Datalogging Hot Wire CFM Anemometer

Similar documents
Datalogging Conductivity/ TDS Meter. Instruction Manual

Anemometer SD Card Datalogger. Instruction Manual

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

Light Meter with Bar Graph

Torque Meter. Instruction Manual

RH/Temperature SD Card Datalogger. Instruction Manual

Visible Light SD Card Datalogger

Mini Environmental Quality Meter

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

Mini Environmental Quality Meter

Anemometer/Thermometer

Heavy Duty Hot Wire CFM Thermo-Anemometer

Mini Environmental Quality Meter

DIGITAL ANEMOMETER Model : AM-4203

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

Torque Meter. Instruction Manual

Mini Environmental Quality Meter

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

WBGT SD Card Datalogger. Instruction Manual

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

4-Channel Datalogging Thermometer

Vacuum Meter Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Light Meter (Foot Candles)

Datalogging ph Meter

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

Advanced Datalogging Thermometer. Instruction Manual

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

Datalogging RH / Temperature Pen Instruction Manual

4-Channel Thermometer

Psychrometer/Anemometer. Instruction Manual

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

PH SD Card Datalogger. Instruction Manual

WBGT SD Card Datalogger. Instruction Manual

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Type K/J Thermometers

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

CFM/CMM Hot-Wire Thermoanemometer

Datalogging Manometer

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

Hygro-Thermometer / Datalogger

Dissolved Oxygen Meter

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Heavy Duty Mini Vane CFM Thermo Anemometer

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

Datalogging IAQ Meter Instruction Manual

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

Temperature Datalogger

600 g x 0.02 g DIGITAL BALANCE

DIGITAL SOUND LEVEL METER. Instruction Manual

12-Channel Thermocouple Datalogger

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

AC/DC MAGNETIC METER

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC

Wide Range Pressure Meter Instruction Manual

4-Channel Thermometer / Datalogger

Digital Air Velocity/Flow Meter

VANE ANEMOMETER HUMIDITY/TEMP.

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

4 Channel Datalogging Thermometer. Instruction Manual

VIBRATION METER Model : VB-8213

User's Manual. VA893 Thermo Anemometer

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

Sound Level Pen Instruction Manual

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

DAF4207SD USER S MANUAL

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Datalogging Manometers 2PSI, 5PSI, 15PSI , ,

ENVIRONMENT METER WITH DATALOGGING SD CARD

Vibration Meter SD Card real-time datalogger

Hygro Thermo-Anemometer Model

3 Channel Datalogging Thermometer

Digital Air Velocity Meter DC580. The Value Leader TM

User's Guide. Cup Thermo-Anemometer. Model AN400

Heavy Duty Datalogger Module

HOT WIRE ANEMOMETER. Model : 204HA

Manual Anemometer PCE-423

Heavy Duty CFM Thermo-Anemometer Model

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD.

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

Manual Digital Thermometer PCE-T 390

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Hot Wire Thermo-Anemometer. Model

Heavy Duty Datalogger Module

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

Digital Vane Thermo-Anemometer Model

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

AquaShock ph Meter K

Transcription:

Datalogging Hot Wire CFM Anemometer 840002 Instruction Manual SPER SCIENTIFIC LTD.

TABLE OF CONTENTS 1. INTRODUCTION... 3 2. PANEL DESCRIPTION... 4-5 3. MEASURING PROCEDURE... 5 3-A Air Velocity and Ambient Temp. Measurement... 5 3-B Air Flow Measurement (CMM/CMF)... 5 3-C Zero Setting... 6 3-D Type K/J (Thermocouple) Thermometer... 6 3-E Data Hold... 6 3-F Maximum / Minimum... 6 3-G Data Logger... 6-7 4. ADVANCED ADJUSTMENTS... 7 4-A Check Remaining Available of Data Points... 7 4-B Clear Memory... 7 4-C Date/Time Setting... 7-8 4-D Sample Time Setting... 8 4-E Auto Power Off Default Setting... 8 4-F Temp. Unit Default Setting... 8 4-G Air Velocity Unit Default Setting... 8 4-H Air Flow Unit Default Setting... 9 4-I Area Size (Air Flow) Default Setting... 9 4-J Escape from Advanced Adjustments... 9 5. UPLOADING DATA FROM THE METER... 9-10 6. RS232 PC SERIAL INTERFACE... 10-11 7. BATTERY REPLACEMENT... 10 8. TROUBLESHOOTING... 11 9. OPTIONAL ACCESSORIES... 11 10. SOFTWARE... 11 11. SPECIFICATIONS... 12 12. WARRANTY... 12

