IBS IL 24 RB-LK-2MBD:

Similar documents
IBS IL 24 BK RB-T-2MBD

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

IB IL 24 DI 16 IB IL 24 DI 16-PAC

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

This data sheet is only valid in association with the IL SYS INST UM E user manual.

IBS ST (ZF) 24 BK LB-T

IB IL 24/48 DOR 2/W-XC-PAC

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

IB IL AO 2/SF... Inline terminal with two analog outputs. AUTOMATION Data sheet 6655_en_06. 1 Description

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

ILC 200 IB ILC 200 IB-PAC

PHOENIX CONTACT - 10/2009

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

PHOENIX CONTACT - 10/2006

IB IL RS 232 IB IL RS 232-PAC

IB IL IB IL PAC

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

User Manual IB IL SYS PRO UM E

PHOENIX CONTACT - 05/2007

PB IL 24 BK DIO 16/16

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

VersaPoint I/O Module

Rexroth Inline terminal with one analog output

PHOENIX CONTACT - 11/2008

PSI-MODEM-SHDSL/SERIAL

PHOENIX CONTACT

GFK-2415A March Type of sensor connection

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

AXL E IOL AO1 U M12 R

154 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

PHOENIX CONTACT - 11/2008

FL MC 10/100BASE-T/FO-660

PHOENIX CONTACT - 07/2005

VersaMax IP Input Module

PSI-MOS-RS422/FO 850 T

PSI-MOS-PROFIB/FO 850 T

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

FL MC 2000E (SM40) LC

onlinecomponents.com

PHOENIX CONTACT - 06/2006

Extract from the online catalog

Automation terminals of the Inline product range. User manual

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

VersaMax IP I/O Module

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

PHOENIX CONTACT - 02/2007

PHOENIX CONTACT - 07/2006

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E)

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

IBS RT 24 BK RB-T. Extract from the online catalog. This item is no longer available. Should you have any questions, please contact our Sales Team.

PSI-MOS-PROFIB/FO 850 T

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

Type IBS EVA BASIC IBS EVA ADDITION 1 IBS EVA ADDITION 2 IBS SIG PART 2 UM IBS SIG PART 2 UM E. length: 50 mm acc. to RS x 9-pin D-SUB

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

ILB BT ADIO 2/2/16/16

onlinecomponents.com

PHOENIX CONTACT Features

IL CAN BK-TC-XC-PAC. Inline CANopen bus coupler Extreme conditions version. Data sheet _en_01. 1 Description

MINI MCR-SL-UI-2I(-SP)(-NC)

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

PHOENIX CONTACT - 04/2008

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Edition. MOVIDRIVE DFI21A Fieldbus Interface. INTERBUS with Fiber Optic Cable 10/2000. Manual / EN

Extract from the online catalog

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

QUINT-PS/ 1AC/24DC/ 5

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI-PS AC/10-15DC/8

Brief instruction. Version. 3en.

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

TRIO-DIODE/12-24DC/2X10/1X20

Valueline Industrial PC

Fiber optic converter audio and CAN TA OPERATION MANUAL

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

IL EIP BK DI8 DO4 2TX-PAC

QUINT-PS-3x AC/24DC/10

Extract from the online catalog

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Remote Process Actuation Control System AirLINE PHOENIX INLINE

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

8 24 V DC, 8 24 V DC,

PHOENIX CONTACT

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PHOENIX CONTACT - 01/2008

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

Transcription:

Inline Branch Terminal for an INTERBUS Remote Bus; Connections Using Fiber Optics RC D RD LD RB-LK FO AUTOMATIONWORX X2 X1 OUT Data Sheet PHOENIX CONTACT - 08/2005 Description The branch terminal is designed for use within an Inline station. The terminal offers the possibility of expanding the INTERBUS network by additional system levels. In total up to 15 levels can be operated in the network. Snapping on the branch terminal to an INTERBUS bus coupler, a control terminal or a branch terminal opens a remote bus branch at this preconnected terminal. The IBS IL 24 RB-LK (-2MBD) terminal is the first terminal in the remote bus branch. The branch terminal has an outgoing fiber optic remote bus interface and a combined remote bus branch/local bus interface (Inline data jumper) additionally. If an additional branch terminal (IBS IL 24 RB-LK or IBS IL 24 RB-T) is snapped onto this interface, it opens a remote bus branch. If any other device is snapped on, the interface opens a local bus. The functions of the IBS IL 24 RB-LK and IBS IL 24 RB-LK-2MBD terminals are identical. The essential difference between them is the transmission speed. IBS IL 24 RB-LK: IBS IL 24 RB-LK-2MBD: 500 kbaud 2 MBaud Further differing technical data are particularly identified. For greater clarity, the designation IBS IL 24 RB-LK is used throughout this document. This data sheet is only valid in association with the "Configuring and Installing the INTERBUS Inline Product Range" user manual IB IL SYS PRO UM E. Please note the "Configuration Notes" on page 5 to avoid configuration errors. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for the terminals listed under "Ordering Data" on page 11. 7181_en_00 PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg Germany 1 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com www.phoenixcontact.com/salesnetwork

Local Diagnostic and Status Indicators and Remote Bus Connections Local Diagnostic Indicators RC D RD LD FO RB-LK X1 X2 OUT IN Des. Color Meaning D Green Diagnostics RC Green Remote bus cable check RD Yellow Remote bus disabled LD Yellow Remote bus branch/local bus disconnected LD Red Isolated disconnection of remote bus branch/local bus disconnected after error FO Yellow Status of the outgoing fiber optic path RD ON: The fiber optic remote bus is disabled. Possible causes: This interface or a preconnected interface has been switched off. INTERBUS is not running (is not in the RUN state). If, in the event of an error, the preconnected bus terminal disconnects its remote bus branch/local bus interface in isolation, the RD and LD LEDs light up on this RB-LK. For the function description of all other LEDs, please refer to the "Configuring and Installing the INTERBUS Inline Product Range" user manual. 7181A002 Remote Bus Connections Designation Connection Figure 1 Local diagnostic and status indicators and remote bus connections X1 OUT X2 IN Transmit data of outgoing remote bus Receive data of outgoing remote bus Function Identification Gray 2 MBaud: white stripe in the vicinity of the D LED 7181_en_00 PHOENIX CONTACT 2

Connecting the Remote Bus Cables Internal Circuit Diagram INTERBUS Sµpi3 OPC A B +U L U ANA LGND X1 OUT X2 IN 24 V 5V Figure 2 Connecting the remote bus cables Please refer to the Fiber Optic Installation Guidelines DB EN IBS SYS FOC ASSEMBLY (Part No. 94 23 43 9) when assembling optical fibers. Connect the fiber optic remote bus cable to the terminal using F-SMA connectors. Fit the corresponding F-SMA connectors to the fiber optic cables. Place the connectors into the appropriate connections. Secure the connections with the cap nuts. The label for the fiber optic connections (black/ orange) corresponds to the color of the fiber optics for the polymer fiber cable, which are specified under "Fiber Optic Interface" on page 10. Connect the individual fiber optic cables between adjacent terminals according to their color (e.g., orange cable to orange connections). +24V (U S) +24V (U M) Figure 3 Key: AGND FE Sµpi3 OPC OUT IN Internal circuit diagram LED INTERBUS protocol chip (bus logic including voltage conditioning) Fiber optic connections 7181A004 Power supply unit with electrical isolation Other symbols used are explained in the IB IL SYS PRO UM E user manual. 7181_en_00 PHOENIX CONTACT 3

