AS-interface Network Card

Similar documents
FieldLink process networking

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Series 3730 Electropneumatic Positioner Type

VALVE ACCESSORIES & CONTROLS V100 POSITIONER VAC V100 SERIES POSITIONER SIMPLE DURABLE RELIABLE

CURRENT TO PROFIBUS PA CONVERTER

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Series 3730 Type Electropneumatic Positioner

Type i2p-100 Electro-Pneumatic Transducer

General Specifications

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

General Specifications

PROFIBUS-PA Positioner Type 3785

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

FLEX Ex Spring Clamp Terminal Base

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

Dräger Polytron 8200 Stationary gas detector (CatEx)

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Fisher i2p-100 Electro-Pneumatic Transducer

DVC2000 Series FIELDVUE Digital Valve Controllers

JM - Junction Enclosure Modules for Communication Networks

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

SIY. Features. PC-Programmable Signal Isolator/Converter

Level-Lance Model 5400A

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

5 Fieldbus Technology

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Rotary Measuring Technology Absolute encoders, Multiturn, DeviceNet

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK

Smart Wireless THUM Adapter

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Valtek Logix Series Digital Positioner

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

3420 Fieldbus Interface Module (FIM) Contents

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown.

D3 Digital Positioner. PMV D3 Digital Positioner Product Information. A Flowserve Company

Installation & Operation Manual

4110 HART Level Encoder

Rosemount 248 Wireless Temperature Transmitter

PCG550, PCG552, PCG554

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

SCADAPack Modbus multivariable transmitter

Temperature process values at a glance

BA505C 2-wire 4/20mA manual setpoint station Issue 6

IHP24. Intelligent Hydraulic Positioner D HP- PL

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

2900 Float & Tape Transmitter

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Sensor boxes SRBG Key features

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Digital electropneumatic Process Controller

Pneumatic Control/Feedback

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Submersible Liquid Level Transmitter Series: PT-500

Series 3730 Type Electropneumatic Positioner

Intellis Network Control Monitors

SFY Functional Safety Frequency-to-DC Transmitter with Display

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

CHRONOS IDP INTEllIGENT DIGITAl POSITIONER FOR CONTROl VAlVES

Control Head for the integrated mounting on process valves

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Data Sheet T EN

Flow Measurement SITRANS F M

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Electropneumatic Positioner Type and Type with HART communication

S-series Foundation Fieldbus I/O

Micro Motion Model 2400S Transmitters with MVD Technology

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Electro-Magnetic Flowmeters Converters

Series ULT Ultrasonic Level Transmitter

SX90 Process Controller

Type 330SA High-Performance Electric Actuator

Intrinsically Safe Barriers

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Inductive sensor BI5-EM18-Y1X-H1141

SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Pneumatic Control/Feedback

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

Transcription:

AS-interface Network Card AS-interface certified Fully encapsulated electronic module Bus powered inputs & outputs Two built-in sensors for OPEN/CLOSE detection Short circuit protection for inputs and outputs LEDs for visual indication: - OPEN/CLOSE - Solenoid output - Bus communication - Faults EMC certified (per stds. EN61000-6-2, EN61000-6-4) Visual Diagnostics OPEN POSITION: Yellow LED BUS STATUS: Green LED CLOSED POSITION: Yellow LED SOLENOID: Red LED BUS FAULT: Red LED ASCO is designed for monitoring and controlling the position of valve actuators via AS-interface V2.1. The AS-interface Network Card is fully encapsulated for superior environmental protection and features plug-in terminal blocks for easy maintenance, built-in sensors for OPEN/CLOSE detection, and LEDs to provide visual status of network connection and actuator position. Our network cards operate with our NR and VR series rotary or HS series linear indicators. Enclosure types range from NEMA 4, 4X to Class 1, Division 1, Groups B, C & D. Accessories such as a Network Junction Box are available. Note: ASCO recommends using 24 VDC pilot valves with AS-interface cards. Technical Specifications Maximum Distance Physical Media Maximum Nodes Available I/O Network Topology Baud Rate 100m (330 ft) Two-wire cable 62 2 inputs, 1 output 4 inputs, 2 output (includes 2 general purpose input) Bus, Tree, Star 167 Kbps Ordering Number Example: VR7C2YAW0 A AJ = ASI 2x1, Version 2.1, standard addressing, 31 slaves AL = ASI 2x1, Version 2.1, extended addressing, 62 slaves AK = ASI 4x2, Version 2.1, standard addressing, 31 slaves AM = ASI 4x2, Version 2.1, extended addressing, 62 slaves 19

