Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

Similar documents
BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Date: Vendor Name: Product Name: Product Model Number: Applications Software Version: Firmware Revision: BACnet Protocol Revision:

HMS-1655 BACnet MS/TP Protocol Implementation Conformance Statement

Distech Controls Application Specific Controllers PICS

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement OEMPrtl Pro

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

FX Server BACNET AWS Protocol Implementation Conformance Statement

Sales and Engineering Data Sheet ED

BACnet Protocol Implementation Conformance Statement Automated Logic G5RE

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

PXC Compact Series on BACnet/IP

NB-GPC Family Protocol Implementation Conformance Statement (PICS)

MatrixBBC. Protocol Implementation Conformance Statement (PICS) Product Description: BACnet Standardized Device Profile:

Honeywell Novar XIO Remote I/O Protocol Implementation Conformance Statement (PICS)

BCM-ETH BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

homelynk/spacelynk BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

TRIDIUM NIAGARA AX 3.8

Input/Output Module (IOM) Series Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement Automated Logic Corporation LGR25, LGR250, LGR1000

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Product Implementation Conformance Statement bcx1-r

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

EC-Net AX /NIAGARA AX Framework 3.5 BACNET PICS

BACnet Protocol Implementation Conformance Statement Unitary Protocol Converter (UPC)

BACnet IP Enabled InFusion Controller Bacnet-IP-IC BACnet Protocol Implementation Conformance Statement

BACnet RIB July 1, 2014

QC BAC-BOX PIC STATEMENT

BACnetRIB June 24, 2016

! BACnet Operator Workstation (B-OWS)! BACnet Advanced Operator Workstation (B-AWS)! BACnet Operator Display (B-OD)

EC-Net AX 3.6 BACnet PICS

MicroTech II Multiple Air Handler Controller

1. BACnet Protocol Implementation Conformance Statement

Additional BACnet Interoperability Building Blocks Supported (Annex K):

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

NXAC-120 Area Controller

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

BACnet Protocol Implementation Conformance Statement

1. BACnet Protocol Implementation Conformance Statement

IQ4NC/.../ BACnet PICS

BACnet RIB March,

BACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801

BACnet RIB Jan

BACnet Protocol Implementation Conformance Statement

BACnet RIB June 24, 2016

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

Wireless Pneumatic Thermostat BACnet Gateway PICS. Document No rev 01

BACnet Protocol Implementation Conformance Statement

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

SyxthSense Room Controller (SRC1) Platform. BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement (PICS) der Automationsstation miles-as29/b

Modular Series BACnet Protocol Implementation Conformance (PIC) Statement A6V Building Technologies

EC-Net AX 3.6 BACnet PICS

MULTICAL 403 MULTICAL 603

CAS BACnet Stack Product Data Sheet

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

BACnet Protocol Implementation Conformance Statement

BTL Listed March 2013

Climatix BACnet Protocol Implementation Conformance Statement (PICS)

Visi.Plus Protocol Implementation Conformance Statement (PICS)

PXC Compact Unitary Equipment Controller BACnet Protocol Implementation Conformance Statement

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

BACnet RIB July,

BACnet Protocol Implementation Conformance Statement

Keywords: PcVue, BACnet, PICS. Last Revision Date: 30 March 2011

Protocol Implementation Conformance Statement (PICS)

Field Equipment Controllers Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

DS-RP-A AE-N-I-B DM-DCC-B DS-RP-B AE-ACK-B DM-PT-A DS-RPM-B AE-ASUM-B DM-PT-B DS-WP-A AE-INFO-B DM-TS-A DS-WP-B DM-DDB-B DM-UTC-B

Integration Specification Sheet

BACnet protocol implementation conformance

Delta Controller Engine (DCE) Firmware

BACnet Protocol Implementation Conformance (PIC) Statement

Product Implementation Conformance Statement bcx-4040

ETC Reference Guide BACnet PICS for P-CCS

ENC/JACE/NXT G3 Release 3.6 Network Controllers

entelibus CPU Engine (eb-eng) Firmware

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

Product Implementation Conformance Statement bcx1-cr

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3

BACnet P.I.C.S. For RDT900 configurable controllers. Protocol Implementation Conformance Statement

