MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

Similar documents
DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

iologik E1200H Series

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

DIN Rail RTU 540CMD01 Data sheet

General Operating, Maintenance and Installation Manual

Sauter Systems

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

Feature and Benefits. Certifications

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Webdom Datalogger 1.5

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

3U 19-inch IEC native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU. Features and Benefits. Certifications

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

2.4. LinPAC-8000 Series

APP 700 Technical Specification

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

Part Numbers SNAP-PAC-S1 SNAP-PAC-S2

HEC. General Operating, Maintenance and Installation Manual

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

Mega_Link Telemetry Communication System

MESR9xx. Vlinx Industrial MODBUS Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

TALON Network Manager- 2 & 6 Express

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

TM241CE24U controller M IO transistor NPN Ethernet

M-Bus Central Unit. Use

Modbus TCP/RTU Gateway

GCU401. Technical specification

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

LMC058LF42 compact base - 42 I/O - 24 V DC supply

ZLJ\YP[`7YVIL, :[HUKHYK

TM221CE40R controller M IO relay Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

XBTGT1335 advanced touchscreen panel x 240 pixels QVGA - 3.8" - TFT LCD - 24 V DC

TELETERM M2 Series Programmable RTU s

Communication Gateway COM 610. Product Guide

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

TM241CE40T controller M IO transistor PNP Ethernet

TM258LD42DT4L compact base M I/O - 24 V DC

IntesisBox Modbus Server Panasonic

DTM Distributed Transmitter Monitor

JetBox 9300/9310 User Manual. Hardware

Asset Management. Facility Management. Total Solutions. Supply Chain Management. Utilities. Series 4500

modunet292: novanet-ethernet interface

IMIO100 IMIO105. DDC controllers. Summary

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

TM241CE40R controller M IO relay Ethernet

Modbus Server SIEMENS Algorex (printer port)

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

mark150s mark150/485s DDC controllers Summary

TM221ME16T controller M IO transistor PNP Ethernet

IntesisBox Modbus Server - Honeywell XLS 80

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TM258LF42DT compact base M I/O - 24 V DC - CANopen

MGate 5105-MB-EIP Quick Installation Guide

TM241CE24T controller M IO transistor PNP Ethernet

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

MGate 5111 Quick Installation Guide

TM241CE40R controller M IO relay Ethernet

ABLELink. Modbus Gateway MB5000 Series User s Manual

AC 800M for Compact Product Suite Outline of all modules

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

XBTGT6330 advanced touchscreen panel x 600 pixels SVGA " - TFT LCD - 24 V DC

TM221M32TK controller M IO transistor PNP

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

TM251MESC controller M251 Ethernet CAN

RM6000 GPRS Modem / Router

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description

TM221CE24T controller M IO transistor PNP Ethernet

W315 - W320 remote management modules

XP-8346-CE6 XP-8346-CE6-PRO

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

SA2WEB24. Central unit module. Benefits. Description

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

XBTGT4340 advanced touchscreen panel x2 40 pixels QVGA - 7.5" - 24 V

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

XBTGT6340 advanced touchscreen panel x 600 pixels SVGA " - 24 V

Technical specification Marine Master Clock

TG Technical specifications

IQ21x Series Controllers

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DT Desktop Series

Features and Benefits. Certifications

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

Compact, fanless, vibration-proof computers for rolling stock applications. Features and Benefits. Certifications

TM221M16TG controller M IO transistor PNP spring

RTU32S RTU32S Series Small Compact Utility RTU

Transcription:

MM-IM Large works automation And data gateway. PRODUCT DATASHEET The MM-IM is a Remote Telemetry Unit (RTU) that provides a wide range of interfaces and protocols to allow integration with any typical site equipment to facilitate a single point for site supervisory control and data acquisition.. Key Functionality Full telemetry support including alarm handling and reporting, current values and trending. Support for a range of open standard communications protocols. (Modbus, DF1 Master & Slave, Ethernet IP, Flex/Point IO and LSI) Support for IEC61131 programs using Straton workbench. Linux based. HARDWARE FEATURES Support for over 4,000 IO points. Four serial ports, two USB ports and two Ethernet ports allow for multiple IO and communication options. Configurable using either Straton or MicroMC. Remote configuration via Straton or Data Gatherer. IO points support for 1024 digital inputs, 256 analogue inputs and 256 counter inputs. Counter inputs can be configured to detect digital pulses or can record register information from intelligent sensors. The MM-IM has support for 1024 digital outputs and 256 analogue outputs. Serial ports the MM-IM has 4 proprietary RJ45 serial ports for which a number of custom cables are available. By default all are RS232 ports; one (COM4) may be configured as an RS422/RS485 port. USB ports the MM-IM has 4 USB ports that may be used to manually mount flash devices. Ethernet ports Two onboard Ethernet ports enable communications to either a master station or onsite distributed IO. Memory The MM-IM has 512 Mbytes of solid-state memory for local storage of trend and alert data, equivalent to approx. 10 million samples (for example, approx. 1 year s storage at a sampling rate of 30 analogue values per minute). FIRMWARE FEATURES sensor collection storage processing interaction Input Processing Independent configurable processing of all input sources, including calibration and filtering of analogue sensors, inversion and debounce of digital sensors. Output Processing - Independent configurable processing of all outputs, including scaling, inversion, and programmable pulse widths. Trending and alerts Independently configurable periodic and event based recording of any data source in any combination. Independently configurable alarm and event detection, timestamping and recording on any input source with extensive alarm reduction functionality, including time and level deadbands. Dialback over IP or PSTN can be configured on alarm. IEC61131-3 programming support for all five standard languages through the use of the Straton runtime engine. Configuration Download and non-volatile storage of static configuration data, including communications settings, modem controls, dialback phone numbers, alarm and event thresholds and time deadbands.

