SRP Field Upgrade Installation Instructions

Similar documents
Maintaining the ERX System

Maintaining E-Series Routers

SDRAM Installation Instructions

Maintaining the ERX System

TX Matrix Cable Shelf Assembly Installation Instructions

E320 Quick Start Guide

Installing and Upgrading Memory and Virtual Private Network Modules

Technical Configuration Example

Installing and Removing SDRAM and DRAM

Routing Engine, MCS, and CB Installation Instructions

Switch Interface Board (SIB) Installation Instructions

Conversion Instructions for SSG 300M-series Security Devices and J-series Services Routers

MX480 3D Universal Edge Router

Conversion Instructions for SSG 500M-series Security Devices and J-series Services Routers

M160 Internet Router Release Notes

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Removing and Installing the ISA and the ISM

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

SRX 5600 Services Gateway DC Power Supply Installation Instructions

SRX 5600 and SRX 5800 Services Gateway Routing Engine Installation Instructions

J-series Services Router Crypto Accelerator Module Installation Instructions

Replacement Instructions

DX Application Acceleration Platform Quick Start

M-series, MX-series, and T-series Routing Engine and MCS Installation Instructions

M-series and T-series Routing Engine and MCS Installation Instructions

Replacing the Power Supply

Removing Components from the MX960 Chassis Before Installing It Without a Lift

Quick Start. M160 Internet Router. Juniper Networks, Inc North Mathilda Avenue Sunnyvale, CA USA

DX 32xx and DX 36xx Quick Start

C2000 and C4000 Hardware Quick Start Guide

Maintaining the Cisco Catalyst 5500 Multiswitch Router

EMC 10T "CE" Mechanical Upgrade Procedure

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Upgrading Memory in Cisco 800 Series Routers

Adding or Replacing a PCI Card

Voice Feature Card. Overview CHAPTER

Dell Inspiron XPS and Inspiron 9100 Service Manual

XTM 1050 Replacement Parts Installation

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS SRX SERIES SERVICES GATEWAY SRX650

Dell Inspiron N5110 Service Manual

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Dell XPS L702X Service Manual

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

0. Silicon Graphics O2 and Silicon Graphics Octane R12000 CPU Upgrade Information

Gateway Profile 4 service guide

Installing a New Solo 1150 Hard Drive

Dell XPS M1730 Service Manual

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Removing Components from the MX480 Chassis Before Installing It Without a Lift

Peel/Rewind Upgrade Kit

Managing Individual Components

Oracle <Insert Picture Here>

Pro-Flo System Digital Controller EPROM Upgrade

Removing and Replacing Parts

Installing the MWAM CHAPTER

C-series Platforms C2000 and C4000 Field Replaceable Unit Installation Instructions

Dell XPS M1530 Service Manual

Installation Job Aid for Ethernet Routing Switch 5900 Series

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS SRX-SERIES SRX210B

Dell XPS 14z Owner s Manual

To connect the AC adapter:

Replacing Preamplifier Circuit Boards

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

Dell OptiPlex All-in-One. Stand Installation Guide

Installing the Interface Line Card in the Cisco cbr Chassis 6

Junos OS Multiple Instances for Label Distribution Protocol Feature Guide Release 11.4 Published: Copyright 2011, Juniper Networks, Inc.

Customer Replacement Procedure

Replacing/Upgrading Mac Pro Processors (Early 2008)

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

Upgrading and Servicing Guide

Chapter 4 Replacement Procedures

Contivity Extranet Switch Installing Hardware Options Guide

ERX System Overview. The ERX System. This chapter provides information about the system.

Upgrading and Servicing Guide

4.1 General. 4 Replacement Procedures

H3C S12500 Routing Switch Series

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

Intel NUC Kit NUC6CAYS User Guide

Getting Started: Smart Ringswitch Family

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015

This section describes the software and hardware requirements for the module.

