Product Manual SZ2141

Similar documents
Product Manual SZ2144

H7625A, H7635A Humidity/Temperature Sensors

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

CDD4 Duct Carbon Dioxide Transmitter

BA/BS4S Temperature Sensor Installation & Operating Instructions

CDD4 Series Room CO2 Transmitter Installation Instructions

FCU-4 FAN COIL CONTROLLER

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

CDD Carbon Dioxide Transmitter

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

SEZ7656R1045B / SEZ7656H1045B

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Thermometer / Barometer System

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

FCU-4 FAN COIL CONTROLLER

LTEC Heat Pump DDC Controller

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel

Dual Digital Module Technical Guide

XT-9100 Technical Bulletin

CONTROLLER INSTALLATION OPERATION & QUICK START

MicroTech II Vertical Self-contained Systems Unit Controller

Measure & Control Temperature & CO2 levels with analog & digital I/O

MicroTech Unit Ventilator Controller

MC CO MODBUS ADDRESSABLE SENSOR

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

Custom Controller Installation Instructions

FCU-MULTI Modbus Fan Coil Unit Controller

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.

FX Input/Output (I/O) Modules XM07 and XM14

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller

Field selectable application type and room module series, via dip-switches on controller

Multi-Point Gas Detection and Control System

TC-9102 Series Surface Mount Temperature Controllers

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

Carbon Monoxide (CO) Gas Detection and Control System

MT400 MOTION CONTROLLER

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

WSHP-IOP-2 May Installation, Operation, and Programming. Tracer ZN510 Controller

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

2000 Series e/em Style Keypad Installation and Programming Manual

System Manager TS II Technical Guide. Requires System Manager TS II Code: SS9003 Version 1.0 and up DDC Controller Code: SS9001 Version 1.

RS-WMB, RD-WMB Wallbus Room Sensors and Displays

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

TOXALERT MODEL AIR 2000

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

Multi-Point Gas Detection and Control System

BACnet MS/TP Interface User s Guide

System-10 BTU Meter BACnet Network Interface Installation Guide

SE7600E Series. Installation Guide for Commerical HVAC Applications CONTENTS

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

USB-Link 2 Technical Guide

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

PoolPak SWHP Series ECCIII Modbus RTU BAS Interface DOCUMENT #: SVW05-ECCIIIMODBUS

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Precision humidity/temperature control/sensing

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

TC-8900 Controller Units with PM-8900 Power Modules

SE6104 Control Module

AirTest Model CN9000 Series Sensor Controller

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

Multi-Point Gas Detection and Control System

RGX COMMUNICATIONS GATEWAY

UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller

OPERATION INSTRUCTIONS

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

Submittal Data Sheet intelligent Touch Manager DCM601A71

LLR-MOD Modbus Light Level and Occupancy Sensor

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

MicroTech 2000 Water Source Heat Pump Unit Controller

Product Manual. QD2040a Ubiquity Site Gateway. Contents. Description. Features. Material List

Dip Switch settings.

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

4-step Chiller and Heat Pump Controller

TECHNICAL PRODUCT DATASHEET

PROLON INSTALLATION AND START UP GUIDE

VT8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

RWD68U Universal Controller

FX14 Field Controller

CTS-M5 TOXIC GAS TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL. Automation Components, Inc.

KP2000E/EM Series Style Keypad

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

Heatronic Introduction. BAS Integration Manual. Table of Contents

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

LTEC Unit Ventilator DDC Controller

Touchpad User Guide (Model: C-LCD-122-TL)

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

C7110C1001A / C7110D1009A WALL MODULES

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

M1000 INTELLIGENT ZONE CONTROL SYSTEM

MOD-RI Room Interface Modules with Modbus

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

clarity 3 Programmable Controller

V0STAT51P-2 Programmable Wired Controller

Transcription:

Product Manual SZ11 Refrigeration Controller Communicating Controls Description The SZ11 is a microprocessor-based refrigeration controller and alarm interface designed to control three coolers or freezers and monitor up to six additional. Features Stand-alone or network operation Independently programmable high and low limits for each input Independently programmable manual or automatic alarm reset Change of state factor with programmable hysteresis Status LEDs Relay output to activate additional auxiliary communication devices or external alarm circuit Six RTD temperature inputs Five analog inputs suitable for a broad variety of transducers Programmable defrost cycles with time or temp termination Temperature or pressure monitoring inputs Monitor compressor and door status Contents Description................................1 Features..................................1 Mounting..................................1 Wiring.................................... Setup.................................... Programming.............................. Sequence of Operations......................6 Checkout & Troubleshooting...................6 LED Description............................7 Mounting The SZ181 is designed for mounting using four #10 sheet metal screws. Prior to mounting, the jumpers should be placed. (See setup instructions.) If the unit will be stand-alone, all programming should be completed before installation. If the unit will be wired for communications, a unique address should be programmed into the unit. (See programming instructions.) 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com 1

