QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Similar documents
Room unit with PPS2 interface

Room unit with PPS2 interface

Room unit with PPS2 interface

Room unit with PPS2 interface

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Extension module for lighting control

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room Temperature Controller

Digital input modules

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

PXR11 PXR12. System controllers DESIGO PX

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

TXM1.8RB. TX-I/O Blinds module

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Island bus expansion module

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Semi flush-mounted room temperature controllers with LCD

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Power supply module, bus connection module

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Master room unit for RRV controllers

BACnet/IP Web Interface

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Room Temperature Controller

RMZ790. Operator Unit. Building Technologies. Synco 700

Resistance measuring module

Rotary version, three-position control

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Handheld Tool for VAV compact and modular controllers

Super universal modules

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Semi Flush-mount Room Temperature Controllers with LCD

Interface converter for VAV compact controllers

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Electromotoric actuators

Web interface BACnet/IP

Room Temperature Controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

LON Module for Variable Speed Drive

VAV modular controller

Semi flush-mounted room temperature controllers with LCD

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Freely configurable flush-mounted room operator unit for KNX PL-Link

VAV compact controller

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Non-communicating room controllers

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Network node WTT56.. A6V _en--_c Building Technologies

Rotary actuators for ball valves

Extension module for Web functions generic

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Extension module for graphic Web functions for one automation station

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

AEW Pulse Adapter. Building Technologies

Room automation station

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

EY-RU : Room operating unit, ecounit

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Temperature controller Ducted systems

Airflow Pressure Sensor

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

EY-RU : Room operating unit, ecounit

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room automation stations

Product and Application Description

EY-RU 355: Room operating unit, ecounit355

Fast running actuators for air dampers

Automation stations compact model

Air damper actuators

ERF910. RF Repeater. Synco living

Non-communicating room controllers

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Immersion Temperature Sensors

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)

EY-RU : Room operating unit, ecounit

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

SEH62.1. Digital Time Switch

EY-SU 358: Push-button unit for room operating unit, ecounit358

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Building Technologies. Desigo RXC Room automation system System description. Version 5 and later

EY-RU : Room operating unit, ecounit

Room thermostat with KNX communications For VAV heating and cooling systems

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Heating Circuit Controller

Automation station, compact series

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Push Button Interface UP 220D31

24-hour room temperature controller

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Electromotoric actuators

Transcription:

1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature measurement Buttons for adjustment of the room temperature setpoint Rocker switch for mode selection ( / Auto) and for manual control of the fan in fan-coil systems (up to 3 speeds) LCD with room temperature and control mode display Panel for configurable buttons for the operation of lighting and blinds Off-button ( ), to switch room lighting off and set HVAC system to an energysaving mode LONMARK -compatible bus communications Power supply via the two-wire bus (LONWORKS bus, LPT-10) Socket for RXT10 commissioning and service tool CA2N1648en_05 2015-12-23 Building Technologies

Use The flexible room unit is used in conjunction with the Desigo RXC room automation system for measurement of the room temperature and for integrated operation of HVAC, lighting and blinds. The HVAC functions are identical to those of the QAX34.1 room unit. The functions for operating lighting and blinds can be configured flexibly to match the requirements in the room. This involves fitting the required rocker switches and downloading the associated application software (referred to further on as the application ). The various applications are described individually in the Desigo RXC Applications library, CA2A3810 (V1) or CA110300 (V2). The flexible room unit is delivered in its unconfigured state (see Ordering ). The room units must be fitted with buttons/rocker switches and loaded with the application at the commissioning stage. The latter process is carried out with the RXT10 commissioning and service tool (see Commissioning notes ). Type summary The flexible room unit is available in two basic versions, which differ only in the number and type of buttons/rocker switches supplied. 80067 A QAX50 2 x + 4 x 3 x 4 x 1 x 2 x 80068 A QAX51 2 x + 1 x 4 x 3 x 1 x 3 x Type QAX50 is used for all applications involving on/off lighting control. Type QAX51 is required for dimmer control. Product No. Stock number Designation QAX50.5/C000 S55623-H114 Flexible room unit (on/off lighting control) QAX51.5/C000 S55623-H115 Flexible room unit (dimmer control) 2/10