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

PC9/P9 CPU Card Replacement

Removing and Replacing FRUs from the Cisco ASR 1001-X Router

Installing the NVR Connectivity and 2nd CPU Kits 1

M40e and M160 CIP Installation Instructions

Customer Upgrade Procedure

Sonnet AV/HPV Card Video Adapter Kit

Juniper Networks G10 CMTS

Replacing the Gateway M305 Optical Drive

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

QFX10008 Switch Quick Start Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Replacing or Upgrading DiskOnChip Memory

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Transcription:

SRP Field Upgrade Installation Instructions 03 November 2004 Part No: 162-00982-00 Revision A01 This document describes installation procedures for upgrading switch route processor (SRP) modules, I/O modules, and nonvolatile storage (NVS) for the Juniper Networks, Inc. ERX-14xx and ERX-7xx routers. You can also find these upgrade instructions and complete hardware documentation on the Juniper Networks technical documentation Web page, which is located at http://www.juniper.net/techpubs/. Contents Overview... 2 Upgrading ERX-14xx and ERX-7xx Routers... 2 Upgrading Memory on ERX-14xx and ERX-7xx Routers... 3 Upgrading a System with One SRP... 3 Upgrading a System with Two SRPs... 5 Upgrading SODIMMs... 9 Upgrading the SRP I/O Module... 11 Restoring the JUNOSe Software Configuration... 12 Upgrading NVS on the ERX-1440 Router...13 Attaching the New Faceplate Label... 14 Registering the Upgraded System... 15 List of Technical Publications... 15 Requesting Support...16 Revision History... 16 1

SRP Field Upgrades Overview Juniper Networks E-series routers contain SRP modules, which perform system management, routing table calculations and maintenance, forwarding table computations, statistics processing, configuration storage, and other control functions. SRP modules are PowerPC-based systems with their own memory, nonvolatile disk storage, and power supply. The ERX-14xx and ERX-7xx routers use one or two redundant SRP modules. To upgrade an ERX SRP module, you follow this general process: 1. Check to see how much memory is currently installed on the router. 2. Prepare for the upgrade by checking the contents of the upgrade kit and assembling all tools and materials. 3. Save the running configuration (optional) if you are installing or replacing a redundant SRP. 4. Halt the system. 5. Remove the SRP module from the chassis. 6. Remove the old SODIMMs, if necessary, and install the new SODIMMs. 7. Install any additional upgrades, such as NVS or I/O modules. 8. Reinstall the SRP module in the chassis. 9. Restore the saved JUNOSe software configuration or perform a fresh configuration. The following sections provide specific instructions on how to perform upgrades. Upgrading ERX-14xx and ERX-7xx Routers This section describes how to upgrade the SRP memory, NVS, and the SRP I/O module for the ERX router. Prepare for the upgrade by assembling the following items: Flathead screwdriver Phillips screwdriver Antistatic wrist strap Antistatic mat and bags to hold components The upgrade kits needed 2 Upgrading ERX-14xx and ERX-7xx Routers

Upgrading Memory on ERX-14xx and ERX-7xx Routers This section describes how to upgrade memory on the router. The upgrade procedure you follow depends on whether you have one SRP or two redundant SRPs. Upgrading a System with One SRP In a router with one SRP module, the SRP module is installed in either slot 6 or slot 7 on the ERX-14xx or slots 0 and 1 on the ERX-7xx. To upgrade a router with one SRP module, follow this procedure: 1. Check the memory currently installed in the SRP by issuing the show hardware command. 2. Optionally, save the configuration currently running on the router to a remote router configuration file with a.cnf extension. For example: host1#copy running-configuration erx1440conf.cnf 3. Halt the SRP module installed in the router by issuing the halt command. The OK and FAIL LEDs lights start to blink on the module. 4. Attach the antistatic wrist strap to your wrist and connect it to one of the ESD grounding jacks on the router. WARNING: Do not insert any metal object, such as a screwdriver, or place your hand into an open slot or the backplane when the E-series router is on. Remove jewelry (including rings, necklaces, and watches) before working on equipment that is connected to power lines. These actions prevent electric shock and serious injuries. CAUTION: When handling modules, use an antistatic wrist strap connected to the router s ESD grounding jack, and hold modules by their edges. To not touch the components, pins, leads, or solder connections. These actions help to protect the module from damage by electrostatic discharge. 5. Use a Phillips screwdriver to loosen the thumbscrews located at the top and bottom of the LED panel on the SRP module. 6. Move the ejector handles located at the top and bottom of the module so that they are in the open position, as shown in Figure 1. Upgrading Memory on ERX-14xx and ERX-7xx Routers 3

