Click Desktop Kit. Click Desktop Kit

Similar documents
2U Congestion Alert Rack Insert for UK

Cabinet Interface Device

Click! 301. Serial to Ethernet Converter

Bluetooth to Serial Converter TOP FRONT. Click 421

Intersection Preassembled Backplate DC

Intersection Segmented Backplate

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification.

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

E-Series Site Preparation Guide

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Industrial Power Supplies

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Single Phase Systems-North American PC125/PC420 Series

Thermal-Magnetic Circuit Breaker 2216-S

EATON Transformer Module

General Purpose Chassis for PXI and CompactPCI

Hardened PoE Ethernet Switch

Overvoltage Protection

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Power supply module, bus connection module

TRC-190 User s Manual

Industrial Power Supplies

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Gas Discharge Tube. Indicator Light(2) UL Parallel 1600 V N N / PU-20KS10KTTN. UL Series 1600 V N N 15 A PU-20KD10KTTN

UPS Series. features: uninterruptible power supply. what great systems are built on.

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

TRC-190 User s Manual

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9

MC 11 EB-2 Power supply cabinet with external bus, AC version

Introduction Circuit Protection

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Hardened Media Converter

Three Phase Systems-International PC302-I/MTD

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

Output Voltage* (nom.)(adjustable)

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

MONITORING INTELLIRACK USER MANUAL

Output Voltage* (nom.)(adjustable)

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

RT4B-110V/12A RECTIFIER

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

RT12-240V/2.4kW Rectifier Specification

PT 3-PB-ST. Extract from the online catalog. Order No.:

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Models HP Z VR Backpack G1 Dock

Uninterruptible Power Supplies

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Chassis Power Supplies

Junos WebApp Secure 5.0 Hardware Guide

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Site Preparation CHAPTER

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

PV Rapid Shutdown device

TPE 1464 Series Pressure Transducer

Programmable Controller IC697ACC721/724/744

Power Enclosure Components

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Universal Power Supplies

Electronic timer CT-ERS.21

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

MAJOR VA Power Inverter

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

General. Environmental. EMC & Safety

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Installing the IPS 4345 and IPS 4360

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

RT4F-110V/25A RECTIFIER

Premium Online Series

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Surge Protection for Surveillance Systems

SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial

Industrial Ethernet Switch

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Transcription:

Click Desktop Kit Click Desktop Kit The Click Desktop Kit is a desktop-mounted set that gives you the building blocks necessary to work with your Click modules at your computer, whether you re testing the link on a Click communication device, configuring a Click contact closure card, or developing custom applications on the Click 500. Features Purchase along with desired Click modules for easy development, configuration or testing Professional power pack protects modules, and comes prewired to T-bus and to edge connector slot Eleven-inch DIN rail features five T-bus expansion slots for landing modules One 44-pin edge connector socket allows use with systems involving rack cards Also includes: RS-232 cable connects Click devices to computer Precision screwdriver for control of DIP switches and easy wiring Can be purchased along with Click 500 development kit to provide you with all the equipment needed to develop the Click 500 Click 210 Click 230 Click 201 Click Desktop Kit 8-ft. AC Cord 6-ft. Straight Serial Cable WX-500-0222 1

Click Desktop Kit Technical Specifications Assembly Components Click desktop stand with 44-pin edge connector socket and 11- inch DIN rail Click power plant DIN rail mounted plug with 120 VAC input power cable Click 210 circuit breaker Click 230 AC surge protector Click 201 AC to DC power converter prewired to T-bus and edge connector slot T-bus 2 T-bus 5 screw terminal blocks (1 left, 1 right) 4 green T-bus connectors (power and communication) 1 gray T-bus connector (power only) Straight-through RS-232 cable Precision screw driver Pelican-brand carrying case Click Desktop Stand Specifications Weight: 1.4 lb (0.64 kg) dimensions: Folded: 12 in. x 5.5 in. x 0.88 in. (30.5 cm x 14 cm x 2.2 cm) Standing: 12 in. x 5.625 in. x 5 in. (30.5 cm x 14.29 cm x 12.7 cm) Made of 1/8-in. aluminimum 1 11-in. (28-cm) DIN rail Edge connector socket for inserting rack cards: Dual edge 44-position socket Accommodates 0.62±0.008 in. (1.57±0.2 cm) PC board 3 A rating per contact Cable and Plug Specifications 120 VAC Cable 8 ft. (2.4 m) in length Plug mounts on DIN rail Click 210 Weight: 0.07 lbs. (31.8 g) dimensions: 0.3 in. x 2.5 in. x 3.4 in. (0.08 cm x 6.4 cm x 8.6 cm) Ambient operating temperature: -4 F to 140 F (-20 C to 60 C) Nominal operating voltage: 250 VAC, 65 VDC Nominal current: 0.5 A for Click 210, 2 A for Click 210-02, 8 A for Click 210-08 Ordering Information Click Desktop Kit CLK-DSK ACCESSORIES CLK-500-ADD Click 500 development add-on Wavetronix 78 East 1700 South Provo, UT 84606 801.734.7200 sales@wavetronix.com www.wavetronix.com Two screw terminals for wiring in and out Configuration Feature Push-button used to reset device after a current interruption Fuse Slow-blow fuse Switching Capacity Switching capacity: 6x IN for nominal currents 0.25 A to 4 A, 8x IN for nominal currents 6 A to 10 A Life Expectancy Life expectancy: 3000 cycles Passes manufacturer s test before shipping Click 230 (see Click datasheet for complete details) Weight: 0.2 lbs. (0.1 kg) dimensions: 0.7 in. X 2.6 in. X 3.5 in. (1.8 cm x 6.6 cm x 8.9 cm) Ambient operating temperature: -40 F to 185 F (-40 C to 85 C) 2 www.wavetronix.com