Wiring The SZ11 terminal designations are shown below. REMOTE SENSOR WIRING The SZ11 accepts six 1000 Ω two-wire platinum sensors. Use TS100, TS001 or TS001 for freezer and cooler temperature sensing. When using TCS/Basys Controls three-wire sensors, use the black and red leads, and either clip or twist off the white lead. The wiring length should not exceed 50 ft. The SZ11 also accepts up to 5 TX1500 Series imputs for additional temperature sensing. POWERING THE SZ11 The SZ11 is powered from VAC /- 0 %. If wiring for communications, dedicated power must be used to power the SZ11. Several S-series controllers may be powered from the same transformer, provided that the transformer has enough power. Caution: Do not connect to 10VAC. When multiple TCS/Basys Controls devices are using a single transformer, the polarity of the power wiring must be maintained because all TCS devices are half-wave rectified and have common return paths. VAC POWER SZ11 REFRIGERATION CONTROLLER POWER NO1 8 - - NO 7 XMTR IN5 Aux. TX5 NO NO NO 5 DI1 DI DI DI DI5 IN 1 IN IN S OUT 1 DOOR OPEN P DOOR FREEZERS P 1 1 P FREEZER DOORS OUTPUT S SERVICE DATA OUT Aux. TX1 RS85 Aux. TX KBPS.8 9.6 Aux. TX 19. NO6 NO 7 NO 8 DI 6 NO 9 A B REF IN Aux. TX TEMPERATURE S SPARE T1 T1 T T T T T T T5 T5 T6 T6 B A REF 1 1 For communication wiring, use twisted, shielded 18 or 0 AWG. Must be run separately. VAC transformer. See powering instructions. 6 to 0 ma output. 600 ohm max. Do not power actuator with power from the controller. The controllers are half-wave rectified, whereby the power ground is common with the signal ground. 5 Sensor input wiring 18 AWG, twisted, shielded pair. Dry contact. Must not be powered. External relay. VAC Coil 7 8 -wire, to 0 ma transmitter.sensor input wiring 18 AWG, twisted, shielded pair. These may be connected together for a common transformer or they may be ran from separate transformers. 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com

DOOR R Setup BAUD RATE SELECTION The SZ11 must be programmed using a PC and TCS/Basys Controls software. A communication baud rate must be set by placing one jumper in the area shown above. This baud rate must be the same for all devices. For a.8k baud rate. For a 9.6K baud rate. For a 19.K baud rate REFRIGERATION POWER CONTROLLER POWER Aux. TX5 S OUT 1 P DOOR OPEN FREEZERS 1 P 1 P FREEZER DOORS OUTPUT S SERVICE DATA Aux. TX1 OUT RS85 Aux. TX KBPS.8 9.6 Aux. TX 19. Aux. TX TEMPERATURE S SPARE Note: for 8.8K baud, install shunts at 19.K 9.6K baud. VAC IN5 DI1 DI DI DI DI5 IN 1 IN IN IN SZ11 T1 T1 T T T T T T T5 T5 T6 T6 NO1 NO NO NO NO 5 NO6 NO 7 NO 8 DI 6 NO 9 A B REF INTERNAL TIME CLOCK When you read a controller, this screen displays the time (military time), the day of the week, the date and year the controller is using. When you click on PC Clock, these same parameters are read from the computer. When Writing a screen of parameters to a controller, click on PC Clock immediately before Write Page. This will ensure that the controller will have the proper time, day and date. OCCUPANT OVERRIDE This is the number of minutes from 0 to 55 ( hours, 15 minutes) which the controller will bring an unoccupied system occupied, when its override button is pressed. EVENT SCHEDULING There are two occupied time periods per day, and thus two time schedules (A and B). Let us say that the occupied time for a particular day is from 8:00AM to 1:00PM and from 1:00PM to 5:00PM. In the A schedule you could enter 8:00 to 1:00, and in the B schedule you could enter 1:00 to 17:00. You can reverse the A and B schedules also. You can also enter 8:00 to 17:00 for the A schedule and 0:00 to 0:00 for the B schedule. 0:00 (1:00AM) starts the day, and :00 (1:00AM) ends the day. Occupied times that span midnight have to be coordinated using two days time schedules. Note: the start of an occupied period is delayed by the power-on delay value. SZ11 screen A Programming The SZ11 must be programmed with a PC if other than factory default settings are desired. A port on the face allows local access for programming. If you plan to program the controller while it is on a network, prior to putting the controller on the network, a unique address must be set in the controller by accessing it through the port on the front. For more information on programming through the PC, consult your TCS software manuals. CONTROLLER ADDRESS To initialize a controller, you must first put the address of the controller here. You can either type in the address, or choose the particular controller by location. For controllers with multiple initialization screens, the address of the controller is only entered on the first screen. To write to multiple controllers, click on Enable Multiple Writes. A list of controllers of this type are listed by location name. Select individual controllers addresses by clicking on them. You will need to use Control -Click or Shift - Click for your selection. CHANNEL SCHEDULING (DAILY) Select defrost time periods and enter the starting times for each one. Enter duration the defrost cycle should last. Enter the temperaturelimit that will terminate the defrost cycle before full timed cycle has occurred and enter the fan hysteresis. The fan will continue to run until the temperature falls from the Temperature Limit by the amount of the Fan Hysteresis. These values pertain to all selected time periods. 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com

