Smart Touch Thermostat Colour Touchscreen Thermostat

Similar documents
Italian, Japanese, French, Poland, simplified Chinese, traditional Chinese, Holland, Portuguese, Vietnamese, Arabic, Korean)

Model: Available in : Sapphire Black and Glacier White

Model: Available in : Sapphire Black and Glacier White

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT

Digital Room Thermostat for Underfloor Heating Applications

Model: Touchpad (TFT) Model: TFT

ERT50T Triac Noiseless Digital Room Thermostat for Underfloor Heating Applications

Quick Start Installation and User Manual

Glass sensors 35. Supplementary products 39

7-day room temperature controller

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Master room unit for RRV controllers

Room Temperature Controller

Installation Guide DEVIlink CC Central Controller

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Semi flush-mounted room temperature controllers with LCD

Programmable(5+1+1)Touch Screen LCD Wired Thermostat. General. Features. Operating Algorithm

SOLARIMMERSION IV Advanced Installation Manual v1.9

Semi flush-mounted room temperature controllers with LCD

Weekday / weekend room temperature controller

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Model: TM-1 / TM1-N. 1 Time Clock Series

Orbital smart Tunable Downlight

Room Temperature Controllers

7-day room temperature controller

Integrating and configuring Dynalite lighting and heating systems with SystemNet software

Programmable(5+1+1)Touch Screen LCD Wireless Thermostat. General. Features. Operating Algorithm

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Niloé. Getting it just right

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

SRT-P50 Series Programmable Touchscreen Thermostats

Room Temperature Controller

Weekday / weekend room temperature controller

KNX temperature control panel

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Installation Guide. OB-1101 idim Orbit. 1. Features and Connections. Default Settings. Connections MANUAL SWITCH DALI 1 DALI 2 L2 L1

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS

Model: EP210. Dual channel programmable controller. Installation Manual

Select 107 XLS User Instructions

3% VOLTAGE DROP. Installation Instructions for 100 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

VT8600 Series Installation Guide. Rooftop Unit, Heat Pump and Indoor Air Quality Controller

7 Day Programmable Room Thermostat

Electrical Demand Specification (Reference SOP: )

Functions. Technical Data. Wireless Room Thermostat

7 Day Digital Programmer 2 Channel Surface Mount

TECHNICAL DATA. V-PIX Quad Bar. Product code CL-VPIX-4-40 Light colour Full spectrum 8 / 480 (see above)

ProMinder Standard Heating System Installation Instructions

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

MH9-CO2-WA/WD. Introduction. Specification

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

7 Day Digital Programmer 1 Channel Surface Mount

DPL4000 Portable Low Range Dew Point Analyzer

climote HUB Installation Guide

Product documentation

Semi Flush-mount Room Temperature Controllers with LCD

InBin-P Pressure switches from 5 Pa Pa

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

The world s smartest heating system. Programmable Touch Screen Thermostat

Product and Function Description

Operating instructions Evaluation system for flow sensors VS / / 2013

Table of Contents. Model: -hw. -hw. Series. Available in : Sapphire Black and Glacier White. Product Image. 16 Table of Contents

Temperature controller Ducted systems

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

PS/IO Circuit Board Retrofit

CDD4 Series Room CO2 Transmitter Installation Instructions

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

OPERATING INSTRUCTION

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

S-Series Digital Thermostat

SRT-50 Slimline Touchscreen Thermostats

Digital Room Thermostat

Weathersafe Vision. Installation & Operating Instructions

Room controller STRA-17

Content. Product Description

KM692K KELOX BUS room thermostat - Digital

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Model HM-535 Power Supply Installation and Service Instructions

RDF Series Room Temperature Controllers

Operating instructions. Switching amplifier DN0210 DN / / 2015

Temperature Switches

Overview - Danfoss Link and Connect software versions

MICROLINE 320/390FB User Manual (English)

S82S (3/7.5-W Models)