SERIAL PORTS AND SUPPORTED PROTOCOLS The MM-IM has four serial ports provided by RJ45 sockets. It also has two RJ45 Ethernet ports and four USB ports The MM-IM supports a number of protocols using its 4 serial ports, using both RS232 and RS485; Modbus The MM-IM can act as a Modbus master or slave over TCP and serial (RTU). DF1 The MM-IM acts as a DF1 master mapping IO values to Medina points to report to the DG. Ethernet IP the MM-IM supports; scanner, adapter, Rockwell tag client, Rockwell Point/Flex IO scanner) Medina the MM-IM supports the full Medina slave functionality for reporting to the DG, as well as support for communicating with IO using LSI and DSM. The Ethernet ports can be used to connect the MM-IM directly to an existing network. STATUS INDICATORS There are four green LED status indicators on the front of the unit: LED STATUS Meaning Power On Unit powered on System LAN1 LAN 2 On quickly slowly ON ON Unit booting Firmware upgrade in progress Normal operation First Ethernet port active Data transfer in progress Second Ethernet port active Data transfer in progress 8 red LEDs indicate the status of the respective serial ports, showing data received and transmitted:

DIL SWITCHES The MM-IM has eight DIL switches mounted on the front of the enclosure. These switches determine any special start-up actions it must perform (e.g. default configuration) and its final operating mode. Switches 6-8 configure settings for COM4. Refer to the MM-IM Remote Telemetry Unit User Guide for a detailed description of the operation of these switches. O N 1 2 3 4 5 6 7 8 WEB PAGE RS422/485 Termination/Bias Resistors: S7 S8 Off Off - Disabled Off On - Disabled On Off - 120Ω Termination & 680Ω Bias On On - 120Ω Termination 2/4-Wire Mode (COM4): On- 4-Wire (Typically RS422) Off- 2-Wire (Typically RS485) Virtual Terminal On- Enabled (COM1) Off- Disabled Reset Control On- Held Reset Off- Normal running Reserved Boot Mode On- Load Firmware Off- Run Clean Configuration On- Enabled Off- Disabled The MM-IM has a built-in Web Server that is capable of serving up a page with read-only access to the current configuration files. This provides an easy way to view the configuration on the MM-IM, although it will require some familiarisation with the configuration files To access the page, simply browse to the MM-IM s IP address in a Web browser. Refer to the MM-IM Remote Telemetry Unit User Guide for further details. ACCESSORIES The following accessories are available for the MM-IM MM-IM Mk4 Modbus RS485 cable MM-IM Mk4 to Modem RS232 cable MM-IM MK4 to Mitsubishi QN D Type cable MM-IM MK4 to Alan Bradley DF1 Type cable MM-IM MK4 to PC cable MM-IM MK3 RS485 to Modbus RJ45 converter cable MM-IM MK3 RS232 to RJ45 converter cable MM-IM Backplane (backwards compatible) Various GSM/GPRS and PSTN Modems Contact info@metasphere.co.uk for further information

SPECIFICATIONS Power supply Serial Communications Interface USB ports Ethernet ports Processor Memory LEDs Real Time Clock Enclosure Mounting Build options Unit size Unit weight 8-30VDC Typical Current consumption: 0.29A @ 12V, 0.16A @ 24V. Inrush Current: 1.0A @ 12V, 2.2A @ 24V. 3 x RS232 serial ports configurable up to 115200 bps 1 x RS485 serial port configurable up to 115200 bps All support RTS and CTS modem control lines. COM1 additionally supports DCD, DTR, DSR and RI. Four USB 2.0 Master ports 2 x IEEE 802.3 10BASE-T and 100BASE-TX interfaces ICOP Vortex86SX SoC CPU-300MHz. Onboard 128MB DDR2 SDRAM 512 Mbytes solid state disk module Four pairs of red (Rx) and green (Tx), one pair per serial port. Plus four green status LED s as follows: Power, indicates power is present System, used to indicate overall system status LAN1, used to indicate Ethernet activity LAN2, used to indicate Ethernet activity Real time clock with Lithium Battery Backup. BS EN 60529 IP20 ingress protection Supplied with 2 DIN rail clips on rear of enclosure as standard Available with standard and inverted overlay options. 175 120 50 mm (excluding connectors) 0.45 Kg (approx)

APPROVALS The product is designed to hold a CE declaration of conformity in accordance with Council Directive 2004/108/EC Electromagnetic compatibility and 2001/95/EC General Product Safety. The product complies with the following standards: EMC: EN61010-1:2001 Safety requirement for electrical equipment for measurement and control EN55022:2006 +A1:2007 Class A Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement EN55024:1998+A2:2003 CISPR 24:1997 Information technology equipment. Immunity characteristics. Limits and methods of measurement Safety: EN-61010-1 Safety requirement for electrical equipment for measurement and control Environmental Operating temp.: -10 to +55 C Humidity: 5% to 95% non-condensing Ingress protection: BS EN 60529 IP20 Metasphere provides robust asset monitoring of time critical remote operations for operators to gain competitive advantage and meet regulatory compliance. Metasphere Limited Millfield Dorking Road Tadworth Surrey KT20 7TD t: +44 (0) 1737 846 100