1. INTRODUCTION Automatically records up to 16,000 (!) data points in the field along with time and date. These can later be downloaded to a computer via the meter s RS232 port and the results viewed instantly on software which comes with the unit. The software also enables real time data logging directly from the meter to the computer. Features air volume (CFM) air velocity min-max simultaneously displays air temperature in ºC or ºF reads type-k or J thermocouple probes calendar/clock selectable auto power off hold function detachable probe fold-out tripod large easy to read LCD Comes ready to use in a protective foam lined carrying case complete with metal vane anemometer probe, software programs on two (2) CDs, RS232 computer connection cable, 4 AA batteries, and a 3V button cell battery. - 3 -

2. PANEL DESCRIPTION 1 2 3 5 7 4 6 8 9 10 11 17 16 18 12 13 14 15 1 DISPLAY 2 POWER button 3 HOLD / ESC button 4 REC / ENTER button 5 (UP) button 6 FUNCTION / (DOWN) button 7 CLOCK / SEND button 8 LOGGER / SET button 9 TRIPOD SCREW 10 STAND 11 BATTERY COMPARTMENT/COVER 12 LCD BRIGHTNESS ADJUSTMENT VR 13 SYSTEM RESET 14 RS232 OUTPUT TERMINAL 15 DC 9V POWER ADAPTOR SOCKET 16 TYPE K/J THERMOCOUPLE PROBE INPUT 17 PROBE INPUT SOCKET 18 PROBE LOCK SWITCH ( LOCK ON/OFF) - 4 -

20 21 22 19 19 PROBE PLUG 20 SENSOR HEAD 21 RETRACTABLE SENSOR COVER 22 TELESCOPING PROBE HANDLE CAUTION: When the probe is not in use, always protect the SENSOR HEAD (20) with the RETRACTABLE SENSOR COVER (21). Never touch or insert anything into the SENSOR HEAD (20). Doing so will void the warranty and may cause permanent damage to the probe. 3. MEASURING PROCEDURES See "Advanced Adjustment Procedures" (pg 7) to set the default temperature scale ( C or F), air velocity unit, (m/s, Ft/min, Km/h, Knots or Mile/h), air flow measurement (CMM or CMF), and area size (Meter^2 or Ft^2). 3-A. Air Velocity and Ambient Temperature Measurement Insert the PROBE PLUG (21) into the PROBE INPUT SOCKET (17). Slide the PROBE LOCK SWITCH (18) to the LOCK position. Turn on the meter by pressing the POWER (2) button. The air velocity readings are displayed as m/s, Ft/min, Km/h, Knots or Mile/h. The ambient temperature is displayed in C or F. Extend the TELESCOPING PROBE HANDLE (22) to desired length. Slide the protective RETRACTABLE SENSOR COVER (21) down. Aim the white dot on the SENSOR HEAD (20) toward the air flow. To display the time (h-m-s) or date (y-m-d) during use, press the CLOCK (7) button. Press the POWER (2) button to turn the unit off. 3-B. Air Flow Measurement - CMM/CMF The procedures are the same as above (3-A). Press the FUNCTION (6) button to toggle between air velocity and air flow readings. The display shows the reading and the area size in meter^2 or ft^2. To display the time (h-m-s) or date (y-m-d) during use, press the CLOCK (7) button. Press the POWER (2) button to turn the unit off. - 5 -