BACnet PCD7.R560 BACnet PCD7.R562

Desigo PXC3 and DXR2 Automation Stations BACnet Protocol Implementation Conformance Statement (PICS) Basic documentation

BACnet protocol implementation conformance statement (PICS)

BACnet protocol implementation conformance statement (PICS)

BACnet Protocol Implementation Conformance Statement

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

Terminal Equipment Controller (TEC) Protocol Implementation Conformance Statement

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

Transcription:

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement BAC-8XXX Application Specific Controller

BACnet Protocol Implementation Conformance Statement (BACnet Testing Laboratories Version) Date: 09-14-11 Vendor Name: KMC Controls Product Name: ASC for Titus VAV Product Model Number: BAC-8XXX Applications Software Version: APP1.0.7.0 BACnet Protocol Revision: 135-2008 Version:1, Revision:7 Firmware Revision: R1.0.0.5 Product Description: The BAC-8XXX is an application specific direct digital control actuator (B-ASC) that provides precise monitoring and control of connected points. Model specific I/O: BAC-8001, BAC-8201: Single Duct Cooling only Inputs: Discharge Air Temp, Space Temp, Setpoint, and Air Flow. Binary Outputs: Actuator Drive Clockwise and Actuator Drive Counter Clockwise, BAC-8005, BAC-8205: Single Duct with Cooling/Heating Inputs: Discharge Air Temp, Space Temp, Setpoint, and Air Flow. Analog Outputs: Analog Heat and Fan Speed. Binary Outputs: Actuator Drive Clockwise and Actuator Drive Counter Clockwise, Fan Start/Stop, Heating Stage 1, Heating Stage 2 and Heating Stage 3. BAC-8007, BAC-8207: Dual Duct with Cooling and Heating, Inputs: Discharge Air Temp, Space Temp, Setpoint, Primary Air Flow, Secondary Air Flow, Primary Damper, Position, Secondary Damper position and CO2. Analog Outputs: Analog Heat and Fan Speed. Binary Outputs: Actuator Drive Clockwise and Actuator Drive Counter Clockwise, Fan Start/Stop, Secondary Actuator Clockwise, Secondary Actuator Counter Clockwise and Heating Stage/Lighting. List all BACnet Interoperability Building Blocks supported (see Annex K in BACnet 2001): DS-RP-A, DS-RP-B, DS-RPM-B, DS-WP-A, DS-WP-B, DS-WPM-B, DM-DDB-A, DM-DDB-B, DM-DCC-B, DM-DOB-B, DM-TS-B, DM-RD-B Which of the following device binding methods does the product support? (check one or more) Send Who-Is, receive I-Am (BIBB DM-DDB-A) Receive Who-Is, send I-Am (BIBB DM-DDB-B) Send Who-Has, receive I-Have (BIBB DM-DOB-A) Receive Who-Has, send I-Have (BIBB DM-DOB-B) Manual configuration of recipient device's network number and MAC address None of the above Standard Object Types Supported: OBJECT CREATABLE DELETABLE OPTIONAL PROPERTIES Analog Input No No Description, Device_Type Analog Output No No Description, Device_Type 2 of 4

Analog value No No Description, Priority_Array, Relinquish_Default Binary Output No No Active_Text, Description, Device_Type, Inactive_Text Binary Value No No Active_Text, Description, Inactive_Text, Priority_Array, Relinquish_Default Loop No No Bias, Derivative_Constant, Derivative_Constant_Units, Description, Integral_Constant, Integral_Constant_Units, Maximum_Output, Minimum_Output, Proportional_Constant, Proportional_Constant_Units Program No No Description, Description_Of_Halt, Program_Location, Reason_For_Halt File No No Description Device No No Description, Local_Date, Local_Time, Location, Max_Info_Frames, Max_Master, Multi-State Value No No Description, Priority_Array, Relinquish_Default, State_Text, 3 of 4

