Motor protection circuit breakers

Similar documents
MOTOR & CIRCUIT PROTECTION

MOTOR PROTECTION CIRCUIT BREAKERS

Motor protection relays

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

TeSys IEC Contactors and Overload Relays

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Circuit Breakers Type CTI 25M, CTI 45MB

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

Mini Contactors & Overloads

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Push buttons and selectors

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Disconnect Switches. Safe Switching and Disconnecting

SWITCH DISCONNECTORS 11

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

3 Pole Contactors with AC operating coils

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Protection Equipment

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

3RV1 Circuit-Breakers

Datasheet SRB301ST 24V (V.2)

1492-SP Supplementary Protectors

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

60103 Circuit Breaker

Motor protection circuit breakers

WEG Contactors - CWM and CWME Series

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

K1B004TLH cam switch - 1 pole A - screw mounting

Miniature Circuit Breakers for Railway Applications

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

K1D012ULH cam changeover switch - 2-pole A - screw mounting

OsiSwitch Limit Switches Innovation through modularity

Datasheet - SRB 301LC/B-24V

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Page 5-3. Page 5-2 Page 5-3

TeSys contactors From 115 to 2750 A

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

140M C 2 N A63 KN CC GJ

Allen-Bradley 1492-RCDA4A40

DOUBLE AND TRIPLE TOUCH ACTUATORS Ø22mm Double touch with or without indicator Triple touch.

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

140M C 2 E A63 KN CC GJ

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Allen-Bradley Bulletin 100 Contactors

Supplementary Circuit Protectors Type GSB63

K1F006ALH cam switch - 6-pole A - screw mounting

Square D General Purpose Relays

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

194E FA 32 E P11 P11 6

UL 489 DIN Rail Miniature Circuit Breakers

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

ZB5FG09 flush mounted selector switch head key pos stay put

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

UL 489 DIN Rail Miniature Circuit Breakers

C E R T I F I C A T E O F C O M P L I A N C E

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RW-E. Overloads. Solid-State Overload Relays. Standard Features

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

Datasheet - SRB 402EM-24V

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Miniature Circuit Breakers and Supplementary Protectors. Contents

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Micro Contactor MA Series

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

ALLEN BRADLEY RELAY Bulletin 700-HF

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

Transcription:

Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability and accuracy of tripping. SEC. - PAGE SM up to 40A. Magnetic and thermal protection... - 4 SMRM up to 40A. Magnetic protection... - 4 SM2... and SM3... from 34 up to 00A. Magnetic and thermal protection... - 5 SMPF... breakers. Fuse monitoring function... - 5 Add-on blocks and accessories for SM... - 6 Add-on blocks and accessories for SM2... and SM3...... - 8 Dimensions... -3... - 6 Technical characteristics... - 7

Page -4 Page -4 Page -4 SMP... Motor protection Push button control Ranges 0...40A (6 choices) IEC breaking capacity Icu at 400V: from 00 to 0kA Suitable for mounting in modular panels. SMR... Motor protection Rotary knob type Ranges 0...40A (6 choices) IEC breaking capacity Icu at 400V: from 00 to 20kA Thermal and magnetic trip indicator UL 60947-4- Type E via accessory (certification obtained for range from 0. to 6.5A; pending for all the other ratings. Consult Technical support for more information). SMRM... Starter protection (magnetic only) Rotary knob type Rated current from 0.6 to 40A IEC breaking capacity Icu at 400V: from 00 to 20kA. Page -5 SM2R... Motor protection Rotary knob type Ranges 34...63A (2 choices) IEC breaking capacity Icu at 400V: 50kA UL 60947-4- Type E. Page -5 SM3R... Motor protection Rotary knob type Ranges 55...00A (3 choices) IEC breaking capacity Icu at 400V: 50kA Thermal and magnetic trip indicator UL 60947-4- Type E via accessory. SMPF... Fuse monitoring function Push button control Fixed thermal protection: 0.2A Magnetic trip threshold:.2a. Page -5 LOVATO Electric motor protection circuit breakers are suitable for new motors with high IE3 efficiency values

IEC ratings Motor protection (magnetic and thermal protection) Starter protection (magnetic protection) SMP... SMR... SM2R... SM3R... SMRM... Rated current 0...40A 0...40A 34...63A 55 00A 0. 40A Thermal protection Magnetic protection TRIP position Phase failure sensitive Padlockable in O Choice 230V 400V 440V 500V 690V 230V 400V 440V 500V 690V 230V 400V 440V 500V 690V Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics [A] ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka ka 0...0.6 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0.6...0.25 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0.25...0.4 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0.4...0.63 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0.63... 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00...6 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00.6...2.5 00 00 00 00 00 00 00 00 3 3 00 00 00 00 00 00 00 00 0 0 00 00 00 00 00 00 00 00 0 0 2.5...4 00 00 00 00 00 00 00 00 3 3 00 00 00 00 00 00 00 00 0 0 00 00 00 00 00 00 00 00 0 0 4...6.5 00 00 00 00 00 00 00 00 3 3 00 00 00 00 00 00 00 00 4 2 00 00 00 00 00 00 00 00 4 2 6.3...0 00 00 00 00 25 2.5 25 2.5 3 3 00 00 00 00 42 42 42 42 4 2 00 00 00 00 42 42 42 42 4 2 9...4 00 00 25 2.5 0 5 0 5 3 3 00 00 00 00 42 42 42 42 4 2 00 00 00 00 42 42 42 42 4 2 3...8 00 50 25 2.5 0 5 0 5 3 3 00 00 00 00 0 5 0 5 4 2 00 00 00 00 0 5 0 5 4 2 7...23 50 50 5 5 0 5 0 5 3 2 00 00 50 25 0 5 0 5 4 2 00 00 50 25 0 5 0 5 4 2 20...25 50 50 5 5 0 5 0 5 3 2 00 00 50 25 0 5 0 5 4 2 00 00 50 25 0 5 0 5 4 2 24...32 50 50 0 5 0 5 0 5 3 2 00 00 50 25 0 5 0 5 4 2 00 00 50 25 0 5 0 5 4 2 30...40 20 20 0 5 0 5 0 5 3 2 00 00 20 0 0 5 0 5 4 2 00 00 20 25 0 5 0 5 4 2 34 50 00 00 50 50 35 27 0 8 5 5 45 63 00 00 50 50 35 27 0 8 5 5 55 75 00 00 50 38 40 30 8 6 5 4 70 90 00 00 50 38 40 30 8 6 5 4 80 00 00 00 50 38 40 30 8 6 5 4 SMP... MODULAR SIZE Mounting on front of panels or in modular panels for rapid access to buttons, avoiding the opening of the door by non-technical staff. Auxiliary contacts, indicator contacts and releases compatible with modular panels. 40A IN 45mm From 0.A to 40A in a device just 45mm wide. High short-circuit breaking capacity up to 40A. Small, cost-effective starters. 45mm (.77 ) SMR... TRIP INDICATION Thermal and magnetic trip indication with trip position of knob. Specific optical indication for shortcircuit tripping; guarantees maximum safety for operators and reliability of the system. Auxiliary trip indication contacts with ability to distinguish overload from short circuit. UL Type E The entire rotary knob type is certified UL Type E (pending for ranges from 6.5 to 40A. Consult Technical support for more information). Type E is a specific requirement of the UL standards that requires, of short-circuit protection devices, increased terminal isolation distances and strict breaking capacity tests. Eliminates the need for further short-circuit protection devices upstream of the motor protection. SM... HIGH-PERFORMANCE PLASTICS IEC/EN 60335-compliant plastics for domestic and similar applications. Can be used in catering equipment. EN 45545-compliant plastics: fire behaviour and emissions of fumes. Suitable for railway applications. -2

