ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

Similar documents
Hand-held Fully Featured Eddy Current Flaw Detector ET NDE

TRULY AFFORDABLE EDDY CURRENT

Electromagnetic Wire Rope Inspection System LMA-TEST (USB) Specification Sheets

Ultrasonic Bolting Equipment, Transducers & Accessories - Price List Date: 02/01/18

FG-7000L Digital Force Gauge Operation Manual

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

FG-3000R Digital Force Gauge Operation Manual

FG-7000 Digital Force Gauge Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

Application Series Page. Electronic Indicators 900, 901, 903 E.2 E.3. Dial Indicators 450, 451, 458 E.4 E.5. Transducer Probes 971 E.

-Direct.com FG-3000 Digital Force Gauge Operation Manual

MIZ-22 Eddy Current Tester

FG-3000 Digital Force Gauge Operation Manual

1519L Multifunction 15-inch Desktop Touchmonitor

TTC Series Torque Tool Tester Operation Manual

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

Thickness Gauge Transducers & Accessories - Price List Date: 01/01/18

High-Performance. Eddy Current Flaw Detector NORTEC 600

High-Performance. Eddy Current Flaw Detector NORTEC 600

Video Borescope Inspection Camera

5.6" Multi-function Monitor

Introduction. Chapter 2

O T Rotating Laser Target System.

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

VERIMET Model EDDY CURRENT INSTRUMENT OPERATION MANUAL Version 2.2 March Portable Eddy Current Tester

DT-900 Techstrobe Operation Manual

Bearing (Shock Pulse) Condition Analyzer -110

DCT7088 Portable Digital Correlation Transit Time Flowmeter

AGATE TECHNOLOGY AT-2040

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

Rohmann. Rohmann Update. Eddy Current Instruments and Systems. Elotest M2. Contents. Issue 2, June 2003

SMALL SIZE. BIG VALUE. TOPAZ 16 BEST IN CLASS FULLY INTEGRATED 16 CHANNEL PHASED ARRAY UT DEVICE.

OPERATION MANUAL DAKOTA ULTRASONICS. Data Logging Thickness Gauge

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

MPT-250C Wire Crimp Pull Tester

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Coating Thickness Tester

Portable vibration calibrator Model 28959G

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

OX 5022-CK OX 5042-CK

NHT-310. Broadband EM Field Meter: DC 40 GHz. HAVSCo LTD. Key Features:

Data Sheet Version 1.0

S-650 Coupling Alignment System

SL2400 Compact Monitor

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

iprox Sensing Solutions iprox Analog iprox Standard iprox Clone iprox Accessories iprox. The world s most versatile proximity sensor.

NORTEC 600 Eddy Current Flaw Detector Getting Started Guide

Quattro Flow. Air Velocity Analyzers. Mobile Multipoint Evaluation CAMBRIDGE ACCUSENSE, INC.

NOMAD 4000 Marking System

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

SHIMPO INSTRUMENTS. ST-320BL LED Stroboscope Array Operation Manual

Nexio. NEXIO Co.,Ltd. NIO150SA Desktop Touch Monitor. LCD Monitor User Guide.

User's Guide. Vibration Meter and Laser Combination Tachometer Model

GE Inspection Technologies. The NEW Phasec 3 Series. Eddy Current Flaw Detectors - A Common Platform

MANUAL TV-100 TV-100

The Most Advanced Digital Variable Impedance Transducer for Noncontact Linear Position / Displacement Sensing

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

SIGMATEST Operating Instructions

LIVE C.T. ADMITTANCE TESTER 505B DATASHEET REDPHASE INSTRUMENTS

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

Level-Lance Model 5400A

RIGS STACKS ROCKS ROLLS

ELECTROSTATIC FIELDMETER

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Video Borescope Inspection Camera

G90 Series Handheld Hall Gaussmeter

innovative technology to keep you a step ahead In-Home Leakage Evaluation System

Strain Gauge Measurement by Applying Displacement using Strain Indicator

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

Trimble R10 MODEL 2 GNSS SYSTEM. C WARNING For safety information, refer to the Safety Information FIVE SIMPLE STEPS TO GET STARTED

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

More Precision. eddyncdt // Eddy current sensors for displacement and position

TOXALERT MODEL AIR 2000

Model SR755i Wheelchair Scale Operating and Service Manual - S/N Part No. MAN755i_ Page 1 of 18. Model SR755i.