DELAY ON POWER On a loss of power, when the power comes back, the controller will wait this amount of time before starting to control. Different controllers in one building can have different delays so that all units don't com on at the same time. Enter a delay time (in seconds) that you want the controller to use on power-up. DI DELAY Enable the Digital Input Delay if you want the Digital Input to be present for 15 seconds before it takes effect. This can prevent cycling. Note, this delay if selected, will apply to all six digital inputs. RECOVERY Enter a Defrost Recovery Delay during which time no alarms will be triggered after coolers or freezers have completed a defrost cycle. SZ11 screen B. feature is useful for coolers and freezers during cleaning periods. Alarms can be suspended while the cleaning is done. AI The outdoor air temperature may be overridden from a PC. This would allow only one controller in a building to have an outdoor air sensor. Revelation could use this value and rebroadcast it to the remaining controllers in a building. Choose whether to use this function. You can type in a temperature that the controller will use for 10 minutes. After 10 minutes, the controller reverts back to reading its analog input. i.e. if this function is used, in practice the reading must be updated at least every 10 minutes. SZ11 screen C. S Select whether you want "DI1", "DI", "DI", "DI" "DI5" or "DI6" to be "Local" or "Remote". Local means that the controller uses its own control program when looking at these inputs. Remote means that it will take a PC to make any changes to these inputs. Digital Inputs One through five (DI1 thru DI5) can be configured to be uses in one of functions (MONITOR or ING). When a digital input is selected to be in MONITOR mode, the SZ11 just monitors that input. No control action is taken. Open refers to the input as being "Open" or "Off", and closed refers to the input as being "Closed" or "On". Digital Input 6 (DI6) can be configured to be used as MONITOR, ING or MOMENTARY TOGGLE OVERRIDE. In the "Momentary Toggle Override" mode, momentarily closing DI6 will activate an "Override" condition where all new alarms will be suspended. There is an "Override Time" to set which is adjustable from 0 to 55 minutes. This RUN TIMES Enter minimum ON run times and minimum OFF times for the cooler and freezer compressors. These times are selectable in minute increments. DI ACTION When a digital input is selected to be in ING mode, you need to select whether the "Alarm Condition" will occur when the digital input is "Open" or "Closed". The SZ11 monitors the input. When the input "Opens" or "Closes", based on your selection, an "Alarm Condition" is generated. Open refers to the input as being "Open" or "Off", and closed refers to the input as being "Closed" or "On". TEMPERATURE CALIBRATION The six temperature inputs are factory calibrated. However, depending on the application (long wire runs, etc.), there may need to be a field adjustment done to these readings. The "Adjusted Reading" is the reading that the SZ11 actually uses for control. The " Offset 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com

