USB RS-485/422 Communication adapter virtual serial port ELO E216. Operation manual

Similar documents
USB RS-485/422 Communication adapter virtual serial port ELO E211. Operation manual

USB RS232 Communication adapter virtual serial port ELO E215. Operation manual

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

PCI Express 4-Port Industrial Serial I/O Cards

USB to RS-485/RS-422 Interface Converter. User Manual

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications

SB485. USB-RS485/422 converter. Isolation. Virtual serial port

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

Windows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

Windows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter

Commercial-grade Interface Converter User Manual

W&T Manual Interface modules W&T

3.1 I-7560 Pin Assignment and Specifications: Introduction

I-7570 Serial To HART Converter

USB to Single RS-422/485 Adapter - with optical isolation and surge protection (USB-COMi-SI)

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Manual Industry Interfaces

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

User s Manual Printed Sep Rev 1.2

ICF-1150 Series Quick Installation Guide

DATA CONNECT ENTERPRISE

TRANSDUCER T4311, T4411

Manual Fiber Optic Interfaces

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

MODEL USB-COM-2SM USER MANUAL

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

TCF-142 Quick Installation Guide

MED102A. Industrial Serial to Single-mode Fiber Converter

CONNECT WITH RELIABILITY. USB-to-Serial Adapter User s Manual

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

Integrity Instruments Application Notes. Release 1

Serial Communication Converters & Adapters Instruction Manual

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

ICF-1150 Series Quick Installation Guide

USB-COM Plus ISO (USB-COMi SI-M)

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

ADA-I9140. User manual ADA-I9140. USB to RS-485 / RS-422 converter. 1 io_ada-i9140_v3.24_en. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

EasySYNC Ltd. USB to Serial Converters Manual

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

T2314, T2414. Instruction Manual

SER-4485-SI-M USER S MANUAL

General Specifications. P2-SCM Serial Communications

USB to RS-422/485 Serial Adapter

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

MEV Limited USB232/485 INSTRUCTION MANUAL

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

RS-485 module. Data sheet. for electricity meters

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

TRP-C08 User s Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

EasySYNC Ltd. USB to Serial Converters Manual

JetCon 1100 / User s Manual. USB to Serial Converter series. Version 1.0

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

ISOLATED RS-232 TO RS-422/485 CONVERTER

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

RS-422/485 PCIe Card

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

TCF-142-RM Series Hardware Installation Guide

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

USB to RS-422 / 485. US USB To Serial Operation Manual

ADAM Fiber Optic to RS-232/422/485 Converter

T2314, T2414. Instruction Manual

TRP-C06H User s Manual

FlexMulti Setup Guide

R507 I.S. Interface Module User Manual

ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Industrial Media Converters

P3-SCM. General Specifications

MIKROPROCESORY PRO VÝKONOVÉ SYSTÉMY. Serial Data Transmission (Stručný přehled) České vysoké učení technické Fakulta elektrotechnická

USB RS485/RS422 Converter INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8

RS485 3 click. How does it work? PID: MIKROE-2821

FL MC 2000E (SM40) LC

Transcription:

USB RS-485/422 Communication adapter virtual serial port Virtual IDLE ECHO ON OFF COM to Fiber Optics through USB ELO E216 Operation manual

1.0 Introduction...3 1.1 Use of the adapter...3 2.0 Operation principles...3 3.0 Installation...3 3.1 USB interface connection...3 3.2 RS-485 Installing...4 3.3 RS-422 Installing...4 3.4 Importance of terminators...4 3.5 Ground potentials differences elimination...5 3.6 Adapter setting...5 3.7 Installing driver...6 3.7.1 Installing virtual port under Windows XP...6 3.7.2 Uninstalling virtual port under Windows XP...11 3.7.3 Virtual port properties setting...12 4.0 Specification...13 4.1 Parameters...13 4.2 Other...13 5.0 Testing...13 6.0 Troubleshooting...14 7.0 Ordering information...14 2

