Code Dynamics, Inc. Port Splitter

Similar documents
LANCNC FTP Data Server for CNC Controls Machine Mount instructions

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Select a Data Communication Interface

Welcome! Please review before beginning your installation.

Domain 3000 Back Panel

FSM-510G Series Ethernet Management Switch Quick Start Guide

Operating Manual. 3000E NTCIP Translator Card for IQ Central. p/n Rev 3. IQ Connect for 3000E Operating Manual

Tim Hortons EI30 Ethernet Interface Circuit Board

Copy Machine Reader. Installation and Setup Guide

3: Networking Options

FSA-CU Configuration Utility Programming Guide

BioPointe Reader Installation Guide

Installation Instructions for UL Rev A

Older Compaq UPS Family - Identifying Serial Communication Cables

Installation & Operation Guide

Copyright Black Box Corporation. All rights reserved.

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

IEI emerge MicroNode Install and Setup Guide. Contents

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

MAKE SURE TO TURN OFF YOUR TRS-80 BEFORE ATTACHING NEWKEY/80 KEYBOARD RIBBON CABLE AND POWER CABLE.

Quick Start Installation Guide

Canlan INSTALLATION MANUAL

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Installation and Operation Guide. KMD 5559 CommTalk

CS485. User s Manual. Version ZYPEX, Inc.

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

SP PRO Communications LAN Connectivity

CCN-to-Ethernet Converter Installation Instructions

Sierra Radio Systems. Digital Compass. Reference Manual. Version 1.0

Installing the Cisco AS5400XM Universal Gateway

Broadband DSL Quick Start Set Up Guide

INSTALLATION INSTRUCTIONS

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

INDUSTRIAL POE SWITCH

CMX 240 Series Controller Installation Guide

CommLink IV Technical Guide

MultiConnect Adapters

A-Series Controller & Logic Boards

Connecting and Routing the Cables and Wires

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

for Fronius IG Plus V Inverters

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

SNAP-IT-PM Installation Guide

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Ethernet Interface Module

Data Broadcast Switch

Networking Instructions Transform Motorized Acoustical Banner

V-9939B MICROPHONE ADAPTER

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

ETH-4X1-G / 2X1-G / 2X1

for AE 500NX Inverters Installation Guide COMMUNICATION SETTINGS (DEFAULT) SERIAL COMMS ADDRESS 22 8 RJ45 plug Viewed from pin side ORA-W ORA

Industrial 3-Port Fast Ethernet Media Converter Switches

Installation OVERVIEW

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

ZM24x Quick-Connect Industrial Modem. User s Manual

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

Preparing to Install the Cisco AS5350XM Universal Gateway

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Basketball Shot Clock Set LX2180 Manual

SolarVu Installation Guide for Sungrow SG30KU Inverters

Installation & Operation Guide

- +-+ Fig 1 Internet Connection. SolarVu Server. Fig 2 K135 to Sunergy inverters serial connections

4.7 Expansion Module MAC00-FS1/FS4

ex-s1110-xt Gigabit Ethernet Extenders

Site Preparation. for AE250 Inverter Installation Guide. SolarVu

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

Audisey REM-PACK-8. by Intelix

Locker Controller ELS DELIVERY Technical Manual

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Integrity Instruments

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

CodeLoader. Users Guide. P/N: Rev: OCT04

WHITE PAPER. Atlona Working with RS-232. By Bill Schripsema and Josh Castro, Atlona

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

XPress DR+W Quick Start Guide

4170 POS System Installation Guide

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

-C5RS-LC RS232 EXTENDER

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

KFC-200. Installation Guide

Connecting a Cisco Input Module

2016 MacroAir Technologies Toll Free: Fax:

Installation & Operation Guide

XC300 VDSL Network Extender Owners Manual

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

M40e and M160 CIP Installation Instructions

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Industrial Media Converters

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

The following simple procedures should be performed prior to testing the 289H M relay card:

Transcription:

Code Dynamics, Inc. Port Splitter Thank you for purchasing the Port Splitter. With this product, you can utilize a single Andover port for both the modem and PC connections. This device connects to the RS232 port with the following Andover Controls products AC4+4, AC8, AC8Plus, AC256, AC256Plus, Infinity CMX and CX controllers. AC4+4, AC8, AC8Plus systems: This configuration is used when a faster baud rate is desired. Both the AC4+4 and the AC8s have modem connections separate from the C-Port and thereby allow PC/Modem connectivity simultaneously. The problem is that the original Andover modem was only 1200 baud at best and this forced the PC connection to the same baud rate. The Port Splitter allows the use of a high-speed after-market modem to be used in place of the Andover modem. The Andover modem must first be unplugged from the controller and the new Port Splitter will use the C-Port connection to connect to the new modem and PC. AC256, AC256Plus systems: Most AC256 systems already use a splitter for dual connectivity with the Andover modem and PC. In this arrangement the Port Splitter will literally take the place of it. When connected, you may place an after-market high-speed modem to achieve baud rates up to 19.2K. Some AC256Plus systems connect the Andover modem via an edge connector located at the top of the circuit board. If connected in this manner, the Andover modem already allows direct connection with a PC at higher baud rates. The benefit in using the Port Splitter is to achieve the faster dial-up baud rate via a faster modem. Infinity systems: The Infinity systems come with a 9600-baud modem. Unless you need a baud rate of 19.2K, you can continue using the Andover modem that came with the system. The Port Splitter is extremely useful where there are a limited number of ports. For CMX systems with a 1200-baud internal modem, just unplug the phone connection to it and use the Port Splitter for a higher baud rate modem. 1

Installation Instructions Step 1 Find the RS232 port that has the modem ribbon cable attached. Unplug the modem cable from the controller port. If you have a system with the modem internal on the board, just unplug the phone connection to it. Step 2 Plug the Andover modem ribbon cable into the side of the Port Splitter labeled Modem. If installing in an Infinity or AC256Plus controller, use the extended ribbon cable that came with your Port Splitter and connect the Andover side of the splitter to the Andover port on the controller board. The old style AC256 boards don t require the additional ribbon cable you can just plug the Port Splitter right into the Andover s C-Port. 2

Step 3 The Port Splitter can be mounted in any number of ways depending on your particular type of controller. If there is a bezel plate covering your circuit board then it can be attached using standard double-sided tape. Be sure there is clearance for the door to close without hitting the surface of the splitter. If installing in an Infinity CX9200, it can be mounted on the door above the Andover modem. Step 4 Connect the power cable to your Port Splitter making sure you take caution to wire each lead according to the label. Be sure to have the power supply unplugged before making any connections. The power leads will be labeled +V, G and V. The +V lead will be +12VDC with respect to the ground (G) lead. The V lead will be 12VDC with respect to the ground (G) lead. After verifying the proper connections, you may plug in the power supply. You should then see a green light on the board indicating that the power is on. 3

Step 5 At this time you can connect via the modem. If you are using an after-market modem, you should be able to connect at the speed at which your Andover port has been configured. Your non-andover modem may require you to set dip switches or run a program on it to force it to stay within the configured Andover baud rate. Consult your modem documentation regarding the modem configuration. Step 6 The RJ45 connector will be used for your PC connection. The Port Splitter comes with an 8-foot cable and DB9 adaptor to plug directly into your PC s COM port. If the provided cable is not long enough, you can use any standard Category 5 twisted pair straight through cable with a length no greater that 50 feet. CAT-5 cables are the same type used for Ethernet LANs. Although this cable is the same type used in LANs, it CANNOT be connected into your LAN. Doing so will damage your Port Splitter as well as cripple your network. Once connected into your PC, you should be able to connect to the Andover using the same baud rate that the modem now uses. The DB9 to RJ45 pin-out is as follows: RJ45 (Splitter) DB9 (PC) 1 -------------------------- 3 2 -------------------------- 5 ------, 3 -------------------------- 8 4 -------------------------- 5 ----- 5 -------------------------- 2 6 -------------------------- 7 4

Port Splitter layout within the system Conditions: The Port Splitter was designed to give the modem priority in the event that both connections are being used at once. While in this condition, the PC connection can only monitor the data between the modem and the Andover but it will not be able to send data to the Andover. Once the modem releases the carrier or hangs up, the PC connection will again send and receive as before. Additional Features: The Port Splitter also comes with an RJ11 connector to be used as a means to monitor data communications going in and out of the Andover port. This can be used for troubleshooting or monitoring traffic for Andover alarms. An optional DB9 adaptor can be purchased to provide this functionality. A standard phone cable with the length no greater than 25 feet may be used. Troubleshooting: In the event you have trouble with the Port Splitter, you may call, fax, or write us with your questions. Code Dynamics, Inc. P.O. Box 25 Woodstock, GA 30188 Email - engineering@codedynamics.com Phone (770) 592-7402 Fax (678) 445-8193 5