Value" is the number of degrees that the actual input temperature has been adjusted. For example: You measure the cooler temperature and it reads 0. The SZ11 reading is 1 and the cooler already has an offset of -.0. All you need to do is change the offset value to -.0 and you're done. The SZ11 will now read 0. The temperature inputs are scaled -0 to160 F (-0 to 71.1 C). These ranges are fixed and cannot be changed. SZ11 screen D. degrees). When the temperature reaches the High or Low limit, an alarm is generated. The alarm is automatically cleared when the temperature falls from the High Limit by the amount of the Hysteresis (for a High Alarm Condition) or when the temperature rises from the Low Limit by the amount of the Hysteresis (for a Low Alarm Condition). Note: If a High Limit is set to 160 F, it is disabled. If a Low Limit is set to -0 F, it is also disabled. S There are also five -0mA inputs available. These five inputs can be used to generate an alarm based on any -0mA signal. TEMPERATURE SETPOINTS Enter the cooler and freezer setpoints here. The setpoint high limit is the point that the compressor will turn on and the setpoint low limit is the point at which the compressor will turn off. S The SZ11 generates an "Alarm Condition" whenever any of the six RTD inputs, any of the two -0mA analog inputs or any of the two digital inputs have been programmed to generate an alarm, and that respective input is in alarm. An "Alarm" occurs when an RTD or analog input exceeds the high limit setting or falls below the low limit setting, or when a digital input opens (closes). Whenever an "Alarm Condition" occurs, the main monitoring screen shows CHECK indicating that an alarm is present. Keep in mind that any or all of these inputs can be used for monitoring purposes when alarming is disabled. The analog inputs need to be scaled, i.e. the SPAN LOW LIMIT is the value at ma and the SPAN HIGH LIMIT is the value at 0mA. The Low and High limits are adjustable from -00 to 800. A decimal point can be turned on also. Each input (AI1, AI, AI, AI and AI5) can be enabled to generate an alarm. Once enabled, you need to set a "High Limit" and a "Low Limit" (in units), and a "Hysteresis" (in percent of input span). For example, if your input was -0 to 160 F and you put in a hysteresis of 5%, the actual hysteresis would be 10 F because of the 00 F span. When the temperature reaches the High or Low limit, an alarm is generated. The alarm is automatically cleared when the temperature falls from the High Limit by the amount of the Hysteresis (for a High Alarm Condition) or when the temperature rises from the Low Limit by the amount of the Hysteresis (for a Low Alarm Condition). Note: If a High Limit is set to the maximum span setting, it is disabled. If a Low Limit is set to the minimum span setting, it is also disabled. SZ11 screen E. RTD S There are six 1000 ohm PtRTD inputs available. Each one is scaled -0 to 160 F (-0 to 71.1 C) and cannot be changed. Each input (FREEZER 1, FREEZER, FREEZER 1, FREEZER, COOL- ER and SPARE) can be enabled to generate an alarm. Once enabled, you need to set a "High Limit", a "Low Limit" (where applicable) and a "Hysteresis" (in TEMP AND AI DELAY There is an Alarm Delay Time which, when set, applied to all analog inputs (6 RTD's and 5 AI's). If no delay is desired, set the delay time to 0 minutes and 0 seconds. 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com 5

When this is done, an alarm is generated (or released) immediately when the input reaches the appropriate setting. If a delay time other than 0 minutes and 0 seconds, the SZ111 makes sure that the analog input has been at the appropriate setting for that amount of time before generating (or releasing) an alarm. Note: The time set for the Alarm Delay Time is used for all analog inputs that are set to generate an alarm. OUTPUT TIMEOUT If the relay alarm output is enabled, meaning set to normally open or closed, then you may enable an alarm timeout feature by selecting " Enable Alarm Output Timeout" from the menu. If enabling this function is chosen, you need to enter a time adjustable from 0 to 55 seconds, after which the relay output will revert back to its "Non-Alarm" state. This is useful if an audible horn is attached to the relay output. The horn can indicate the alarm condition and then automatically time out without having to have someone go through the programming menus to disable the alarm. Sequence of Operation Checkout & Troubleshooting CHECKOUT 1. Be sure to check and verify all wiring before powering the SZ11.. Turn power on. The SZ11 "Power" LED should light up. Then the Service LED will blink for 15 seconds while the electronics stabilize.. If the SZ11 has not been pre-programmed, It should be programmed at this time.. Increase and decrease the setpoints. This must be done from a PC. Observe the operation of the relay and/or analog ouput(s). 5. Note that the operation of the SZ11 will depend on how it is programmed. The SZ11 is now ready for operation. TROUBLESHOOTING Power LED will not come on Check for VAC on terminals " VAC" and "". The rest of the trouble shooting must be done with a PC and the Revelation Professional software. No communications Make sure baud rate selection jumper for the QD1010 and the SZ11 are the same, and that Revelation is configured for that same baud rate. Address 8 will always work provided that the SZ11 is NOT connected to a network. Inputs do not read correctly The SZ11 is calibrated at the factory. For the supply temperature and other temperature readings make slight adjustments (/- 1% of the input span). on "Screen D" of the SZ11 programming screens. (See Temperature Input Calibration on page.) Output operation is not correct Check programmed parameters, in particular. Defrost time duration and temperature setpoints. Check wiring. 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com 6

LED Description Fourteen LEDs on the unit allow the occupant to view the current operating status of the SZ11. POWER: This LED will be lit whenever the unit has power. : These LEDs will be lit when the corresponding relay outputs are on. Relay outputs include heating and cooling stages, fan and timeclock output. : This LED will be on whenever the unit is in an alarm state or when a freezer or cooler door is open. : This LED will be on whenever the unit is in a defrost mode. SERVICE: This LED will be on whenever the unit has a service condition. This LED also blinks on powerup until the electronics stabilize. DATA: This LED will blink when the unit is being accessed by a PC. C609 800 LAURA LANE MIDDLETON, WI 556 (800) 88-98 FAX (608) 86-90 www.tcsbasys.com 7 Rev:10