Click Desktop Kit Ratings Nominal operating voltage: 120 VAC for Click 230, 230 VAC for Click 230-02 Nominal current In: 26 A Maximum continuous operating voltage: 150 VAC for Click 230, 253 VAC for Click 230-02 Maximum discharge current (8/20μS): 10 ka Has eight screw terminal connections: line, neutral and ground for power coming in; line, neutral and ground for power going out; two testing terminals Surge Protection Three-stage surge protection: fast-responding surge-arresting diodes; high-powered current-handling gas discharge tubes; series decoupling elements Passes manufacturer s test before shipping Tested under NEMA TS2-2003 Click 201 (see Click datasheet for complete details) Weight: 0.46 lbs. (0.21 kg) dimensions: 4.5 in. 3.9 in. 0.9 in. (11.4 cm x 9.9 cm x 2.3 cm) Ambient operating temperature: -29 F to 140 F (-34 C to 60 C) with between 140 F and 165 F (60 C and 74 C) derating Humidity: up to 95% RH Pluggable screw terminals for easy pre-wiring output at -29 F to 140 F (-34 C to 60 C): 1 A At temperatures between 140 F to 165 F (60 C and 74 C), output will decrease at a rate of 2.5% per degree Celsius temperature increase input: 100 240 VAC at 45 65 Hz Surge Protection Complies with the applicable standards stated in the IEC 61000-4-5 Standard for AC input power lines Efficiency Efficiency in converting AC input to DC: 80% or greater UL Listed Listed with UL under UL 508; complies with all applicable UL 508 standards NEMA TS2-1998 Complies with the applicable standards stated in the NEMA TS2-1998 Standard Test results available for each of the following tests for the Click 201/202: Shock pulses of 10g, 11 ms half sine wave Vibration of.5 Grms up to 30 Hz 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage Stored at -49ºF (-45ºC) for 24 hours Stored at 185ºF (85ºC) for 24 hours Operation at -29.2ºF (-34ºC) and 10.8 VDC Operation at -29.2ºF (-34ºC) and 26.5 VDC Operation at 165.2ºF (74ºC) and 26.5 VDC Operation at 165.2ºF (74ºC) and 10.8 VDC Device is tested by the manufacturer before shipment Tested under NEMA TS2-2003 (see Click datasheet for complete details) T-bus 5 screw Terminal Block Specifications imensions: 0.8 in. x 0.7 in. x 0.43 in. (2 cm x 1.7 cm x 1.1 cm) Weight: 0.009 lbs. (0.39 g) Pitch: 0.15 in (0.38 cm) Comes in left and right end models for correct assembly (this backplate comes with left end model) Nominal current: 8 A Nominal voltage: 160 V Type of connection: screw terminal connection Number of positions: 5 Wire: 30 14 AWG Passed manufacturer s mechanical, electrical and material tests (see Click datasheet for complete details) 3

Click Desktop Kit T-bus Connector Specifications Dimensions: 1.4 in. x 1.2 in. x 0.7 in. (3.5 cm x 3 cm x 1.7 cm) Weight: 0.01 lbs. (4.5 g) Comes in two models: green for data and power, gray for power only Nominal current IN: 8 A Nominal voltage UN: 150 V Passed manufacturer s mechanical, electrical and material tests (see Click datasheet for complete details) RS-232 Cable Specifications Straight-through cable 6 ft. (1.8 m) in length 2 DB-9 connectors, 1 male and 1 female Other Precision flathead screwdriver (2.5 mm) with Click branding 4 www.wavetronix.com

Click Desktop Kit Click Desktop Kit Bid Specification 1.0 General. This item shall govern the purchase of a hardware kit (HK) equivalent to the Wavetronix Click Desktop Kit. 2.0 Product Description. The HK shall includes the following elements: a desktop stand with DIN rail and 44-pin edge connector; an AC power cable with plug; a circuit breaker equivalent to the Click 210; an AC surge suppresion device equivalent to the Click 230; a DC power supply equivalent to the Click 201; T-bus connectors and end blocks; a straightthrough cable; and a precision screwdriver. 5