TECHNICAL DATASHEET #TDAX023240

Operating Instructions STX Series Digital Strap Tension Meter

Hand-held thermometer Model CTH7000

CHECK LINE. Flaw Detectors, Accessories & Probes - Price List Date: 10/01/11

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

Ultrasonic Flaw Detector CMSUFD70

Precision thermometer Model CTR5000

ELECTROSTATIC FIELDMETER

91370 SL2600 Compact Monitor

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

PDW30 Point-To-Point Wireless Bridge

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

Instruction Manual Ultrasonic Thickness gauge DC3020

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Flaw Detectors, Accessories & Probes - Price List Date: 01/01/18

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Transcription:

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT EQUIPMENT SPECIFICATION ES-110-1 - 1.0 Description 1.1 The Model ED-1100 is a microprocessor based variable frequency eddy current instrument, with a liquid crystal display readout, that detects homogeneity and conductivity changes in magnetic and nonmagnetic materials instantaneously. The instrument is battery operated, light weight, and can be used in the manufacturing shop, in the field, and in the laboratory with a wide selection of probes and coils common to standard Centurion NDT instruments (ED-400, ED-510XL, ED-520/530 series, ED-800, and ED-810). 1.2 The instrument will detect surface and subsurface defects in both magnetic and nonmagnetic materials. Defects cause voltage variations that are amplified and displayed on the LCD in the storage or nonstorage mode. This readout provides maximum information on eddy current behavior within the material being tested in terms of phase and amplitude simultaneously. As a matter of convention, liftoff is displayed as the horizontal line on the LCD and the crack indication is an upward or downward slanted line that meets the horizontal at the right extremity of the trace. The severity of the defect is represented by how far the slanted line deflects above or below the horizontal. The phase relationship is the angle between these two lines. 1.3 The ED-1100 will sort classes of materials according to hardness alloy, carbon content, tensile strength, and grain structure. Also, it will measure coating thickness, sheet thickness and measure relative conductivity of critical materials. 2.0 Mechanical and Construction 2.1 The instrument consists of microprocessor based circuitry, a back lit liquid crystal display, and rechargeable battery pack housed in an aluminum case. 2.2 Dimensions: 6.0 (15.2 cm)w x 12.0 (30.4 cm) L and 6.0 (15.2 cm)d with cover closed. 2.3 Weight: 7.5 lbs (3.4 kg)

EQUIPMENT SPECIFICATION ES-110-2 - 2.4 The instrument will operate within the temperature range of 0 o F to 120 o F, at 85% relative humidity. 2.5 The front panel probe connector is a six pin LEMO connector. The unit comes with a probe cable, 6-pin LEMO to dual Microdot, and an adapter, 6-pin LEMO to dual BNC. Adapters are available to accommodate other connector styles. 2.6 The bezel surrounding the LCD may be removed, thus allowing replacement of the scratch shield in front on the LCD and cleaning when necessary. 3.0 Electrical and Performance 3.1 The instrument is powered from an integral rechargeable nickel-cadmium battery, or from the power line (110/60/1 or 220/50-60/1) through the charger while the battery is being charged. The power consumption is 7.5 watts. 3.2 Battery life per charge is approximately 12 hours; with the backlight lit this drops to about 6 hours. Recharge time is approximately 14 hours. 3.3 The instrument has a variable frequency range from 100 Hz to 6.0 MHz. It operates with two probes, a test probe and a reference probe. The reference probe serves as an arm in the eddy current bridge to facilitate balancing. Any of the standard Centurion NDT probes from our current instrument line (ED-520 series, ED-530 series, ED-800 and ED-810) may be used. In cases where the probe connector does not match the ED-1100 front panel connector, adapters can be obtained. 3.4 The liquid crystal display (LCD) of the ED-1100 is a storage monitor that shows a flying dot display featuring random access memory with storage locations allocated to the LCD. As such, the instantaneous movement of the dot may be viewed on the display without storage or the dot movement may be stored on the display. When a suitable pattern, representing the limits of a given test, has been established and stored, the instrument can be switched back to the instantaneous mode. As the test is being made, the stored information remains on the display and the instantaneous flying dot can be superimposed on the LCD for matching the known to the unknown. ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