SRP Field Upgrades Figure 1: Open and Closed Positions for Ejectors Opened Closed Closed Opened g015316 7. Slide the SRP module out of the chassis and rest it on the antistatic mat with memory sockets and NVS card facing up. 8. Install the new SODIMMs on the SRP. Follow the directions in Upgrading SODIMMs on page 9. 9. If you are also upgrading nonvolatile storage, replace the existing NVS card. Follow the directions in Upgrading NVS on the ERX-1440 Router on page 13. 10. If you are also upgrading the SRP I/O module, replace the I/O module. Follow the directions in Upgrading the SRP I/O Module on page 11. 11. Attach the new faceplate label to the SRP as described in Attaching the New Faceplate Label on page 14. 12. Reinstall the SRP module into the chassis: Install the SRP module in slot 6 or slot 7 on the ERX-14xx or in slot 0 or slot 1 on the ERX-7xx Install the SRP module 4 Upgrading Memory on ERX-14xx and ERX-7xx Routers

Ensure that the ejectors are in the open position Slide the module in between the guides at the top and bottom of the slot Pushthemoduleallthewayintothechassisuntiltheejectorsareflush with the front of the chassis CAUTION: If the module does not slide all the way into the chassis, do not force it. Carefullyremoveitandmakesurethatyouareinstallingitinthecorrectslotand that the module is between the slot s metal guides. 13. Press the ejectors into their closed position as shown in Figure 1. 14. Tighten the module s captive screws using a Phillips screwdriver. Alternate tightening each screw until all are secure and the module is securely seated. 15. Issue the show hardware command to check that the new components are available to the router and that the correct memory capacity is available. 16. Restore the software configuration, if appropriate, as described in Restoring the JUNOSe Software Configuration on page 12. Upgrading a System with Two SRPs In an ERX-14xx with a redundant SRP module, the primary SRP module is installed in slot 6 and the redundant SRP module is installed in slot 7 In an ERX-7xx with a redundant SRP module, the primary SRP module is installed in slot 0 and the redundant SRP is installed in slot 1. To upgrade an ERX router that contains two SRP modules, follow this procedure: 1. Check the memory currently installed in the SRPs by issuing the show hardware command. 2. Prepare for the upgrade by ensuring that you have the following items: Flathead screwdriver Phillips screwdriver Antistatic wrist strap Antistatic mat and bags to hold components The SRP upgrade kit WARNING: Do not insert any metal object, such as a screwdriver, or place your hand into an open slot or the backplane when the E-series router is on. Remove jewelry Upgrading Memory on ERX-14xx and ERX-7xx Routers 5

SRP Field Upgrades (including rings, necklaces, and watches) before working on equipment that is connected to power lines. These actions prevent electric shock and serious injuries. CAUTION: When handling modules, use an antistatic wrist strap connected to the router s ESD grounding jack, and hold modules by their edges. To not touch the components, pins, leads, or solder connections. These actions help to protect the module from damage by electrostatic discharge. 3. Halt the redundant SRP module installed in the router by issuing the halt standby command. The OK and FAIL LEDs lights start to blink on the module. 4. Attach the antistatic wrist strap to your wrist and connect it to one of the ESD grounding jacks on the router, located inside the front bezel and in the upper-right corner on the rear of the chassis. 5. Remove the redundant SRP module from the slot by loosening the thumbscrews with a Phillips screwdriver and lifting the ejector handles located at the top and bottom of the SRP module so that they are in the open position asshowninfigure2. 6 Upgrading Memory on ERX-14xx and ERX-7xx Routers

