AN6U1903 V1.0 User manual Features of firmware: Mechanical:

Similar documents
AN6DMX V1.0 User manual Components on board: Electrical: Features of firmware: Mechanical: FACE SIDE

T-8000 Operating manual

PIXELATOR MINI PX1-8D DIN-RAIL MOUNTABLE 8 PORT PIXEL CONTROLLER USER MANUAL

SPI DECODER PROGRAM INSTRUCTION

Power Xpert Meter 2000 Gateway Card Kit

H802SE can drive the following chips: LPD6803, LPD8806,

ProPlex IQ 4 RDM DIN Rail Quick Start Guide TMB 24/7 Technical Support

PIXELATOR ( PN )

Domino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Industrial Serial Device Server

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

Network Camera Firmware Upgrade Quick Guide

DMX Dimmer DMX Touch panel decoder with 2.4G remote TM083

Medium parts count, through-hole components (with exception of optional surface mount MAC IC).

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease.

PIXEL PORT ETHERNET PIXEL DRIVER

LED Ethernet Controller 3, SPI-Matrix and Powered LED Ethernet Controller

8 channel Ethernet to analog interface. Web Server Configuration Manual

SSE232-LE Serial Server- User s Manual

SIXTEEN UNIVERSE CONTROLLER

ArtNet-DMX UNIVERSE DR 1.1

User Manual. cmt-svr Startup Guide

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

EGW1-IA3-MB User s Manual

Eight Universe Field Programmable Gate Array (FPGA) based E1.31 pixel controller.

Kling-Force LED User Guide

Software and Hardware Data-sheet

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

LAN Interface TCW120B

BLUE LOG XM / XC. Quick Start Guide. Version

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

PROFINET, EtherNet/IP, Industrial Ethernet, Modbus TCP,

IP PUBLIC ADDRESS INTERFACE

Power Xpert Meter 2000 Gateway Card Kit

Instructions Industrial 4G Router R700 - firmware version B Quick and easy setup of the Industrial 4G Router type R700

Power Xpert Meter 2000 Gateway Card Kit

AXIS FA54 Main Unit. User Manual

Programming through Web browser:

User Manual. cmt-svr Startup Guide

MODEL: GR8-EM. Communication Adaptor GR8 Series

AK-HCU100 MC/MS Software (Firmware) update procedure

Polycom KIRK IP Interface Card - User Guide

2013 version of the T-4000 controller instructions

Innovative Electronics for a Changing World INDEX

DOUG FLEENOR DESIGN. Model: NODE Ethernet to DMX512 Gateway OWNER'S MANUAL

International Headquarters. European Headquarters

BAS1020 Hardware Manual Version 1.0. BA Systems Petershvilevej 1, DK-3200 Helsinge

HWg-STE HWg-STE PoE MANUAL

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

International Headquarters. European Headquarters

Panoramic Power Installation and configuration guide

DATAGATE MK2. Box Contents. Additional Features (licenses) Features. Safety

Quick Installation Guide

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

Industrial PoE Media Converter

Quick Start Guide WALL IE. Version. 7 en. as of FW

POWERWISE INDAC SETUP MANUAL

Hardware technical specifications Front Face of the 512 / 1024 channels interfaces LED 7-segments display operation:...

DEEP SEA ELECTRONICS PLC

GPS NTP Time Server for Intranet Networks DIN RAIL Version

MINLEON NETWORK EFFECTS CONTROLLER SYSTEM (NEC) INSTRUCTION MANUAL

Industrial Ethernet Switch

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

AXIS T8705 Video Decoder. User Manual

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

VIP2C1N / VIP2C1P HD Mini Cube Network Camera

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Network Effects Controller (NEC)

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

T-8000A controller instructions

DP-502 User s Guide Harware Descriptions Software Installation ETM 3.0

WX3IN1+ (v1.27) APRS DIGIPEATER APRS I-GATE APRS-IS -> RF MESSAGES FORWARDING WEATHER STATION SERVER

**CHECK PIN CONFIGURATIONS. APPLYING POWER TO THE DMX INPUT WILL DAMAGE THE CONTROLLER**

USER MANUAL. ProPlex Software. TMB 24/7 Technical Support

Wireless SD Card SPI Controller

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

SST Automation

BROADBAND 3G/4G MODEM Instruction Manual

IXM: Faster Network Deployment

NetCom 413 PRO. Contact Online. More Pictures. Klick on the thumbnails for the large picture. Overview

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

2012 T-1000S Operating manual

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

Firmware Update Process

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

IntesisBox BACnet/IP Server DALI

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

Product startup: G-30 + DIGIWARE C31 - U30-3xI35

Internet Telephony Gateway VGW-402 / VGW-400FS / VGW-400FO. Quick Installation Guide

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Transcription:

