SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Similar documents
Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ASCO 920 Remote Control (RC) Switches

920 Remote Control (RC) Switches

Specifications, Installation, and Operating Instructions

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

INSTALLATION INSTRUCTIONS

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Quick Start Guide TS A

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Power Supply (48Vdc, 2.5A)

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Always "On" UPS Systems Inc. USER MANUAL

Line Impedance Stabilization Network (LISN)

PowerFlex 400 AC Drive Guide Specification

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Installation Instructions

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

IIM Warwick Court. Williamsburg VA REV 5

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

ASCO SERIES 300 Manual Transfer Switch Solutions

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

DeltaV Bulk Power Supplies

BSPD Surge Protective Devices

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

S66 Series Electronic Fan Speed Control

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

DeltaV Bulk Power Supplies

Thermometer / Barometer System

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

to 48V DC Power Supply

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Surge Protective Devices. STV25K Series. Instruction Manual

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

CONTROL PANEL WIRING SPECIFICATIONS

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

HomeWorks Remote Power Feed-Through Panels

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

QuantumR Light Management Hub

Sync Control. Installation/Operation Manual Rev. E

QuantumR Light Management Hub (QP2)

60103 Circuit Breaker

PGR-3200 MANUAL INSULATION MONITOR

AMP Rack User Manual. Publication Rev G

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Single Phase Systems-North American PC125/PC420 Series

PanelView Plus/VersaView CE Terminals and Display Modules

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Table of Contents. Safety. Attention. Warnings

ABL7RM24025 regulated SMPS with auto reset - 1 or 2-phase V AC - 24 V A

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

B60 Domestic Voltage Optimisation Unit

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

SCS AUTOMATION & CONTROL

Premium Online Series

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

PV Rapid Shutdown device

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

PDI Modular Compact Remote Power Panel

Three Phase Systems-International PC302-I/MTD

Expandable Power Systems

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SAVE THESE INSTRUCTIONS

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Model HM-535 Power Supply Installation and Service Instructions

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

SAVE THESE INSTRUCTIONS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

INSTALLATION INSTRUCTIONS

AL168 Series Multi-Output Power Supplies

ASCO SERIES 300 Service Entrance Power Transfer Switch

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

ZC Series Zone Monitoring Controllers

Transcription:

Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel

Bevco Engineering Company, Inc. CONFIDENTIAL AND PROPRIETARY This Bevco Engineering Company document contains confidential and proprietary information of Bevco Engineering Company. The intellectual properties contained herein may not be used or copied to the detriment of Bevco Engineering Company. The information contained in this document may not be copied without the express written approval of Bevco Engineering Company. CAUTION! Troubleshooting and servicing should be performed by a qualified electrician. WARNING! De-energize and lockout the main disconnect before servicing this panel. Table of Contents 1.0 DESCRIPTION OF OPERATION... 3 SYSTEM CONFIGURATION... 5 2.0 SPECIFICATIONS... 6 Electrical Specifications... 6 Seismic Specifications:... 6 Electrical Wiring Diagram... 6 Environmental Specifications:... 6... 6 4.0 PANEL DIMENSIONS... 7 6.0 DOCUMENT REVISION HISTORY... 8 COMPONENTS SUPPLIED WITH EACH PANEL: The IEC Main Disconnect Panel This Installation, Operations & Service Manual (3) sets of Emergency Power Off pushbuttons with 3NC contacts on each EPO Drawings and Electrical Schematics IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 2 of 8

1.0 DESCRIPTION OF OPERATION INTEGRATED ELECTRICAL CABINET This panel incorporates several features desirable for system installations to minimize down time, protect the generator electronics, and to reduce operational delays after a power outage. This product replaces the power panel, the lighting control relay box, and the Emergency Power Off controls. The panel has a main circuit breaker, Q1 with individual branch breakers for each generator and various cooling options. When the main circuit breaker is turned off, all power circuits within the panel will be de-energized except the power circuits for the Room Light control and the X-Ray ON warning lights. The conductors that are fed from other sources are wired using yellow conductors. The generators power is protected by electronic circuit breakers, Q2 and Q3, and is controlled by contactors, K2 and K6. The contactors will open with any loss of power or by pressing any Emergency Power Off (EPO) pushbutton. The K2 and K6 contactor control circuits are factory configured to automatically re-energize the generators upon restoration of facilities power. The control circuit may be re-configured to require the operator to manually restart the generators once the incoming power has been restored. This protects the sensitive electronic circuits of the generators from sags and surges that immediately follow power loss from blackouts, storms, utility reclosure operations, and out of phase automatic transfer switch operations. The SC1 cabinet power is protected by an electronic circuit breaker, Q4, and is controlled by contactor, K7. The contactor will open with any loss of power or by pressing any Emergency Power Off (EPO) pushbutton. The K7 contactor control circuit are factory configured to automatically re-energize the SC1 cabinet upon restoration of facilities power. The control circuit may be re-configured to require the operator to manually restart the SC1 cabinet once the incoming power has been restored. This protects the sensitive electronic circuits of the generators from sags and surges that immediately follow power loss from blackouts, storms, utility reclosure operations, and out of phase automatic transfer switch operations. The control circuits are low voltage 24 VDC and are fully powered from within the panel. The restart functionality and EPO circuitry is controlled with a safety relay, K10. See page 11 for detail. The white SAFETIES OK indicator light on the front of the panel is illuminated when none of the EPOs are pressed and the safety relay K10 is reset. When the white light is active, pressing the green START pushbutton will cause the Angio system to be energized. The green START button will illuminate, and the white SAFETIES OK light will go off. Pressing the STOP button will de-energize the imaging system. Any EPO pressed while the generator systems are energized will result in the immediate de-energizing of the Angio system. If an EPO is pressed at any time, the EPO must be reset which will cause the SAFETIES OK light to activate. Then the START button will activate the imaging system. IMPORTANT: If building power is removed from the panel while the system is energized, the system will re-energize when building power is restored without any human interaction. Additional provisions are made to integrate the X-Ray ON warning lights and room lighting with the X- Ray Equipment. The facility lighting panel provides 120- or 277-volt power that is controlled by contacts relays of K4 and K5 mounted in the IEC. The signal controlling the relays comes directly from the Siemens Generator/Power Cabinet. The IEC will accept signals from the generator at either 24 Volts AC or DC. IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 3 of 8

IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 4 of 8

UTILITY SUPPLY 480V 3-PHASE 180A MAX Q1 225A WIRESIZE: 4AWG- 350MCM SYSTEM CONFIGURATION KEY TO COMPONENTS: Q1 MAIN CIRCUIT BREAKER Q2 GENERATOR 2 CIRCUIT BREAKER Q3 GENERATOR 1 CIRCUIT BREAKER F2 POWER SUPPLY FUSES F4 DC CIRCUIT BREAKER G01 DC POWER SUPPLY K1 SAFETY CONTACTOR K2 GENERATOR 2 CONTACTOR K4 ROOM LIGHT RELAY K4A ROOM LIGHT RELAY 24VDC K5 X-RAY ON WARNING LIGHT RELAY K5A X-RAY ON WARNING LIGHT RELAY 24VDC K6 - GENERATOR 1 CONTACTOR K7 SYSTEM CABINET RELAY K10 SAFETY RELAY Q2 100A F2 4A Q4 30A Q3 100A G01 DC POWER SUPPLY K7 95-120A WIRE SIZE: 10-2/0AWG F4 5A SC1 DOOR SWITCH ROOM LIGHT X-RAY ON 30A MAX K2 95-120A MAX WIRE SIZE: 10-2/0AWG DC CONTROL CIRCUITS K1 SAFETY CONTACTOR K4 ROOM LIGHT RELAY K4A ROOM LIGHT RELAY 24VDC K5 X-RAY ON WARNING LIGHT RELAY K5A X-RAY ON WARNING LIGHT RELAY 24VDC K10 SAFETY RELAY EMERGENCY POWER OFF CIRCUITS X-RAY ON WARNING LIGHT 20A MAX LIGHTING POWER PANEL 120/277V K6 95-120A WIRE SIZE: 10-2/0AWG GENERATOR 2 80A MAX EPO EPO EPO ROOM LIGHTS 20A MAX GENERATOR 2 80A MAX IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 5 of 8

2.0 SPECIFICATIONS Electrical Specifications UL design and ratings of this panel require the application of wire at the 75 C ampacity ratings of NEC table 310.16. Wire rated at higher temperature ratings, such as 90 C, may be used but ONLY applied at the 75 C ampacity ratings of NEC Table 310.16. Catalog Number Incoming Voltage & Frequency Incoming Power Configuration Main Circuit Breaker Rating Regulatory Markings IECAX480V225A 480VAC, 50/60Hz 3Ø + Ground + Neutral 225 Amps culus Short Circuit Current Rating is 35,000 Amperes RMS Symmetrical @ 480V Seismic Specifications: This Integrated Electrical Cabinet has been certified by an independent California structural engineer in conformance with the shake testing requirements of ICC- AC 156. The California OSHPD number is OSP-0457-10. The seismic performance characteristics are as follows: SDS(g) 2.56; z/h 1.0 ; Ip 1.5 Electrical Wiring Diagram The Electrical Wiring Diagram is adhered to the inside of the enclosure door for convenient reference to the circuitry. A complete set of the panel drawings are also attached to the back of this manual and shipped with the disconnect panel. Environmental Specifications: FOR INDOOR USE ONLY Temperature 59-90 F (15-32 C) Humidity 30-75%, NON-CONDENSING PARTS, TECHNICAL SUPPORT AND SERVICE FOR INQUIRIES DURING INSTALLATION CONTACT BEVCO ENGINEERING, SUSSEX WI (262) 820-2400 FOR ISSUES FOLLOWING INSTALLATION, CONTACT SIEMENS UPTIME CENTER, (800) 888-7436 IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 6 of 8

4.0 PANEL DIMENSIONS Refer to the Table and Illustrations below for the physical dimensions of the panel. The panel may be recessed into the wall for semi-flush installations. See Illustrations below for typical front and side views with the mounting hole pattern. Refer to the drawing set provided with the panel for total weight and center of gravity dimensions. PANEL EXTERNAL PHYSICAL DIMENSIONS Parameter Dimensions Height 36.0 inches 914 mm Width 30.0 inches 762 mm Total Depth 9.1 inches 230 mm Enclosure Depth 8.0 inches 203 mm Mounting Hole Diameter 7/16 inches 11.1 mm Mounting Hole Width 28.5 inches 724 mm Mounting Hole Height 34.5 inches 876 mm Weight 157 pounds 71.2 kg IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 7 of 8

6.0 DOCUMENT REVISION HISTORY REV DATE AUTHOR DESCRIPTION OF CHANGE 1 04/19/2014 RJB Initial Release 2 02/28/2015 RJB Changed Artis name on first page 3 03/09/2015 XYUE Update manual based on current schematic 4 03/19/2015 JRB Added additional Provision on page 3 50 11/01/2016 DRO IEC Redesign 51 07/10/18 JT Updated system configuration data IECAX480V225A Product Data Sheet_R51 Siemens IEC Manual For AX Systems Page 8 of 8