DeviceNet Network Card Advance technology allows solenoid output to operate throughout DeviceNet voltage Onboard diagnostics provides easy calibration ODVA conformance tested to Composite 18 Fully encapsulated electronics module Bus powered inputs and outputs Two built-in sensors for OPEN/CLOSE detection Short/Open Circuit protection EMC certified to directive 89/336/EEC//93/68/EEC (Per Stds. EN61000-6-4, EN61000-6-2) Visual Diagnostics OPEN POSITION CLOSED POSITION LED FOR BUS LINE STATUS No LED lit: No power Flashing Green: Online but no established DeviceNet connections Solid Green: Online with established DeviceNet connections Flashing Red: Timed out DeviceNet I/O connection(s) Solid Red: Communication fault: Duplicate address or incorrect baud rate ASCO is an integrated network module and limit switch package that connects automated valves and external devices directly to the control system reducing the I/O interfaces and wiring associated with a typical hardwired solution. The DeviceNet Network Card is fully encapsulated for superior environmental protection, and LEDs provide visual status of network connection and valve position. Optional diagnostics provide built-in maintenance tools such as cycle count, travel times, self-calibration, and valve information. Our network cards operate with our NR and VR series rotary or HS series linear indicators. Enclosures types range from Nema 4, 4X to Class 1, Division 1, Groups B, C & D. Accessories such as a Network Junction Box are available. Note: ASCO recommends using 12 VDC pilot valves with DeviceNet cards. DeviceNet Technical Specifications Maximum Distance Physical Media Available I/O Network Topology Supported Baud Rate Diagnostics Bus Voltage 500 Meters/1640 Feet @ 125Kbps, 250 Meters/820 Feet @ 250kbps, 100 Meters/328 Feet @ 500Kbps Four wire system (two for communication and two for power) 2 inputs, 1 output 6 inputs, 2 output (includes 4 general purpose inputs) Trunk line/dropline with branching 125 Kbps, 250 Kbps, 500 Kbps Yes 11-25 VDC Ordering Number Example: VR7C2YAW0 A DC = DNet 2x1 DE = DNet 2x1 with diagnostics DD = DNet 6x2 (m1), 2 outputs, single acting DH = DNet 6x2 (m2), 1 output, double acting DF = DNet 6x2 with diagnostics (m1), 2 outputs, single acting DJ = DNet 6x2 with diagnostics (m2), 1 output, double acting 15

