Instruction Manual Model Block Translator

Similar documents
POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

Model L 10MHz Frequency Source, Switch, Inserter

Model x-Series

S-Band Redundant LNA Systems

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Modular Block Converter Systems

NAVE IIc. Nielsen Audio Video Encoder Compressed. Quick Start Guide

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Data Broadcast Switch

ViaLite RF Splitter / Combiner

1:N REDUNDANT SWITCHING UNIT BROADBAND SERIES

LASER PLUS OPERATING INSTRUCTIONS

1073N. Channel Amplifier. User Manual Issue 1.3

User Manual. Per Port Monitoring Models

SI3300. user and installation manual. 4-20mA/DC-Digital Display

MODEL 715AN QUADRATURE DEGREES COUNTER

Enhanced Mini-Chansim Model VCS-232

TRC-190 User s Manual

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

SLSM5 SYNTHESIZER INTERFACE DEFINITION PLL IC

AS-AMP1 40 Watt Digital Amplifier User Manual

imaging Series Quartet Guide to Installation and Operation M

V-9908 MESSAGE/PAGE PANEL

FD141CV-C-1. Installation and Operation Manual. 14 Widescreen HD Display. Revision Date: 05/04/2017 Page 1 of 15. Rev: B

Series 8000 RF Signal Switch Solution

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Series 8000 RF Signal Switch Solution

Compact Redundancy Switch 2:1 RSCC-2

DL-HDM44A-H2 Quick Install Guide

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

HA-10 Vacuum Tube Headphone Amp

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ES-600 Ozone Controller Operation Manual

Compact Redundancy Switch 2:1 RSCC-2

iconverter 2-Module Power Chassis

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

1:1 C-Band LNA Redundancy System

ANC Series RS-422 Serial Communications Adapter

MPT-250A SPECIFICATIONS AND OPERATING INSTRUCTIONS

user and installation manual

20W Tungsten-Halogen Light Source. Operation Manual

AirTest Model CN9000 Series Sensor Controller

Installation and Operating Handbook. ICLH Combiner ISLH Splitter

Model No. ST200-S-RCP

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

B Polling Interface

Installation & Operation

Multi-Port Controller

Thermoelectric Cooler Controller TED1000

SURGE PROTECTION DEVICE RECOMMENDED

FA-2448 SIX POSITION Filter Wheel

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

TRC-190 User s Manual

PCM Operation Manual. Pulsed Current Source. Fort Collins, Colorado Phone Fax

USER MANUAL. S3MBW HDMI Multi-format Extender Over CAT5e/CAT6. Back View. Front View. Covid Part Numbers

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Conitel ASYNC Adapter

MODEL No. SW1X8 RS422 SWITCHER

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MTS-2000 USER S MANUAL

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Miniature Overhead Stirrer

C-Band Solid-State Power Amplifiers

Features. IDS : Inclinometer Display System with RS232 Output

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

WR-5e Remote Control

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MODEL 716AN SSI REMOTE DISPLAY DESIGN CONCEPTS INC

Ashly WR-5 Remote Control

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

UF-1000CL High Speed CCD Camera User's Manual

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

USS-600CL Digital CCD Camera User's Manual

RT1. Real Time Spectrum Analyser Preliminary Operating Instructions

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

I/O SIGNAL CONDITIONER

Agilent 70612B K18 Switch Matrix

AMS16 2AM & AMS16 2AEM 16 CHANNEL AUDIO MONITORING SYSTEM

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

UP-800CL Digital CCD Camera User's Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Kramer Electronics, Ltd. USER MANUAL. Model: VS-1616A. 16x16 Balanced Stereo Audio Matrix Switcher

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Redundancy Switch Controller 1:1 RSCM1

INSTRUCTION and OPERATIONS MANUAL. for

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

Trillium US Inc. E1000 Dual Channel Temperature Monitor / Water Pump Controller User s Manual Rev A / March 2016

Integrated Stepper Drive & Motor

CA-A480-A Elevator Controller. Reference & Installation Manual

Digital Lighting Systems, Inc.