3-C. Zero Setting Slide the RETRACTABLE SENSOR COVER (21) up over the SENSOR HEAD (20) Press the UP (5) for about 2 seconds, or until the air velocity value equals zero. 3-D. Type K, J Thermometer Measurement Unlock and remove the anemometer sensor from the meter and slide the PROBE LOCK SWITCH (18) to the LOCK position. Insert the thermocouple probe in the TYPE K/J PROBE INPUT (16). Turn on the meter by pressing the POWER (2) button. Press the FUNCTION (6) button to switch between type K or J, "J type" or K type" will be displayed. 3-E. Data Hold While measuring, press the HOLD (3) button to freeze the displayed value. "HOLD" and the measurement are displayed. Press the HOLD (3) button again to exit. 3-F. Maximum / Minimum To record the maximum and minimum readings: Press the REC (4) button once. "REC" appears on the LCD. Press the REC (4) button again. "MAX", "REC" and the maximum measurement appear on the LCD. Press the REC (4) button again. "REC Min" and the minimum measurement appear on the LCD. To exit this function, press and hold the REC (4) button for at least 2 seconds, until the display reverts to the current reading. 3-G. Data Logger The data logger function can save up to 16,000 data points along with the time (hour-min-sec) and date (year-month-day). When there are 16,000 data points in memory, the display indicates "FULL." To momentarily display sampling time, press the LOGGER (8) button once. To change the sampling time, see item 4-D on page 8. Press the REC (4) button once, "REC" will be displayed. Depending on your set sampling time, continue to step "a" or "b" (below). - 6 -

a. Auto Data Logger (sampling time can be set for 2 seconds to 8 hours, 59 minutes, 59 seconds): Press the LOGGER (8) button once, "REC DATA" is displayed and "Recording...." flashes at each preset interval. Press the LOGGER (8) button again to exit. "REC" is still displayed, but "DATA" is no longer shown. To resume data logging, simply press the LOGGER button (8) again. To exit the "REC" function, press and hold the REC button (4) for at least 2 seconds. b. Manual Data Logger (sampling time MUST be set to "0" zero): Press the LOGGER (8) button once to save each data point. To exit this function, press and hold the REC button (4) for at least 2 seconds. 4. ADVANCED AJUSTMENT PROCEDURES Press the SET button (8) for at least two seconds to enter the advanced adjustment procedures. Press the ESC (3) button to exit. Before executing the advanced adjustment procedures, exit the HOLD and RECORD functions. 4-A. Check Remaining Available of Data Points Press the SET button (8) at least 2 seconds until the lower display shows: "XXXXX" is the number of free data points. XXXXX Memory Space 4-B. Clear Memory Clear Memory Esc:N Enter:Y Press the SET (8) button as needed to reach the 107 "clear memory" screen. The number of saved data points is displayed. To delete saved data from memory, press the ENTER (4) button once, then press ENTER (4) button again to confirm your action. The display shows: "0 Ok ESC:Quit". If you DO NOT want to clear the memory, press the ESC (3) button to exit, or press the SET (8) button to advance to the next option. 4-C. Date/Time Setting 06:01:03 Date/Time Set y-m-d Press the SET button (8) as needed to reach ^, v ENTER( ) the "date/time set" screen. Use the UP (5), DOWN (6), and ENTER (4) buttons to select the - 7 -