Diagnostics 4 Standard Diagnostics Input Status state of input whether valve is CLOSED or OPEN Solenoid Voltage indicates the voltage applied to solenoid Output Status indicates whether the solenoid output is in open or short circuit condition Bus Voltage indicates the DeviceNet voltage at that node Valve Tag # 16 character text for user input of node id Valve Manufacturer 16 character text for user input of valve manufacturer of particular node Actuator Manufacturer 16 character text for user input of actuator manufacturer of particular node Valve Serial # 16 character text for user input of valve serial # of particular node Actuator Serial # 16 character text for user input of actuator serial # of particular node Valve ID # 16 character text for user input of valve ID (part number or type) of particular node Actuator ID# 16 character text for user input of actuator ID (part number or type) of particular node Extended Diagnostics Cycle Count Pilot Valve actual number of cycle, OPEN-to-CLOSE and CLOSE-to-OPEN for the pilot valve Cycle Count Limit Pilot Valve operational cycle limit of the pilot valve. Once limit is exceeded a fault will be sent to PLC/DCS indicating limit exceeded Cycle Count Actuator actual number of cycle, OPEN-to-CLOSE and CLOSE-to-OPEN for the actuator Cycle Count Limit Actuator - operational cycle limit of the actuator. Once limit is exceeded a fault will be sent to PLC/DCS indicating limit exceeded Cycle Count Main Valve (Process Valve) actual number of cycle, OPEN-to-CLOSE and CLOSE-to-OPEN for the pilot valve Cycle Count Limit Main Valve (Process Valve) operational cycle limit of the main valve. Once limit is exceeded a fault will be sent to PLC/DCS indicating limit exceeded 16 Note: the Travel & Break Time below are accurate to 10ms Travel Time OPEN-to-CLOSE the last time between the change-in-state command-close and the indication the valve is in the CLOSE position. This is the recorded value of the last time the valve was used. Setpoint Travel Time OPEN-to-CLOSE calibration value of the time between the change-in-state command-close and the indication the valve is in the CLOSE position. This value is automatically recorded & saved during Calibration command. Tolerance Travel Time OPEN-to-CLOSE maximum allowable difference between Travel Time OPEN-to-CLOSE & Setpoint Travel Time OPEN-to-CLOSE. If Travel Time exceeds Setpoint + Tolerance, then a fault will be sent to PLC/DCS indicating limit exceeded. Travel Time CLOSE-to-OPEN the last time between the change-in-state command-open and the indication the valve is in the OPEN position. This is the recorded value of the last time the valve was used. Setpoint Travel Time CLOSE-to-OPEN calibration value of the time between the change-in-state command-open and the indication the valve is in the OPEN position. This value is automatically recorded & saved during Calibration command. Tolerance Travel Time CLOSE-to-OPEN maximum allowable difference between Travel Time CLOSE-to-OPEN & Setpoint Travel Time CLOSE-to-OPEN. If Travel Time exceeds Setpoint + Tolerance, then a fault will be sent to PLC/DCS indicating limit exceeded. Break Time OPEN-to-CLOSE the last time between the change-in-state command-close and the indication the valve leaves the OPEN state. This is the recorded value of the last time the valve was used. Setpoint Break Time OPEN-to-CLOSE calibration value of the time between the change-in-state command-close and the indication the valve leaves the OPEN state. This value is automatically recorded & saved during Calibration command. Tolerance Break Time OPEN-to-CLOSE maximum allowable difference between Break Time OPEN-to-CLOSE & Setpoint Break Time OPEN-to-CLOSE. If the Break Time exceeds Setpoint + Tolerance, then a fault will be sent to PLC/DCS indicating limit exceeded. Break Time CLOSE-to-OPEN the last time between the change-in-state command-open and the indication the valve leaves the CLOSE state. This is the recorded value of the last time the valve was used. Setpoint Break Time CLOSE-to-OPEN calibration value of the time between the change-in-state command-open and the indication the valve leaves the CLOSE state. This value is automatically recorded & saved during Calibration command. Tolerance Break Time CLOSE-to-OPEN maximum allowable difference between Break Time CLOSE-to-OPEN & Setpoint Break Time CLOSE-to-OPEN. If the Break Time exceeds Setpoint + Tolerance, then a fault will be sent to PLC/DCS indicating limit exceeded. Configurable Behavior in the event that the PLC/DCS stops communicating the device as the ability to automatically switch to a Fail Safe position. Input Identifier for versions with 4 extra inputs the device has 4 general purpose identifiers (16 characters max for each) for user input of devices connected to those inputs.