Fuse monitoring UL508 ratings SMPF... SMP... SMR... - SM2R... - SM3R... 0.2A UL508 / UL 60947-4- Manual Motor Controller - Short circuit current in ka Motor Protection Motor Group Protection Tap Disconnect Disconnect Motor Conductor Group Motor Installation Protection Installation UL508 / UL 60947-4- Manual Self Protected Combination Motor Controller (Type E) Short circuit current in ka 230V 400V 440V 500V 690V Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics ka ka ka ka ka ka ka ka ka ka 00 00 00 00 00 00 00 00 00 00 240V 480V 600V 480V 600V 480V 600V 480Y/277V 600Y/347V 240V 480Y/277V 600Y/347V ka ka ka ka ka ka ka ka ka ka ka ka 50 50 50 Fuse or CB 50 50 50 50 Fuse or CB 50 50 50 50 50 50 50 50 Fuse or CB 50 50 50 50 Fuse or CB 50 50 50 50 50 50 50 50 Fuse or CB 50 50 50 50 Fuse or CB 50 50 50 50 50 50 50 50 Fuse or CB 50 50 50 50 Fuse or CB 50 50 50 50 50 50 50 50 Fuse or CB 50 50 50 50 Fuse or CB 50 50 50 50 50 50 50 50 Fuse or CB 50 50 50 50 Fuse or CB 50 50 50 50 50 30 30 30 00A Class J 30 30 30 30 Fuse or CB 30 30 30 30 30 30 30 30 00A Class J 30 30 30 30 Fuse or CB 30 30 30 30 30 30 30 30 00A Class J 30 30 30 30 Fuse or CB 30 30 30 30 30 30 30 30 00A Class J 30 30 30 30 00A Class J ❶ ❶ ❶ ❶ ❶ 30 30-00A Class J 30 30 30 30 200A Class J ❶ ❶ ❶ ❶ ❶ 30 30-00A Class J 30 30 30 30 200A Class J ❶ ❶ ❶ ❶ ❶ 5 5 - Fuse or CB 30 30 30 30 200A Class J ❶ ❶ ❶ ❶ ❶ 5 5 - Fuse or CB 30 30 30 30 200A Class J ❶ ❶ ❶ ❶ ❶ 5 5 - Fuse or CB 30 30 30 30 200A Class J ❶ ❶ ❶ ❶ ❶ 5 5 - Fuse or CB 30 30 30 30 200A Class J ❶ ❶ ❶ ❶ ❶ - - - - 50 0 50 0 Fuse or CB 50 0 00 50 - - - - - 50 0 50 0 Fuse or CB 50 0 00 50 - - - - - 40 0 40 0 Fuse or CB 40 0 00 40 - - - - - 40 0 40 0 Fuse or CB 40 0 00 40 - - - - - 40 0 40 0 Fuse or CB 40 0 00 40 - ❶ Pending ENCLOSURES Various types of plastic enclosures are available for rotating and buttoncontrolled motor protection circuit breakers up to 40A. Surface and flush mount. Ideal for small machines and isolated motors. IP65 (UL Type 4X) protection rating and UV-ray resistant. Very robust plastics, IK07; pass even the strict UL ball impact test. UL-certified. DOOR COUPLING HANDLES Padlockable door coupling handles for the entire rotary knob type. Make systems compliant with safety regulations. Tough, easy and quick to install. SM... PADLOCKABILITY Padlockability as standard on the entire rotary knob type and push button-controlled motor protection circuit breaker range. For greater operator safety during maintenance and bypassing of the equipment. -3

