Xxxxx Xxxxxx DC Voltage Data Logger

Similar documents
Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

High Temperature Data Logger

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

User s Guide. OM-CP-SMR101A-KIT Soil Moisture Data Logger

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

Xxxxx Xxxxxx OM-CP-TEMP1000IS-A. Intrinsically Safe Temperature Data Logger with Stainless Steel Enclosure INSTRUCTION SHEET MQS5096/1216

FMA-7400/7500 Series Configurator

User s Guide. Series. Communication Manual. Shop online at omega.com SM. For latest product manuals:

Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

User s Guide TSD600. Shop online at omega.com SM. For latest product manuals: omegamanual.info

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide. OM-HL-SP Series. Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide HHSL-101. USB Digital Sound Level Data Logger. Shop online at omega.com SM

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

User s Guide. OM-HL-SP Series Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide. OM-HL-EH-TC Series Multi-channel Handheld Thermocouple Temperature Data Logger. Shop online at omega.com

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide OM-DAQXL. Modbus Interface. Shop online at omega.com. For latest product manuals:

OMB-DAQ-TC-RACK OMB-DAQ-2416 OM-NET-1608 OM-USB-32DIO

User s Guide. DPU90-CT PC COMM / Sensor Configuration Tool

User s Guide TXUN-KIT. Loop Link USB Communications Interface. Shop online at omega.com

OM-DAQXL. Multi-Channel Universal Input Touch Screen Data Logger

User s Guide TX69. Universal Smart Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

Product User Guide CTL2000. CTL2000 Carcass Temperature Data Logger with 8 Remote Thermocouple Channels

User s Guide. DIN-190 and DIN-192 Series. Converter Boxes. Shop online at

User s Guide HHM-MG300. Wireless TRMS Multimeter and Insulation Tester. Shop online at omega.com

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM

Shop online at omega.com

User s Guide D6000 SERIES. Digital Transmitters Modbus RTU, RS-485 Output. Shop online at omega.com

User s Guide LVU30 SERIES. Ultrasonic Sensors. Shop online at omega.com. For latest product manuals:

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

User s Guide HHPT-51. Particle Counter. Shop online at omega.com. For latest product manuals:

User s Guide. DRSL-LPO Series. DIN Rail Loop Powered Isolators. Shop online at omega.com

HiTemp140-FP-TSK High Temperature Data Logger with Flexible RTD Probe and Thermal Shield

Temperature & Process Controller/Monitor CNi8C-EN/DPi8C-EN

User s Guide WTC Shop online at. Wind Tunnel Controller. omega.com For latest product manuals: omegamanual.

User s Guide TCL Series Portable Sample Cooling Device

User s Guide. CSi32. Benchtop Controller. Shop online at omega.com. For latest product manuals:

User s Guide HHM250. AC Clamp Meter. Shop online at. omega.com For latest product manuals: omegamanual.info MADE IN TAIWAN

OM-CP-THERMALERT SERIES Precision Wireless Temperature Data Loggers

TM 2. User s Guide. Shop online at omega.com For latest product manuals: CDH-SD11

User s Guide. CSi8DH SERIES. Benchtop Controllers. Shop online at. omega.com For latest product manuals: omegamanual.

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

User s Guide DP301AN DC VOLTMETER DP301AN-AC VOLTMETER. Shop online at omega.com

User s Guide. Shop online at omega.com. FPD3100-D and FPD3100-D-A Series. 12mm LC Digital Display with Analog Output Options

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

User s Guide DP26-TC. Differential Temperature Meter with Thermocouple. Shop online at omega.com

User s Guide HH520. Data Logger Thermometer. 4 Channel Type J, K, T, E. Shop online at omega.com

User s Guide CT89 SERIES. Temperature Recorder. Shop online at. omega.com For latest product manuals: omegamanual.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

USB Server User Manual

User s Guide Servicing North America:

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

User s Guide DRSL-DC4. Bipolar Isolated DIN Rail Signal Conditioner. Shop online at omega.com

3-Axis G-Force Datalogger

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

OM-CP-RFCURRENT2000A Wireless Current Data Logger

User s Guide HHF-312. Mini Anemometer-Psychrometer With Compass And Memory. Shop online at omega.com SM

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

User s Guide OM-DAQXL. Multi-Channel Universal Input Touch Screen Data Logger. Shop online at omega.com

ADVANCED 4/8-PORT SECURE KM SWITCH

User s Guide. LVR300 Series. Shop online at. Continuous Level Switch System

Advanced 8-Port DisplayPort Secure KVM Switch

Bluetooth USB Adapter TALUS. User Guide

User s Guide HH309A. Data Logger Thermometer. Shop online at. omega.com For latest product manuals: omegamanual.