FOUNDATION Fieldbus 4 The ASCO FOUNDATION Fieldbus Type 4449 (FF4449) The ASCO FF4449 is EMC (electro-magnetic Compliance) approved to ensure immunity against electrical interference from equipment such as hand held radios and has one of the industries lowest power consumption at 12.5mA total. Unlike competitors, the ASCO FF4449 has Link Active Scheduler (LAS) capability and can be configured as a backup Link Master. In the event that communication with the DCS is lost, the FF4449 becomes Link Master of the bus segment and keeps the process running preventing down time. It can also be configured as a Basic device. In this configuration, it can be pre-programmed to move to a Fail-safe position (OPEN or CLOSE) or hold last valid command when communication with the DCS is lost. FF4449 can be configured to operate with both spring return (single acting) and double acting actuators. Visual Diagnostics CLOSED DETECTION: Yellow LED EXTERNAL 24VDC DETECTION: Green LED OPEN DETECTION: Yellow LED The outputs for the FF4449 can be powered with either an external 24VDC or from the bus. For bus powered applications, since available power for operating pilotvalves is limited, piezo based pilot valves must be used due to its inherent low power consumption (typically 6.6VDC @ 1.4mA). The total power consumption for the FF4449 remains at 12.5mA. In this application an external 24Vdc supply is NOT NEEDED. Power for the outputs will be taken from the fieldbus line. With the piezo pilot valves, the operating temperature range is from 0ºC to 60ºC (32ºF to 140ºF). This configuration is required for Intrinsically Safe application. For non-intrinsically safe applications an external 24VDC can be used to supply extra power to the outputs. This will allow cus tomers to use traditional solenoid based pilot valves of up to 1.4watts. In this configuration, the operating temperature range is from -40ºC to 60ºC (-40ºF to 140ºF). Approvals FOUNDATION Fieldbus Inter-operability test (ITK 4.61) EMC Directive (89/336/EEC//93/68/EEC) per EN 61326 CSA approved FM approved Delta V certified as Link Master ASCO power the PlantWeb digital architecture via FOUNDATION Fieldbus by monitoring the diagnostic feedback received from the actuator and process valve to which it is attached. In addition to the various diagnostics available in the ASCO FF, the device also has integrated PlantWeb alerts. With PlantWeb alerts, users can set limits for the device performance. Once the limits in desired performance have been exceeded the device can communicate the information to the user through Plantweb. The Plantweb alerts in also user configurable to either failure, advisory, or maintenance. 20

FOUNDATION Fieldbus Diagnostics Short Circuit detection that outputs are shorted. Separate detection for output # 1 & 2 External Voltage detection that an external 24Vdc supply is connected. This feature is disabled if FF4449 is configured for piezo valves (Bus powered application) Time in Position the time the Process Valve/Actuator has been in its current position. This information is valuable in deter mining if the valve/actuator needs to be cycled to ensure it is not frozen in its current position. Travel Deviation / Lost Position an alert generated if the valve/actuator moves to a position that is not desired. For example the FF4449 energizes an output to OPEN a spring return actuator. The position feedback indicates the device has reached OPEN position. Afterwards, air pressure is lost and the actuator moves back to the CLOSED position (spring-return). The position feedback sensor will indicate the actuator in the CLOSED position although a command to CLOSE the actuator was never issued. In this situation a Travel Deviation alert will be generated indicating the actuator was in a desired position, but moved to undesired position Travel Counters the FF4449 is available with counters that record the number of travels the device has gone through. Two travel counts equals one cycle (travel OPEN + travel CLOSE = 1 cycle). Settable limit indicators are also available. Once the travel count has exceeded the value set in the limit and alert will be generated. There are 3 Travel Counters and limits for the following: Pilot Valve Actuator Process Valve OPEN Times: Calibrated Travel Time Open calibration value of the time between the change-in-state command-open and the indication the valve is in the OPEN position. This value is automatically recorded & saved during Calibration command Last Travel Time Open Last time between Open command and the indication the valve reaches the Open state Average Travel Time Open Average of up to last 30 values. Time between Open command and the indication the valve reaches the Open state Calibrated Break Time Open calibration value of the time between the change-in-state command-open and the indication the valve leaves the CLOSE state. This value is automatically recorded & saved during Calibration command Last Break Time Open Last time between Open command and the indication the valve leaves the Closed state Average Break Time Open Average of up to last 30 values. Time between Open command and the indication the valve leaves the Closed state CLOSED Times: Calibrated Travel Time Close calibration value of the time between the change-in-state command-close and the indication the valve is in the CLOSE position. This value is automatically recorded & saved during Calibration command Last Travel Time Close Last time between CLOSE command and the indication the valve reaches the CLOSE state Average Travel Time Close Average of up to last 30 values. Time between CLOSE command and the indication the valve leaves the Open state Calibrated Break Time Close calibration value of the time between the change-in-state command-close and the indication the valve leaves the OPEN state. This value is automatically recorded & saved during Calibration command Last Break Time Close Last time between CLOSE command and the indication the valve leaves the Open state Average Break Time Close Average of up to last 30 values. Time between CLOSE command and the indication the valve reaches the CLOSE state Average Time Values (Travel & Break times for Open & CLOSE) process valve/actuators typically wear out at a constant steadily pace. A good indication of wear will be the average travel times since the change is slow, but constant. Last Time Values (Travel & Break times for Open & CLOSE) these values are important in determining abnormal events that recently occurred. For example, a temporary drop in pressure or a sticky process valve (valve that has been left in the same position for a long time without cycling) will affect the performance of the last operation of the valve, but does not necessarily mean the mechanical device is worn out. 21

