 connections NMEA 0183 connections The Actisense NGW-1-ISO is designed to be connected to an NMEA 0183 device using the supplied, pre-fitted Actisense cable. If a different cable is required, the cable specification (quality) and length should be considered. The maximum length of such a cable is dependent on the input & output specifications of the NMEA 0183 device and cable quality. The NGW-1-ISO has a very sensitive input and powerful output to help maximise the working cable length. The standard wiring connection can be seen in Figure 3. 1. Wire colours are for guidance only. The colours given relate to the supplied Actisense cable. Page 7

Connecting to an RS232 (PC) port Do not connect TX Pin 3 RX Pin 2 GND Pin 5 Personal Computer ( 9 PIN 'D' RS232 Port) Figure 4 Personal Computer / RS232 port connections RS232 Connections The NGW-1-ISO can be connected to a PC communications (RS232) port using the supplied cable and a connector with the following specification: 1. A minimum of 3-cores are required in a shielded cable. Higher quality cable will naturally yield higher performance / higher Signal-to-Noise Ratio (SNR). Most typical cables have two twisted pairs inside. In this case, use one pair for the TX line and one for the RX line. Use the spare wire in each pair as ground, and connect the cable shield to ground only at the computer end. 2. A D-type female (socket) connector for the PC end of the cable. 3. The OUT +/A of the NGW-1-ISO should be connected to the RX of the computer (standard D-type, pin 2) and the NGT-1-ISO IN +/A should be connected to the TX of the computer (pin 3). 4. Connect the IN -/B and OUT -/B together and connect to the PC s serial port ground (pin 5). Connecting to an RS485 (IEC 61162-2) listening device A/+ B/- GND RS485 Listener Figure 5 RS485 / IEC 61162-2 port connections RS485 Connections The ISO-Drive output of the NGW-1-ISO can be connected to an RS485 Listener that requires differential drive plus a ground connection as shown in figure 5. 1. Wire colours are for guidance only. The colours given relate to the supplied Actisense cable. The standard wiring connection can be seen in Figure 5. Page 8

Specifications NMEA 2000 to NMEA 0183 Gateway - NGW-1-ISO Parameter Conditions Min. Max. Unit Supply Supply voltage 8 35 V Supply current (see note 1) NMEA 2000 CAN Bus line (CAN-H; CAN-L) Transmitter Supply voltage = 12v 26 30 ma Supply voltage = 24v 16 18 ma Recessive bus voltage VTXD = VDD; no load. 2.0 3.0 V Dominant bus voltage CAN-H VTXD = 0.8V 2.75 4.5 V Dominant bus voltage CAN-L VTXD = 0.8V 0.5 2.25 V Recessive differential output voltage VTXD = 2V; no load -500 50 mv Dominant differential output voltage 40Ω < RL < 60Ω 1.5 3.0 V Short circuit output current CAN-H VCAN-H = -5V - -200 ma Short circuit output current CAN-L VCAN-H = -40V, +40V. (see note 2) - 200 ma NMEA 2000 CAN Bus line (CAN-H; CAN-L) Receiver CAN-H, CAN-L common-mode input resistance 5 50 KΩ Differential input resistance 20 100 KΩ Opto-isolated Input Input voltage tolerance Continuous operation -15 +15 V Short term operation (< 1 sec) -35 +35 V Differential input voltage Required level for data to be detected 1.8 - V Input current - 2 ma Input to Ground Baud rate Configurable Baud rate 4800 230400 bps ISO-Drive Output Output current RS485 / RS422 / RS232 compatible - 20 ma Differential output voltage 100 ohm load 2.1 - V Output to Ground Full Galvanic isolation protection - 1500 V Baud rate Configurable Baud rate 4800 230400 bps General Ambient operating temperature -20 +70 C Table 2 NGW-1-ISO specifications All specifications are taken with reference to an ambient temperature (T A ) of +25 C. Note: 1. Current consumption measured under no-load conditions Page 9

