R-Gaïa Free-Cooling and Meteorological conditions

Similar documents
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Recapture Capacity for Existing. and Airflow Optimization

GETTING STARTED WITH IN-WALL RELAY SWITCH

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

RO 051 S-DIAS Relay Output Module

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

A separate CRAC Unit plant zone was created between the external façade and the technical space.

ISE 021 S-DIAS Interface Module RS232 / RS485

Planning a Green Datacenter

SI 021 S-DIAS SSI Interface Module

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

ICA 012 S-DIAS Interface Module CAN

ControlLogix Redundant Power Supply Chassis Adapter Module

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

Welcome Association of Energy Engineers to the Microsoft Technology Center

Retro-Commissioning Report

MSYS 4480 AC Systems Winter 2015

MEASURE MONITOR UNDERSTAND

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Introducing the Heat Wheel to the Data Center

1769 Compact I/O Communication Bus Expansion Cables

Data Center Energy and Cost Saving Evaluation

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

IPv6 Protocol (RFC 2460 DS)

Data Center Energy Savings By the numbers

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

ASHRAE IRELAND HVAC FOR DATA CENTRES. Michael Geraghty Building Services Engineer (DipEng) Company owner and managing director

Air Containment Design Choices and Considerations

Aquaflair. BREC/F and BCEC/F kw

Power and Cooling for Ultra-High Density Racks and Blade Servers

DK UL. Ref. Certif. No. Date: Signature:

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Switching Power Supply for Building In

About Transferring License Rights for. PL7 V4.5 and Unity Pro V2.3 SP1 Software

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2

Environmental Data Center Management and Monitoring

HVAC DESIGN REQUIREMENTS FOR DATA CENTERS

Art and Science of Building NUS Data Centres

Some advises for insulating a new. l isolation d un nouveau laboratoire. Arusha, January 2012

C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs

LVB-2 INSTRUCTION SHEET. Leakage Current Verification Box

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

WASP Wireless Acceleration Sensor Puck USER MANUAL

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2

INSIDE THE PROTOTYPE BODENTYPE DATA CENTER: OPENSOURCE MONITORING OF OPENSOURCE HARDWARE

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Running Your Data Center Under Ideal Temperature Conditions

Evolution of Facebook s data center design. Veerendra Mulay, PhD Strategic Engineering and Development

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

VLANs. Commutation LAN et Wireless Chapitre 3

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

2201 Rack Chassis User Manual

VI 021 S-DIAS VARAN Control Module

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Thermal management. Thermal management

IT Air Conditioning Units

Why would you want to use outdoor air for data center cooling?

Google s Green Data Centers: Network POP Case Study

Industry leading low energy evaporative fresh air cooling.

WaterStopper User Instruction Setup and Troubleshooting guide

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Sun Fire V125 Server Getting Started Guide

LM910 Bluetooth 4.0 (Classic + LE) HCI Compact USB SMT Module Dual-Mode with 110m Estimated Max. Distance with Integrated Antenna

FREEING HPC FROM THE DATACENTRE

Internet Scale Infrastructure Innovation

ENCLOSURE HEAT DISSIPATION

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Green IT and Green DC

Trading TCO for PUE? A Romonet White Paper: Part I

ASHRAE Data Center Standards: An Overview

RF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink

ECOBAY: Closed loop water cooled server cabinet for data centers

1. Getting to know the gimbal

Efficiency of Data Center cooling

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

User Manual 318BT. Phantom Powered Bluetooth Audio Receiver

HIGH DENSITY RACK COOLING CHOICES

APC APPLICATION NOTE #114

Rack cooling solutions for high density racks management, from 10 to 75 kw

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

brightsolid Data Hall 1 Keysource Technical Specifications

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends

Implications of Current Thermal Guidelines

WIRELESS ENVIRONMENTAL MONITORS

Transcription:

R-Gaïa Free-Cooling and Meteorological conditions Jean-Yves Clément December 2012 Copyright International Business Machines Corporation 2012. All rights reserved. IBM and its logo are trademarks of IBM Corporation. This document may not be reproduced in whole or in part without the prior written permission of IBM. Please consider the environment before printing this document

Agenda Free-cooling design choices Weather analysis Operation example IT specifications ASHRAE 2011 2

Agenda Free-cooling design choices Weather analysis Operation example IT specifications ASHRAE 2011 3

