Troubleshooting Guidelines

Similar documents
Chapter. Maintenance and. Troubleshooting. In This Chapter...

CHAPTER SETTING UP & USING THE EZ-ETHERNET. In This Chapter...

Ethernet Remote Master (ERM)

Configuring the T1H -EBC(100) Using NetEdit3

Introduction. In This Chapter... Manual Overview ECOM Module Introduction Frequently Asked Questions

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F)

Installation and Setup

Switched Uplink Modules

WinPLC and Serial I/O Module Installation and Operation. Manual Number: H2-WPLC-M

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

Network Client. Troubleshooting Guide

Manual Overview 2 Overview of this Publication 2 Who Should Read This Manual 2 Supplemental Publications 2 Technical Support 2 Special Symbols 2

This Datasheet for the IC697CMM741. Series MMS or TCP/IP Ethernet LAN Interface.

Troubleshooting. Diagnosing Problems CHAPTER

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

FCC Certifications. CE Mark Warning

Review For Exam 2. Internetworking. Summary Questions. School of Business Eastern Illinois University. School of Business Eastern Illinois University

Internetworking is connecting two or more computer networks with some sort of routing device to exchange traffic back and forth, and guide traffic on

Lecture 8: Switched Ethernet and Collision Domains

CTS2134 Introduction to Networking. Module : Troubleshooting

GSW User Manual. 4-Port TP + 1-Port SFP Gigabit Ethernet Switch. Ver

Chapter 8 OSI Physical Layer

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER

High Availability Architectures for Ethernet in Manufacturing

PDW30 Point-to-Point Wireless Bridge Installation Guide

PTC-101-M12 Hardware Installation Guide

Hardened Web-Smart High Power PoE Ethernet Switch

MGate MB3170/MB3270 Quick Installation Guide

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Network Client. Troubleshooting Guide

User Manual A08. User Manual

Troubleshooting. Diagnosing Problems CHAPTER

Gateway 1400 Reference Manual

Troubleshooting CHAPTER

PTC-101 Quick Installation Guide

Troubleshooting PLCs & SCADA Systems

Troubleshooting EtherNet/IP Networks

More on LANS. LAN Wiring, Interface

T1K MODBUS Base Controller Specifications

SMVector EtherNet/IP Communication Module Communications Interface Reference Guide

INSTALLATION GUIDE Maxiflex P3e CPU M1262F

The NIC is the main interface between the computer and the network cable.

Canlan Ethernet Controller. Troubleshooting Guide

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

ICF-1150 Series Quick Installation Guide

Troubleshooting. Diagnosing Problems. Check Switch POST Results CHAPTER

DeviceMaster RTS 16-Port Hardware Installation

Industrial Serial Device Server

MIU-1000 v. Revised: 4/20/2009. Copyright 2008, Traf-SYS, Inc.

Canlan INSTALLATION MANUAL

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Unable to Connect to the Master Service Processors (MSPs) Over a Low-Level Link

The specifications for the Cisco 7304 router are listed in Table A-1.

Objective: Select the appropriate media, cables, ports, and connectors to connect switches to other network devices and hosts

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

Installation and Programming Manual

Chapter 4: Network Access

NM-251D-DTM. Datum Generator - Data Multiplier User Guide V1.00

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Installation and User Guide

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

High Level View. EE 122: Ethernet and Random Access protocols. Medium Access Protocols

Quick Start Manual G2-2 Series with Ethernet Interface

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

This is an inspection failure, not meeting the requirement of >10k Ohm between either PD battery post and chassis.

Physical Layer V What does the physical layer provide?

FCC Certifications. CE Mark Warning

Port Status and Basic Configuration

Table of Contents. Page ii

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Using the Cable Monitor Tool

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

Comp277 Assignment 1 Fall 2011 Due 20 th December 2011 at 11:00am

PROFIBUS. Network Case study

MOXA EtherDevice Switch

USB RS-485/422 Communication adapter virtual serial port ELO E211. Operation manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

PLC Stamp micro EVB Datasheet

Quick Start Guide. Physical Description. The Port Status LEDs

HES-3106-PLUS SERIES

Technical Paper. Network Alternatives. Using the. ROTRONIC HW3 Software

EE 122: Ethernet and

Troubleshooting. Diagnosing Problems. Verify the Switch Module POST Results CHAPTER

Management Software AT-S67 AT-S68. User s Guide FOR USE WITH AT-FS7016 AND AT-FS7024 SMART SWITCHES VERSION PN Rev A

Review For Exam 2. Fundamentals of Data & Signals. Summary Questions. School of Business Eastern Illinois University

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

Troubleshooting. 1 Preliminary Fault Isolation Procedures. 1.1 Definitions

Ethernet to Tok. oken Ring. Monitor RINGDALE. Quick Installation Guide. Connecting people and information