Figure 2: Open and Closed Positions for Ejectors Opened Closed Closed Opened g015316 6. Slide the SRP module out of the chassis and rest it on the antistatic mat with memory sockets and NVS card facing up. 7. Install the new SODIMMs on the SRP. Follow the directions in Upgrading SODIMMs on page 9. 8. If you are also upgrading nonvolatile storage, replace the existing NVS card. Follow the directions in Upgrading NVS on the ERX-1440 Router on page 13. 9. If you are also upgrading the SRP I/O module, replace the I/O module. Follow the directions in Upgrading the SRP I/O Module on page 11. 10. Attach the new faceplate label to the SRP as described in Attaching the New Faceplate Label on page 14. 11. Reinstall the SRP module into the chassis: Install the SRP modules in slot 6 or slot 7 only for the ERX-14xx or in slot 0 or slot 1 on the ERX-7xx. Ensure that the ejectors are in the open position. Upgrading Memory on ERX-14xx and ERX-7xx Routers 7

SRP Field Upgrades Slide the module in between the guides at the top and bottom of the slot. Pushthemoduleallthewayintothechassisuntiltheejectorsareflush with the front of the chassis. CAUTION: If the module does not slide all the way into the chassis, do not force it. Carefully remove it and make sure that you are installing it in slot 6 or slot 7 and that the module is between the slot s metal guides. 12. Press the ejectors into their closed position as shown in Figure 2. 13. Tighten the module s captive screws using a Phillips screwdriver. Alternate tightening each screw until all are secure and the module is securely seated. 14. When the redundant SRP module has rebooted, issue the synchronize command to synchronize the two SRPs. The synchronize command copies all new or changed files, including release (*.rel) and configuration (*.cnf) files, from the NVS card onto the newly upgraded redundant SRP module. This maintains the current JUNOSe release and configuration running on the router. 15. When the SRP modules are synchronized, reboot the upgraded SRP module by issuing the reload command: host1#reload slot 7 16. Issue the show hardware command to check that the new components are available to the router. 17. To ensure that the contents of both modules NVS cards are synchronized after the reboot, issue the synchronize command again. 18. To switch control from the primary (nonupgraded) SRP module to the newly upgraded redundant SRP module, issue the switch command. host1#srp switch 19. Halt the nonupgraded SRP module by issuing the halt standby command. 20. Remove the nonupgraded SRP from the chassis. Follow Step 5 through Step 17 in this section. 21. Optionally, issue the switch command a second time to restore the original primary and redundant SRP configuration. 8 Upgrading Memory on ERX-14xx and ERX-7xx Routers

Upgrading SODIMMs On SRP-5 and SRP-10 modules, you must remove the two SODIMMs to perform the upgrade. You do not remove SODIMMs on the ERX-14xx SRP modules. The SODIMM sockets are close to the NVS card and have a cream ceramic connector at one edge. Some or all of the sockets may already contain SODIMMS. If you receivedepending on the number of SODIMM: 1. Locate the four SODIMM sockets on the SRP module. CAUTION: When handling modules, use an antistatic wrist strap connected to the router s ESD grounding jack, and hold modules by their edges. To not touch the components, pins, leads, or solder connections. These actions help to protect the module from damage by electrostatic discharge. Figure 3: Location of SODIMMs on the ERX-14xx and ERX-7xx Router Empty SODIMM socket SODIMM g013452 Upgrading Memory on ERX-14xx and ERX-7xx Routers 9

