S&C Scada-Mate Switching Systems. Specifications for S&C Current Sensors

Similar documents
1Introduction CHAPTER ONE IN THIS CHAPTER. APEX Drive Description and Block Diagram. ➀ Introduction 1

The new. Available exclusively from Richards Manufacturing

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

Elastimold Molded Vacuum Recloser - MVR

SITRANS F flowmeters SITRANS F US

ML85C. Data Sheet. Press fit monitoring module. Special features. Block. diagram PLC. B en

DNP Points List and Implementation

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

DS5000-IBFS. 5kA rms - 8kA DC Fluxgate current transducer. Features. Description. Application. Precision Innovation /

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

(12) Patent Application Publication (10) Pub. No.: US 2011/ A1

Testing Instruments Manufactured by

LPI SG + SST Spark Gap Surge Filter

ENGINEERING SPECIFICATION. 65W AC Adaptor. Part Number: PA P1

E5ZE-8 Multipoint Temperature Controller Communications Manual

DATA SHEET Selectable AC transducer, TAS-331DG

BRC SERIES 20kW High Voltage Power Supply

Specifications. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) For Remote Supervisory Control

CSI 9330 Vibration Transmitter

( ) subject to m. e (2) L are 2L+1. = s SEG SEG Las Vegas 2012 Annual Meeting Page 1

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List

The International Power Quality Resource

INSTRUCTIONS For Installation and Operation

CERTIFIED TEST REPORT

RT4F-120V/20A-WAC RECTIFIER

Multi-Target Tracking In Clutter

ES205 Analysis and Design of Engineering Systems: Lab 1: An Introductory Tutorial: Getting Started with SIMULINK

Energy & Power Quality Powermeter

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

Bulletin 1489 Circuit Breakers. Selection Guide

OVP. The Over-Voltage Protector (OVP) Technical Literature

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

RT4F-48V/50A-WAC RECTIFIER

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

Infinisolar V Hybrid-On Grid Inverter with Energy Storage

MAJOR VA Power Inverter

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Installation Instructions & Users Manual

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

IELR Rail-Mount Series Magnetic Circuit Protectors

DATA SHEET Selectable AC transducer, TAS-321 DG

2V67 Four Stage Over / Under Voltage Relay

AIR COOLED MODULAR RECTIFIER

A.C. VOLTAGE SURGE SUPPRESSOR SPECIFICATIONS (SOLID-STATE TYPE)

EMU-1. User Manual. Engine Monitoring Unit Analogue to NMEA For variant: EMU-1-BAS. Issue 1.06

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RT12-240V/2.4kW Rectifier Specification

S&C System VI Switchgear Indoor and Outdoor Distribution (15 kv through 38 kv)

PXC05-Dual Output Series: DC/DC Converter Module 9 to 75 Vdc input, 3.3 to 15 Vdc Dual Outputs, 5W

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

MINER-S Station Controller

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

IELR Series

S&C Scada-Mate Switching Systems Outdoor Distribution (14.4 kv through 34.5 kv)

COMPUTER TECHNOLOGY CO., LTD. For Approval

Practical Analog and Digital Filter Design

Laboratory Exercise 6

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Lightning & Surge Protection

Dimensional Data - Output Unit, Enclosure, and Cable Connector

Current Limiting Protector

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Lightning & Surge Protection

EDR-3000 Eaton Distribution Relay

Levine Lectronics and Lectric. Line Card. Serving Georgia, Alabama, Florida, Mississippi, Tennessee, and Arkansas

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

RT7-48V/6kW Specification

SIMIT 7. Component Type Editor (CTE) User manual. Siemens Industrial

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Rapidus Power Factor Controller

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Xitanium. Xitanium Basic Prog LED Outdoor drivers. LED driver. Datasheet. Xi BP 12W A S 230V C100


SOLOdrive AC, 30W, 0-10V + AUX, 1 control channel, constant current, 1x 55V output, side feed, long metal

Metering Devices IQ 300

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5

Daker DK Plus UPS RACK-TOWER UPS. from 1 to 10 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

OVP2. The Over-Voltage Protector 2 (OVP2) Technical Literature

VAL-CP-1S-175. Extract from the online catalog. Order No.:

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

AC/DC Peak Voltmeter, Types MU17 and MU18

Chassis Power Supplies

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

I/A Series HARDWARE Product Specifications

RT4F-110V/25A RECTIFIER

Binary output and supervision 520CSD01 Data sheet

275 Watt Medical Ultra low profile

Prime Point on Wave Energy Reducing Switchgear ( SWITCHGEAR ).