Connection Example IBS IL 24 BK-T/U IBS IL 24 RB-LK In terms of topology, the remote bus branch, which is opened at the IBS IL 24 BK-T/U, is located between the bus coupler and the branch terminal (B in Figure 5). BA RD UL US RC D RD RC BK-T/U LD UM LD FO RB-LK 1 2 1 2 1 2 1 2 1 11 1 1 11 1 X1 OUT 2 22 2 2 22 2 Figure 5 Bus coupler/branch terminal topology 3 33 3 3 33 3 X2 IN IN Incoming remote bus 4 44 4 4 44 4 OUT BK B Outgoing remote bus BK-T/U Remote bus branch (internal interface) OUT RBLK Outgoing remote bus RB-LK LB/B Local bus (LB; in the event of subsequent I/O terminals) or Remote bus branch (B; in the event of a subsequent branch terminal) INTERBUS IN INTERBUS OUT BK INTERBUS OUT RB-LK 7181A005 Figure 4 Typical connection of the INTERBUS cables INTERBUS IN INTERBUS OUT BK INTERBUS OUT RB-LK Incoming remote bus Outgoing remote bus BK-T/U Outgoing remote bus RB-LK 7181_en_00 PHOENIX CONTACT 4

Configuration Notes When working on an INTERBUS system, only use one transmission speed (500 kbaud or 2 MBaud). The IBS IL 24 RB-LK branch terminal can only be installed directly after a bus coupler, a control terminal or a branch terminal (e.g., IBS IL 24 RB-LK). Isolated Connection and Disconnection Please note that isolated connection and disconnection in the event of an error is only possible with remote bus branch and local bus interfaces. Isolated connection and disconnection in the event of an error is not possible with an outgoing remote bus interface. This means that no INTERBUS device (terminal with protocol chip) must be present between the preconnected terminal and the relevant branch terminal. Power terminals or segment terminals without protocol chip (e.g., IB IL 24 PWR IN) may be present between the preconnected terminal and the relevant branch terminal. You can use up to 15 branch terminals after the bus couplers and control terminals from the current Phoenix Contact catalog. Observe the restrictions and notes provided in the terminal-specific data sheet for you particular application. Restrictions/Special Features: IBS IL 24 BK-T (discontinued item) Only use one IBS IL 24 RB-LK branch terminal in an Inline station with an IBS IL 24 BK-T. ILC 350 ETH / ILC 370 ETH-IB In terms of topology, the first branch terminal after the Inline Controller opens a remote bus. If additional branch terminals are used after the first branch terminal, these branches topologically are remote bus branches with the branch terminal being the first device in the relevant remote bus branch. Figure 6 Example for isolated connection and disconnection in the event of an error You can parameterize isolated connection and disconnection in the event of an error on all shown bus couplers and branch terminals. Isolated disconnection in the event of an error is performed at the following positions: B (Remote bus branch): Remote bus branch LB (Local bus): Local bus The following happens if the corresponding error occurs: F1: Error in the local bus of an Inline station: The local bus interface is disconnected in isolation at the preconnected branch terminal (parameterized for this purpose) or the preconnected bus coupler (parameterized for this purpose). 7181_en_00 PHOENIX CONTACT 5

Example F1: Error on local bus of station 6: Local bus interface of the branch terminal 6.0 is disconnected. The entire bus continues to run except for the local bus disconnected (6.1, 6.2). F2/F3: Error on a remote bus branch or a remote bus topologically located in a branch: The remote bus branch interface is disconnected in isolation at the preconnected branch terminal (parameterized for this purpose) or the preconnected bus coupler (parameterized for this purpose). Example F2: Error between 5.0 and 6.0 (remote bus branch) or error between 6.0 and 8.0 (remote bus topologically located in a branch): The remote bus branch interface at 5.0 is disconnected in isolation. This disconnects devices 6.x and 8.x. Example F3: Error between 5.0 and 7.0 (remote bus topologically located in a branch): The remote bus branch interface at 4.0 is disconnected in isolation. This disconnects devices 5.0, 6.x, 8.x and 7.x. Programming Data ID code 04 hex (04 dec ) Length code 00 hex Input address area 0 bytes Output address area 0 bytes Parameter channel (PCP) 0 bytes Register length (bus) 0 bytes F4: Error on remote bus: Isolated disconnection of an outgoing remote bus interface is not possible in the event of an error. A bus error causes a bus failure. Example F4: Error between 4.0 and 10.0: Bus error which causes bus failure. 7181_en_00 PHOENIX CONTACT 6