SRP Field Upgrades Figure 4: Location of SODIMMs on the SRP-5 and SRP-10 Cream ceramic connector Empty SODIMM socket SODIMM 1. Align notches in SODIMM and connector. 2. Push SODIMM into connector at an angle of approximately 45 degrees. NVS card 3. Push down on back edge of SODIMM until it snaps into socket. g013451 2. If you are updating an SRP-5 or an SRP-10, first remove the existing SODIMMs by pushing down on the back edge of each SODIMM to release it from the socket. 3. Gently pull up and out to disconnect each SODIMM from the connectors and remove them from the sockets. 4. Next, install the new SODIMMs by aligning the notches in the new SODIMM with an empty connector on the SRP module. For ERX-14xx upgrades, you install the new SODIMMs in the upper two empty sockets. On SRP-5 and SRP-10 modules, you install new SODIMMs in all four of the sockets. 5. Insert the new SODIMM at a 45-degree angle into the connector. Align the notch in the long gold edge of the SODIMM with the notch in the connector. When the SODIMM is completely inserted, the notch on the long gold edge will no longer be visible. 6. Press the top surface of the SODIMM downward into the socket until the socket spring snaps into place and secures the SODIMM. 7. Repeat Steps 2 through 4 with the second SODIMM. 8. If you are also upgrading the NVS or the SRP I/O module on the router, see Upgrading NVS on the ERX-1440 Router on page 13 or Upgrading the SRP I/O Module on page 11. If you are finished upgrading components or have a second SRP module to upgrade, see Attaching the New Faceplate Label on page 14. 10 Upgrading Memory on ERX-14xx and ERX-7xx Routers

Upgrading the SRP I/O Module Older routers might need to be upgraded with the enhanced SRP I/O module to run later versions of JUNOSe. The enhanced I/O module has an assembly number of 350-00033-02.A01 or greater. If the upgrade kit contains a new SRP I/O, follow this procedure to upgrade the SRP I/O module: 1. Attach the antistatic wrist strap to your wrist and connect it to one of the ESD grounding jacks on the router, located inside the front bezel and in the upper-right corner on the rear of the chassis. 2. Disconnect the cable connectors from the external timing ports and console ports on the SRP I/O module. Figure 4 shows the location of the SRP I/O module in the chassis. Figure 5: SRP I/O Module in ERX-1440 Chassis Fan tray I/O module SRP I/O module Power input module Cable management bracket Plenum g013728 3. Loosen the thumbscrews with a Phillips screwdriver. Slide the existing SRP I/O module out of the chassis and rest it on an antistatic mat with the memory sockets and NVS cards face up. Upgrading Memory on ERX-14xx and ERX-7xx Routers 11

SRP Field Upgrades 4. Remove the enhanced SRP I/O module from its antistatic bag. 5. Slide the new module into the same slot and tighten the thumbscrews with a Phillips screwdriver to secure it. 6. Reconnectthecablesforthetimingandconsoleports. 7. To upgrade the NVS, go to Upgrading NVS on the ERX-1440 Router on page 13. If you are finished upgrading components or have a second SRP module to upgrade, attach the new faceplate label as described in Attaching the New Faceplate Label on page 14. Restoring the JUNOSe Software Configuration If you saved your configuration file to a remote router before installing a new, non-redundant SRP, you can reload this configuration after the upgrade is complete provided that the new SRP supports the software release you are running. See E-series SRP Hardware Installation and Software Compatibility Guide for more information. To restore the JUNOSe software release and configuration, follow this procedure: 1. Ensure that: You have the JUNOSe software on CD-ROM or other media. You have saved the configuration file to a remote router as described in Step 3 of Upgrading a System with One SRP on page 3. 2. Install the JUNOSe software from the CD-ROM to the router. 3. Use the copy command or the FTP server to transfer the saved configuration file from the remote router to the local router. 4. Issue the factory default command: host1(config)#boot config factory-defaults 5. Issue the boot command, specifying the JUNOSe release you want to use. In the following example, x-y-z represents the release number. host1config#boot system erx40_ x-y-z.rel 6. Specify that the system should use the previously saved configuration file at the next reboot. In the example, the system will use the file named erx1440conf.cnf only at the next reboot; after that time, the system will reboot using the running configuration. host1(config)#boot config erx1440conf.cnf once 12 Upgrading Memory on ERX-14xx and ERX-7xx Routers