Data Link Layer Options (check all that are supported): BACnet IP, (Annex J) Able to register as a Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s) MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 MS/TP slave (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: Other: Networking Options (check all that are supported): Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc.: Annex H.3, BACnet Tunneling Router over UDP/IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Segmentation Capability (check all that apply): Able to transmit segmented messages Able to receive segmented messages Window Size Window Size Character Sets Supported (check all that apply): Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (ICS-4) JIS C 6226 If this product is a communication gateway, describe the non-bacnet equipment/network(s) that the gateway supports: Include any addition information about the product's BACnet capabilities relevant to interoperability: 4 of 4

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement SimplyVAV BAC-8XXX Application Specific Controller Revision A

BACnet Protocol Implementation Conformance Statement (BACnet Testing Laboratories Version) Date: 03-14-14 Vendor Name: KMC Controls Product Name: SimplyVAV Product Model Number: BAC-8XXX Applications Software Version: APP1.0.7.0 BACnet Protocol Revision: 135-2008 Version:1, Revision:7 Firmware Revision: R1.0.0.5 Product Description: The BAC-8XXX is an application specific direct digital control actuator (B-ASC) that provides precise monitoring and control of connected points. Model specific I/O: BAC-8001: Single Duct Cooling/Heating Inputs: Discharge Air Temp, Space Temp, Setpoint, and Air Flow. Binary Outputs: Actuator Drive Clockwise and Actuator Drive Counter Clockwise, BAC-8005, BAC-8205: Single Duct Fan & Reheat Inputs: Discharge Air Temp, Space Temp, Setpoint, and Air Flow (BAC-8205 adds position). Analog Outputs: Analog Heat and Fan Speed. Binary Outputs: Actuator Drive Clockwise and Actuator Drive Counter Clockwise, Fan Start/Stop, Heating Stage 1, Heating Stage 2 and Heating Stage 3. BAC-8007: Dual Duct Inputs: Discharge Air Temp, Space Temp, Setpoint, Primary Air Flow, Secondary Air Flow, Primary Damper, Position, Secondary Damper position and CO2. Analog Outputs: Analog Heat and Fan Speed. Binary Outputs: Actuator Drive Clockwise and Actuator Drive Counter Clockwise, Fan Start/Stop, Secondary Actuator Clockwise, Secondary Actuator Counter Clockwise and Heating Stage/Lighting. List all BACnet Interoperability Building Blocks supported (see Annex K in BACnet 2001): DS-RP-A, DS-RP-B, DS-RPM-B, DS-WP-A, DS-WP-B, DS-WPM-B, DM-DDB-A, DM-DDB-B, DM-DCC-B, DM-DOB-B, DM-TS-B, DM-RD-B Which of the following device binding methods does the product support? (check one or more) Send Who-Is, receive I-Am (BIBB DM-DDB-A) Receive Who-Is, send I-Am (BIBB DM-DDB-B) Send Who-Has, receive I-Have (BIBB DM-DOB-A) Receive Who-Has, send I-Have (BIBB DM-DOB-B) Manual configuration of recipient device's network number and MAC address None of the above Standard Object Types Supported: OBJECT CREATABLE DELETABLE OPTIONAL PROPERTIES Analog Input No No Description, Device_Type Analog Output No No Description, Device_Type Revision A 2 of 4

Analog value No No Description, Priority_Array, Relinquish_Default Binary Output No No Active_Text, Description, Device_Type, Inactive_Text Binary Value No No Active_Text, Description, Inactive_Text, Priority_Array, Relinquish_Default Loop No No Bias, Derivative_Constant, Derivative_Constant_Units, Description, Integral_Constant, Integral_Constant_Units, Maximum_Output, Minimum_Output, Proportional_Constant, Proportional_Constant_Units Program No No Description, Description_Of_Halt, Program_Location, Reason_For_Halt File No No Description Device No No Description, Local_Date, Local_Time, Location, Max_Info_Frames, Max_Master, Multi-State Value No No Description, Priority_Array, Relinquish_Default, State_Text, Revision A 3 of 4