Technical Data General Data Housing dimensions (width x height x depth) Weight Permissible temperature (operation) Permissible temperature (storage/transport) Permissible humidity (operation) 24.4 mm x 120 mm x 71.5 mm 89 g -25 C to +55 C -25 C to +85 C 75% on average, 85% occasionally In the range from - 25 C to+ 55 C appropriate measures against increased humidity (> 85%) must be taken. Permissible humidity (storage/transport) 75% on average, 85% occasionally For a short period, slight condensation may appear on the outside of the housing if, for example, the terminal is brought into a closed room from a vehicle. Permissible air pressure (operation) 80 kpa to 106 kpa (up to 2000 m above sea level) Permissible air pressure (storage/transport) 70 kpa to 106 kpa (up to 3000 m above sea level) Degree of protection IP20 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Interfaces (INTERBUS) Remote Bus Incoming remote bus Outgoing remote bus Through data routing Polymer fiber 980 µm/1000 µm; HCS fiber 200 µm/230 µm Connection using F-SMA connector The IBS IL 24 RB-LK does not count as an Inline station device (63, maximum). Remote bus branch/local bus Recommended cable lengths Local Bus Connection Level Number of Inline terminals that can be connected Limitation through software Limitation through power supply unit Maximum current consumption of the connected local bus modules at the communications power: Maximum current consumption of the connected local bus modules at the analog supply: Through data routing See INTERBUS system data Through data routing 5 V CMOS signal level 63, maximum I max 2 A DC I max 0.5 A Observe current consumption of the terminals Observe the current consumption of each device when configuring an Inline station! It is specified in every terminal-specific data sheet. The current consumption can differ depending on the individual terminal. The permissible number of devices that can be connected therefore depends on the specific station structure. 7181_en_00 PHOENIX CONTACT 7

Transmission Speed IBS IL 24 RB-LK IBSIL24RB-LK-2MBD 500 kbaud 2 MBaud Power Consumption (IBS IL 24 RB-LK) Communications power U L Current consumption from U L Power consumption from U L Analog supply voltage U ANA 24 V DC (nominal value) Nominal current consumption at U ANA 42 ma (nominal value); 51 ma (maximum; at U ANA = 19.2 V) Power consumption from U ANA 1.00 W (nominal value); 1.05 W (maximum; at U ANA = 30.0 V) Power Consumption (IBS IL 24 RB-LK-2MBD) Communications power U L Current consumption from U L Power consumption from U L Analog supply voltage U ANA 24 V DC (nominal value) Nominal current consumption at U ANA 47 ma (nominal value); 57 ma (maximum; at U ANA = 19.2 V) Power consumption from U ANA 1.13 W (nominal value); 1.20 W (maximum; at U ANA = 30.0 V) Supply of the Module Electronics Through the Bus Coupler (U ANA ) Connection method Through potential routing Power Dissipation Formula to Calculate the Power Dissipation of the Electronics P EL = U ANA x I TOT Where P EL Total power dissipation in the terminal U ANA Analog voltage I TOT Total current consumption in the branch terminal at U ANA Example: P EL = 24 V x 42 ma P EL = 1.008 W Power Dissipation of the Housing P HOU P HOU = 1.2 W in the total permissible ambient temperature range Derating Up to an ambient temperature of 55 C Up to an ambient temperature of 50 C For this temperature range, insert at least one Inline terminal that is not an INTERBUS device (e.g., segment/ power terminal without protocol chip) between bus coupler/ controller and the first IBS IL 24 RB-LK. No restrictions Error Messages to the Higher-Level Control or Computer System None 7181_en_00 PHOENIX CONTACT 8

