Control block CPX-CM-HPP

Similar documents
Measuring modules CPX-CMIX

Control blocks CPX-CEC- -V3

End-position controllers CPX-CMPX

Control blocks CPX-CEC

Service unit combinations MSE6, MSE series

Motor controllers CMMO-ST

Motor controllers CMMS-ST, for stepper motors

Modular controllers CECX

Motor units MTR-DCI, intelligent servo motors

Motor controllers SFC-DC

Motor controllers CMMD-AS, for servo motors

Controller CMXH-ST2 Key features

Motor units MTR-DCI, intelligent servo motors

Controllers CECC Key features

Fieldbus modules CTEU/installation system CTEL

AS-interface modules CESA

Motor controllers SFC-DC

Axis controllers CPX-CMAX

Electrical adapters, Sub-D socket, 9-pin Technical data

Sensor interface CASM

CPI installation system

Motor controllers CMMP-AS, for servo motors

Fieldbus Direct Key features

Automation system CPX-E

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Air gap sensors SOPA

Fieldbus Direct Key features

CPI installation system

Fieldbus Gateway Type ME43

Motor units MTR-DCI, intelligent servo motors

SBS, vision sensor Key features

Modular electrical terminal CPX

Motor controllers CMMP-AS, for servo motors

Modular electrical terminal CPX

Motor controllers CMMP-AS, for servo motors

Fieldbus slave modules w/o I/Os

Fork light barriers SOOF

Axis controllers SPC200

Modular electrical terminal CPX

Connecting cables for valves, Sub-D socket Type codes

Fork light barriers SOOF

Terminal CPX. Control block CPX-CM-HPP. Description. FHPP interface. Description b [ ]

Connecting cables for valves, plug pattern ZC, metric screw Type codes

2D planar surface gantries

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ]

Pressure sensors SDE5

Pressure sensors SDE5

IE/PB LINK PN IO. PROFINET applications

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Pressure sensors SDE1, with display

Limit switch attachments

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed

System Control Unit (SCU)

Air gap sensors SOPA

Flow sensors SFAB Key features

User Manual Gateway component for EtherNet/IP

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ]

Inclination sensors 2-dimensional, measuring range up to ±90

Electrical adapters, Sub-D socket, 9-pin Technical data

LVX Control Unit. Features:

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Accessories Modular bus covers CANopen

User manual Gateway component Sercos

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Absolute encoders - modular bus covers

Fieldbus Direct Extremely compact and space-saving

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Deutschmann Automation,

Connecting cables, Ethernet Technical data

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

Operator units CDPX Key features

Inclination sensors 1-dimensional, measuring range

PSG55x ATM to Medium Vacuum Gauge

Sensor boxes SRBG Key features

CPX-E-System CPX-E-CEC-...-PN. Description. Function Commissioning Parameterisation [ ]

-U- Type discontinued

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

VersaMax IP Input Module

Pressure sensors SPAE

Signal types Coupler Box and PLC Box

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

Pressure sensors SDE3, with display

Modular electrical terminal CPX-P

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Modular electrical terminal CPX

Accessories Fieldbus Box

SmartWire-DT Modules IP67

Pressure sensors SPAN

Revision to the Operating Instructions

Pressure sensors SPAE

FIELDBUS OVERVIEW Graham Traill 02/09/2015

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

1. CP430, CP470, CP474, CP770 and CP774

Flow sensors SFAM Key features

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ]

Field bus connections Link structure DDL Link structure DDL, bus coupler. Brochure

PCG55x ATM to Medium Vacuum Gauge

Transcription:

Key features New options for controlling drive technology The control block CPX-CM-HPP makes all of Festo s electric drive technology compatible with all industrial communication interfaces. CPX-CM-HPP is controlled using a CPX bus node by a higher-level controller or front end controller in the CPX terminal. Communication with the drives is standardised via the Festo Handling and Positioning Profile (FHPP). The control component is therefore independent of the bus node used. A maximum of four individual electric axes can be connected via CAN bus. PROFINET, EtherNet/IP, EtherCAT PROFIBUS-DP DeviceNet CC-Link CANopen Advantages for users More options Simple Flexible Cost-effective All electric drives from Festo can be controlled via the CPX terminal using the control block CPX-CM-HPP. The control block therefore offers a simple, flexible and cost-effective way of controlling individual axes. No programming required. Quick configuration and diagnostics via the operator unit CPX-MMI. Easy control of electric drives via CAN bus with the Festo Handling and Positioning Profile (FHPP). Compatibility with all control systems via the bus node of the CPX terminal. All electric drive systems from Festo are uniformly controlled with FHPP. CPX-CM-HPP offers a cost-effective fieldbus interface via CAN bus for up to four electric axes. Cost advantages compared with I/O solutions in systems with as few as two electric axes. 2 Internet: www.festo.com/catalogue/... Subject to change 2017/10

