TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Similar documents
Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Waterproof. Keypad/Reader/Controller

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Single Door Standalone Access Control User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-H Waterproof Keypad/Reader/Controller

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

BC Digital Keypad. User Manual

DOLXFD1000B. Waterproof Access Control/Reader

User Manual. PCKeypad Wireless Keypad

MC61PL USER/INSTALLER MANUAL MC61-PL-3.6

HSY-S209 EM Metal waterproof access control system User Manual

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

VIDI-AC-2CS Access Controller/ Reader

Fingerprint Access Control F1. User Manual

Digital Keypad Introduction

EL-ST100 KEYPAD CONTROLLER

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Metal Standalone Keypad Access Control S100

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

DG-800 Stand-Alone Proximity Reader Instruction Manual

CC Series metal access control Manual

User Manual. Split access control with intelligent secured power supply.

Installation and User Manual

Stand-alone Proximity Access Control

VIS-3200 / VIS-3201 User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

RBR-SB-KTZ001 LAR 2. User Manual

1. Product Specification

RGB Power Batten. User Manual. Order code: EQLED032

ACCESS CONTROL SYSTEM

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

Network Camera. Quick Guide DC-B1203X. Powered by

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Crossfire. User Manual. Order code: EQLED061

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Blitzer Strobe. User Manual. Order code: EQLED366

KP2000E/EM Series Style Keypad

DC-D2212R / DC-D2212WR

_ Access control SISTEMAS DE SEGURIDAD

Blitzer RGB Strobe. User Manual. Order code: EQLED365

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

UV Power Flood. User Manual. Order code: EQLED029

Vector Beam White. User Manual. Order code: LEDJ265

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Flexoled FTP3HP RGB LED DMX Driver

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016

Slimline CW & WW Series

LTK1100 Series Card Reader User Manual

Access Control Terminal. User Manual UD.6L0206D1135A01

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

DC-D4213RX DC-D4213WRX

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

UV Spectra Batten 12 x 5W UV LEDs

Network Camera. Quick Guide DC-T3243HRX. Powered by

Network Camera. Quick Guide DC-D1223WX. Powered by

REX F-0-9 Standalone or Access Controller

FTK5 PROXIMITY KEYPAD

2000 Series e/em Style Keypad Installation and Programming Manual

GV-Card Reader. User s Manual

Standalone Access Control

RFID/Digital Access Control Keypad

Vortex. User Manual. Order code: EQLED073

MICRON DJ Booth Tri-colour Starcloth

VIS-3102 Installation Manual

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Gobo Projector XP 80W

Microbar COB System. User Manual. Order code: EQLED137

Installation guide for PR602LCD type access controller

232iLM Keypad Installation and Programming Instructions

ZF LED Zoom Fresnel. User Manual

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

PF LED Profile. User Manual

FTP1 Single Channel LED DMX Driver

GV-AS Controller. Installation Guide

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Endura 1Q120 RGBW COB Exterior Fixture

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting. Siemens AB. Version 5.0 A Security Products

GV-RK1352 and GV-R1352 Card Reader

Transcription:

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT INSTALLATION 04. PROGRAMMING QUICK REFERCE PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE USER SETTINGS DOOR SETTINGS RESET TO FACTORY DEFAULT ANTI TAMPER ALARM 06. ACOUSTO-OPTIC INSTRUCTIONS SOUNDS AND LIGHTS 07. CABLING LEAD WIRE DESCRIPTION CABLING DIAGRAM 1B 2B 2B 3A 4A 4B 6A 6B 6B 7A 7B 7A STANDARDS TO FOLLOW ATTTION: This product is certified in accordance with European Community (EC) safety standards. This product complies with Directive 2011/65/EU of the European Parliament and of the Council, of 8 June 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment. (Applicable in countries with recycling systems). This marking on the product or literature indicates that the product and electronic accessories (eg. Charger, USB cable, electronic material, controls, etc.) should not be disposed of as other household waste at the end of its useful life. To avoid possible harm to the environment or human health resulting from the uncontrolled disposal of waste, separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Home users should contact the dealer where they purchased this product or the National Environment Agency for details on where and how they can take these items for environmentally safe recycling. Business users should contact their vendor and check the terms and conditions of the purchase agreement. This product and its electronic accessories should not be mixed with other commercial waste. This marking indicates that the product and electronic accessories (eg. charger, USB cable, electronic material, controls, etc.) are susceptible to electric shock by direct or indirect contact with electricity. Be cautious when handling the product and observe all safety procedures in this manual. 1A 1B