Maneuverable Relays to Improve Energy Efficiency in Sensor Networks

RT4B-110V/12A RECTIFIER

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Transcription:

Thi data heet provide pecification for S&C Current Senor particularly when the Scada-Mate Switch i ued in application where the RTU i upplied by other. S&C Scada-Mate Switche include integral enor for three-phae monitoring of line current and ingle-phae monitoring of ytem voltage. Senor for three-phae voltage ening or for voltage ening on both ide of a normally open witch are optional. All enor are of molded S&C Cypoxy contruction and erve a upport inulator for the witch live part, thereby eliminating the cot, clutter, and complexity aociated with eparately mounted enor. The current enor are aturating-type enor and do not require horting witche. Thee enor have a current ratio of 600:5 and can drive conventional current tranducer. The output of thee current enor at primary current in exce of 1600 ampere i a ditorted waveform that may affect the performance of certain fault detection cheme. See Figure 2 on page 3. The voltage enor portion of the S&C Current/Voltage Senor i a contant-current output device like a current tranformer and, therefore, primary fuing (required by voltage tranformer) i eliminated. Burden are available to provide either 5-volt ac or 69-volt ac output. A voltage limiter i alo provided inide the bae of the Scada-Mate Switch to protect the voltage enor in the event the econdary circuit i inadvertently opened or the burden i removed. For certain application, the voltage enor portion of the S&C Current/Voltage Senor i ued to provide control power input to an S&C Battery Charger and battery pack for operating the Scada-Mate Switch. In thee application, the voltage enor cannot be ued for voltage ening and cannot be ued to power any uer-upplied equipment. Typical amplification factor for voltage enor up to the 17th harmonic are provided in Figure 4 and 5. The current enor repone i eentially flat for all harmonic, therefore, no correction of econdary current harmonic meaurement i required. Superede Data Sheet dated 3-6-95 c2003 Page 1 of 5

Current Senor Type.................. Saturating iron core air-gapped Operating Temperature Range............-40ºC to +40ºC S&C Current Senor Winding, 600:5 turn ratio conductor Senor econdary terminal Control cable Output in for connection to RTU Specification apply to S&C Current Senor and to the current enor portion of S&C Current/Voltage Senor. Figure 1. Schematic of S&C Current Senor. INPUT RATINGS AND PHYSICAL CHARACTERISTICS Current, Ampere Nominal Saturation Nominal Maximum 600 1600 Voltage, Kv Impule Withtand (BIL) 60-Hz Withtand Leakage Dry Arcing 14.4 17.0 100 36 16¹ ₈ 8³ ₈ 25 29 150 60 26⁵ ₈ 12⁷ ₈ 34.5 38 200 80 37³ ₈ 16⁷ ₈ OUTPUT RATINGS Current, Nominal, Ampere ac Power, Nominal, Va Open Circuit Voltage, V ac At 900 Ampere At 12,500 Ampere Current Ratio, Nominal Angle Shift, Nominal Accuracy, for Primary Current from 60 to 200 Ampere 200 to 900 Ampere Magnitude Angle Magnitude Angle 5.0 5.0 50 480 120:1 2.0 leading 1.5% 1.5 1.0% 1.0 Meaured at the econdary terminal of the enor. The combined burden of uer-upplied equipment (tranducer, RTU, etc.) connected to the current enor output terminal on the witch control in the control unit mut be le than 1.0 va. Additional burden will affect the accuracie publihed herein. Open circuit voltage i expreed a the rm value of a ine wave having the ame peak voltage a the open circuited current enor. The accuracie hown are in percent of reading and reflect uer calibration of the current enor output uing the precie magnitude ratio and phae angle hift appropriate for each enor, and are applicable over the operating temperature range lited and under all weather condition. The precie magnitude ratio and phae angle hift for each current enor are written on the yellow card included in the Intallation and Operation Information Kit provided with the witch. The accuracie are 5% for magnitude and 4º for phae angle if the current enor ouput are calibrated uing the nominal magnitude ratio and phae angle hift. To develop overall ytem accuracy, additional tolerance mut be added to reflect uer-upplied equipment. Page 2 of 5