7. After the system has successfully rebooted, register the new components with Juniper Networks as described in Registering the Upgraded System on page 15. Upgrading NVS on the ERX-1440 Router This section describes how to upgrade NVS on the SRP-40 module in the ERX-1440 router. To replace the existing NVS card on the SRP module with an upgraded card, follow this procedure: 1. Make sure that you have an antistatic container for the old NVS before you remove it. 2. Attach the antistatic wrist strap to your wrist and connect it to one of the ESD grounding jacks on the router, located inside the front bezel and in the upper-right corner on the rear of the chassis. 3. Remove the SRP module from the chassis as described in Upgrading Memory on ERX-14xx and ERX-7xx Routers on page 3, if you have not removed it already. 4. Use a small flathead screwdriver to loosen the screws on the faceplate for the NVS card slot. remove the faceplate. See Figure 5. Figure 6: NVS Card Slot on the SRP Module NVS card Faceplate Release button g013763 5. Use the screwdriver to press the release button next to the NVS card, which releases the card from the module. 6. Slide the old NVS card out and place it in the antistatic container. Upgrading NVS on the ERX-1440 Router 13

SRP Field Upgrades 7. Insert the new NVS card into the slot, pushing it as far as it will go. It clicks when it is in place. 8. Replace the faceplate on the NVS card slot. 9. To upgrade the SRP I/O module, proceed to the Upgrading the SRP I/O Module on page 11, If you are finished upgrading components or have a second SRP module to upgrade, attach the new faceplate label as described in Attaching the New Faceplate Label on page 14. Attaching the New Faceplate Label After you have installed all the new components in your upgrade kit, attach the new faceplate label to the SRP module. The label indicates that you have installed new memory and NVS (if applicable). Follow this procedure: 1. Removethebackingonthenewfaceplatelabel. 2. Attach the label to the faceplate above the bottom ejector as shown in Figure 7 for ERX-1440 routers. Figure 7: Faceplate Label for the ERX-1440 Router XXX XXX xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Place label in this area Ejector g013783 14 Attaching the New Faceplate Label

3. You are ready to reinstall the SRP module into the chassis. Return to Step 12 in Upgrading a System with One SRP on page 3 or Step 11 in Upgrading a System with Two SRPs on page 5. Registering the Upgraded System Registering your system upgrades ensures that Juniper Networks has accurate information about your current hardware configuration if you need technical support in the future. For instructions, go to the Juniper Networks Web site at http://www.juniper.net/support/. List of Technical Publications Table 1 lists and describes the E-series document set. A complete list of abbreviations used in this document set, along with their spelled-out terms, is provided in the JUNOSe System Basics Configuration Guide, Appendix A, Abbreviations and Acronyms. Table 1: Juniper Networks E-series Technical Publications Document E-series Hardware Guide E-series Module Guide JUNOSe System Basics Configuration Guide JUNOSe Physical Layer Configuration Guide JUNOSe Link Layer Configuration Guide JUNOSe Routing Protocols Configuration Guide, Vol. 1 JUNOSe Routing Protocols Configuration Guide, Vol. 2 JUNOSe Policy and QoS Configuration Guide JUNOSe Broadband Access Configuration Guide Description Provides the necessary procedures for getting the router operational, including information on installing, cabling, powering up, configuring the router for management access, and general troubleshooting. Describes SRP modules, line modules, and I/O modules available for the E-series routers. Provides detailed specifications for line modules and I/O modules, and information about the compatibility of these modules with JUNOSe software releases. Lists the layer 2 protocols, layer 3 protocols, and applications that line modules and their corresponding I/O modules support. Provides module LED information. Describes planning and configuring your network, managing the router, configuring passwords and security, configuring the router clock, and configuring virtual routers. Includes a list of references that provide information on the protocols and features supported by the router. Describes configuring physical layer interfaces. Describes configuring link layer interfaces. Provides information about configuring routing policy and configuring IP, IP routing, and IP security. Describes BGP routing, MPLS, BGP-MPLS VPNs, and encapsulation of layer 2 services. Provides information about configuring policy management and quality of service (QoS). Provides information about configuring remote access. List of Technical Publications 15