year, month, date, hours, minutes and seconds. Press the ENTER (4) button to save the settings. Press the SET (8) button to advance to the next option, or press the ESC (3) button to exit. 4-D. Sample Time Setting 00:00:02 Sample Time Press the SET (8) button as needed to reach the "sample time" screen. h-m-s ^, v ENTER( ) Use the (5), (6), and ENTER (4) buttons to select the sample time (hour-min-sec). Press the ENTER (4) button to save the settings. Press the SET (8) button to advance to the next option, or press the ESC (3) button to exit. 4-E. Auto Power Off Default Setting 1 = Auto Power Off - Enabled 0 = Auto Power Off - Disabled The meter will automatic shut off after about 10 minutes without activity. Press the SET (8) button as needed to reach the "auto power off" screen. Use the (5) or (6) buttons to enable / disable this feature. Press the ENTER (4) button to save the settings. Press the SET (8) button to advance to the next option, or press the ESC (3) button to exit. 4-F. Temp Unit Default Setting Press the SET button (8) as needed to reach the "temp. unit" screen. Use the UP (5) and DOWN (6) buttons to switch between F and C. Press the ENTER (4) button to save the settings. Press the SET (8) button to advance to the next option, or press the ESC (3) button to exit. 4-G. Air Velocity Unit Default Setting Press the SET (8) button as needed to reach the "default vel." screen. Use the UP (5) and DOWN (6) buttons to switch between m/s, Ft/min, Km/h, Knots, Mile/h. Press the ENTER (4) button to save the settings. 1 = F 0 = C 0 = m/s 1 = Km/h 2 = Ft/min 3 = Mile/h 4 = knot Press the SET (8) button to advance to the next option, or press the ESC (3) button to exit. - 8 -

4-H. Air Flow Unit Default Setting 1 = CFM Press the SET (8) button as needed to reach the "CFM/CMM" 0 = CMM screen. Use the UP (5) and DOWN (6) buttons to switch between CMM (cubic meter per minute) and CFM (cubic feet per minute). Press the ENTER (4) button to save the settings. Press the SET (8) button to advance to the next option, or press the ESC (3) button to exit. 4-I. Area Size (Air Flow) Default Setting Press the SET (8) button as needed to reach the "area:meter^2" screen. CMM: Use the UP (5), DOWN (6), and SEND (7) buttons to enter an area size from 0.001 to 30.000 square meters. CFM: Use the UP (5), DOWN (6), and SEND (7) buttons to enter an area size from 0.01 to 322.91 square feet. Press the ENTER (4) button, then press the ESC (3) button to save the setting and exit this function. 4-J. Escape from Advanced Adjustments For the above procedures (B through F), press the ESC (3) button before pressing the ENTER (4) button to exit advanced adjustments without saving the changes. 5. UPLOADING DATA FROM THE METER To upload the data to a computer, connect the RS232 cable and run the software (pg 11). You can only send one memory block at a time. First, cancel the HOLD and RECORD functions if they are activated. Press the SEND (7) button for at least 2 seconds until the bottom right display shows "Transmit mode." Release the button. The following screens flash alternately: 0.3 m/s 1 m/s xx:xx:xx Transmit Mode 1 Transmit Mode start time the first data memory block start data address of each block of each block number of each block (1-250) - 9 -

The meter can record up to 16,000 data points, stored in a maximum of 250 memory blocks. All data points saved during one data logging session are stored in one memory block. Block 1 Block 2 Block 250 Data 1 Data X+1 Data Z To Data X To Data Y To Data 16,000 Use the UP (5) and DOWN (6) buttons to select the desired memory block number (1 to 250) and push the SEND (7) button once. The bottom right of the display shows "Sending Data!". When the process has finished, "Transmit mode" is displayed. Push the ESC (3) button to exit this function. 6. RS232 PC SERIAL INTERFACE The instrument features a 3.5 mm RS232 OUTPUT TERMINAL (14). The signal output is a 16-digit data stream that can be adapted to user-defined applications. A RS232 lead with the following connection is required to link the instrument with the PC serial interface. The 16 digits data stream will be displayed in the following format: D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status: D0 D1 & D8 D9 Meter (3.5 mm jack plug) PC (9W D Connector) Center Pin... Pin 4 Pin 2 2.2 K Ground/shield... Pin 2 Pin 5 resistor End Word = 0D Display reading, Dl = LSD, D8 = MSD (If the display reading is 1234, then D8 to D1 is: 00001234) Decimal Point (DP), position from right to the left D10 D11 & D12 Polarity: 0 = Positive 1 = Negative Annunciator for Display C = 01 Knot = 90 mile/h = 12 F = 02 Km/h = 10 CMM = 84 m/s = 08 ft/min = 11 CFM = 85-10 -