Network Junction Box for AS-interface and DeviceNet Networks For Division 1 bus applications using AS-interface or DeviceNet protocols Switchable to allow for servicing of the node without interruption to the bus communications In the off position it can be locked out or tagged out Explosion proof conduit union for ease of installation and service of system No adapters needed to mount to ASCO VMS products Three 3/4" NPT conduit entries (One to the indicator box and two for bus connections) Seal fittings only needed in Div 1, Group B atmospheres # % Construction Part Body Coating Material Copper free Aluminum Black Epoxy Powder Coated Ambient Temperatures -40 F to 140 F (-40 C to 60 C) Ratings and Approvals FM and CSA approved Type 4X Class I, Division 1, Groups B, C, & D Class II, III, Division 1 Groups E, F, & G Class I, Division 2, Groups A, B, C & D Nonincendive Class II, Division 2, Groups F & G Nonincendive T6 temperature code at -40 F to 140 F ambients Note: See list price schedule for available Junction Box kits. 29

Potentiometer or Transmitter VR Series Option Potentiometer 0 to 1000 ohm resistive outputs to control system, proportional to the process valve position Transmitter 4-20mA signal outputs to control system, proportional to the process valve position Easy calibration of transmitter with on-board LED and calibration button Calibration settings stored in non-volatile memory Gear drive mechanism located above switches for easy access and adjustments (for 0-10K ohms potentiometer) All transmitters are rated for use in intrinsically safe or non-incendive areas Fully encapsulated transmitter circuit board for environmental protection Clockwise or counter-clockwise operation with reversible signal outputs # % Potentiometer 1K ohms Transmitter Electrical Potentiometer Specifications Shaft Rotation Range 0-95 Resistance 0-1000 ohms Full Scale Tolerance ± 100 ohms Linearity ± 2.0% Rotation 300 Terminals 12 pts for pot/switches/accessories Transmitter Specifications Shaft Rotation Range 0-95 (45 minimum) Input Voltage Range 8-38 VDC Potentiometer Resistance 0-10,000 ohms Output Signal Range 4-20mA DC Load Impedance Range 0-800 ohms at 24 VDC Output Impedance 25 M ohms (typical) Offset Error at 4mA ± 20 µa (max) Offset Drift ± 500 µa / C (max) Span Error at 20mA ± 40 µa (max) Span Drift ± 1000 µa / C (max) Linearity ± 2.0% Hysteresis 1.0% of full scale Repeatability ± 0.3% of full scale Input Voltage Effects 2 µa/v (typical) Calibration Auto-setting via pushbutton Indication Red LED (variable brightness with position) Terminals 2pts for 4-20mA + 8pts for switches/accessories How to Specify Potentiometer Option - RW (0-1000ohms resistive output) Transmitter Option - TY (4-20mA signal output) Ordering Example VR8B2YAM2RWA VR8B2YAM2TYA VR8B2YANOTYA (without switches) Mechanical Switch and Network Card available together. 23