Troubleshooting guide This guide will concentrate on all relevant troubleshooting issues above simple cable connection faults. Therefore, the cables between the NGW-1-ISO hardware and any other devices should be checked as a matter of course, before continuing with this guide. Status LEDs The NGW-1-ISO hardware has two bright LEDs that can be seen through the case to indicate when data is received from either the NMEA 0183 device or NMEA 2000 network connection. It is an important point to note that these two LEDs can only show when their respective data is RECEIVED; it is not possible to show both transmit and receive simultaneously on a single colour LED. These LEDs can be used to debug potential problems. If both an NMEA 0183 talker and a listener are connected, it is possible to analyse which is working by disconnecting one of them or by stopping the computer from sending data. Sequence Description NMEA 2000 LED does not flash when the data is received from the NMEA 2000 network Check that the NGW-1-ISO is connected to the NMEA 2000 network, that the NMEA 2000 network is operational, and that the required PGN messages are selected for transfer by using the NGW Configuration Tool. Serial LED does not flash when Serial data is being received Check that the NGW-1-ISO is connected correctly to the NMEA 0183 device, that the same Baud rate has been set on both devices, and that the required messages are selected to be transferred by using the NGW Configuration Tool. Both LEDs flash together, once every 10 seconds Indicates that the NGW-1-ISO is powered but no data is received from either connection. If data should be being transferred through then check that the required PGN messages are selected by using the NGW Configuration Tool. If the error persists, please contact Actisense support to help trace the issue before considering the return of the product. If Actisense support concludes that the NGW-1-ISO unit should be returned to Actisense (refer to the Company Information section), a Returns Number will be issued by the support engineer. The Returns Number must be clearly visible on both the external packaging and any documentation returned with the product. Any returns sent without a Returns Number will incur a delay in being processed. Table 3 Diagnostic LED Page 10

Product order codes NMEA 2000 to NMEA 0183 Gateway - NGW-1-ISO NGW-1-ISO NGW-1-USB NMEA 2000 Serial Interface with ISO-Drive Standard version required to connect the NMEA 2000 network to an NMEA 0183 device or computer serial port NMEA 2000 USB Interface Special version required to connect the NMEA 2000 network to the USB port of a computer running NMEA 0183 compatible software Company Information Active Research Limited Unit 5 Wessex Trade Centre Ringwood Road Poole Dorset. UK BH12 3PF Telephone: 01202 746682 (International : +44 1202 746682) Fax: 01202 746683 (International : +44 1202 746683) Actisense on the Web: For advice, support and product details E-mail: Website: support@actisense.com www.actisense.com Actisense is a registered trademark of Active Research Limited. Page 11

The Actisense NGW-1-ISO allows an NMEA 0183 device to talk and listen to NMEA 2000 devices on an NMEA 2000 network. By translating NMEA 2000 data into the NMEA 0183 equivalent (and viceversa), the NGW-1-ISO enables information to be shared between NMEA 0183 devices and any instrument on the NMEA 2000 network. Benefits All NMEA 2000 instruments on the network can see translated NMEA 0183 data sent from NMEA 0183 device PC software can receive translated data from any NMEA 2000 instrument Electrical isolation separates the two networks, protecting against ground loop faults. This creates a protected computer and a safe installation The NGW-1 device is compatible with all NMEA 0183 devices (both singleended and standard differential types) The isolating ISO-Drive connection of the NGW-1-ISO makes it one of the best and safest ways to connect your NMEA 0183 device to an NMEA 2000 network. Just connect and relax, knowing that Actisense has it secured. Specifications NMEA 2000 Connection NMEA 2000 network is opto-isolated from the serial connection to offer 1500 volts of protection NMEA 2000 current draw 30 ma typical Terminal block available for user cable connection Cable length 1.5 metres Opto & ISO-Drive Connection Exceeds all NMEA 0183 input/output specifications Compatible with RS422 (NMEA), RS232 & RS485 Baud rates 4800 to 230400 Cable length 1.5 metres System Requirements Supported OS s: Windows (2000, XP and Vista). Check website for other versions No drivers required Environmental Recommended operating temperature: -20 C to +70 C Splash proof plastic casing provided with sealing cable glands certified to IP54 Stainless steel case screws Humidity: 0-80% RH Guarantee 3 years return to base Certifications CE (EN60945) Tested and certified NMEA 2000 compliant Active Research Limited, Unit 5 Wessex Trade Centre, Ringwood Road, Poole, Dorset, UK, BH12 3PF Telephone: +44 (0)1202 746682 Fax: +44 (0)1202 746683 Actisense on the Web: For advice, support and product details E-mail: support@actisense.com Website: www.actisense.com Actisense is a registered trademark of Active Research Limited.