150 100 Current, Ampere 50 0-50 -100-150 0 5 10 15 20 25 30 35 40 45 Time, rm 3 Ka rm ymmetrical fault 9 Ka rm ymmetrical fault 16 Ka rm ymmetrical fault Figure 2. Output waveform of aturated current enor (with maximum allowable burden). Page 3 of 5

Voltage Senor Type.................. capacitor erieconnected to dry-type tranformer Surge Protection........... Internal ga-filled park gap Operating Temperature Range............-40ºC to +40ºC Voltage enor portion of S&C Current/Voltage Senor conductor Protective park gap capacitor Tranformer, 13.1:1 turn ratio Senor econdary terminal Voltage limiter in Scada-Mate Switch Control cable Output in for connection to RTU Burden in Specification apply to voltage enor portion of S&C Current/Voltage Senor. INPUT RATINGS AND PHYSICAL CHARACTERISTICS Figure 3. Schematic of voltage enor portion of S&C Current/Voltage Senor. Voltage, Kv Nominal Operating Range Impule Withtand (BIL) 60-Hz Withtand Leakage Dry Arcing 14.4 11.43 to 17.0 110 36 16 8³ ₈ 25 20.44 to 29 150 60 27¹ ₂ 12⁷ ₈ 34.5 28.3 to 38 200 80 35 16⁷ ₈ OUTPUT RATINGS Voltage, V ac Voltage Ratio, Nominal Power, -Angle Accuracy Nominal Open Circuit Nominal, Va 14.4 Kv 25 Kv 34.5 Kv Shift, Nominal Magnitude Angle 5 30 to 90 1.0 1386:1 2440:1 3389:1 88.0 leading 1.0% 1.0 69 30 to 90 11.5 126:1 212:1 276:1 1.0 leading 3.0% 1.0 For lower ytem voltage, conult the nearet S&C Sale Office. 33.2 ohm and 6.5 µf (408 ohm equivalent) burden are available to provide 5-volt ac or 69-volt ac output, repectively. Note: The nominal output lited do not preciely correpond to the nominal input rating. Open circuit voltage i expreed a the rm value of a ine wave having the ame peak voltage a the open circuited voltage enor (with the voltage limiter in place when meaured uing a true RMS voltmeter). Meaured acro the voltage enor burden on the witch control. The combined burden of uer-upplied equipment (tranducer, RTU, etc.) connected to the voltage enor output terminal on the witch control mut be le than 0.001 va for the 5-volt ac output and 2.5 va for the 69-volt ac output. Additional burden will affect the accuracie publihed herein. The accuracie hown are in percent of reading and reflect uer calibration of the voltage enor output uing the precie magnitude ratio and phae angle hift appropriate for each enor, and are applicable over the operating temperature range lited and under all weather condition. For the precie magnitude ratio and phae angle hift for each voltage enor, refer to the yellow card included in the Intallation and Operation Information Kit provided with the witch. To develop overall ytem accuracy, additional tolerance mut be added to reflect uer-upplied equipment. Page 4 of 5

25 20 Amplification Factor 15 10 5 1 0 1 3 5 7 9 11 13 15 17 Order of Harmonic Figure 4. Amplification factor v. order of harmonic, for 5-volt ac nominal voltage ening output at 25 C. Applicable to S&C Voltage Senor of all rating. 1.5 1.4 Amplification Factor 1.3 1.2 14.4 kv 1.1 25 kv and 34.5 kv 1 Figure 5. Amplification factor v. order of harmonic, for 69-volt ac nominal voltage ening output at 25 C. Applicable to S&C Voltage Senor of all rating hown. 1 3 5 7 9 11 13 15 17 Order of Harmonic Page 5 of 5