3 ELOE216ZKE001 1.0 Introduction The USB interface is preferred to the COM port with RS-232 interface in personal computer technology. To connect the peripheral devices of the RS-232 interface, the USB/RS-232 adapters along with the driver are applied to create so-called virtual COM on the PC. ELO E216 is a device which converts virtual COM to the asynchronous line of the symmetric signal via the USB interface. The signals transmission to the duplex RS- 422 interface allows the range and the transmission interference immunity to increase. The signals transmission to the half-duplex RS-485 interface allows the range, communication partners number and the transmission interference immunity to increase. 1.1 Use of the adapter The converter increases transmission immunity against electrical disturbance and isolates both interfaces USB / RS-422 hence it is intended to be used in the environments where lightning over-voltage is not necessary to be considered. To lead the RS-422 link cable outside buildings, it is necessary to provide additional overvoltage protection on the input points. The adapter allows the transmission rate up to 1 Mbps. This maximum attainable rate decreases due to the line length and/or its impedance growth. Recommended maximum line length is 1200 m at the rate of 9600 bps. 2.0 Operation principles The adapter converts the RS-422 or RS-485 interface to the USB interface, transmits TxD and RxD signals. The RS-485/422 interface is taken out onto the clamps. RS-485 interface is used to the communication of up to 32 partners in one twisted pair. The transmission is half-duplex that means switching on the RS-485 transmitter only during its own transmitting to allow other communication partners to transmit. RS-422 interface is mainly designed for two devices communication in the duplex mode. As transmission media there are two twisted pairs, each for one transmission direction. The adapter also supports the MULTIDROP mode where the transmitter may be switched off as with RS-485. In this mode, one partner as the MASTER can communicate with up to 31 other partners operating as the SLAVE. 3.0 Installation E216 adapter installation is described in this part. There are two problems to be solved: the hardware installation and the SW driver installation. 3.1 USB interface connection The adapter operates as per specification USB 2.0 full-speed (12 Mbps). The USB adapter connector is of B female type. The adapter is connected to the terminal equipment via the USB jumper cable of AB type.

3.2 RS-485 Installing The TxRx+ and TxRx- clamps are used to connect the adapter to the bus. The adapter has to be set to the RS-485 mode via the No.1-switch in Off position. The RS-485 line should be terminated with the 100-120Ω resistors on both ends. The reasons in more details are given in the 3.4 chapter. The external terminator (the resistor between TxRx+ and TxRx conductors) or the internal one the No.3-switch in On position may be used. If the active termination is used (see the 3.4 chapter), it is necessary to place one resistor between TxRx+ and SP(+5V) clamps and one 820Ω resistor between TxRxand SG (signal ground) via the internal active terminator using the 5 and 6 switches in On position. 3.3 RS-422 Installing In case of the point-to-point connection, the TxRx+ (TxRx-) clamp of the local adapter is necessary to be connected to the Rx+ (Rx-) clamp of the remote adapter and the Rx+ (Rx-) clamp of the local adapter to the TxRx+ (TxRx-) clamp of the remote adapter. The 1-switch has to be in On position, thus RS-422. The point-to-point duplex connection of the maximum rate that can be of up to 1 Mbps on the short line is carried out this way. For the MULTIDROP transmission system, it is necessary to distinguish if the adapter works in the MASTER or SLAVE mode. The TxRx+ (TxRx-) of the MASTER adapter is connected to the Rx+ (Rx-) clamps of all SLAVE adapters. The Rx+ (Rx-) clamps of the MASTER adapter are connected to the TxRx+ (TxRx-) clamps of all SLAVE adapters. The No.1switch of all adapters has to be in 422 position. The No.2 switch as the MASTER is On (Normal ), as the SLAVE is set to the Off position ( Multidrop ). 3.4 Importance of terminators The RS-422 recommendation (V.11) uses the symmetric signal transmitted via the twisted pair, there are various marks of the single wires: A-B, P-N, + - and the like. On the long lines there it is necessary to suppress the echo and the electromagnetic interference so the 100-120Ω resistors (so-called passive terminators) placed between A-B wires on the link ends are applied. The RS-485 recommendation uses the same symmetric signal as the RS-422 hence it requires the use of the passive terminators as the RS-422. On the RS-485 link, another state is defined when no communicating partner transmits all are of the high impedance state and just listening. The partner differential receiver interprets the difference U A -U B. The receiver interprets the obtained signal as U A U B > 200 mv as log 1 or log 0. In the described still state, so-called IDLE, no communicating partner transmits so U A - U B < 200 mv. The problem is how to interpret the state (so-called the third) in the 4

two-state logic. The active terminator (may be only one in each section) gives the signal U A U B >200mV into the idle state line and it is interpreted as IDLE in the two-state logic. The RS-422 MULTIDROP operation with the signal third state is similar to the RS- 485 hence the active terminators are used in this mode, too. 3.5 Ground potentials differences elimination The symmetric signal can deal with the cases when the signal ground potentials difference at the connection points of the partners differs by 5-7V. To eliminate influence of the ground potentials differences, the third conductor is used (see the Fig.). 100 Ω resistors are needed in this case to eliminate currents resulting from the ground potentials differences. The signal ground clamp (labeled SG) may be used to this effect. 3.6 Adapter setting The mode switch is necessary to set to use the adapter in the situations mentioned above. First two switches (SW1, SW2) are used to the transmission mode setting the rest four switches place the terminators. 5