Motor protection circuit breakers SM up to 40A. Magnetic and thermal protection SMP... SMR... Order code Thermal Short circuit Qty Wt trip breaking per adjustment capacity pkg range at 400V Icu Ics [A] [ka] [ka] n [kg] Push button control. For UL ratings see page -2. SMP 006 0...0.6 00 00 0.280 SMP 0025 0.6...0.25 00 00 0.280 SMP 0040 0.25...0.4 00 00 0.280 SMP 0063 0.4...0.63 00 00 0.280 SMP 000 0.63... 00 00 5 0.280 SMP 060...6 00 00 5 0.280 SMP 0250.6...2.5 00 00 5 0.350 SMP 0400 2.5...4 00 00 5 0.350 SMP 0650 4...6.5 00 00 5 0.350 SMP 000 6.3...0 00 00 5 0.350 SMP 400 9...4 25 2.5 5 0.350 SMP 800 3...8 25 2.5 5 0.350 SMP 2300 7...23 5 5 0.350 SMP 2500 20...25 5 5 0.350 SMP 3200 24...32 0 5 0.350 SMP 4000 30...40 0 5 0.350 Rotary knob type. For UL ratings see page -2. SMR 006 0...0.6 00 00 0.320 SMR 0025 0.6...0.25 00 00 0.320 SMR 0040 0.25...0.4 00 00 0.320 SMR 0063 0.4...0.63 00 00 0.320 SMR 000 0.63... 00 00 5 0.320 SMR 060...6 00 00 5 0.320 SMR 0250.6...2.5 00 00 5 0.320 SMR 0400 2.5...4 00 00 5 0.390 SMR 0650 4...6.5 00 00 5 0.390 SMR 000 6.3...0 00 00 5 0.390 SMR 400 9...4 00 00 5 0.390 SMR 800 3...8 00 00 5 0.390 SMR 2300 7...23 50 25 0.390 SMR 2500 20...25 50 25 0.390 SMR 3200 24...32 50 25 0.390 SMR 4000 30...40 20 0 0.390 General characteristics SMP... and SMR... are modern circuit breakers with thermal and magnetic trip releases and high breaking capacity. Motor control and protection of up to 22kW (400V) are possible by choosing the suitable adjustment range, 0. to 40A. The dimensions of SMP breakers are compliant with the DIN43880 standard, allowing them to be mounted in all modular enclosures on the market. A magnetic trip indicator integrated on the SMR breakers avoids dangerous closing operations during short-circuit conditions, previously disconnected by the breaker. SMR breakers are Type E-certified according to UL 60947-4- (certification obtained for range from 0. to 6.5A; pending for all the other ratings). SMP and SMR motor protection circuit breakers are suitable for isolation in accordance with IEC/EN 60947 standards and can be padlocked in OFF position without using accessories. Their high breaking capacity consents to exclude protection fuses on the majority of the installations. Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV IEC rated frequency: 50/60Hz Maximum rated current: 40A Adjustment ranges: 6 IEC breaking capacity: See table on page -2 Heat dissipation per phase: 0.7...3.3W Magnetic tripping: 3In max.❶ Tripping class: 0A Phase failure sensitive Mechanical life: 00,000 cycles Electrical life: 00,000 cycles Mounting on 35mm DIN rail (IEC/EN 6075) Mounting position: Any IEC utilisation category: A Padlocking in OFF: Ø4mm/0.6 IEC degree of protection: IP20. Certifications and compliance Certifications obtained: culus, EAC. SMR breakers are Type E-certified (Self-Protected Combination Motor Controllers) according to UL 60947-4- (certification obtained for range from 0. to 6.5A; pending for all the other ratings). Certifications pending: CCC. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-2, IEC/EN 60947-4-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. Plastic materials compliant with standards: IEC/EN 60335 and EN 45545. ❶ 0In max for dimensions 0...0.6A and 0.6...0.25A. Motor protection circuit breakers SMRM up to 40A. Magnetic protection SMRM... Order code Rated and Short circuit Qty Wt magnetic breaking per trip current capacity pkg at 400V Rat. Trip. Icu Ics [A] [A] [ka] [ka] n [kg] Rotary knob type. For UL ratings see page -2. SMRM 006 0.6.6 00 00 0.320 SMRM 0025 0.25 3.2 00 00 0.320 SMRM 0040 0.4 5.2 00 00 0.320 SMRM 0063 0.63 8.2 00 00 0.320 SMRM 000 3 00 00 5 0.320 SMRM 060.6 2 00 00 5 0.320 SMRM 0250 2.5 33 00 00 5 0.320 SMRM 0400 4 52 00 00 5 0.390 SMRM 0650 6.5 85 00 00 5 0.390 SMRM 000 0 30 00 00 5 0.390 SMRM 400 4 82 00 00 5 0.390 SMRM 800 8 234 00 00 5 0.390 SMRM 2300 23 299 50 25 0.390 SMRM 2500 25 325 50 25 0.390 SMRM 3200 32 46 50 25 0.390 SMRM 4000 40 420 20 0 0.390 General characteristics SMRM are motor protection circuit breakers with magnetic tripping only and high breaking capacity. They are typically used to protect starters where there is a thermal relay or other overload protection. Starter control and protection of up to 22kW (400V) are possible by choosing the suitable adjustment range, from 0. to 40A. Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV IEC rated frequency: 50/60Hz Maximum rated current: 40A IEC breaking capacity: See table on page -3 Heat dissipation per phase: 0.7...3.3W Magnetic tripping: 3In max. Mechanical life: 00,000 cycles Electrical life: 00,000 cycles Mounting on 35mm DIN rail (IEC/EN 6075) Mounting position: Any IEC utilisation category: A Padlocking in OFF: Ø4mm IEC degree of protection: IP20. Certifications and compliance Certifications obtained: culus, EAC. Certifications pending: CCC. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-2, IEC/EN 60947-4-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. Plastic materials compliant with standards: IEC/EN 60335 and EN 45545. -4 Add-on blocks/ Accessories - page -6 and 7 Dimensions page -3 page -6 Technical characteristics page -7

Motor protection circuit breakers SM2... and SM3... up to 00A. Magnetic and thermal protection SM2R... Order code Thermal Short circuit Qty Wt trip breaking per adjustment capacity pkg range at 400V Icu Ics [A] [ka] [ka] n [kg] Rotary knob type. For UL ratings see page -2. SM2R 5000 34 50 50 50.000 SM2R 6300 45 63 50 50.000 Rotary knob type. For UL ratings see page -2. SM3R 7500 55 75 50 38 2.200 SM3R 9000 70 90 50 38 2.200 SM3R 9900 80 00 50 38 2.200 General characteristics SM2R... and SM3R... are modern circuit breakers with thermal and magnetic trip releases and high breaking capacity. Motor control and protection, up to 55kW (400V) are possible by choosing the suitable adjustment range, up to 00A. SM2R and SM3R breakers are Type E-certified according to UL 60947-4-. The SM2R and SM3R types are suitable for isolation according to IEC/EN 60947 standards and can be padlocked in OFF position without using accessories. SM3 has a trip function which indicates thermal and magnetic tripping. Their high breaking capacity consents to exclude protection fuses on the majority of the installations. Operational characteristics IEC rated insulation voltage Ui: 000V IEC rated impulse withstand voltage: 8kV IEC rated frequency: 50/60Hz Maximum rated current: 63A (for SM2...); 00A (for SM3...) Adjustment ranges: 2 (for SM2...); 3 (for SM3...) IEC breaking capacity: See table on page -2 and -3 Max. heat dissipation per phase: 7W Magnetic tripping: 3In max. Tripping class: 0A Phase failure sensitive Mechanical life: 50,000 cycles Electrical life: 25,000 cycles Mounting on 35mm DIN rail (IEC/EN 6075) Mounting position: Any IEC utilisation category: A Padlocking in OFF: Ø4mm/0.6 IEC degree of protection: IP20 on front. SM3R... Certifications and compliance Certifications obtained: culus, EAC. SM2 and SM3 circuit breakers are Type E-certified (Self-Protected Combination Motor Controllers) according to UL 60947-4-; for Type E certification, SM3 only with accessory SM3X90 00R. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-2, IEC/EN 60947-4-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. SMPF... circuit breakers Fuse monitoring function SMPF... Order code Fixed Short circuit Qty Wt thermal breaking per release capacity pkg current at 400V Icu Ics [A] [ka] [ka] n [kg] Push button control. For UL ratings see page -2. SMPF 0020 0.20 00 00 5 0.280 L L2 L3 General characteristics SMPF are breakers with magnetic-thermal tripping intended specifically for monitoring the status of fuses. By connecting every phase of the breaker to a fuse, when it blows, the motor protection breaks. Through the auxiliary contacts fitted on the motor protection, the blown fuses are signalled electrically. Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV IEC rated frequency: 50/60Hz Rated current: 0.2A Magnetic tripping:.2a. Mechanical life: 00,000 cycles Electrical life: 00,000 cycles Mounting on 35mm DIN rail (IEC/EN 6075) Mounting position: Any IEC utilisation category: A Padlocking in OFF: Ø4mm/0.6 IEC degree of protection: IP20. T T2 T3 Certifications and compliance Certifications obtained: culus, EAC. Certifications pending: CCC. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-2, IEC/EN 60947-4-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. Plastic materials compliant with standards: IEC/EN 60335 and EN 45545. Add-on blocks/ Accessories - page -8 Dimensions page -3 and -4 page -6 Technical characteristics page -7-5