Safety Equipment None Electrical Isolation/Isolation of the Voltage Areas Common Potentials The 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply, and 5 V communications power of the branch terminal share a common potential. Separate Potentials The communications power ground is jumpered to the ground of the 7.5 V communications power for the bus coupler power supply unit. The I/O supply is always electrically isolated from the interface supplies. Electrical Isolation/Isolation of the Voltage Areas When Combining a Bus Coupler and the IBS IL 24 RB-LK Branch Terminal Test Distance Test Voltage 5 V supply of incoming remote bus (bus coupler) electrically isolated from 5 V supply of outgoing remote bus (bus coupler) 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply, 5 V communications power of branch terminal 24 V main supply, 24 V segment supply Functional earth ground 5 V supply of outgoing remote bus (bus coupler) electrically isolated from 5 V supply of incoming remote bus (bus coupler) 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply, 5 V communications power of branch terminal 24 V main supply, 24 V segment supply Functional earth ground 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply, 5 V communications power of branch terminal electrically isolated from 5 V supply of incoming remote bus (bus coupler) 5 V supply of outgoing remote bus (bus coupler) 24 V main supply, 24 V segment supply Functional earth ground 24 V main supply, 24 V segment supply electrically isolated from 5 V supply of incoming remote bus (bus coupler) 5 V supply of outgoing remote bus (bus coupler) 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply, 5 V communications power of branch terminal Functional earth ground 7181_en_00 PHOENIX CONTACT 9

Fiber Optic Interface Polymer Fibers HCS Fibers Minimum optical output power at 25 C (control level 15) > 5.3 dbm > 16.0 dbm, typical Maximum optical output power at 25 C (control level 15) 3.0 dbm 9.0 dbm Laser protection class according to 1 1 DIN EN 60825-1:1994 + A11:1996 Minimum optical power at 25 C after module power up > -6.8 dbm > 17.5 dbm, typical (control level 14) Optical output power (-25 C to 55 C) (control level 15) > 6.2 dbm > 16.9 dbm, typical Minimum optical receiver responsivity < 21.6 dbm < 23.0 dbm (-25 C to 55 C) Optical overrange at 25 C > 2.0 dbm > 4.0 dbm Available attenuation (-25 C to 55 C) > 15.4 db > 6.1 db Maximum wavelength (-25 C to 55 C) 660 nm 660 nm System reserve 3 db 3 db Available attenuation for optical fibers (-25 C to 55 C) > 12.4 db > 3.1 db Cable type PSM-LWL- PSM-LWL- PSM-LWL-HCS RUGGED; PSM-LWL- KDHEAVY RUGGED-FLEX Maximum attenuation at 660 nm LED measurement 230 db/km 280 db/km 10 db/km Typical attenuation at 660 nm LED measurement 200 db/km 250 db/km 8 db/km Guaranteed maximum transmission distance 50 m 35 m > 100 m (300 m, typical) 7181_en_00 PHOENIX CONTACT 10

Ordering Data Terminals Description Order Designation Order No. Pcs./Pkt. Inline branch terminal for an INTERBUS remote bus; IBS IL 24 RB-LK 28 78 11 7 1 connections using fiber optics; transmission speed: 500 kbaud Inline branch terminal for an INTERBUS remote bus; connections using fiber optics; transmission speed: 2 MBaud IBSIL24RB-LK-2MBD 28 78 15 9 1 Accessories Description Order Designation Order No. Pcs./Pkt. Four F-SMA connectors are required for connecting INTERBUS. F-SMA connector set for polymer fibers, for self-assembly, consisting of four quick mountable connectors with bending protection F-SMA connector set for HCS fibers, for self-assembly, consisting of four quick mountable connectors with bending protection PSM-SET-FSMA/4-KT 27 99 72 0 1 PSM-SET-FSMA/4-HCS 27 99 48 7 1 Ordering data for fiber optic cables and additional accessories for assembling fiber optic cables can be found in the "INTERFACE" catalog. Documentation Description Order Designation Order No. "Configuring and Installing the INTERBUS Inline Product IB IL SYS PRO UM E 27 43 04 8 Range" user manual Fiber Optic Installation Guidelines DB GB IBS SYS FOC ASSEMBLY 94 23 43 9 PHOENIX CONTACT 08/2005 7181_en_00 PHOENIX CONTACT 11