Light structure Real Estate and Site Operations 4

Heavy structure Real Estate and Site Operations 5

Heavy structure principal 6

Light structure principal 7

Cold air aisle is more efficient: Heat exchange is better shared with all CRAC s Less expensive (non return air plenum) Heat exchange with building structure are optimized T ext = 15 C and below Delta T Cold aisle = 15 C Delta T Hot aisle = 5 C Favorable to Cold aisle T ext = 25 C Delta T Cold aisle = 5 C Delta T Hot aisle = - 5 C Favorable to Cold aisle T ext = 35 C and above Delta T Cold aisle = - 5 C Delta T Hot aisle = - 15 C Favorable to Cold aisle Cold aisle Hot aisle 8

Humidification: steam time is over! 9

Humidification: steam time is over! Cold vapor generation High pressure Centrifugation Compressed air Piezo 10

Humidification: steam time is over! 11

Agenda Free-cooling design choices Weather analysis Operation example IT specifications ASHRAE 2011 12

Montpellier Airport Temperatures 2008 DATE C Mean 00h-06h C Mean 07h-18h C Mean 19h-23h 35 30 25 20 15 10 5 0 janv.-00 févr.-00 avr.-00 mai-00 juil.-00 sept.-00 oct.-00 déc.-00 févr.-01-5 13

Grenoble Temperatures 2007 14

Agenda Free-cooling design choices Weather analysis Operation example IT specifications ASHRAE 2011 15

Air specification to apply to IT : ASHRAE 2008 was an improvement for air containment efficiency: Temperature of cold air (25 C) blown under the raised floor is a limiting factor during summer. 5,5 C dew point is too strict compared with IT specification Proposed solution Extent humidity working range to IT specifications Control hygrometry in DC and adjust blowing temperature with AMU 16

ASHRAE IT 2008 ASHRAE 2008 Allowable (Class 1) ASHRAE 2008 Recommended 17

Weather example 18

Weather example: too hot during 2h30 19

Weather example: too dry during 23h30! 20

12,5 C and 60% RH is too dry for ASHRAE! 21

Agenda Free-cooling design choices Weather analysis Operation example IT specifications ASHRAE 2011 22

IT Requirements X3550 Supported environment: Air temperature: Server on: 10 to 35 C (50.0 to 95.0 F); altitude: 0 to 914.4 m (3,000 ft). Humidity: Server on: 20 to 80%, maximum dew point 21 C, maximum rate of change 5 C/h 23

IT Requirements ZSeries S/390 z196 24

IT Requirements Environmental and shipping specifications for tape cartridges 25

IT Requirements: worst case hygrometry 26

Weather limit for air blowing at T=21 c and Hr=20% in DC 27

Water weight evolution during October 8 th 28

November 6 th to 11 th humid period outside air 29

ASHRAE Real Estate and Site Operations Free-cooling design choices Weather analysis Operation example IT specifications ASHRAE 2011 30

ASHRAE 2011 Real Estate and Site Operations 31

ASHRAE 2011 Real Estate and Site Operations 32

ASHRAE 2011 Real Estate and Site Operations 33

ASHRAE IT Equipment Environment Corrosion Data corruption Reduced life Cycle Electrostatic discharge 34

ASHRAE humidity limit vs IT specification la spécification de l'air soufflé dans les data centres doit être conforme au cadre pointillé vert de la page 29 de la présentation jointe, c'est à dire t=18 C à 27 C et hr= 80% à 20%. Ceci implique que l'air extérieur présentant des températures même très inférieurs à 15 C doit être utilisé du moment que son poids d eau permet d être en spécification une fois réchauffé dans le data center. Plus largement l efficacité du FreeCooling sera améliorée si l AMU (Air Mixing Unit) permettre de balayer toute la plage de température autorisée de manière à utiliser au mieux les caractéristiques de l air extérieur. De ce fait les jours ou l air extérieur est froid et sec, une température de soufflage de 15 C donnera le meilleur résultat. La température extérieure remonte en cour de journée de 8 C à 10 C en 8heurs. Ceci respecte les 5 C/h de variation demandées dans les spécifications des équipements IT. 35

ASHRAE humidity limit vs IT specification Only solution to use Free-Cooling in winter No risk for IT No energy lost with humidification system Reduce condensation risk 36