Add-on blocks and accessories for SM SMX... SMX2... SMX4... SMX5... SMX8 200R SMX9000R SMX8 S -6 SMX3... SMX6... SMX89 02 BFX89 0 Order Characteristics Qty Wt code per pkg n [kg] Add-on auxiliary contacts. SMX 20 Front mount 2NO 0 0.06 SMX Front mount NO+NC 0 0.06 SMX2 20 Side mount 2NO 0.036 SMX2 Side mount NO+NC 0 0.06 SMX2 02 Side mount 2NC 0.036 SMX3 Side mount. Contacts 0.036 for thermal and magnetic tripping indication NO+NC SMX3 M Side mount. Contacts 0.036 for magnetic tripping indication NO+NC Undervoltage trip releases. SMX4 024 24VAC 50/60Hz 0.30 SMX4 0 0VAC 50/60Hz 0.30 SMX4 230 230VAC 50/60Hz 0.30 SMX4 400 400VAC 50/60Hz, 400VAC 60Hz 0.30 SMX5 024R❶ With early-make contacts 0.40 24VAC 50/60Hz SMX5 0R❶ With early-make contacts 0.40 0VAC 50/60Hz SMX5 230R❶ With early-make contacts 0.40 230VAC 50/60Hz SMX5 400R❶ With early-make contacts 0.40 400VAC 50/60Hz Shunt trip releases. SMX6 024 24VAC 50/60Hz 0.30 SMX6 0 0VAC 50/60Hz 0.30 SMX6 230 230VAC 50/60Hz 0.30 SMX6 400 400VAC 50/60Hz 0.30 Adjuster sealing kit. SMX8 2 With wire and lead included 0.006 IP65 (4X) padlockable door coupling handle for SMR... SMX8 200R Red/yellow complete 0.5 with rod length 200mm/7.87 SMX8B 200R Black complete with rod 0.5 length 200mm/7.87 SMX8 S❷ Support for rod 0.030 >45mm/5.7 Phase separation barriers for SMR SMX9000R For Type E as per UL508 / 5 0.06 UL60947-4- Three-phase connection busbars 45mm/.77 spacing. SMX90 32 For 2 breakers 0 0.028 SMX90 33 For 3 breakers 0 0.050 SMX90 34 For 4 breakers 0 0.07 SMX90 35 For 5 breakers 0 0.092 Three-phase connection busbars 54mm/2.3 spacing. SMX90 42 For 2 breakers 0 0.03 SMX90 43 For 3 breakers 0 0.056 SMX90 44 For 4 breakers 0 0.08 SMX90 45 For 5 breakers 0 0.090 Terminal block for busbar supply. SMX90 30 For all busbar types 0 0.048 SMX90 50 For all busbar types Type E as 0 0.033 per UL508 / UL60947-4- Safety cover. SMX90 3 For unused terminals 0 0.004 Accessories for motor protection breaker fixing. SMX89 02 Metal bracket for fixing SM... 0 0.006 motor protection with screws BFX89 0 Universal plastic base for 2 0.06 screw-fixing SM... motor protection circuit breaker Dimensions pag. -3 and 4 General and operational characteristics ADD-ON AUXILIARY CONTACTS Connectable to the left side of the breaker or on the front Maximum combinations: 3 SMX blocks with 6 auxiliary contacts in total of which front block and 2 side blocks IEC conventional free air thermal current Ith: 0A (5A for SMX...) IEC rated insulation voltage Ui: 690V (300V for SMX...) Rated impulse withstand voltage Uimp 6kV (4kV for SMX...) UL/CSA and IEC/EN 60947-5- designation: A600 - Q600 (C300 - R300 for SMX...) Maximum tightening torque: Nm / 9lbin Conductor cross section minimum-maximum ( or 2 wires): 0.75...2.5mm 2 or 8...4AWG. Screw tightening tool: Phillips 2 Maximum tightening torque: Nm / 9lbin Width of side-mount auxiliary contacts equal to 0.5 DIN 46880 modules IEC degree of protection: IP20. UNDERVOLTAGE TRIP RELEASES Snap on to the right side of the breaker Consumption inrush/holding: 2/3.5VA Release voltage: 0.35...0.7Us Operating voltage: 0.85...Us Maximum tightening torque: Nm / 9lbin Conductor cross section minimum-maximum ( or 2 wires): 0.75...2.5mm 2 or 8...4AWG. Screw tightening tool: Phillips 2 Maximum tightening torque: Nm / 9lbin Width of side-mount auxiliary contacts equal to DIN 46880 module IEC degree of protection: IP20. SHUNT TRIP RELEASES Snap on to the right side of the breaker In-rush consumption: 20VA Operating voltage: 0.7...Us Conductor cross section minimum-maximum ( or 2 wires): 0.75...2.5mm 2 or 8...4AWG. Screw tightening tool: Phillips 2 Maximum tightening torque: Nm / 9lbin Width of side-mount auxiliary contacts equal to standard DIN 46880 module IEC degree of protection: IP20. PADLOCKABLE DOOR COUPLING HANDLE FOR SMR... IEC degree of protection: IP65 Degree of protection according to UL: Type, 2, 3R, 2, 2K, 4, 4X; external use Adjustable rod from 48 to 22mm (.89 to 8.35 ) Ring-fixing in 22mm/0.87 hole. THREE-PHASE CONNECTION BUSBARS Imax 63A SMX90 3... 45mm/.77 spacing to reduce the width to the minimum SMX90 4... 54mm/2.3 spacing to consent to fit one sidemount auxiliary contact block on the breaker. TERMINAL BLOCKS FOR BUSBAR SUPPLY Imax 63A Screw tightening tool: Phillips 2 Maximum tightening torque: 2.3Nm / 20lbin Conductor cross section minimum-maximum: 4...25mm 2 or 0...4AWG. Certifications and compliance Certifications obtained: culus (except terminal block for busbar supply), EAC. Certifications pending: CCC. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-5-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. ❶ Only suitable for SMR... motor protection circuit breakers ❷ Mounting also possible with side-mount auxiliary contacts SMX2... and SMX3... page -6