Quick Start. Appearance and pin assignments

LevelOne FSW PoE Fast Ethernet Switch User Manual

USB RS-485/422 Communication adapter virtual serial port ELO E216. Operation manual

Hands-on Networking Fundamentals. Chapter 12 Maintaining and Troubleshooting Your Network

Industrial PoE Media Converter

Rugged Industrial Media Converter

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Transcription:

6 In This Chapter.... Isolating a Communication Problem Chart EBC Module Diagnostic LEDs Using NetEdit for Diagnosing Network Cable Problems

6-2 Isolating a Communication Problem If you are experiencing a problem communicating with an EBC module, the problem can usually be isolated to one of four components of the communication link: the EBC module itself (hardware or firmware) the communication program or the setup of the EBC module the cabling and connections other external influences, such as electrical noise, heavy communication traffic on the network or exceeding the power budget Diagnostic Tools and Techniques Several available tools and techniques can help you isolate a communication problem: The LEDs on the face of the module indicate the status of the link, the module, and the network communications. Replacing the module may determine whether the problem is in the module. NetEdit3 displays a list of the active modules on the network and their protocol and configuration settings. Cable testing devices can pinpoint short or open circuits or diagnose attenuation problems and other cabling problems. Diagnostic tools within your PC-based Control software. Chart The following chart summarizes the different types of communication failures you could experience. In each case the power must be applied to the base, and you must be attempting to communicate with the EBC in question. The meaning of the diagnostic LEDs is explained begining on page 6-4. Chart Legend: Off On Flash EBC Module LEDs Corrective Action OR OR 1. Cycle power to the base. This will clear the if it was due to a transient condition. 2. Replace EBC module

6-3 Chart (Continued) Legend: EBC Module LEDs Off On Flash Corrective Action 1. Try another cable that you know works. Check pinouts (see page 2--8). 2. Try another port on the hub or another hub. 3. Replace EBC module. 1. Try another cable between PC and hub. 2. Try another port on the hub or another hub. 3. Make sure you have not exceeded the recommended cable length for your network cable. The link signal could arrive with sufficient strength even though the data transmission does not. 4. Could be related to Windows configuration. Consult Windows documentation. Note: This is also the indication of proper operation! Troubleshoot only if you are failing to exchange data. OR 1. Try another cable between PC and hub or EBC and hub. 2. Try another port on the hub or another hub. 3. Look for errors in the setup of the EBC module. OR

6-4 EBC Module Diagnostic LEDs EBC LEDs The EBC module has three indicator lights which show the status of the following: signal path between the EBC and the hub signal between a PC and an EBC EBC module hardware H2 -EBC and H2 -EBC -F H4 -EBC( -F) LINK GOOD IVITY LINK GOOD IVITY The green (LINK GOOD) LED is on steady when the EBC module is connected properly to an active device on the network and is receiving 5VDC operating voltage from the PLC power supply. The LED verifies that the proper cables are connected, and the EBC module is functioning correctly. If a mismatch with the 10BaseT or 10BaseFL connections occurs this LED will not be illuminated. The red (IVITY) LED flashes to indicate that the module is detecting data on the network. If any network device is sending or receiving data, the LED will be illuminated. In idle mode (no network traffic) this LED is OFF. During heavy communication loads this LED will be on steady. If the EBC module s red indicator is flashing or on steady, a fatal error has occurred. The error may be in the EBC module itself, or a network problem may be causing this symptom. The indication can be caused by a faulty ground, an electrical spike or other types of electrical disturbances. Cycle power to the system to attempt clearing the error.

6-5 100MBIT TXD RXD LINK GOOD The green LED is on steady when the EBC module is receiving 5VDC operating voltage from the PLC power supply and self diagnostics indicates the module is functioning properly. The green (LINK GOOD) LED is on steady when the EBC module is connected properly to an active device on the network and is receiving 5VDC operating voltage from the PLC power supply. The LED verifies that the proper cables are connected, and the EBC module is functioning correctly. If a mismatch with the 10BaseT or 10BaseFL connections occurs this LED will not be illuminated. IVITY 100MBIT Serial TXD Serial RXD The green (IVITY) LED flashes to indicate that the module is detecting data on the network. If any network device is sending or receiving data, the LED will be illuminated. In idle mode (no network traffic) this LED is OFF. During heavy communication loads this LED will be on steady. If the EBC module s red indicator is flashing or on steady, a fatal error has occurred. The error may be in the EBC module itself, or a network problem may be causing this symptom. The indication can be caused by a faulty ground, an electrical spike or other types of electrical disturbances. Cycle power to the system to attempt clearing the error. The green 100M (100MB) LED is on steady when Ethernet data is detected at 100BaseT frequency. The green TXD (Serial TXD) LED flashes when the EBC s serial port is transmitting data. The green RXD (Serial RXD) LED flashes when the EBC s serial port is receiving data.