DI-148U. User's Manual. The way PC-based instrumentation should be. 8-Channel USB Data Acquisition Starter Kit. Manual Revision B

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User's Guide. Extech AM A AC Analog Clamp Meter

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

Advanced 2/4-Port DisplayPort Secure KVM Switch

User's Guide. Temperature / Humidity Datalogger. Model 42270

Document ID: DOC-IPG-2004 Revision: 1.10 Release Date: December 13th, Advanced 2/4-Port DVI-I Secure KVM Switch

User s Guide CL532. ma/v Loop Calibrator with Loop Diagnostic. Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

User s Guide LDN-PS. Shop online at. omega.com For latest product manuals: omegamanual.info. solartron

LCI Load Cell Junction Box with Fault Monitor

Advanced 4/8 Port Secure KM Switch

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

OME-SERIES DATA ACQUISITION CARDS

OM-CP-RFCO2RHTEMP2000A

Illuminate 25 Light Starter Kit What s included Light String Control Box Spare Fuses Safety Instructions Quick Start Guide

ARIENSE SENSE YOUR WORLD. 3-Axis Force Sensor FSE103. User Guide. Version 2.1. July VARIENSE INC.

User s Guide. OM-CP-PR2000 Pressure Data Logger with LCD Display. Shop online at

User s Guide. 600A AC Clamp Meter. Model 38387

Advanced 4/8-Port DVI-D Matrix KVM

Advanced 2/4 Port DisplayPort to HDMI Secure KVM

LCI User Manual mantracourt.com

ADVANCED 4/8 PORT DVI-D MATRIX SECURE KVM SWITCH

OMEGA. HH504 Digital Thermometer

User s Guide. POWERVAR Single Phase Power Conditioners

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version

VELOCICALC Air Velocity Meter

DataPort 250 USB 2.0 Enclosure User s Guide (800)

Transcription:

OM-CP-VOLT101A Xxxxx Xxxxxx DC Voltage Data Logger INSTRUCTION SHEET MQS5772/1216 Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info

Product Overview The OM-CP-VOLT101A data loggers are versatile data logging devices with many uses and applications. Connect negative and positive wire leads directly to the terminal port on the OM-CP-VOLT101A to monitor and measure voltage levels. The OM-CP-VOLT101A is commonly used to assess battery efficiencies or photovoltaic studies to identify how much energy is being created from solar cells. The OM-CP-VOLT101A features a removable terminal block to allow for simple retrieval of the data logger for downloading while leaving the leads connected. With a ten year battery life and the ability to store up to one million time and date stamped readings, this device is ideal for long term deployment and voltage studies. Four models of the OM-CP-VOLT101A are available. The 2.5V is capable of measuring -3V to 3 V, the 15 V capable of measuring -8V to 24V, and the 30V which can measure from -8V to 32V. For lower voltage applications that require a higher resolution, Omega also offers the OM-CP-VOLT101A-160MV model, which can measure voltage between -160 and 160mV. Wiring the Data Logger OM-CP-VOLT101A, 2.5V, 15V and 30V models Single Ended Wiring OM-CP-VOLT101A-160MVDC Differential Wiring Two-position removable screw terminal connections; accepts 2-wire configurations. Three position removable screw terminal connections, accepts 3 wire configurations. Warning: Note the polarity instructions. Do not attach wires to the wrong terminals. LEDs - Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start mode - Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to indicate an alarm condition Engineering Units Native measurement units can be scaled to display measurement units of another type. This is useful when monitoring voltage outputs from different types of sensors such as temperature, CO2, flow rate and more. Password Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password. Multiple Start/Stop Mode Activation - To start device: Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. The device has started logging. - To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash during this time. The device has stopped logging. Alarm User selectable high and low voltage limits. 2

Troubleshooting Tips Why is the wireless data logger not appearing in the software? If the OM-CP-VOLT101A or OM-CP-VOLT101A-160MV doesn t appear in the Connected Devices panel, or an error message is received while using the OM-CP-VOLT101A or OM-CP-VOLT101A-160MV, try the following: Check that the OM-CP-IFC200 is properly connected. For more information, see Troubleshooting Interface Cable problems (below). Ensure that the battery is not discharged. For best voltage accuracy, use a voltage meter connected to the battery of the device. If possible, try switching the battery with a new OM-CP-BAT105. Ensure that no other Omega software is running in the background. Ensure that Omega Software is being used. Ensure that the Connected Devices panel is large enough to display devices. This can be verified by positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then dragging the edge of the panel to resize it. The screen layout may also be reset in the options menu by selecting File, Options, and scrolling to the bottom. Troubleshooting Interface Cable problems Check that the software properly recognizes the connected OM-CP-IFC200. If the data logger is not appearing in the Connected Devices list, it may be that the OM-CP-IFC200 is not properly connected. 1. In the software, click the File button, then click Options. 2. In the Options window, click Communications. 3. The Detected Interfaces box will list all of the available communication interfaces. If the OM-CP-IFC200 is listed here, then the software has correctly recognized and is ready to use it. Check that Windows recognizes the connected OM-CP-IFC200. If the software does not recognize the OM-CP-IFC200, there may be a problem with Windows or the USB drivers. 1. In Windows, click Start, right-click Computer and choose Properties or press Windows+Break as a keyboard shortcut. 2. Click Device Manager in the left hand column. 3. Double click Universal Serial Bus Controllers. 4. Look for an entry for Data logger Interface. 5. If the entry is present, and there are no warning messages or icons, then windows has correctly recognized the connected OM-CP-IFC200. 6. If the entry is not present, or has an exclamation point icon next to it, the USB drivers may need to be installed. These are available on the software flash drive included with the OM-CP-IFC200. Ensure that the USB end of the OM-CP-IFC200 is securely connected to the computer. 1. Locate the USB-A plug of the OM-CP-IFC200. 2. If the interface cable is connected to the PC, unplug it. Wait ten seconds. 3. Reconnect the cable to the PC. 4. Check to make sure that the red LED is lit, indicating a successful connection. 3