Transcription:

Instruction Manual Model 2083-1010 Block Translator May 2018, Rev. 0 1250>1200 G=-10.0 REF = AUTO - I MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 2083-1010 Block Translator TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 1.3 Monitor & Control Interface 6 2.0 Installation 11 2.1 Mechanical 11 2.2 Rear I/O s 12 2.3 Front Panel Controls, Indicators 13 2.4 Operation 14 2.5 Menu Settings 15 3.0 Environmental Use Information 19 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 2083-1010 Manual, Rev. 0 Page 2 05/22/18

MODEL 2083-1010 Block Translator 1.0 General 1.1 Equipment Description 2083-1010 Block Translator - The 2083-1010 Block Translator converts a 1000-1500 MHz block to 950-1450 MHz block with no spectrum inversion, low group delay and flat frequency response. The 1000-1500 MHz input is mixed with synthesized local oscillator (LO) signals, first to 3800 MHz center frequency and finally to the 950-1450 MHz block output. The gain can be set for 0 to -20 db in 0.5±0.5 db increments. Multifunction switches select the Gain and internal or External (Option E) 10 MHz reference which appear on the LCD display and can be adjusted remotely. Front panel LEDs provide indication of DC power (green), PLL alarm (red), and remote operation (yellow). Connectors are BNC female for RF input and output. The unit is powered by a 100-240 ±10% VAC, 47-63 HZ input power supply and housed in a 1 3/4 X 19 X 16 rack mount chassis. 1250>1200 G=-10.0 REF = AUTO - I MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE FRONT AC GND 10 MHZ REF OUTPUT MONITOR AND CONTROL 5 4 3 2 1 9 8 7 6 10 MHZ EXT REF INPUT IF IN RF OUT J18 J10 J3 J4 J20 J5 REAR FIGURE 1.1 Model 2083-1010 Front and Rear Panels 1000-1500 MHz IN 5050 MHz 3500-4100 MHz BP ATT 5000 MHz 1800 MHz LP Filter **EXT 10 M 950-1450MHz Out I**NT/EXT CONTROLLER I**OPTIONAL 2083-1010 Translator Block Diagram FIGURE 1.2 Model 2083-1010 Translator Block Diagram 2083-1010 Manual, Rev. 0 Page 3 05/22/18

1.2 Technical Characteristics TABLE 1.0 2083-1010 Block Translator Specifications** Input Characteristics Input Impedance/RL Frequency Input Composite Level Input, max. no damage Output Characteristics Impedance/RL Frequency Output Composite Level Output 1 db Compression Channel Characteristics Gain Frequency Response Spurious, Inband Spurious, Out of Band Frequency Sense Synthesizer Characteristics Translation; Accuracy Reference Frequency Step 50Ω/12 db 1000-1500 MHz -25 to -5 dbm +15 dbm 50Ω / 12 db 950-1450 MHz -25 to -5 dbm +5 dbm, at maximum gain 0 to -20 db, ±1 db, selectable in 0.5± 0.5 db steps ± 1.5 db, 500 MHz bandwidth; ± 0.5 db, any 40 MHz increment < -50 dbc in band, signal dependent and signal independent; -5 dbm out; See NOTE 1 < -30 dbc, 0.5-1.19 GHz and 1.71-2.2 GHz; -5 dbm out; See NOTE 1 Non-inverting *NOTE 1: dbc is relative to the COMPOSITE Output Level 1ppm; Option -H, ±0.01 ppm 10 MHz Internal; Option -E, Internal / External Selection None, fixed frequency Phase Noise @ Frequency 100 MHz 1kHz 10kHz 100kHz 1MHz dbc/hz -70-70 -80-90 -100 Controls, Indicators Fc Translation Gain (MGC) External Ref. (Option -E) Power, Alarm; Remote Remote Other RF In/RF Out Connector 10 MHz Out Connector Alarm/Remote Connector Size Direct readout LCD; manual or remote selection Direct readout LCD; manual or remote selection Direct readout LCD; manual or remote selection Green LED; Red LED; Yellow LED RS232C, 9600 Baud; RS485, Ethernet Options BNC (female) BNC (female), 75Ω, works with 50 or 75 ohms DB9 (female); No or NC contact closure on Alarm 19 inch Standard Chassis 1.75 high x 16.0 deep Power 100-240 (±10%) VAC, 47-63 Hz, 30 watts maximum Available Options (see page 5...) **+10 C to +40 C; Specifications subject to change without notice. Cross Technologies, Inc. 2018 2083-1010 Manual, Rev. 0 Page 4 05/22/18