01. SAFETY INSTRUCTIONS 02. PRODUCT STANDARDS TO FOLLOW It is important for your safety that these instructions are followed. Keep these instructions in a safe place for future reference. The ELECTROCELOS S.A. is not responsible for the improper use of the product, or other use than that for which it was designed. The ELECTROCELOS S.A. is not responsible if safety standards were not taken into account when installing the equipment, or for any deformation that may occur. The ELECTROCELOS S.A. is not responsible for insecurity and malfunction of the product when used with components that were not sold by the them. This product was designed and manufactured strictly for the use indicated in this manual. Any other use not expressly indicated may damage the product and/or can cause physical and property damages, and will void the warranty. Do not make any changes to the automation components and/or their accessories. The customer shall not, under any circumstances, attempt to repair or tune the automatism. Must call qualified technician only. The installer must have certified professional knowledge at the level of electronic. He should also be able to perform electrical connections in compliance with all applicable regulations. The installer should inform the customer how to handle the product in an emergency and provide him the manual. This device can be used by children 8 year old or older and persons whose physical, sensory or mental capacities are reduced, or by persons without experience or knowledge if they have received supervision or instructions on the use of the device in a safe manner and understood the hazards involved. Children should not play with the device. Cleaning and maintenance by the user must not be carried out by unsupervised children. Automatism powered by very low safety voltage, with electronic board/control board/control unit. Before installing, the installer must verify that the temperature range indicated on the automatism is appropriate to the location of the installation. In order to protect the electrical cables against mechanical stress, you should use conduit for the electrical wires, essentially on the power cable. PRODUCT PROFILE The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards,13.56mhz Mifare cards. The unit has many extra features including lock output current short circuit protection, Wiegand output, and a backlit keypad. These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. TECHNICAL PARAMETERS Waterproof, conforms to IP68 Strong Zinc Alloy Electroplated antivandal case Full programming from the keypad 2000 uses, supports Card, PIN, Card + PIN Can be used as a stand alone keypad Backlight keys Wiegand 26 input for connection to external reader Wiegand 26 output for connection to a controller Adjustable Door Output time, Alarm time, Door Open time Very low power consumption (30mA) Fast operating speed, <20ms with 2000 users Lock output current short circuit protection Easy to install and program Built in light dependent resistor (LDR) for anti tamper Built in buzzer Red, Yellow and Green LEDS display the working status Work Voltage ac&dc 9-28V Static Current Reading Range Capacity Ambient Temperature <30mA 3-8cm 2000 users -25~55 C Ambient Humidity 10% ~ 90% Electricity lock output <3A Alarm output <20A Output short circuit protection time Open time <100μS 0 ~ 99 seconds (adjustable) 2A 2B

03. INSTALLATION PRODUCT INSTALLATION 03. INSTALLATION PRODUCT INSTALLATION Caption A TEC100 B Drilling diagram C Hex key D Screws E Bushings BUSHING SCREW 88mm 27mm 122mm 3 Using the hex key (C), loosen the screw in totality and remove the back cover. 4 Insert the bushings, place the back cover and tighten totally the screws. F G F 1 Apply the drilling diagram (B) to the desired installation place. 2 Make the holes: F - TEC100 fixing holes; G - hole to pass the cable. 5 Insert the cable into the hole. 6 Attach the body of the TEC100 to the back cover, insert the screw and tighten completely. 3A 3B

04. PROGRAMMING QUICK REFERCE PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE USER SETTINGS To enter the To exit from the programming mode * Master code * Master code To enter the 999999 is the default factory master code 999999 is the default factory master code Note that to undertake the following programming the master user must be logged in To change the master code To add a PIN user To add a card user To delete a PIN or a card user The master code can be 6 to 8 digits The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting * Read card Cards can be added continuously without exiting Users can be deleted continuously without exiting To unlock the door for a PIN user Enter the PIN then press To unlock the door for a card user 2 User ID number 2 Read card * 0 New code New code 1 Use ID number PIN Present the card for PIN user or for a card user To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code Setting the working mode: Set valid card only users Set valid card and PIN users Set valid card or PIN users To add a user in either card or PIN mode, i.e. in the To add a PIN user To delete a PIN user The master code can be 6 to 8 digits long 3 2 3 1 3 Entry is by card only Entry is by card and PIN together Entry is by either card or PIN (default) 3 2 * 0 New code New code mode. (Default setting) 1 User ID number PIN The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode as follows: 1 User ID no 1 PIN User ID no 2 PIN 2 User ID number Users can be deleted continuously without exiting 0 To change the PIN of a PIN user (This step must be done out of ) * ID number Old PIN New PIN New PIN 4A 4B