Installation Guide Installing the Interface cable - OM-CP-IFC200 Refer to the Quick Start Guide included in the package. Installing the software Insert the Omega Software Flash Drive in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Installation Wizard. Device Operation Connecting and Starting the data logger 1. Once the software is installed and running, plug the interface cable into the docking station. 2. Connect the USB end of the interface cable into an open USB port on the computer. Place the data logger into the docking station. 3. The data logger will automatically appear under Connected Devices within the software. 4. For most applications, select Custom Start from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click Start. ( Quick Start applies the most recent custom start options, Batch Start is used for managing multiple loggers at once, Real Time Start stores the dataset as it records while connected to the logger.) 5. The status of the device will change to Running, Waiting to Start or Waiting to Manual Start, depending upon your start method. 6. Disconnect the data logger from the docking station and place it in the environment to measure. Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device cannot be restarted until it has been re-armed by the computer. Downloading data from a data logger 1. Connect the logger to the docking station. 2. Highlight the data logger in the Connected Devices list. Click Stop on the menu bar. 3. Once the data logger is stopped, with the logger highlighted, click Download. You will be prompted to name your report. 4. Downloading will offload and save all the recorded data to the PC. 4

Product Maintenance Battery Replacement Materials: Small Phillips Head Screwdriver & Replacement Battery (OM-CP-BAT105) 1. Puncture the center of the back label with the screw driver and unscrew the enclosure. 2. Remove the battery by pulling it perpendicular to the circuit board. 3. Insert the new battery into the terminals and verify it is secure. 4. Screw the enclosure back together securely. Note: Be sure not to over tighten the screws or strip the threads. Recalibration The OM-CP-VOLT101A and OM-CP-VOLT101A-160MV standard calibration depends on the range. Voltage 160mV 2.5V 15V 30V Range 0V and 90-160mV 0V and 2.25-2.5V 0V and 13.5-15V 0V and 27-30V Recalibration is recommended annually for any Omega data logger; a reminder is automatically displayed in the software when the device is due. 5

OM-CP-VOLT101A General Specifications Description OM-CP-VOLT101A Range 2.5V 15V 30V Measurement Range (VDC) -3 to +3V -8 to +24V -8 to +32V Calibrated Accuracy Measurement Resolution (mv) Overload Protection Memory +-0.05%FSR 0.1mV 0.5mV 1.0mV ±50V, indefinitely 1,000,000 readings; software configurable memory wrap 330,000 in enhanced start/stop mode Reading Rate 4 readings very second (4Hz) up to 1 reading every 24 hours LED Indicator Red & Green Required Interface Package OM-CP-IFC200 Baud Rate 115,200 Typical Battery Life 10 years at a 15 minute reading rate Operating Environment -40 C to +80 C (-40 F to +176 F), 0%RH to 95%RH non condensing Enclosure Material ABS plastic Dimensions 1.4 x 2.5 x 0.6 (36mm x 64mm x 16mm) Weight 0.9oz (24g) Approvals CE 6 Battery Warning WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 C (176 F). Specifications subject to change. See Omega s terms and conditions at www.omega.com

OM-CP-VOLT101A-160MV General Specifications Description OM-CP-VOLT101A-160MV Range 160mV Measurement Range (VDC) ±160mVDC Measurement Resolution 5µV Calibrated Accuracy ±0.01%FSR Memory 1,000,000 readings; software configurable memory wrap 330,000 in enhanced start/stop mode Reading Rate 4 readings very second (4Hz) up to 1 reading every 24 hours LED Indicator Red & Green Required Interface Package OM-CP-IFC200 Baud Rate 115,200 Typical Battery Life 10 years at a 15 minute reading rate Operating Environment -40 C to +80 C (-40 F to +176 F), 0%RH to 95%RH non condensing Enclosure Material ABS plastic Dimensions 1.4 x 2.5 x 0.6 (36mm x 64mm x 16mm) Weight 0.9oz (24g) Approvals CE 7 Battery Warning WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 C (176 F). Specifications subject to change. See Omega s terms and conditions at www.omega.com

omega.com info@omega.com U.S.A. Headquarters: Servicing North America: Omega Engineering, Inc. Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.