Add-on blocks and accessories for SM SMX30... SMZ7 0P SMZ7 05P SMZ7 25R SMX7 40P SMX7 024R SMX7 45P SMX3... SMX32... SMZ7 02P SMZ7 5R SMX90 0 SMX90 2 new SMX7 46P new Order code Characteristics Qty Wt per pkg n [kg] Rigid SM breaker-contactor connections. SMX30 40P For motor protection breaker 0 0.09 SMP... with BG mini-contactors SMX3 4P For motor protection breaker 0 0.035 SMP... with BF09..25A contactors SMX32 4P For motor protection breaker 0 0.045 SMP... with BF26..38A contactors (max 32A) SMX30 40R For motor protection breaker 0 0.09 SMR... with BG mini-contactors SMX3 4R For motor protection breaker 0 0.035 SMR... with BF09..25A contactors SMX3 42R For motor protection breaker 0 0.044 SMR... with contactors BF09..25D and BF09 25L SMX32 4R For motor protection breaker 0 0.045 SMR... with contactors BF26..38A (max 32A) Surface mount enclosures IP65 (4X) for SMP... SMZ7 0P Width 80mm/3.5 ❷ 0.235 SMZ7 02P Width 80mm/3.5. With button 0.275 for emergency stop SMZ7 P Width 00mm/3.94 ❷ 0.35 SMZ7 2P Width 00mm/3.94. With 0.345 button for emergency stop Flush mount enclosure IP65 (4X) for SMP... SMZ7 05P Width 87mm/3.42 ❷ 0.205 Surface mount enclosures IP65 (4X) for SMR... SMZ7 5R With rotary actuator 0.350 red/yellow. Width 00mm/3.94 SMZ7 0R With black rotary actuator 0.350 Width 00mm/3.94 Flush mount enclosures IP65 for SMR (UL type 4X) SMZ7 25R With rotary actuator yellow/red 0.245 Width 87mm/3.42 SMZ7 20R With rotary actuator black 0.245 Width 87mm/3.42 ENCLOSURE ACCESSORIES AND SPARE PARTS. For SMZ...P enclosures. SMX7 40P Emergency stop 0.044 button. IP65 (4X) SMX7 45P Rubber membrane 0.06 with rim. IP65 (4X) SMX7 46P Lockable block. IP65 (4X) 0.030 LED pilot lights IP65. SMX7 024G Green 24VAC/DC 0.007 SMX7 024R Red 24VAC/DC 0.007 SMX7 400G Green 0...400VAC 0.007 SMX7 400R Red 0...400VAC 0.007 Plastic M25 to ½ NPT entry adapter. LM M25 PG6 For enclosures SMZ7 0P 0 0.009 and SMZ7 02P Starter assembly adapter plates. SMX90 0 Adapter plate for direct starter 0.058 comprising breaker SM... and contactor BG..., BF09A...BF38A SMX90 2 Adapter plate for reversing 0.095 switch comprising breaker for motor protection SM contactors BG..., BF09A...BF38A SMX90 4 Adapter plate for starter 0.8 star-delta comprising motor protection breaker SM... and contactors BF09A...BF38A SMX90 8 35mm rail for passage 0.025 of wires underneath to contactor; for SMX90 4 SMX90 9 DIN rail extension 0.025 35mm/.38 General and operational characteristics RIGID SM BREAKER-CONTACTOR CONNECTIONS The SMX3 connections electrically and mechanically fasten the motor protection breaker together with the contactor. This forms a highly compact single-unit starter for quick installation on a single 35mm DIN rail. The SMX3 connections can also be mounted in combination with reversing switches and star-delta starters made with the rigid connections indicated in section 2. SURFACE MOUNT ENCLOSURES Top or bottom entry: SMZ7 0P and SMZ7 02P 4 M25-threaded knockouts SMZ7 P and SMZ7 2P 4 threaded knockout with Ø20.5mm/0.8 or Ø26.5mm/.04 SMZ7 0R e SMZ7 5R 4 threaded knockout with Ø20.5mm/0.8 or Ø26.5mm/.04 Possibility of rear entry too Protection rating: IP65 (UL Type 4X) Holds a breaker, one front-mount auxiliary contact block either one shunt or undervoltage release and one pilot light; only for SMZ7 0R and SMZ7 5R, 2 side-mount auxiliary contact blocks can be fitted as well The SMZ7 0R and SMZ7 5R rotary actuators can be padlocked with a maximum of 3 padlocks Ø4...8mm/0.6...0.3 Earth/ground terminal included Operating temperature: -25 +60 C Storage temperature: -50...+80 C. FLUSH MOUNT ENCLOSURES FOR SMP AND SMR Holds a SMP breaker, one front-mount auxiliary contact block and either one shunt or undervoltage release Protection rating: IP65 (UL Type 4X) Earth/ground terminal included 70x5mm/2.76x4.53 cutout for SMP 70x43mm/2.77x5.65 cutout for SMR Operating temperature: -25 +60 C Storage temperature: -50...+80 C. ENCLOSURE ACCESSORIES Emergency stop button: Turn to release Red button Ø35mm/.38. Lockable block: Prevents closing operation; 3 padlocks maximum Ø4...8mm/0.6...0.3. STARTER ASSEMBLY ADAPTER PLATES These accessories permit the assembly of starters, making slim and compact equipment that s easy and quick to install. The starter adapter plates install on DIN rail 35mm/.38. Certifications and compliance Certifications obtained: culus except SMX7 024..., SMX7 400..., SMX90... and LM M25 PG6), EAC. Certifications pending: CCC for rigid connections and enclosures (maximum current enclosures for culus: 25A). Compliant with standards: IEC/EN 60947-, IEC/EN 60947-5-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. For curus pilot lights, please contact Technical support (Tel. 035 4282422; E-mail: service@lovatoelectric.com). ❶ Complete with required voltage. Available voltages: AC 50/60Hz 24/0/220...240VAC (indicate 220)/ 380...45VAC (indicate 380). ❷ Complete with rubber membrane. Dimensions page -3, 4 and 5 page -6 Technical characteristics page -7-7