Profibus-PA Network Card Low current consumption for Intrinsically Safe bus applications 2 wire bus system with maintenance and diagnostics Fully encapsulated electronics module with 2 built-in Hall Effect sensors for OPEN/CLOSED detection Can be used with single or double acting actuators Galvanic isolation of outputs Addressable by DIP switches or bus line Self-calibration feature EMC certified to directive 89/336/EC (per standards EN50081 & EN50082) Technical Specifications Maximum Distance Physical Media Available I/O Network Topology Supported Baud Rate Number of addressable devices 1900 Meters (6200 ft) 1 twisted pair #18 AWG (0.8 mm 2 ) 2x2 (2 inputs, 2 outputs) Bus, line, star, and combinations 31.25 Kbps up to 126 Optional ASCO Piezo valves SHORT CIRCUIT detection to determine condition of Piezo operator Ambient Temperatures 32 F to +140 F (0 C to +60 C) Electrical Connection is made using shielded two-wire Profibus PA cable Outputs - discrete output - 6.6VDC @ 1.6mA each (One output used at a time) Power consumption of 11.0mA How to Specify Description 2X2 NON "IS" 2X2 "IS" Ordering Example: VR7B2YAW0PAA Code PA PC Approvals Profibus certified CE marked ATEX (II 1 G EEx ia IIC T4) KEMA 03ATEX 1413X FM (Class 3610, 3611) EMC Directive 89/336/EC (per stds. EN50081, EN50082) 17

Diagnostics 4 Valve Information Valve Man 16 character text for user input of pilot valve manufacturer Actuator Man 16 character text for user input of actuator manufacturer Valve Ser Num 16 character text for user input of pilot valve serial # Actuator Ser Num 16 character text for user input of actuator serial # Valve ID 16 character text for user input of pilot valve ID (part number or type) Actuator ID 16 character text for user input of actuator ID (part number or type) Configuration Device can be configured by user for actuation of the following type: Single Output For Single Acting Actuator (Spring return) where only one 3-way pilot valve is needed. Pilot valve is energized to OPEN and de-energized to CLOSE the actuator. Two Outputs For Double Acting Actuator where two 3-way pilot valves are needed. One valve to OPEN and another valve to CLOSE the actuator. If a 4-way pilot valve is used then only 1 is required and configuration should be for single output. Discrete Output Diagnostics TRAVEL COUNT actual number of cycle, OPEN-to-CLOSE or CLOSE-to-OPEN for the actuator. Two travel count equals 1 cycle. TRAVEL COUNT LIMIT operational cycle limit of the actuator. Once limit is exceeded a fault will be sent to PLC/DCS indicating limit exceeded. Note: The Travel & Break Time below are accurate to 10ms TRAVEL TIME OPEN-CLOSE ACT the last time between the change-in-state command-close and the indication the valve is in the CLOSE position. This is the recorded value of the last time the valve was used. TRAVEL TIME OPEN-CLOSE calibration (setpoint) value of the time between the change-in-state command-close and the indication the valve is in the CLOSE position. This value is automatically recorded & saved during Calibration command. TRAVEL TIME OPEN-CLOSE TOL maximum allowable difference between Travel Time OPEN-to-CLOSE & Setpoint Travel Time OPEN-to-CLOSE. TRAVEL TIME CLOSE-OPEN ACT the last time between the change-in-state command-open and the indication the valve is in the OPEN position. This is the recorded value of the last time the valve was used. TRAVEL TIME CLOSE-OPEN calibration (setpoint) value of the time between the change-in-state command-open and the indication the valve is in the OPEN position. This value is automatically recorded & saved during Calibration command. TRAVEL TIME CLOSE-OPEN TOL maximum allowable difference between Travel Time CLOSE-to-OPEN & Setpoint Travel Time CLOSE-to-OPEN. BREAK TIME OPEN-CLOSE ACT the last recorded time between the change-in-state command-close and the indication the valve leaves the OPEN state. BREAK TIME OPEN-CLOSE calibration (setpoint) value of the time between the change-in-state command-close and the indication the valve leaves the OPEN state. This value is automatically recorded & saved during Calibration command. BREAK TIME OPEN-CLOSE TOL maximum allowable difference between Break Time OPEN-to-CLOSE & Setpoint Break Time OPEN-to-CLOSE. BREAK TIME CLOSE-OPEN ACT the last recorded time between the change-in-state command-open and the indication the valve leaves the CLOSE state. BREAK TIME CLOSE-OPEN calibration (setpoint) value of the time between the change-in-state command-open and the indication the valve leaves the CLOSE state. This value is automatically recorded & saved during Calibration command. BREAK TIME CLOSE-OPEN TOL maximum allowable difference between Break Time CLOSE-to-OPEN & Setpoint Break Time CLOSE-to-OPEN. FAIL SAFE MODE in the event that the PLC/DCS stops communicating, the device has the ability to automatically switch to a Fail Safe Mode. Fail Safe Mode is selectable to Hold last good value or go to Fail Safe Position. Fail Safe position is user defined to be either OPEN or CLOSE. In addition, a delay time can be set to allow the device to wait until switching to Fail Safe Mode. 18