Ordering When ordering, please specify the quantity, product name, type code and configuration. Unconfigured room units Unconfigured units are available only in the basic versions shown under Type summary above. The configuration code for these units is C000. Example: 7 Flexible room units QAX51.5 / C000 Button sets The two different button sets can also be ordered separately: Set A: SAP ordering No. 4268 277 30 (on/off lighting control) Set B: SAP ordering No. 4268 277 40 (dimmer control) Equipment combinations The QAX50 and QAX51 are primarily used in conjunction with the RXC30 / RXC31 / RXC38 room controllers and the associated extension modules, types RXC40 and RXC41. The room units are also used in conjunction with the RXC20, RXC21, or RXC22 for fancoil applications. The flexible room units can also be used for the control of lighting and blinds (and to a limited extent HVAC) in conjunction with LONMARK -compatible third-party devices. Mechanical design The room unit is designed for mounting on a recessed conduit box. The bus cable is connected to the unit from the rear with a plug-in connection. Essentially, the flexible room units comprise a housing and base unit, connected by releasable snap-fittings. The housing accommodates a printed circuit board, room temperature sensor element, buttons for setpoint adjustment, mode selection and fan-speed control, the LCD panel, a configurable control panel, a plug-in connector for the bus and a socket for the RXT10 commissioning and service tool. The configurable control panel incorporates two rubber membranes and a total of 10 contact points. The contacts are operated by the buttons and rocker switches fitted into the panel. The flexible room unit has a plastic housing and a galvanized steel mounting plate. Mounting plate 80075 Housing Plug-in connector for bus Socket for commissioning and service tool 3/10

Operator controls and display 80069 A Buttons for adjustment of the room temperature setpoint Room temperature and control sequence (heating / cooling) display Display of current control mode or current fan speed Rocker switch for selection of control mode and fan speed Configurable control panel (example of configuration) Note The actual functions of the operator controls and display panel are determined by the downloaded application. The description below covers all the possible options. Rocker switch for mode selection and fan-speed control The control mode of the connected room controller can be selected with the rocker switch. The same switch is used for manual control of the up to three fan speeds. Pressing once in the direction of the left arrow switches one stage to the left, and pressing once in the direction of the right arrow switches one stage to the right. The current control mode or manually-selected fan speed is indicated in the display panel by a horizontal bar below the associated symbol. Position Fan speed control 1) Control mode 1) Fan controlled automatically by room controller Fan controlled automatically by room controller Manual, fan speed 1 Manual, fan speed 2 Manual, fan speed 3 Pre-comfort or Economy (according to central control) Comfort 1) For function descriptions of the relevant HVAC applications refer to the Desigo RXC Applications library, CA2A3810 (V1) or CA110300 (V2). Note The operation of this rocker switch has no effect on the control of lighting or blinds. Buttons for room temperature setpoint adjustment Press the button once to switch from a display of the current room temperature to a display of the setpoint. Each further operation of the + or button raises or lowers the setpoint by 0.5 K or 1.0 F. The unit of measurement and the maximum allowable adjustment range is determined by parameters in the application software. 4/10

LCD display In normal operation, the following may be displayed (depending on the application parameters) For details refer to the Desigo RXC Applications library, CA2A3810 (V1) or CA110300 (V2).: Display element (examples) Description Room temperature in C (resolution 0.5 C) Room temperature in F (resolution 1.0 F) Digital display of setpoint adjustment (displayed only while relative adjustment is in progress). Digital display and scale (displayed only while absolute adjustment is in progress) Control sequence: Cooling Control sequence: Heating Room units with mode and fan-speed selection enabled: Fan speed 1: ON In room units allowing mode selection only: Auto: ON Configurable control panel The configurable control panel can be fitted according to requirements with a variety of buttons and rocker switches. The following options are available: Large button for on/off control of lighting Standard button for on/off control of lighting Rocker switch for on/off control of two lighting units Rocker switch for dimmer control Rocker switch for control of blinds OFF button: Switches all room lighting off Switches the connected room controller to Pre-comfort or Economy Blank plate (no function) Note Flexible room units configured with an OFF button incorporate the following additional function: If the connected room controller is in Pre-comfort or Economy mode, it will switch to Comfort as soon as any of the rocker switches or buttons on the room unit are operated. 5/10

Removing the buttons/rocker switches 80096 A Search LED Service LED There are two LEDs under the top button/rocker switch on the configurable control panel. These remain permanently on so that the unit can be located more easily in the dark. The yellow Service LED is fitted under the last button/rocker switch on the configurable panel and indicates the status of the room unit by means of different flashing patterns (see the RXT10 user manual, CM110669). Disposal The devices are classified as waste electronic equipment in terms of the European Directive 2012/19/EU (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Engineering notes The flexible room unit is connected to the LONWORKS bus by a two-wire twisted cable and receives its power via the bus cable. This cable must be connected to a central bus power supply in accordance with LPT-10 (see the Installation guide, CA110334). For mounting, a standard recessed conduit box or an aperture of the equivalent size is required. Mounting notes The room unit must be mounted on a recessed conduit box Mount on a flat surface with a maximum offset of 1 mm The base plate should be fixed with screws, max. diameter 3.5 mm Do not mount in recesses, shelves, behind curtains or doors, or above or near heat sources. Avoid exposure to direct sunlight or draughts. The electrical wiring conduit must be sealed where it joins the room unit, to prevent the occurrence of draughts in the conduit which could affect the sensor. The specified ambient conditions must be complied with. Mounting instructions are printed on the room unit packaging. 6/10