Mode SW1 SW2 RS-485 OFF -- MultiDrop ON OFF RS-422 ON ON Termination SW3 SW4 SW5 SW6 Without terminators OFF OFF OFF OFF Passive terminator between TxRx+ and TxRx- ON OFF OFF OFF Active and passive termin. on TxRx+and TxRx- ON OFF ON ON Passive terminator between Rx+ and Rx- OFF ON OFF OFF The switching automatics implemented into the USB 485/422 converter switches on the transmitter before the start bit transmission of a bit set-up time and switches off after the stop bit finish of a bit delay. 3.7 Installing driver The E216 adapter may be applied on the PC computers under the MS Windows 98/Me/2000/XP or Linux operating systems. The drivers are supplied together with the other files at the installation CD. They may be downloaded from the producer websides www.elo.cz. The proper installation of the drivers is indicated via the lit READY indicator on the cover connected to the adapter. Following part of the user manual describes the process of installing under MS Windows XP only. 3.7.1 Installing virtual port under Windows XP 1. When the PC turned on and the adapter connected to the USB port via the cable is detected the operating system reports a new hardware has been found: 6

2. The system runs the Add New Hardware Wizard automatically. Failing this, the Control panel may be used to start the Wizard. Select the third option in the Wizard menu - Ne, nyní ne ( No, not now ) and click the button Další ( Next ): 3. Select the second option in the Wizard menu Instalovat ze seznamu či daného umístění ( Install from a list or specific location ) and click Další ( Next ): 7

4. In the next Wizard menu select Při hledání zahrnout toto umístění and by the help of button Procházet ( Browse ) select the directory e216_drivers on the supplied CD. Then click Další ( Next ): 5. Don t be worry if the Wizzard will write: Warning and click Pokračovat ( Continue ): 8

6. Now click Finish in the dialog box of the installing device completion. ELOE216ZKE001 7. Then it is necessary to continue with the virtual port installation. System will write New hardware found again and the installation is running the same way as shown in steps from 2 to 4: 9

8. When the correct drivers of virtual COM port are found a new Warning is displayed. Click Pokračovat ( Continue ): 9. The virtual COM port installation has been completed: 10

10. Nalezen nový hardware ( New hardware found and prepared for use ): 3.7.2 Uninstalling virtual port under Windows XP 1. Select the part Add or remove programs from Control panels. Then select the row E216 RS422/485-USB Adapter. Press button Change or remove and confirm by pressing Yes. Adapter and its drivers are uninstalled: 11

2. Pressing button OK you ll confirm uninstalling: 3. After the uninstalling the LED READY will switch off. Adapter E216 can be disconnected. 3.7.3 Virtual port properties setting When connection is established the adapter virtual port appears as the next COM port in the Device Manager. Go to Control panel and select System / Hardware and run the Device Manager. The next COM called USB 485/422 Serial Port has appeared among the Ports. In Properties, its setting, e.g. transmission speed, character format and/or flow control can be changed. Caution!!! The control signals are not transmitted hence no hardware flow control can be used. The port number assignment (e.g. COM3, COM4,) may be changed under the Specify option. 12

Important! ELOE216ZKE001 If application SW doesn t use the operating system services, a correct cooperation between application SW and adapter can t be warranted! 4.0 Specification 4.1 Parameters USB interface USB connector RS-422, RS-485 connector Communication mode Isolation between USB/RS4xx Transmission mode Maximum data rate 4.2 Other Supply Power take-off Weight Dimension: Width Length Height Stocking temperature Working temperature Humidity USB 2.0 full-speed (12 Mbps) B type clamps full duplex, half-duplex isolation barrier of 1 kv for 1 sec asynchronous, duplex/half-duplex 921 600 kbps from USB interface up to 100mA (Low power) circa 75 g 55 mm 65 mm 20 mm - 10 o to +55 o C + 0 o to +50 o C 0 85% (non-condensing) 5.0 Testing When the USB cable is connected and the drivers are installed properly the LED READY has to light up. When the transmitter and receiver clamps are interconnected (TxRx+ to Rx+, TxRx- to Rx-) and 422 mode set to No.1 switcher the transmitted and received data has to be equal. The Hyperterminal program which is of the MS Windows part or E216_test supplied on the installation CD may be used for testing. The TxD and RxD LED diodes blink during the transmission. If there is the transmission of the high rate and the data blocks are very short the LED brightness is low because they only shine if the data signal is on the active level. It means the short data transmission (or even a sign transmission) of the high data rate are not perceptible to the eye. To connect TxRx+ to Rx-, TxRx- to Rx+ clamp in the 422 mode, the correct operation in the idle state can be checked. Thus we create the transmitter signal negation for the receiver and the RxD diode has to light up. 13

6.0 Troubleshooting Symptom Adapter does not work after installation Connection in normal operation quit working. The 485-USB adapter is missing in the Device Manager Action Check if the metallic link and the USB cable are connected properly Check the mode switches position. Check if the terminators are set properly. Check if READY is alight. Check if READY is alight. Check the cables connection. Turn it off and on. If need be, repeat the installation. 7.0 Ordering information Supply code is ELO E216. The adapter is supplied with the installation CD. The USB cable of the required length can be ordered separately as it is not provided. 14

15 ELOE216ZKE001