EQUIPMENT SPECIFICATION ES-110-3 - 4.0 Operation 4.1 The FREQUENCY keypad is used for establishing a suitable test frequency from 100 Hz to 6 MHz read on the LCD in hertz and special functions as described below. 4.2 The Probe DRIVE controls the power to the probe. As the probe drive is increased and the amplifiers go into saturation, the OVERLOAD indication will illuminate on the LCD. For optimum performance, the probe drive should then be decreased until the OVERLOAD indication goes out. 4.3 The GAIN control varies the gain of the instrument over a range of 100:1. 4.4 The PHASE control allows rotation of the display from 0 o to 360 o. 4.5 The EXPAND pushbutton amplifies the signal in the Y axis by 3 times. 4.6 The DOT POSITION controls adjust the position of the dot on the display in the all modes of operation. 4.7 The CHARGE indicator lights when the battery pack is receiving current from the battery charger. The instrument must be off for the battery to receive maximum charge in shortest time. 4.8 The POWER pushbutton is used to turn the unit on and off. The embedded LED lights to indicate that power is being supplied. 4.9 The AUTO push-button toggles between AUTO-NULL and STD-NULL as read on the LCD. In AUTO-NULL, the dot is set by the dot position controls and will return to that location when the bridge is balanced. In STD-NULL, the dot is set by the dot position controls, but will return only when the NULL push-button is depressed. The null point can be located anywhere on the LCD using the DOT POSITION controls. This new location now becomes the zero point. 4.10 The NULL pushbutton is used when in the STD-NULL mode to balance the bridge. The dot will be observed returning to the position selected by the dot position controls.

EQUIPMENT SPECIFICATION ES-110-4 - 4.11 The ERASE pushbutton will remove the stored signals on the LCD. 4.12 The STORE pushbutton toggles between STORE, NON-STORE, and TIME BASE. In the STORE mode, the eddy current signals will be saved on the LCD until the ERASE pushbutton is pushed. In the NON-STORE mode, no signal is saved on the LCD. The TIME BASE mode is represented as a signal that is swept across the display from left to right. A flaw signal will be represented by a vertical indication. 4.13 The B LITE push-button turns the LCD backlight on and off. 4.14 The ACCESSORY connector is available to access analog signals that would be required for a strip chart recorder, reading the horizontal or vertical deflection of the dot, audio or threshold gate, etc. 5.0 Order Reference 5.1 Model ED-1100 Portable Crack Detection and Sorting Instrument, P/N 225340 in an aluminum enclosure with handle and including: Probe Cable, 6-pin LEMO to dual Microdot Adapter, 6-pin LEMO to dual BNC Power Supply/ Battery Charger (must specify 110V or 220V) Operating Manual 5.2 Standard Accessories 5.2.1 Power Supply/Battery Charger, P/N 520104. Fits into top cover and permits operation of instrument on 110VAC, 50/60 hertz, single phase line current. 5.2.2 Power Supply/Battery Charger, P/N 520127. Permits operation of instrument on 220VAC, 50/60 hertz, single phase. 5.2.3 Rechargeable Nickel-Cadmium Battery Pack, P/N 225351. 5.2.4 Probe Cable, P/N 225364. Six pin LEMO connector to dual Microdot cables, 72 inches long.

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT EQUIPMENT SPECIFICATION ES-110-5 - 5.3 Addendum Accessories 5.3.1 Model ED-1100 Starter Kit, P/N 225383 includes: 1 each P/N 226020, Titan Series Probe Cable 1 each P/N 226030, Titan Series Pencil Probe, 6.5 long angled 2 each P/N 207067, Medium frequency surface probe, 5/16 diameter 2 each P/N 213263, Low frequency corrosion probe, 9mm diameter 1 each P/N 225389, Multi-functional Test Block 5.3.2 Model TH-1100 Audio/Threshold Gate, P/N 225390 5.3.3 Model HS-50 Bolt Hole Scanner, P/N 222650 5.3.4 Single Channel Strip Chart Recorder, P/N 519345 5.3.5 Aluminum Test Block with single slot.015 deep, P/N 205156 5.3.6 Aluminum Test Block with three slots,.008,.020, and.040 deep, P/N 207066 5.3.7 Steel Test Block with three slots,.008,.020, and.040 deep, P/N 220004 5.3.8 Balancing Load, medium frequency, BNC connector, P/N 209730 5.3.9 Balancing Load, high frequency, BNC connector, P/N 209735 5.3.10 Consult the probe catalog for the many standard probes and coils available for use with the ED-1100. The ED-1100 design requires a dual coil sensor arrangement for proper instrument operation. If a single probe is required, see the Titan Series Probes, they are a dual coil probe series. Consult factory for furher information. EQUIPMENT SPECIFICATION ES-110

- 6-6.0 References 6.1 Instruction Manual, Form No. 25001 6.2 ES-111 for TH-110 Audio/Threshold Gate 6.3 ES-103 for HS-50 Bolt Hole Scanner 6.4 Price Pages EC-75 Prices available on price list January 2009