1 80091 A 2 Fit to top rail (1) and snap-mount on bottom rail (2) Installation notes Local installation regulations must be observed. Do not route mains voltage cables to the conduit box. Use only the original bus plug. STOP Warning The room unit is not protected against connection to AC 230 V. Commissioning notes The QAX50 and QAX51 flexible room units are commissioned with the RXT10 commissioning and service tool. This is connected to the LONWORKS bus via the tool socket. The RXT10 user manual (CM110669) contains a step-by-step commissioning procedure for the entire Desigo RXC range. Response on start-up When the supply voltage is connected (via the LONWORKS bus) the room unit runs a self-test, during which all segments of the LCD are enabled. At the end of the self-test, the LCD panel reverts to the normal display. Service pin function The service pin function, which is used to transmit the identification number of the unit to the bus can be enabled by simultaneously pressing the two setpoint adjustment buttons and the mode selection/fan-speed rocker switch (to the left or right). The LCD panel displays for approximately 1 to 2 s in acknowledgement. 80112 Press simultaneously Wink function display If the RXT10 commissioning and service tool is used to issue an identification command to in the room unit (wink function), the LCD panel responds with the display. This display persists for a maximum of 64 s or until a rocker switch or button is operated. The room unit then reverts to the normal display. 7/10

Notes on operation During normal operation and commissioning, the LCD panel also serves to display error messages: Display Description Room temperature sensor outside range 0... 40 C Technical data Power supply Operating voltage Max. DC 42 V (SELV) Max. DC 42 V class 2 (US) The Room unit receives its power via the LONWORKS bus in accordance with specification LPT-10 Power consumption Max. 0.3 W Function data Temperature sensor Measuring element NTC resistor Measuring range 0... 40 C Response time 9 min Measuring accuracy (5... 30 C) ± 0.5 K Measuring accuracy (25 C) ± 0.25 K Setpoint correction Correction range (defined by application Max. ± 10 K (default ± 3 K) parameters) Display Type LCD Functions displayed Room temperature Setpoint adjustment Operating status Manually selected fan speed Control sequence (heating / cooling) Configurable operator panel Number of contact points 10 Max. number of buttons/rocker switches 5 Functions On/off control of lighting Lighting dimmer control Blinds up/down and adjustment of slat angle OFF button Interfaces LONWORKS bus Interface type LONMARK -compatible Transceiver LPT-10 Baud rate 78 kbit/s Bus topology and bus termination See Installation guide, CA110334 Cable connection Connection terminals (plug-in screw terminals) Solid or stranded conductors 2 x 1.0 mm 2 Single cable lengths See also Installation guide, CA110334 LONWORKS bus Max. 500 m Cable type See Installation guide, CA110334 Tool connecting cable Max. 3 m (manufactured) 8/10

Protection data Housing protection IP 30 to EN 60529 Protection class III to EN 60730-1 Ambient conditions Operation IEC 721 Ambient air conditions Class 3K5 Temperature 0... 50 C Humidity < 85 %rh Mechanical conditions Class 3M2 Transport IEC 721 Ambient air conditions Class 2K3 Temperature 25... 70 C Humidity < 95 %rh Mechanical conditions Class 2M2 Standards, directives and approvals Environmental compatibility Product standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commerce, lightindustrial and industrial environments EU conformity (CE) CA2T1648xx *) UL certification (US) UL916, http://ul.com/database RCM-conformity (EMC) CA2T3834en_C1 *) Product environmental declaration (contains CA2E1648 *) data on RoHS compliance, materials composition, packaging, environmental benefit, disposal) Dimensions See "Dimensions" Color Front plate and operator control panel NCS S 0502-G, RAL 9003 signal white Buttons/rocker switches for setpoint adjustment RAL 7035 light grey and mode selection Weight Excluding packaging 0.175 kg *) The documents can be downloaded from http://siemens.com/bt/download. Connection terminals The LONWORKS bus connection terminals are removable, so that if the bus cable is looped, the room unit can be separated from the bus without causing an open circuit. Terminal layout CLA CLB LONWORKS bus, Data A LONWORKS bus, Data B Tool socket CLA CLB 9/10

Dimensions All dimensions in mm Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2000 Delivery and technical specifications subject to change 10/10