6-6 Using NetEdit3 for Select a Module NetEdit3 is a software utility which came with this manual. To review the procedures for running and using NetEdit3, see Chapter 3. NetEdit3 allows you to: See active modules on the network. Examine and change the modules configuration settings. See the firmware revision number. Review statistical information about communication errors by type. You can also use your PC s DOS Ping command to verify communications with a network server. The PC s NIC must have the TCP/IP protocol enabled and the server must have a valid IP address. Visit www.microsoft.com for inforamtion on the Ping command. The Module box shows the Ethernet Addresses of all modules which are currently linked to the NetEdit3 utility. If your EBC module is not on this list, try the following: Change Protocol selection and click on Query Network. See Change Protocol on the next page. Confirm that your PC has IPX or TCP/IP protocol loaded. Confirm that the EBC module s Link Good LED is on. NOTE: The Ethernet Address (MAC) is permanently assigned at the factory, and it is printed on a label on the side of the EBC module. See page 3--13 if you need help locating the label. Module Info> General Information When the Module Info tab is selected, the General Info box lists the selected module s Firmware Revision, Booter Revision, DIP Switch Setting, PWB Revision, PLD Revision and CPU Revision. This box is in the lower left section of the NetEdit3 screen.

6-7 Change Protocol Ethernet Stats If you are experiencing a problem communicating from your PC to a module that does not appear on the list of active modules, try changing the protocol and clicking on Scan Network. You may be able to link to your module with the other protocol. If you are not sure which protocol driver is loaded on your PC, refer to page 3--4, as well as your Windows documentation. If you are able to see the problem module on the list of modules currently active on the network, you can select the module to see the Ethernet Stats for that module. Select the module by clicking on the Ethernet Address in the Module box. To begin a new statistical record, click the Clear Stats button. The diagnostic information available in the Ethernet Stats box is: Replacing the EBC Module Missed Frames -- frames lost due to unavailability of buffer space. TX Collisions -- detected when RXD+ and RXD-- become active during a data transmission. Two devices are trying to communicate at the same time. Lost Packets -- packets that overflow the queue. Bad Packets -- packets that fit the Ethernet standard but are not in the right format for the EBC module. Unknown Type -- a foreign command was received and could not be interpreted. This will probably happen only during software driver development. Send Errors -- the Ethernet standard number of retries were attempted for a transmission. If you are replacing an existing EBC module with a new one, you need to set up the new module with the same Module ID as the module you are replacing. If you used the DIP switch to set the Module ID, you will need to set the DIP switch on the replacement module to the same Module ID. See page 2--3 or 2--4 to review the procedure for setting the Module ID using the DIP switch. If you set up your original EBC module using NetEdit3, you will need to duplicate the settings in the new module using the same procedures. See page 3--5 through 3--12 to review the procedures for using NetEdit3. If you set up your original EBC module using your PC-based Control software, you will need to refer to the appropriate documentation. WARNING: Your system can be damaged if you install or remove system components before disconnecting the system power. To minimize the risk of equipment damage, electrical shock, or personal injury, always disconnect the system power before installing or removing any system component.

6-8 Diagnosing Network Cable Problems If you are experiencing communication problems, swapping cables is one of the simplest diagnostic procedures you can perform. If the network operates correctly with a different cable, you have isolated and cured the problem. If possible, use a short run of cable to test the network because problems with longer cable runs can be more difficult to diagnose and are more often intermittent. If you are unable to swap cables, verify the proper operation of all other network components. You probably have a cable problem if you have verified that your: EBC module is working correctly. EBC module configuration is correct. RLL program or PC program is correct. hubs are working correctly. Windows configuration is correct. network adapter card is the correct type, and it is working correctly. It is a good maintenance practice to test network cables periodically and maintain a permanent record of cable characteristics. A number of cable test instruments are available to test 10/100BaseT and 10BaseFL networks. These instruments will check the electrical or optical characteristics of your cabling, including: Continuity -- This is a check to make sure the communication pairs are wired correctly, and that the wires are continuous from end to end. In the case of fiber optic network this is a test to be sure light is transmitted from one end of the cable to the other. Attenuation -- This refers to the amount of signal loss over the cable segment at the signal frequency of interest. The 10/100BaseT specification allows for a maximum signal loss of 11.5 decibels (db) for the entire link at the signal frequency used by 10/100Mbps Ethernet. The 10BaseFL specification calls for the optical loss in link segment to be no greater than 12.5 db. Crosstalk -- Crosstalk occurs when a signal in one pair of wires is electromagnetically coupled to an adjacent pair. This is critical for10baset networks which are susceptible to noise interference. 10BaseFL networks are virtually immune to noise interference. NOTE: Any significant difference between the cable characteristics of the transmitter and receiver can cause communication errors. Ethernet devices continually monitor the receive data path for activity as a means of verifying their link is working correctly. When the network is idle, each network device (including the EBC module) sends a periodic link test signal to verify that the network is working. If the link test signal or other network activity is not received periodically, the Link Good LED on the EBC module is turned off.