Add-on blocks and accessories for SM2... and SM3... SM2X... SM2X2... SM2X3 SM2X4... SM2X6... SM2X8... Order Characteristics Qty Wt code per pkg n [kg] Add-on auxiliary contacts. SM2X 20 Front mount 2NO 0 0.020 SM2X Front mount NO+NC 0 0.020 SM2X 02 Front mount 2NC 0 0.020 SM2X2 20 Side mount 2NO 2 0.040 SM2X2 Side mount NO+NC 0 0.040 SM2X2 02 Side mount 2NC 2 0.040 SM2X3 Side mount. 2 0.040 Indicator contacts for thermal and magnetic tripping NO+NC Undervoltage trip releases. SM2X4 230 230VAC 50/60Hz 5 0.00 SM2X4 400 400VAC 50/60Hz 5 0.00 SM2X4 440 440VAC 50/60Hz 5 0.00 Shunt trip releases. SM2X6 024 24VAC 50/60Hz 5 0.00 SM2X6 0 0VAC 50/60Hz 5 0.00 SM2X6 230 230VAC 50/60Hz 5 0.00 SM2X6 400 400VAC 50/60Hz 5 0.00 SM2X6 440 440VAC 50/60Hz 5 0.00 Padlockable IP65 (4X) door coupling handle for SM2R and SM3R. SM2X8 200R Red/yellow complete 0.5 with rod length 200mm/7.87 SM2X8 B200R Black complete with rod 0.5 with rod length 200mm/7.87 Phase separation barriers set for SM3R SM3X90 00R For Type E as per UL508 0.75 General and operational characteristics ADD-ON AUXILIARY CONTACTS Insert on the top front or snap on the left side of the breaker Maximum combinations: 3 SMX blocks with 6 auxiliary contacts in total of which front block and 2 side blocks IEC conventional free air thermal current Ith: 0A (5A for SM2X...) IEC rated insulation voltage Ui: 690V (250V for SM2X...) UL/CSA and IEC/EN 60947-5- designation: A600 Q300 (B300 - R300 for SMX...) Conductor cross section minimum-maximum ( or 2 wires): 0.75...2.5m or 8...4AWG Screw tightening tool: Pz 2 Maximum tightening torque:.2nm / 0bin Width of side-mount auxiliary contacts equal to 0.5 DIN 46880 modules. UNDERVOLTAGE TRIP RLEASES Snap on to the right side of the breaker for motor protection Consumption in-rush/holding: 8.5/3VA Release voltage: 0.35...0.7Us Operating limits: 0.85...Us Conductor cross section minimum-maximum ( or 2 wires): 0.75...2.5mm 2 or 8...4AWG Screw tightening tool: Pz 2 Maximum tightening torque:.2nm / 0lbin Width of side-mount auxiliary contacts equal to DIN 46880 module. SHUNT TRIP RELEASES Snap on to the right side of the breaker In-rush consumption: 20VA Operating limits: 0.85...Us Conductor cross section minimum-maximum ( or 2 wires): 0.75...2.5mm 2 or 8...4AWG Screw tightening tool: Pz 2 Maximum tightening torque:.2nm / 0lbin Width of side-mount auxiliary contacts equal to standard DIN 46880 module. PADLOCKABLE DOOR COUPLING HANDLE FOR SM2R and SM3R IEC degree of protection: IP65 Degree of protection according to UL: Type, 2, 3R, 2, 2K, 4, 4X; external use Adjustable rod from 48 to 22mm (.89 to 8.35 ) Ring-fixing in 22mm/0.87 hole. Certifications and compliance Certifications obtained: culus, EAC. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-5-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. -8 Dimensions page -6 page -6

Add-on blocks and accessories for SM Combinations SMX9000R SMX4... SMX5... SMX2... SMR... SMX2... SMX... SMX3 SMX6... SMX2... SMX3 M SMX2... SMP... SMX... SMX3 Only suitable for SMR... motor protection circuit breakers SMX3 M SMX3 M Three-phase connection busbars. SMX90 30 SMX90 35 SMX90 3 SMX90 34 Three-phase connection busbar, 45mm/.77 spacing (breakers without add-on blocks). SMX90 32 SMX90 33 SMX90 45 SMX90 30 SMX90 3 SMX90 44 SMX90 43 SMX90 42 Three-phase connection busbar, 54mm/2.3 spacing (breakers with add-on blocks) Dimensions page -3 and 4 page -6-9

Add-on blocks and accessories for SM Combinations Rigid SMP... breaker - contactor connections. SMP... SMP... SMP... SMX30 40P SMX3 4P SMX32 4P BG... BF09A...BF25A BF26A...BF38A Rigid SMR... breaker - contactor connections. SMR... SMR... SMR... SMX30 40R SMX3 4R❶ SMX3 42R❷ SMX32 4R BG... BF09...BF25 BF26A...BF38A ❶ For BF09A...BF25A contactors. ❷ For BF09D BF25D and BF09L BF25L contactors. Padlockable door coupling handle. SMR... SMX8 S❸ SMX8 200R SMX8B 200R ❸ Mounting also possible with side-mount auxiliary contacts SMX2... and SMX3... -0 Dimensions page -3 and 4 page -6

Add-on blocks and accessories for SM Combinations Surface mount enclosures for SMP... Width 80mm. Surface mount enclosures for SMP... Width 00mm. SMZ7 02P SMZ7 2P SMZ7 0... SMX7024... SMX7400... SMX7024... SMX7400... SMX4... SMX6... SMZ7 0P SMZ7 P SMX4... SMX6... SMX4... SMP... SMX4... SMX... SMP... SMX... SMX...❶ SMX...❶ ❶ Contacts for magnetic tripping indication SMX3 M when mounted in SMZ7 P and SMZ7 2P, can t be mounted alone, but shall be mounted in combination with SMX2... on SMX 3. Flush mount enclosures for SMP... Width 87mm/3.42. Surface mount enclosures for SMR... Width 00mm/3.94. SMZ7 05P SMZ7 0R SMZ7 5R SMX7024... SMX7400... SMX7024... SMX7400... SMX4... SMX6... SMP... SMX4... SMX... SMX4... SMX5... SMX6... SMX4... SMX... SMX... SMR... SMX... Flush mount enclosures for SMR... width 87mm/3.42. SMZ7 20R SMZ7 25R SMX7024... SMX7400... LPML... LPC ZS... SMX4... SMX5... SMX6... SMX4... SMR... SMX... Dimensions page -3, 4 and 5 page -6 -