05. DETAILED PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE USER SETTINGS To add a card user (Method 1) This is the fastest way to enter cards, user ID number auto generation To add a card user (Method 2) This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card To add a card user (Method 3) Card number is the last 8 digits printed on the back of the card,user ID number auto generation To add a card user (Method 4) In this method a User ID is allocated to a card number. Only one user ID can be allocated to the card number To delete a card user by card. Note users can be deleted continuously without exiting To delete a card user by user ID. This option can be used when a user has lost their card To delete a card user by card number. This option can be used when the user want to make the change but the card has lost To add a card and PIN user in card and PIN mode ( 3 1 ) 1 Read card Cards can be added continuously without exiting 1 ID number User can be added continuously without exiting 1 Card number User can be added continuously without exiting 1 ID number User can be added continuously without exiting 2 Read Card 2 User ID 2 Card number Read card Card number Note users can be deleted continuously without exiting USER SETTINGS To Add a card and Pin user (The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved.) To change a PIN in card and PIN mode (Method 1) Note that this is done outside so the user can undertake this themselves To change a PIN in card and PIN mode (Method 2) Note that this is done outside so the user can undertake this themselves To delete a Card and PIN user just delete the card To add a card user in card mode ( 3 0 ) To Add and Delete a card user To delete All users To delete ALL users. Note that this is a dangerous option so use with care To unlock the door Add the card as for a card user Press * to exit from the Then allocate the card a PIN as follows: The operating is the same as adding and deleting a card user in 3 2 For a PIN user Enter the PIN then press For a card User * Read card 1234 PIN PIN * Read card Old PIN New PIN * ID number Old PIN New PIN 2 User ID 2 0000 Read card New PIN New PIN 1 For a card and PIN user Read card then enter PIN 5A 5B

05. DETAILED PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE DOOR SETTINGS DOOR SETTINGS Relay Output Delay Time To set door relay strike time 1 ID number Read card 0-99 is to set the door relay time 0-99 seconds Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is forced open, or if the door is opened after 20 seconds,the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the default being 1 minute. To remove the alarm To reset the Door Forced Open warning To reset the Door Open Too Long warning RESET TO FACTORY DEFAULT Read valid card Close the door or or Read valid card or Master Code Master Code To disable door open detection. (Factory default) 6 0 1 Disconnect power from the unit 2 Press and hold key whilst powering the unit back up 3 On hearing two Di release key, system is now back factory settings To enable door open detection 6 1 Please note only installer data is restored, user data will not be affected Alarm output time To set the alarm output time (0-3 minutes) Factory default is 1 minute 5 0~3 ANTI TAMPER ALARM Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes, depending on the option selected below. The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. Normal status: No keypad lockout or alarm (factory default) 7 0 (Factory default setting) Keypad Lockout 7 1 Alarm and inside buzzer operate 7 2 6A 6B

06. ACOUSTO-OPTIC INSTRUCTIONS SOUNDS AND LIGHTS OPERATION STATE RED LIGHT GRE LIGHT BUZZER NOTE Standby Slow flashing Off Buttons Success Off On Di Failure Di Di Di Di Into programming On Off Di Set condition On On Exit programming Slow flash Off Di Unlock Off On Di Alarm Fast flashing Off Alarm sound 8 Indicator is orange 07. CABLING LEAD WIRE DESCRIPTION Line sequence Marks Color Function description 1 BELL_A Pink Doorbell button one end 2 BELL_B Pale blue The doorbell button to the other end 3 Green WG output line 4 White WG output line 5 ALARM Grey 6 OP Yellow 7 D_IN Brown Alarm negative (alarm positive connected + 12 v Exit button one end (Exit button the other end connected GND) Magnetic switch one end (magnetic switch another end connected GND) 8 AC&DC Red Power supply 9-28V input (DC input+) 9 AC&DC Black Power supply 9-28V input (DC input -) 10 NO Blue Relay NO 11 COM Purple Relay common 12 NC Orange Relay NC 7A 7B

07. CABLING CABLING DIAGRAM Ordinary power supply cabling diagram Access control power supply cabling diagram Operating as a wiegand output reader In this mode the unit supports a wiegand 26 bit output so the wiegand data lines can be connected to any controller supports 26 bit input. Metalpassword access controller BELL_A BELL_B ALARM OP D_IN AC&DC+ AC&DC- NO COM NC GND Pink Wathet blue Green White Gray Yellow Brown Red Black Blue Purple Orange Shiedlding layers Bell - Alarm + Exit button Door magnetic switch Positive electronic lock Negative electronic lock Power - 12V + +12V GND Access control Metalpassword access controller BELL_A BELL_B ALARM Pink Wathet blue Green White Gray Bell - Alarm + +12V Access control BELL_A OP Yellow Exit button GND OP Yellow Door D_IN Brown D_IN Brown magnetic Positive switch - + AC&DC+ Red electronic +12V Red 12V lock AC&DC- Black GND Black GND Negative - + NO Blue electronic NO Blue lock COM Purple COM Purple NC Orange NC Orange Shiedlding GND layers Connect 12Vdc/3A NO COM NC 12V GND PUSH BELL_B ALARM Pink Pink Green White Gray 8A8