1.2 Technical Characteristics, continued... Available Options (2083-1010 Block Translator) E - External 10 MHz Input and Output H - High Stability (±0.01) Internal Reference Communication Interface / Standard RS232 Q - RS485 Remote Interface W8 - Ethernet; with Web Browser W18 - Ethernet; with Web Browser & SNMP W28 - Ethernet; with TCP/IP, Telnet Connector /Impedance Std - NN - SS - 50Ω BNC (RF IN), 50Ω BNC (RF OUT) 50Ω N (RF In), 50Ω N (RF Out) 50Ω SMA (RF In), 50Ω SMA (RF Out) Contact Cross Technologies for other options. 2083-1010 Manual, Rev. 0 Page 5 05/22/18

1.3 Monitor and Control Interface A) Remote Serial Interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option -Q) M&C Cable Diagram - Cross Technologies Frequency Converters and Frequency Sources Female DB-9 PC Com Port 1 2 3 4 5 6 7 8 9 Male DB-9 1 2 3 4 5 6 7 8 9 Connector: Rear panel, DB-9 male J10 Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 2083-1010 Manual, Rev. 0 Page 6 05/22/18

B) Status Request/Inquiries - Table 1.0 lists the Status Request/Inquiries for the 2083-1010, and briefly describes them. General Command Format - The general command format is {aacnd...}, where: { = start byte aa = address (RS-485 only - option -Q) C = 1 character, either C (command) or S (status) N = 1 character command or status request D = 1 character or more of data (depends on command) } = stop byte * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. TABLE 1.2 2083-1010 Status Request/Inquiries Command Syntax* Description Gain Inquiry {aasg} returns: {aasgxxxx} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit G = command code xxxx = gain in db (decimal point omitted) The unit will append the '>' character if the command is sucessfully processed. Reference Mode Inquiry {aase} returns: {aasex} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit E = command code x = 0 if reference mode is internal, x = 1 if external, x = 2 if auto The unit will append the '>' character if the command is sucessfully processed. Reference Status Inquiry {aasb} returns: {aasbx} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit B = command code x = 1 if the unit is using the external reference, x = 0 if the unit is using the internal reference note: this inquiry is useful if the reference mode is auto and the user wants to know if the unit has switched to the internal reference. The unit will append the '>' character if the command is sucessfully processed. 2083-1010 Manual, Rev. 0 Page 7 05/22/18

Table 1.2, Status Request/Inquiries continued from page 7... TABLE 1.2 2083-1010 Status Request/Inquiries Command Syntax* Description Alarm Inquiry {aasa} returns: {aasax} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit A = command code x = 0 if alarm is off, x = 1 if alarm is on. The unit will append the '>' character if the command is sucessfully processed. Product/Model Info Inquiry {aasv} returns {aasv2083-xxxx yyyy ver5.xx} where 2083-xxxx = product model yyyy = list of options, if any "ver" = separates model & options from firmware version 5.xx = firmware version 2083-1010 Manual, Rev. 0 Page 8 05/22/18

C) Commands - Table 1.0 lists the M&C Commands for the 2083-1010, and briefly describes them. After a command is sent the 2083-1310 sends a return > indicating the command has been received and executed. General Command Format - The general command format is {aacnd...}, where: { = start byte aa = address (RS-485 only - option -Q) C = 1 character, either C (command) or S (status) N = 1 character command or status request D = 1 character or more of data (depends on command) } = stop byte * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.3 2083-1010 M&C Commands Command Function Syntax* Command Description Set Gain {aacgxxxx} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit G = command code xxxx = gain in 0.5 db steps, omit the decimal point Range: = -200 to 0 in 0.5 db steps example: {CG-155} Will set the unit's gain to -15.5 db. Note: The negative sign is assumed if not included, i.e. {CG155} is parsed the same as {CG-155}. The unit will reply with the '>' character if the command is sucessfully processed. Set Reference Mode {aacex} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit. E = command code x = 0 to set to internal reference, x = 1 to set to external reference, x = 2 to set to auto reference. example: {CE2} Will set the reference mode to Auto. The unit will reply with the '>' character if the command is sucessfully processed. Table 1.3, M&C Commands continued from page 9... 2083-1010 Manual, Rev. 0 Page 9 05/22/18