L L Add-on blocks and accessories for SM2... and SM3... Combinations Combinations of SM2... and SM3... motor protection circuit breakers Padlockable door coupling handle. SM2X4... SM2X6... Lovato Lovato SM2... SM3... SM2X... SM2... SM3... SM2X3 SM2X8 200R SM2X8B 200R SM2X2... SM2X2... SM2X2... MAXIMUM UL/CSA HORSEPOWER RATINGS Single-phase Three-phase, 3-pole 0V-20V 220V-240V 200V-208V 220-240V 440/-480V 550V-600V [HP] [HP] [HP] [HP] [HP] [HP] SMR006 SMP006 SMR0025 SMP0025 SMR0040 SMP0040 SMR0063 SMP0063 SMR000 SMP000 /2 /2 SMR060 SMP060 /0 3 /4 SMR0250 SMP0250 /6 SMR0400 SMP0400 /8 SMR0650 SMP0650 /4 /3 /2 3 /4 /2.5 3 /4 2 3 /2.5.5 3 5 SMR000 SMP000 /2.5 2 3 5 7.5 SMR400 3 /4 2 3 3 0 0 SMR800 3 5 5 0 5 SMR2300.5 3 5 7.5 5 20 SMR2500 2 3 5 7.5 5 20 SMR3200 2 5 0 0 20 30 SMR4000 3 7.5 0 0 30 30 SMP400 3 /4 2 3 3 0 SMP800 3 5 5 0 SMP2300.5 3 5 7.5 5 SMP2500 2 3 5 7.5 5 SMP3200 2 5 0 0 20 SMP4000 3 7.5 0 0 30 SM2R5000 3 0 5 5 30 40 SM2R6300 5 0 20 20 40 60 SM3R7500 5 5 20 25 50 60 SM3R9000 7 /2 20 25 30 60 75 SM3R9900 0 20 30 30 75 00-2 Dimensions page -6 page -6

Dimensions [mm (in)] SMP... with side-mount auxiliary contacts 9 (0.35 ) 80.8 (3.8 ) 8 (0.7 ) SMR... with side-mount auxiliary contacts 9 (0.35 ) 80.8 (3.8 ) 8 (0.7 ) 90 (3.54 ) 96.6 (3.92 ) 90 (3.54 ) 37.5 (.48 ) 44.4 (.75) 44.8 (.76 ) SMX2... SMX3... SMX4... SMX5... SMX6... 5.5 (0.22 ) 43.6 (.72 ) 62.2 (2.45 ) 69.6 (2.74 ) SMP... with BG mini-contactors and connection SMX30 40P 44.8 (.76 ) 75. (2.96 ) SMP... with BF09 A...BF25 A... contactors and connection SMX3 4P SMP... with BF26 A...BF38 A... contactors and connection SMX32 4P 6.6 (6.36 ) SMX30 40P 89. (7.44 ) SMX3 4P 98. (7.80 ) SMX32 4P 45 (.77 ) 80.4 (3.6 ) 45 (.77 ) 89.8 (3.53 ) SMR... with BG mini-contactors and connection SMX30 40R 44.8 (.76 ) 9. (3.59 ) SMR... with BF09 A...BF25 A... contactors and connection SMX3 4R 44.8 (.76 ) 9. (3.59 ) SMR... with BF09 D...BF25 D... contactors BF09 L...BF25 L... and connection SMX3 42R 6.6 (6.36 ) SMX30 40R 89. (7.44 ) SMX3 4R 89.3 (7.45 ) SMX3 42R 45 (.77 ) 98.5 (3.88 ) SMR... with BF26 A...BF38 A... contactors and connection SMX32 4R SMR... padlockable door coupling handle SMX8 200R or SMX8B 200R 9. (3.59 ) 34.3 (.35 ) 35 (.38 )...4 (0.04...0.6 ) SMX8 200R SMX8B 200R 94.6 (3.72 ) 90 (3.54 ) 96.6 (3.92 ) 90 (3.54 ) 37.5 (.48 ) 44 (.73 ) 44.8 (.76 ) SMX2... SMX3... SMX4... SMX5... SMX6... 5.5 (0.22 ) 98. (7.80 ) 49 (.93 ) 74.5 (2.93) 85.6 (3.37 ) SMX32 4R 65 (2.56 ) 5.5 (0.22 ) 74.5 (2.93 ) min. 56 (2.20 ) / max. 22 (8.35 ) 45 (.77 ) -3

Dimensions [mm (in)] These elements mounted with SM... breakers without side-mount auxiliary contacts These elements mounted with SM... breakers with side-mount auxiliary contacts SMX2... or SMX3 29 (.4 ) 3.5 (0.53 ) SMX90 30 SMX90 3... 3.5 (0.53 ) 29 (.4 ) 29 (.4 ) 3.5 (0.53 ) SMX90 30 SMX90 4... 3.5 (0.53 ) 29 (.4 ) SMX90 3 SMX90 3 SMX90 32 - SMX90 33 - SMX90 34 - SMX90 35 Connection busbars 45mm/.77 spacing SMX90 42 - SMX90 43 - SMX90 44 - SMX90 45 Connection busbars 54mm/2.3 spacing 45 (.77 ) 54 (2.3 ) Enclosures SMZ7 0P Enclosures SMZ7 02P 80 (3.5 ) 0 (3.98 ) 80 (3.5 ) 6.8 (6.37 ) Enclosures SMZ7 P 00 (3.94 ) 85.5 (3.37 ) 54 (6,06 ) 54 (2.2 ) 23.3 (0.92 ) 59 (6.26 ) 35 (5.3 ) 26 (4.96 ) M25 42 (.65 ) 22 (0.87 ) 35 (5.3 ) 26 (4.96 ) M2542 (.65 ) 22 (0.87 ) 0 (3.98 ) Enclosures SMZ7 2P 00 (3.94 ) 46.5 (5.77 ) 54 (6,06 ) 54 (2.2 ) 85.5 (3.37 ) 23.3 (0.92 ) 59 (6.26 ) -4