35.50 mm 90.00 mm 70.00 mm 30.00 mm AN6U1903 V1.0 User manual 15.01.12 FACE SIDE BACK SIDE Components on board: Two connectors for power supply 10/100 Ethernet connector SDmicro flash card Control button «Set» Six led for indication of the interface 1903 («L0»-«L5») Art-Net LED activity («Artnet») File system LED activity («SD») Power LED («Led») Six output connectors for 1903 chip Mechanical: Weight: 170 grams. Installation on DIN rail 35 mm. Electrical: Supply voltage 7V - 24V Supply current of the controller 350 ma 1903 data lines have overload protection Operation Range -20 C to 50 C figure Features of firmware: Support led chip: WS2811, WS2812, TM1803, TM1804, TM1809, TM1812,UCS1903, UCS1909, UCS1912, UCS2903 for high speed mode. Ethernet protocol Art-Net III Up to six ports output. Up to 170 pixels per port. Web server for configuration net and Art-Net 50 fps. for video applications on every universe 8K buffer for receiving UDP packets 4K buffer for each universe. 125.00 mm 10.00 mm 135.00 mm 145.00 mm 1

1. Connect the power supply and Ethernet 1.1 Power: Power connection may be with any connectors. DC adapter should have output current 500mA. minimum. The supply voltage must be 7V - 24V. All connected devices must be grounded. 1.2 Configure network: These is the defaults settings: IP: 2.0.0.2 MASK: 255.0.0.0 MAC: 12:45:78:98:34:76 Gateway IP: 192.168.0.1 These settings can be changed via the web server, or Art-Net software (Art-Net test Software). IP: 2.0.0.2 MASK: 255.0.0.0 These settings can be changed only via the web server. MAC: 12:45:78:98:34:76 Gateway IP: 192.168.0.1 1.3 Setup network default procedure: a. Disable controller s power supply. b. Push button «Set». Hold down the button. c. Enable controller s power supply. d. Wait two seconds. e. Release the button «Set» 1.4 Example of network settings for the connected PC: 2

2.1 Function: 2. SDmicro card a. Card necessary to store files of the web server and configuration. The card format is: FAT16/32. b. The directory structure is: This structure you can not change. Not permitted to modify the files in WEB directory: «IPCFG.HTM», «IPCFGCH.HTM», «ANCFG.HTM». Other files can be changed to improve the design. Directory «CFG» file contains «AN_6_00.CFG». This file contains all the settings of the controller. c. All the attributes of the files must be in the off position. d. Replace a file «AN_6_00.CFG» on the base, makes the configuration as default. 3. Conrol button «Set» 3.1 This button is used: Setup network default procedure 3.2 Start firmware upgrade. a. Disable controller power supply. b. Unpack and copy file «an6_00.img» to minisd card, in the main directory. Insert the minisd card to minisd slot. c. Push button «Set». Hold down the button. d. Enable controller s power supply. e. Wait for downloading of the image. f. Delete «an6_00.img» file from the flash. 4. Led output(l0 - L5) 4.1 Displayed receiving packets for the port. 5. Art-Net LED activity 5.1 Displays the reception of the packets Art-Net. 5.2 Displays the flash memory operations of the processor. 6.1 Displays file system requests. 6.2 Displays errors of the image loading. 6. File system LED activity 3

7. Art-Net configuration 7.1 The controller can be configured in two ways. Through a web user interface and via Art-Net protocol. 7.2 To enter you need to dial in your browser: http://2.0.0.2 (if address as default). Click on the link «ArtNet config». 7.3 For each universe can output up to 510 channels(170 pixels). 7.4 For each universe can set the start address to led strip. The address can be 0-511. Example: You are using the channels 0-200 to control DMX devices. You have the address 201 output to strip. In the tape will be outputs channels 201-511. 7.5 To save the configuration you must click on the button «ArtNetConfig». The controller will restart with the new SETUP. 7.6 You can configure the controller by Art-Net protocol. You must download the free software: Art-Net test Software and run software «DMX-Workshop». 4

7.5 You can test output and input. 5

8. Port 5 and 6 configuration 8.1 Art-Net protocol has a single IP address for 4 ports. Ports 5 and 6 have a virtual IP address. This address is required for the automatic detection of ports 5 and 6. Ports 5 and 6 should receive as BROADCAST. Ports 5 and 6 should receive BROADCAST, if there is a single controller in the system. 8.2 Ports 5 and 6 always get messages to the IP address of the controller (not virtual). If there are more than one controller in the system, then necessary a UNICAST messages. In this case, you must configure the port 5 and 6 manually. 9. Browser. 9.1 We recommend to use the Internet Explorer browser. 9.2 Possible to use Google Chrome or Firefox. 10. Power and data connection. 10.1 Interface LED strip has three wires: Plus, Data, Minus. 10.2 Plus wire must be connected to the plus power supply. 10.3 Data wire must be connected to the terminal D. 10.4 Minus wire must be connected to the minus power supply and to the terminal G. 10.5 Data wire can not be longer than 4.5 meters. 10.6 If the power LED strip is less 7 volts, then you need to connect the controller own power supply. 10.7 The power supply must be grounded. 6

10.8 The logical connection pixels. 10.9 The use of single power supply. 7

Electrowwn-desig 10.10 The use of multiple power supply. Links: Art-Net protocol. FreeStyler Madrix www.soh.cz 8