Communicative heating controller, Ethernet

Sollatek SVS Range Voltage Stabilisers User Manual

ADVANCED REMOTE CONTROL

RТTH DUAL ROOM SWITCH

Temperature Controller

Transcription:

OBSMART Smart Touch Thermostat Colour Touchscreen Thermostat

INTRODUCTION Orbry Smart Touch Thermostat The Orbry Smart Touch Thermostat is a digital thermostat, which is designed for electric underfloor heating systems with a maximum load of up to 16A (3600W). The Orbry Smart Touch features a 4.3 colour touchscreen display and four (4) languages. IMPORTANT SAFETY REGULATIONS ALL WIRING MUST CONFORM TO IEE 17TH EDITION PART P REGULATIONS. THIS PRODUCT IS RATED IP30. The Orbry Smart Touch Thermostat is IP30 rated and suitable for safe installation in bathrooms. It is not suitable for use in special locations, such as wet zones. All electrical circuits in bathrooms must be protected by a 30mA RCD. The instructions we supply include as much information as possible to ensure that all installations comply with current electrical regulations. Please call our customer support line, if in any doubt, on 0845 208 0221. DO Install a conduit for your sensor probe before thermostat installation. DO NOT Ignore electrical regulations. Install this thermostat in a wet zone.

INSTALLING THE ORBRY SMART TOUCH Before you begin The sensor conduit and deep back box must be fi tted before installation of the actual thermostat can begin. Feed the sensor probe provided down through the sensor conduit into a representive area of the floor. For technical advice or help with any queries, please call our customer support team on 0845 208 0221 or visit www.orbry.com/orbry-downloads. Installation Step 1: Release the face plate Place the unit face down on a hard surface and push the three (3) clips located on the bottom of the Orbry Smart Touch in with a screwdriver to release the face plate. Step 2: Disconnect ribbon cable & remove face plate Once the face plate has been gently opened disconnect the ribbon cable to release the face plate.

WIRING THE ORBRY SMART TOUCH Wire and replace the face plate Loosen the tension screws to allow the wires to be inserted and fixed. Position the cables as shown in the wiring diagram and ensure each screw is tightened correctly. 7 6 5 4 3 2 1 Sensor L 3600W/16A 230V/AC Ensure system is correctly earthed. N N L Fix the Orbry Smart Touch Thermostat to the wall Align the Orbry Smart Touch with your back box and fix in place with the screws provided. Now, reconnect the ribbon connections and reseat the face plate (bottom edge first). Ensure the Orbry Smart Touch is securely fixed before continuing. 2 1 3 4 5 2 1. Faceplate 4. Back plate 2. Provided screws 5. Back box 3. Ribbon connectors

PROGRAMMING THE ORBRY SMART TOUCH Orbry Smart Touch Thermostat Interface 10 9 8 7 6 11 12 13 14 ROOM 5 4 3 2 1 1. On / Off button 8. Heating icon 2. Mode button 9. Weekday icon 3. Menu button 10. Ambient temperature 4. Down button 11. Clock icon 5. Up button 12. Temperature icon 6. Mode icon 7. Set temperature 13. Floor temperature 14. Mode icon area

PROGRAMMING THE ORBRY SMART TOUCH Preset Modes Manually switch between these preset temperature modes to allow flexibility outside of your heating schedule. Settings Economy mode Preset a low energy saving temperature 18 C for economical comfort and energy savings. Comfort mode Preset a comfort temperature (e.g. 25 C) and enjoy warmth outside of your heating schedule. Program mode Your own customisable heating schedule. Holiday mode Automatically maintain a preset low energy saving temperature (e.g. 8 C) while you re away. Boost mode Set a high temperature (e.g. 27 C) and quickly switch to this high temperature on demand. Language selection Press to choose one of four (4) languages. Preset temperatures Use to define pre-set temperatures. Program review Use to check your 5+1+1 day schedule. Date & time button Use to set the correct weekday and time. Protection temperatures Use to define minimum and maximum temperatures.