Dimensions [mm (in)] Enclosures SMZ7 05P 87 (3.42 ) 8 (0.7 ) 70.5 (2.77 ) Enclosures SMZ7 5R and SMZ7 0R 00 (3.94 ) 5 (4.53 ) Enclosures SMZ7 20R and SMZ7 25R 54 (2.2 ) 37.8 (5.42 ) 23.3 (0.92 ) 54 (6.06 ) 59 (6.26 ) 60 (6.30 ) 70.5 (2.77 ) 86 (3.38 ) 4 (.6 ) 43.5 (5.65 ) 86 (3.38 ) 32.5 (5.22 ) 5.5 (4.54 ) Cutout 87 (3.42 ) -5

Dimensions [mm (in)] SM2... with side-mount auxiliary contacts SM3... with side-mount auxiliary contacts SM2X... SM2X2... 0 (0.39 ) 7 (0.67 ) 20 (0.79 ) SM2X4... SM2X6... 22. (4.8 ) 02.6 (4.04 ) 54.5 (2.4 ) SM2X2... SM2X3 SM2X... SM2X2... 2.5 (0.49 ) SM2X4... 22.5 (0.88 ) SM2X6... 48.3 (5.84 ) 38 (5.43 ) 28.8 (5.07 ) 77 (3.03 ) SM2X... SM2X2... SM2X3 25 (4.92 ) 89 (3.50 ) 45 (.77 ) 75.5 (2.97 ) 30 (5.2 ) 40 (5.5 ) 65 (6.50 ) 55 (6.0 ) 89 (3.50 ) 45 (.77 ) 6 (4.57 ) 50 (5.90 ) 9 30 (0.35 ) (.8 ) 55 (2.6 ) SM2X3 8 7.5 (0.7 ) (0.29 ) 2.3 (4.42 ) 26.3 (4.97 ) 30.3 (5.3 ) 44.6 (5.69 ) 9 30 (0.35 ) (.8 ) 70 (2.75 ) SMX23 8 (0.7 ) 8 (0.3 ) 38 (5.43 ) 52.7 (6.0 ) 69 (6.65 ) SM2... and SM3... padlockable door coupling handle SM2X8 200R or SM2X8B 200R 34.3 (.35 ) 35 (.38 )...4 (0.04...0.6 ) SM2X8 200R SM2X8B 200R 65 (2.56 ) min. 56 (2.20 ) / max. 22 (8.35 ) 65 (2.56 ) MOTOR PROTECTION CIRCUIT BREAKERS SMP... Three-phase LINE L L2 L3 SMR... - SM2R... - SM3R... Three-phase LINE L L2 L3 SMRM... Three-phase LINE L L2 L3 CIRCUIT BREAKERS SMPF... Three-phase LINE L L2 L3 For all motor protection circuit breakers Single-phase and DC❶ LINE L L2 T T2 LOAD T3 T T2 LOAD T3 T T2 LOAD T3 T T2 LOAD T3 T T2 LOAD ❶ Consult our Technical support for DC use. ADD-ON BLOCKS For SM types Front mount auxiliary contacts SMX 20 SMX Side mount auxiliary contacts SMX2 SMX2 20 SMX2 02 SMX3 SMX3 M Side mount undervoltage trip releases SMX4... SMX5... Side mount shunt trip release SMX6... 3 23 3 2 33 4 33 43 3 4 57 65 77 85 D D O7 C U< U< 4 24 4 22 34 42 34 44 32 42 58 66 78 86 D2 D2 O8 C2 For SM2R and SM3R types Front mount auxiliary contacts SM2X 20 SM2X SM2X 02 Side mount auxiliary contacts SM2X2 SM2X2 20 SM2X2 02 SM2X3 Side mount undervoltage trip release SM2X4... Side mount shunt trip release SM2X6... 3 23 3 2 2 33 4 33 43 3 4 57 65 D C U< 4 24 4 22 2 22 34 42 34 44 32 42 58 66 D2 C2-6

Technical characteristics TYPE SMP... SMR... SM2R... SM3R... Rated insulation voltage Ui V 690 000 Rated impulse withstand voltage kv 6 Rated frequency: 50/60Hz Maximum rated current A 40 40 63 00 Number of adjustment ranges No. 6 6 2 3 Total power dissipation at maximum current W 5 5 5 5 7...20 0...38 Magnetic tripping A 3 x In❶ 3 x In 3 x In 3 x In Mechanical life cycles 00,000 00,000 50,000 50,000 Electrical life (Ie max AC3) cycles 00,000 00,000 25,000 25,000 Terminal tightening torque Nm 2.5...3 2.5...3 4.5 6 lbft.8...2.2.8...2.2 40 53 Tool PH2 PH2 PZ2 Allen 4mm Conductor section minimum and maximum ( or 2 wires) AWG No. 6 8 6 8 8...3 0.../0 Flexible without lug mm 2 0 0 0.75...25 0...50 AMBIENT CONDITIONS Temperature operating C -20...+60❷ -20...+60❷ -20...+70❷ -20...+70❷ storage C -50...+80-50...+80-50...+80-50...+80 compensation C -20...+50-20...+50-5...+40-5...+40 Maximum altitude m 3000 Mounting position Any Fixing On 35mm DIN rail On 35mm DIN rail or screw via accessory or screw E.g. PH = Phillips; PZ = Pozidriv; Allen is metric type. ❶ SMPF00 20 has a single 0.2A thermal adjustment and magnetic tripping at 6 x In (.2A). ❷ When fitting more than one breaker side by side, without leaving space between each to consent free air circulation on the breaker sides, and have simultaneous operation, the thermal trip adjuster must be positioned at a value 5% higher than the rated motor current. THERMAL TRIPPING CURVE (AVERAGE TIMES) Three-phase balanced operation Opening time [s] 0000 2h h 30min 000 0min 5min 2min 00 min Two-phase operation (phase failure/single phasing) Opening time [s] 0000 2h h 30min 000 0min 5min 2min 00 min 0 COLD 0 COLD HOT HOT 0. 0. 0.0 0.0 0.00.05.5 2 3 4 5 6 7 8 90 20 30 40 50 6070 00.2 x Ie [A] 0.00.5.5 2 3 4 5 6 7 8 90 20 30 40 50 6070 00 x Ie [A] Tripping times can have a ±20% deviation with respect to the average tripping curve value above. -7