Data Link Layer Options (check all that are supported): BACnet IP, (Annex J) Able to register as a Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s) MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 MS/TP slave (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: Other: Networking Options (check all that are supported): Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc.: Annex H.3, BACnet Tunneling Router over UDP/IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Segmentation Capability (check all that apply): Able to transmit segmented messages Able to receive segmented messages Window Size Window Size Character Sets Supported (check all that apply): Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (ICS-4) JIS C 6226 If this product is a communication gateway, describe the non-bacnet equipment/network(s) that the gateway supports: Include any addition information about the product's BACnet capabilities relevant to interoperability: Revision A 4 of 4

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement RTU (KMC Controls BAC-8304) Application Specific Controller (B-ASC) 920-019-02A 1 of 4

BACnet Protocol Implementation Conformance Statement (BACnet Testing Laboratories Version) Date: 06-03-13 Vendor Name: KMC Controls Product Name: RTU Product Model Number: KMC Controls BAC-8304 Applications Software Version: APP1.0.10.0 BACnet Protocol Revision: 135-2008 Version:1, Revision:7 Firmware Revision: R1.0.0.3 Product Description: The BAC-8304 is an application specific direct digital control actuator (B-ASC) that provides precise monitoring and control of connected points. It is designed for the application of 2H/2C RTU with economizer and occupancy enable. It has four analog inputs, a modular connection for an STE-8001 digital sensor/interface, and six single-stage optically isolated triac outputs. List all BACnet Interoperability Building Blocks supported (see Annex K in BACnet 2001): DS-RP-A, DS-RP-B, DS-RPM-B, DS-WP-A, DS-WP-B, DS-WPM-B, DM-DDB-A, DM-DDB-B, DM-DCC-B, DM-DOB-B, DM-TS-B, DM-RD-B Which of the following device binding methods does the product support? (check one or more) Send Who-Is, receive I-Am (BIBB DM-DDB-A) Receive Who-Is, send I-Am (BIBB DM-DDB-B) Send Who-Has, receive I-Have (BIBB DM-DOB-A) Receive Who-Has, send I-Have (BIBB DM-DOB-B) Manual configuration of recipient device's network number and MAC address None of the above Standard Object Types Supported: OBJECT CREATABLE DELETABLE OPTIONAL PROPERTIES Analog Input No No Description, Device_Type Analog Output No No Description, Device_Type Analog value No No Description, Priority_Array, Relinquish_Default Binary Output No No Active_Text, Description, Device_Type, Inactive_Text Binary Value No No Active_Text, Description, Inactive_Text, Priority_Array, Relinquish_Default Loop No No Bias, Derivative_Constant, Derivative_Constant_Units, Description, Integral_Constant, Integral_Constant_Units, Maximum_Output, Minimum_Output, Proportional_Constant, Proportional_Constant_Units Program No No Description, Description_Of_Halt, Program_Location, Reason_For_Halt 920-019-02A 2 of 4

File No No Description Device No No Description, Local_Date, Local_Time, Location, Max_Info_Frames, Max_Master, Multi-State Value No No Description, Priority_Array, Relinquish_Default, State_Text, 920-019-02A 3 of 4

Data Link Layer Options (check all that are supported): BACnet IP, (Annex J) Able to register as a Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s) MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 MS/TP slave (Clause 9), baud rate(s): 9600, 19200, 38400, 76800 Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: Other: Networking Options (check all that are supported): Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc.: Annex H.3, BACnet Tunneling Router over UDP/IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Segmentation Capability (check all that apply): Able to transmit segmented messages Able to receive segmented messages Window Size Window Size Character Sets Supported (check all that apply): Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (ICS-4) JIS C 6226 If this product is a communication gateway, describe the non-bacnet equipment/network(s) that the gateway supports: Include any addition information about the product's BACnet capabilities relevant to interoperability: 920-019-02A 4 of 4