PROGRAMMING THE ORBRY SMART TOUCH Schedule settings Press the MENU Button, then press to review your weekly schedule. Select Mon Fri, Sat or Sun to edit your custom heating schedule. Example: If you would like to edit your Sunday schedule, then press the Sun column to enter the edit page (as shown). Every setting can be edited using the or buttons. RETURN RETURN 1. 2. In the Sun column, there are six (6) periods. You can press the or buttons to choose the period you are going to change. The button will display beside the period selected. Next, you can set the start time and desired temperature by pressing the and buttons. 3. Finally, press APPLY to save your new schedule.

PROGRAMMING THE ORBRY SMART TOUCH Edit date & time Press the MENU button, then the button to edit the date and time with the and buttons. Press APPLY to save the changes. RETURN Preset temperature mode Press the MENU button, then the button to select a mode. Now, edit that mode setting s temperature using the and buttons. Press APPLY to save the changes. Language select Press the MENU button, then the button to enter the language page. Choose the desired language and press APPLY to save the changes. RETURN RETURN

PROGRAMMING THE ORBRY SMART TOUCH Protection settings Press the MENU then the button to enter the protection settings page. You can set an over protection temperature and a low protection temperature using the and buttons. Press APPLY to save the changes. RETURN High protection: This is an over heat protection setting designed to monitor the floor temperature and set a limit defined by you. If the system reaches the set protection temperature, the system will shut off automatically. Low protection: This is a frost protection mode designed to function when the Orbry Smart Touch is switched off. If the ambient temperature reaches the set protection temperature, the system will automatically switch on to maintain a minimum temperature. Please note: The upper limit should be no higher than 28 C to conform with European regulations.

PROGRAMMING THE ORBRY SMART TOUCH Parameter settings To access the parameter settings, switch the Orbry Smart Touch OFF and immediately press the button for two (2) seconds. You can set the desired values by pressing << OR >>. Go to the other pages by pressing PRE or NEXT. The upper limit should not exceed 28 C. Menu Description Range 01 Temperature Offset -8 C ~ 8 C 02 Dead Zone 0 C ~ 3 C 03 Set Point Maximum 5 C ~ 35 C 04 Set Point Minimum 5 C ~ 35 C 05 NTC Select (Ambient I, Floor E) I only, E only, I & E, I or E 06 Low Protection Maximum 5 C ~ 10 C 07 Low Protection Minimum 5 C ~ 10 C 08 High Protection Maximum 5 C ~ 90 C 09 High Protection Minimum 5 C ~ 90 C 10 Backlight off Time after Operation 3s ~ 180s 11 Min. Backlight Brightness of Standby Status 1% ~ 100% 12 Relay Delay Time 0s ~ 250s 13 Relay Output Normal (NO); Inverted (NC) 14 Restore << or >>

Sensor TECHNICAL SPECIFICATIONS Dimensions 60mm 19mm 31mm 7 6 5 4 3 2 1 L N 3600W/16A N 230V/AC L 50mm 52mm 94mm 4.3 87mm 130mm

Product features 4.3 inch colour touchscreen display Control electric underfloor heating systems up to 16A (3600W) Adjustable comfort mode, economy mode, boost mode, holiday mode, and program mode control 5+1+1 days, 6 event programmable schedule Ambient and/or floor sensors Four languages: English, French, German, and Dutch Clock and date display Temperature calibration Overheat and frost protection modes Single gang extra deep back box Voltage Maximum load Temperature range Ambient Sensor Accuracy Warranty IP Rating Width Height Depth 230V 50/60Hz 16A (3600W) 5 ~ 35 O C 0 ~ 50 O C NTC 10k 10kΩ at 25 O C ± 0.5 O C 3 years IP30 130mm 87mm 50mm (31mm in wall) www.orbry.com info@orbry.com 0845 208 0221