Reed Switch Assembly 4 Each switch cup contains either two Tungsten, two Rhodium, or two Rhodium (IS) Reed switches Fully encapsulated hermetically sealed Reed Switches Reed Switch Ambient Temperature -40 F to 150 F (-40 C to 65 C) Construction Cup Encapselant Contacts ABS Silicone Stainless Steel Electrical Reed Switches Tungsten: 120VAC@3A or 24VDC@2A Maximum power allowable is 100 Watts or 100VA Minimum power required to ensure proper operation is 3W or 3VA Rhodium: 24VDC@1A Maximum power allowable is 25 Watts Minimum current required to ensure proper operation is 10mA@3VDC Rhodium (IS): 2mA to 1A@24VDC (suitable for IS applications) IS - Class I,II,III, Div. 1, Groups A,B,C,D,E,F, and G Class I, Zone 1, AEx ib IIC T6 Class I, Zone 1, Ex ib IIC T6 Class I, Zone 0, Ex ia IIC T6 Ordering Number Example: VR2C2Y_2NGA M = REED SPDT Tungsten 3A E = REED SPDT Rhodium 1A S = REED SPDT Rhodium (IS) 22

Slip-Lok Connector for attaching conduit and instruments 4 Patented two piece design for easy installation of equipment in hazardous locations Allows for optimal positioning of components, and locks them into position Reduces time required for connecting and disconnecting conduit from instruments Male NPT threaded connections - No special adapters needed All 303 stainless steel construction to resist corrosion ^ % Construction Body Part Material 303 Stainless Steel O-Ring Buna "N" Ambient Temperatures -20 F to 180 F (-29 C to 82 C) Ratings and Approvals UL approved For use in hazardous areas Class I, Groups A, B, C, & D Class II, Groups E, F, & G Division 1 & 2 Type 4 and 4X CSA approval For use in hazardous areas Class I, Groups B, C & D Class II, Groups E, F & G Division 1 & 2 Ex d IIC Class I, Zone I AEx D IIC Type 4 and 4X Note: See list price schedule for available Slip-lok kits. Optional Please consult ASCO for alternative body threading, materials, and/or elastomers. Important: The Slip-Lok is to be used as an electrical conduit connection only. DO NOT use as a connection in a pressurized pipe. Specifications Pipe Size (ins.) Kit Number 3/4" x 1/2" 323272 1/2" x 1/2" 323273 28