D13 The upper display data = 1, The lower display data = 2 D14 4 D15 Start Word = 02 RS232 Com Port Setting: 9600, No parity, 8 Data bits, 1 Stop bit 7. BATTERY REPLACEMENT When the left corner of the LCD displays the low battery icon install 4 new AA 1.5V batteries. Slide the BATTERY COVER (10) away from the instrument to remove the old batteries. When the clock is no longer accurate, replace the 3V button cell battery located in the compartment behind the AA's. Reattach the battery cover when you have finished. In-spec measurements may be made for several hours after the low battery indicator appears. 8. TROUBLESHOOTING To reset the system, slide the PROBE LOCK SWITCH (18) between the "On" and "Off" positions once or twice. Or, gently insert a pin or small object into the SYSTEM RESET (13) while turning on the meter. 9. OPTIONAL ACCESSORIES 840090 Water Resistant Instrument Pouch 840092 Bench-Top Tripod 840093 Field Tripod 840094 USB RS232 Serial Adapter 840097 AC to DC 9V Adapter Type K and Type J Probes 10. SOFTWARE The software CDs feature auto-installation. To use the programs, simply install and follow the on-screen instructions. 850080 - Provides real-time data acquisition of multiple sensors, data logging, text display, angular display, chart display, data recorder high/low limit, data query, text report, chart report. The ".mdb" data file can be retrieved in MS Excel, MS Access and other applications. 850090 - Used to download the data log from the meter to the computer. The standard text data file ".dat" may be converted with MS Excel, MS Access and other applications to ".mdb" format. - 11 -

11. SPECIFICATIONS Air Volume Range Res. Accuracy CMM (m3/min) 0 ~ 36,000 0.001 ~ 1 0.001 ~ 30.0 CFM (ft3/min) 0 ~ 1,271,200 0.01 ~ 100 0.01 ~ 322.91 Air Velocity Range Res. Accuracy M/s 0.2 ~ 20.0 Km/h 0.7 ~ 72.0 Mile/h 0.5 ~ 44.7 0.1 ±(2%+ 0.2d) Knots 0.4 ~ 38.8 Ft/min 40 ~ 3940 1 ±(2%+ 20 ft/min) Air Temp. Range Res. Accuracy Temp ºC 0 ~ 50ºC 0.8ºC 0.1º Temp ºF 32 ~ 122ºF 1.5ºF Thermocouple Range Res. Accuracy -58~2372ºF ±(0.2% + 1ºF) Type K -50~1300ºC ±(0.2% + 0.5ºC) 0.1º -58~2012ºF ±(0.2% + 1.8ºF) Type J -100~1100ºC ±(0.2% + 1ºC ) Type K/J specification tests under the environment RF Field Strength less than 3 V/M and frequency less than 30 MHz. Temp. Compensation Automatic for K/J thermometers Misc. Operating Conditions 0 to 50 C, Less than 80% RH. Display Sampling Approximately 1 second. Time Approximately DC 21.5 ma for the meter. DC Power Drain 27.5mA for the meter and anemometer probe. Meter dim: 7 ¾" x 3" x 1½" (200 x 76 x 37 mm) Sensor diameter: ½" (13 mm) Probe length fully extended) 38" (965 mm) Dimensions Cable length probe extended: 41½" (1054 mm) Probe length fully retracted: 10" (254 mm) cable length probe retracted: 69½" (1765 mm) Weight: 31 oz (515 g) WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, or damage resulting from accident, misuse, or abuse of the product. In order to obtain warranty service, simply ship the unit postage prepaid to: SPER SCIENTIFIC LTD., 7720 East Redfield, Suite 7, Scottsdale, AZ 85260M (480) 948-4448, www.sperscientific.com, info@sperscientific. com. Please Note: The defective unit must be accompanied by a description of the problem and your return address. Rev. 4/28/06-12 -