Table 1.3 2083-1010 M&C Commands (continued)... Command Syntax* Description Set Remote Off {aacr0} where: aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit R = command code 0, ascii number zero. example: {CR0} Will disable the unit's serial M&C port. The unit will reply with the '>' character if the command is sucessfully processed. (Note: this command only affects the serial M&C port, the ethernet port is always on and will not be affected). Set Remote On # Just the ascii pound sign, (0x23) Will enable the unit's serial M&C port. The unit will reply with the '>' character if the command is sucessfully processed. (Note: this command only affects the serial M&C port, the ethernet port is always on and will not be affected). 2083-1010 Manual, Rev. 0 Page 10 05/22/18

2.0 Installation 2.1 Mechanical - The 2083-1010 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 2083-1010 can be secured to a rack using the 4 holes on the front panel. Figure 2.1 shows how the 2083-1010 is assembled. POWER SUPPLY FIGURE 2.1 2083-1010 Mechanical Assembly 2083-1010 Manual, Rev. 0 Page 11 05/22/18

2.2 Rear Panel Input/Output Signals - Figure 2.2 shows the input and output connectors on the rear panel. AC - POWER IN AC input for switching power supply,100-240 ±10% VAC, 47-63 Hz. J18-10 MHz REF OUTPUT (option -E) 10 MHz reference output. 75Ω BNC female connector. J10 - MONITOR AND CONTROL DB9 female connector. See Table 2.1. AC GND 10 MHZ REF OUTPUT MONITOR AND CONTROL 5 4 3 2 1 9 8 7 6 J18 J10 J3-10 MHz EXT REF INPUT (Option -E) 10 MHz external reference input, +3 dbm ± 3 dbm, 75 ohms, BNC female connector. 10 MHZ EXT REF INPUT IF IN RF OUT J3 J4 J20 J5 J2 - IF IN 1000-1500 MHz input -25 to -5 dbm See Table 2.2. J20 - ETHERNET CONNECTION RJ45 Ethernet Connector (Option W8, W18, W28) J5 - RF OUT 950-1450 MHz output -25 to -5 dbm See Table 2.2. FIGURE 2.2 2083-1010 Rear Panel I/Os TABLE 2.1 J10 Pinouts (RS-232C*) Pin Function 1 Not Used 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Not Used 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Closed 8 Not Used 9 Alarm Relay: Normally Open *Remote Serial Interface Interface: DB-9 Male Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit TABLE 2.2 Connector/Impedance Options Option IF IN RF Out STD BNC, 50Ω BNC, 50Ω -B BNC, 75Ω BNC, 75Ω -NN N for input N for output -SS SMA, 50Ω SMA, 50Ω 2083-1010 Manual, Rev. 0 Page 12 05/22/18

2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators. DS1 - REMOTE LED Yellow LED indicates remote operation. DS6 - POWER LED Green LED indicates presence of DC power. LCD DISPLAY Display shows Translator frequency in MHz and Gain in db S1 - MENU/EXECUTE BUTTON Press this to get into Program mode and to execute any changes. 1250>1200 G = -10 REF = AUTO - 1 MENU REMOTE POWER ALARM EXECUTE DS3 - DOWN ALARM LED Red LED indicates Translator alarm. S2 - VERT. TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode. Does not function in the normal display mode S3 - HORIZ. TOGGLE Horizontal toggle switch that controls which values are being adjusted. Does not function in the normal display mode FIGURE 2.3 2083-1010 Front Panel Controls and Indicators 2083-1010 Manual, Rev. 0 Page 13 05/22/18