Technical data The control block CPX-CM-HPP is a module in the CPX terminal for controlling electric drives. The control component is independent of the bus node used. This means that Festo s electric drive technology is compatible with all industrial communication interfaces. The control block does not need to be programmed. Max. 4 individual electric axes can be controlled via CAN bus No programming required Standardised communication with the drives via the Festo Handling and Positioning Profile (FHPP) Quick configuration and diagnostics via the operator unit CPX-MMI Simple, flexible and cost-effective General technical data Fieldbus interface 1x socket M9, 5-pin Protocol FHPP Max. address volume for inputs [byte] 32 Max. address volume for outputs [byte] 32 LED display (product-specific) Error: Error PL: Power supply Device-specific diagnostics Diagnostic memory Channel and module-oriented diagnostics Undervoltage/short circuit of modules Parameterisation Forcing of channels System parameters Configuration support Operator unit CPX-MMI Total number of axes 4 Nominal operating voltage [V DC] 24 Operating voltage range [V DC] 18 30 Power failure buffering [ms] 10 Intrinsic current consumption [ma] Typically 80 at nominal operating voltage Protection class to EN 60529 IP65, IP67 (plug connector plugged in) Dimensions W x L x H [mm] 50 x 107 x 55 (incl. interlinking block) Product weight (without interlinking block) [g] 140 Materials Housing Note on materials PA, reinforced PC RoHS-compliant Technical data Interfaces Interface Control interface CAN-Bus Baud rate [Mbps] 1 Operating and environmental conditions Ambient temperature [ C] 5 +50 Storage temperature [ C] 20 +70 CE mark (see declaration of conformity) To EU Low Voltage Directive 2017/10 Subject to change Internet: www.festo.com/catalogue/... 3

Technical data Connection and display components 1 3 1 3-digit display 2 Control interface 3 LED display, product-specific 4 Inscription labels 2 4 Pin allocation Control interface Socket M9, 5-pin Pin Signal Meaning 1 n.c. Not connected 2 n.c. Not connected 3 CAN_GND CAN ground 4 CAN_H CAN high 5 CAN_L CAN low Housing Screened Cable screen must be connected to functional earth (FE) Permitted bus nodes/cec Bus node/cec Protocol Max. no. of CPX-CM-HPP modules CPX-CEC 0 CPX-FB6 INTERBUS 0 CPX-FB11 DeviceNet 2 CPX-FB13 PROFIBUS 2 CPX-FB14 CANopen 1 CPX-M-FB21 INTERBUS 0 CPX-FB23-24 CC-Link 1 (function module F23) 0 (function module F24) CPX-FB33 PROFINET RT, M12 2 CPX-M-FB34 PROFINET RT, RJ45 2 CPX-M-FB35 PROFINET RT, SCRJ 2 CPX-FB36 EtherNet/IP 2 CPX-FB37 EtherCAT 2 CPX-FB38 EtherCAT 2 CPX-FB39 Sercos III 2 CPX-FB40 POWERLINK 2 CPX-M-FB41 PROFINET RT 2 4 Internet: www.festo.com/catalogue/... Subject to change 2017/10

Accessories Ordering data Designation Part No. Type Control block Max. 4 individual electric axes can be controlled via CAN bus 562214 CPX-CM-HPP Ordering data Bus connection Designation Part No. Type Connecting cable Connecting cable 2 m 563711 NEBC-M9W5-K-2-N-LE3 Plug for CAN bus interface, Sub-D, 9-pin, without terminating resistor 5 m 563712 NEBC-M9W5-K-5-N-LE3 533783 FBS-SUB-9-WS-CO-K Inscription label Inscription label holder for manifold block 536593 CPX-ST-1 Documentation Manual Control block CPX-CM-HPP German 568683 CPX-CM-HPP-DE English 568684 CPX-CM-HPP-EN 2017/10 Subject to change Internet: www.festo.com/catalogue/... 5