SRP Field Upgrades Document JUNOSe Command Reference Guide AtoM JUNOSe Command Reference Guide N to Z Release Notes JUNOSe Release Notes Description Together comprise the JUNOSe Command Reference Guide. Contain important information about commands implemented in the system software. Use to look up command descriptions, command syntax, a command s related mode, or a description of a command s parameters. Use with the JUNOSe configuration guides. In the Release Notes, you will find the latest information about features, changes, known problems, resolved problems, and system maximum values. If the information in the Release Notes differs from the information found in the documentation set, follow the Release Notes. ReleasenotesareincludedonthecorrespondingsoftwareCD and are available on the Web. Requesting Support For technical support, open a support case using the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (outside the United States). For documentation issues, fill out the bug report form located at http://www.juniper.net/techpubs/docbug/docbugreport.html. Revision History 29 October 2004 Revision 1 This product includes the Envoy SNMP Engine, developed by Epilogue Technology, an Integrated Systems Company. Copyright 1986-1997, Epilogue Technology Corporation. All rights reserved. This program and its documentation were developed at private expense, and no part of them is in the public domain. This product includes memory allocation software developed by Mark Moraes, copyright 1988, 1989, 1993, University of Toronto. This product includes FreeBSD software developed by the University of California, Berkeley, and its contributors. All of the documentation and software included in the 4.4BSD and 4.4BSD-Lite Releases is copyrighted by the Regents of the University of California. Copyright 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994. The Regents of the University of California. All rights reserved. GateD software copyright 1995, the Regents of the University. All rights reserved. Gate Daemon was originated and developed through release 3.0 by Cornell University and its collaborators. Gated is based on Kirton s EGP, UC Berkeley s routing daemon (routed), and DCN s HELLO routing protocol. Development of Gated has been supported in part by the National Science Foundation. Portions of the GateD software copyright 1988, Regents of the University of California. All rights reserved. Portions of the GateD software copyright 1991, D. L. S. Associates. This product includes software developed by Maker Communications, Inc., Copyright 1996, 1997, Maker Communications, Inc. Juniper Networks, the Juniper Networks logo, NetScreen, NetScreen Technologies, the NetScreen logo, NetScreen-Global Pro, ScreenOS, and GigaScreen are registered trademarks of Juniper Networks, Inc. in the United States and other countries. 16 Requesting Support

The following are trademarks of Juniper Networks, Inc.: ERX, ESP, E-series, Instant Virtual Extranet, Internet Processor, J2300, J4300, J6300, J-Protect, J-series,J-Web,JUNOS,JUNOScope,JUNOScript,JUNOSe,M5,M7i,M10,M10i,M20,M40,M40e,M160,M320,M-series,MMD,NetScreen-5GT, NetScreen-5XP, NetScreen-5XT, NetScreen-25, NetScreen-50, NetScreen-204, NetScreen-208, NetScreen-500, NetScreen-5200, NetScreen-5400, NetScreen-IDP 10, NetScreen-IDP 100, NetScreen-IDP 500, NetScreen-Remote Security Client, NetScreen-Remote VPN Client, NetScreen-SA 1000 Series, NetScreen-SA 3000 Series, NetScreen-SA 5000 Series, NetScreen-SA Central Manager, NetScreen Secure Access, NetScreen-SM 3000, NetScreen-Security Manager, NMC-RX, SDX, Stateful Signature, T320, T640, T-series, and TX Matrix. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. All specifications are subject to change without notice. Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Copyright 2004, Juniper Networks, Inc. All rights reserved. Requesting Support 17