2.4 Operation 2.4.1 Installing and Operating the 2083-1010 Block Translator 1. Connect a -25 dbm to -5 dbm signal to IF IN, J4 (Figure 2.2) 2. Connect the RF OUT, J5, to the external equipment 3. Connect 100-240 ±10% VAC, 47-63 Hz to AC on the back panel. 4. Set the gain for 0 to -20 dbm (See Section 2.5 Menu Settings). 5. Be sure DS6 (green, DC Power) is on and DS (red, Alarm) is off (Figure 2.3). 6. AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.4. There is a spare fuse in the near slot. If a fuse continues to open, the power supply is most likely defective. SPARE FUSE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm ~ INPUT 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.4 Fuse Location and Spare Fuse 2083-1010 Manual, Rev. 0 Page 14 05/22/18

2.5 Menu Settings 2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.5): Power Up Normal Display Menu 1 Menu 2 Menu 3 Menu 4 Menu 5 Gain (0 to -20, +5 db Steps) Set Unit to Remote Operation Select External 10 MHz Ref (option -E) Set Remote mode (option -Q) Set RS-485 address (option -Q) Save Menu When go to R or at end Alarm indications appear on the LEDs (See figure 2.3). All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the Save Settings? Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 2083-1010 Manual, Rev. 0 Page 15 05/22/18

2.5.2 Power On Settings NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS. When power is first applied, the LCD display goes through three steps. 1.The LCD goes black to show all segments are functioning. 2.The software version will be displayed. R E V 1. 0 0 3.The present frequency and gain of the down converter is shown. 1250 >1200 G = -10.0 REF = AUTO-1 The unit is now operational and ready for any changes the operator may desire. 2.5.3 Control Switches 1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the Menu/Execute switch and completed by pressing the Menu/Execute switch. 2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right. 3. Vertical Switch - This switch is mounted so its movement is vertical and has two functions: a. During frequency, gain changes, the vertical movement will raise or lower the number in the direction of the arrows. b. For other functions such Mute on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 2083-1010 Manual, Rev. 0 Page 16 05/22/18

2.5.4 Gain Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you have made, scroll to R and push the Menu/Execute switch and select NO in the SAVE SETTINGS? window or do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode. To change the TRANSLATOR GAIN: Push the Menu/Execute switch to get to the gain setting (See Figure 2.5 for the sequence of menu options): G = -20.0 R Pressing the Up/Down switch will change the gain in.5, 1 or 10 db steps depending on the cursor location: G = -15.0 R By using the horizontal rocker switch the cursor can be moved left or right. Pressing the Up/Down switch will toggle the display digit selected until you have the desired gain. G = -15.0 R NOTE: THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS. HOWEVER, THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW. When the display indicates the value desired you can push the Menu/Execute switch to get to the next item OR you can scroll to R and push the Menu/Execute switch to get to: SAVE SETTINGS? Y N Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to this: 1250 >1200 G = -10.0 REF = AUTO-1 Figure 2.5 gives the menu items and how to make changes. 2083-1010 Manual, Rev. 0 Page 17 05/22/18

2.5.5 Alarm Indications An alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock. The Remote LED will light when you select the Remote mode. ON POWER UP Power Up REV 1.00 NORMAL DISPLAY Normal Display 1250>1200 G= -10.0 REF = AUTO - 1 PUSH BUTTON PUSHING MENU/EXECUTE SEQUENCE Menu 1 Gain (0 to -20.0) G = -20.0 R SCROLL <> SCROLL PUSH BUTTON Menu 2 Set Unit to Remote Operation REMOTE OFF R SCROLL <> Menu 3 Select External 10 MHz Reference (Option -E) EXT REF OFF R SCROLL SCROLL <> SCROLL PUSH BUTTON PUSH BUTTON Menu 4 Set Remote Mode (Option -Q) RS 485 OFF R SCROLL <> SCROLL PUSH BUTTON Menu 5 Set RS-485 Address (Option -Q) ADDRESS = 00 R SCROLL <> SCROLL PUSH BUTTON Save? When go to end SAVE SETTINGS? Y N SCROLL <> PUSH BUTTON FIGURE 2.5 Menu Display and Sequence 2083-1010 Manual, Rev. 0 Page 18 05/22/18

3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra (Maximum Recommended Ambient Temperature). D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2083-1010 Manual, Rev. 0 Page 19 05/22/18

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 2083-1010 Manual, Rev. 0 Page 20 05/22/18