Modular Block Converter Systems

Similar documents
S-Band Redundant LNA Systems

Cisco Prisma II Platform

Ku-Band Solid-State Power Amplifier

Prisma II Platform. Optoelectronics

Compact Redundancy Switch 2:1 RSCC-2

Compact Redundancy Switch 2:1 RSCC-2

C-Band Solid-State Power Amplifiers

Redundancy Switch Controller 1:1 RSCM1

Instruction Manual Model Block Translator

1:1 C-Band LNA Redundancy System

Series 8000 RF Signal Switch Solution

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Series 8000 RF Signal Switch Solution

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

NI PXIe-1062Q Power Supply Shuttle

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

LASER PLUS OPERATING INSTRUCTIONS

Each amplifier can be remote controlled via the standard IEEE-488 GPIB.

ELECTROMECHANICAL SWITCH MATRICES

TABLE OF CONTENTS 1. OVERVIEW... 1

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION

464kA. 256x256 SOLID STATE SWITCH SYSTEMS. 464kA SALIENT FEATURES SYSTEM OPERATION. 464kA DESCRIPTION

464kC SOLID STATE SWITCH SYSTEMS. 464kc SALIENT FEATURES SYSTEM OPERATION. 464kC DESCRIPTION

Cisco MCS 7845-H1 Unified CallManager Appliance

CPCI System Subrack 3 U

Summit Virtual Chassis Design and Installation Guide

4164 Switch Matrix System Description

A0750 AC-DC POWER MODULE

FS2000 Series Fast Switching Synthesizer

CPCI System Subrack 1 U

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

3+1 U CPCI Serial System

Installing the IPS 4345 and IPS 4360

CMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS

CSPS-6K (Shelf Type) POWER you need POWER SHELF

VME64x System Subrack 8 U

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Installation Job Aid for VSP 4450GTX-HT- PWR+

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

IFL MICROWAVE PHOTONICS LINKS TO 30 GHZ

DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

RT12-240V/2.4kW Rectifier Specification

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

VME64x System Subrack 1 U

DISTRIBUTION AMPLIFIER SYSTEMS

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS

Specification Sheet S2561E-001 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 1024x1024 System S2561E

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

1.2 Intel Server Chassis SC5400BASE Summary

Cisco MCS 7825-I1 Unified CallManager Appliance

RADCOM s Platform Specifications. Valid from Version 7.10

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

1073N. Channel Amplifier. User Manual Issue 1.3

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Cisco D9036 Modular Encoding Platform

CT-400 FEATURES. A Price/Performance Breakthrough for VXI Mainframes. Modular Power Supply Assembly. Over 1100 Watts of Usable Power

Chassis-based Media Converters

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

Tracewell S42 for VXS/V64x

Optimux-34 Fiber Optic Multiplexer

6220 Ethernet-Based Voltage Measurement Module

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER

Chapter 2 BladeStation Enclosure

RF0250 RF1100 RF1200 RF1300 RF1600

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Installing and Configuring Rialto Analytic Appliances

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

QUALITROL QTMS Transformer Monitoring System

Installation Job Aid for Ethernet Routing Switch 5900 Series

3/4 U CPCI Serial Case System

Installation Job Aid for VSP 4850GTS

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

NVE40K Installation Guide

Junos WebApp Secure 5.0 Hardware Guide

Power Enclosure Components

User Guide Ku Band Solid State Amplifiers - SSPA

SWITCH SOLUTIONS SWITCH MATRIX CATALOG ELECTROMECHANICAL MATRIX SOLID STATE MATRIX FIBER OPTIC MATRIX FULLY INTEGRATED SYSTEMS

RT4F-110V/25A RECTIFIER

Brochure. ION Multi-Service Integration Platform. Integrate. Optimize. Navigate. Transition Networks Brochure.

SINGLEstream Link Aggregation Tap (SS-100)

In-Series and Between-Series Adapters SMA

RF switch network. RFB 2000, RFC 2010 or 2020

Premium Online Series

ECHO AIO TEST INTERFACE

AMU1-CHD+MK2 AUDIO MONITORING UNIT

Transcription:

SATCOM Technologies Modular Block Converter Systems C-Band Hot-swappable, plug-in upconverter and downconverter modules Dual, redundant, hot-swappable power supplies Excellent frequency stability over temperature Built-in monitoring of individual modules and overall system performance ternal/external auto-switch 5 or 10 MHz reference Overview The General Dynamics SATCOM Technologies Modular Block Converter (MBC) System eliminates downtime and maximizes performance and ease of repair by providing fully modular systems for up conversion or down conversion. Leveraging patented technology and field-proven architecture, all of the critical system components are hot-swappable without the removal of power and can be removed from the front of the chassis with the exception of the fan assembly which is accessible from the rear panel. Hot-Swappable Architecture The converters can be configured for single-thread operation or for 1:1 or 1:2 redundancy. a redundant system, a backup converter can be switched in automatically or manually to replace a faulted unit; the faulted module may be removed and replaced while the others remain operational. The system design leverages a blindmate backplane for front panel removal for converters, power supplies, logic card, and color touchscreen. The design enables fast and easy repair with continuous operation, achieving MTTR of less than 3 minutes. Features nfront hot-swappable plug-in modules (RF, PS, touch screen, and logic card) navailable in stand-alone, 1:1 redundancy, and 1:2 redundancy configurations ncolor touch-screen user interface ntcp/ip embedded page to monitor and control system functions, and send email alerts nethernet or Serial I/O M&C interface nstandard 19 rack panel, 3.5 high (2 RU), with 22 chassis slides; chassis is 24 deep Preliminary

User terface Leading Edge Software The MBC is equipped with a color touch-screen for local control along with a leading-edge TCP/IP embedded Web Page software package. The software can be configured for remote monitoring, while allowing virtual factory access to monitor the converter modules key performance parameters such as temperature, current, and voltage. The user interface features secure login with user privilege level controls. nconverter modules feature an autoselection reference that automatically phase locks to an external 5 or 10 MHz reference when present, or uses its internal high stability reference when the external reference is not detected. nbuilt-in RF module monitoring & control capabilities: ngain Adjust or attenuation control nexternal Reference Level nexternal Reference Frequency nreference Phase Lock nlo Phase Lock nmodule Current nmodule -On Self-Test nmodule Temperature RF Module Bands nconverters put LO Frequency put Model 3.40-4.20 GHz 5.15 GHz nconverters 950-1750 MHz (inverted) DCDX put LO Frequency put Model 950-1825 MHz 4.9 GHz 5.85-6.725 GHz UCBX Operating Functions nmonitors and controls two or three redundant RF modules of a single type in either a 1:1 (two module) or 1:2 (three module) configuration. nmonitors and controls one or two independent, single-thread modules. nmonitors the internal power supply modules for faults. nfront panel controls and status indicators nethernet terface: nsnmpv1/2/3 nhttp (Web page) nfirmware dates via secure protocol nrs-232/485/422 Serial terface nredundant Control Modes: nauto Mode: A faulted RF module is automatically switched off line and replaced with the backup unit. nmanual Mode: Allows manual control over which unit is online, via the front panel, serial port, or network. Auto-recovery and Sparing nthe MBC senses loss-of-lock conditions and component failures to initiate switching to a redundant converter. Users have the capability of setting up alert emails, along with remote monitoring capability via embedded TCP/IP web status pages. Replacement of any component can be accomplished within minutes. nsparing of the MBC is dependent upon the user. nactive components nconverter nlogic Board n Supply ntouchscreen nfan Assembly Cooling Fans n The MBC has two cooling fans mounted on an easy-to-replace fan assembly.

Modular Block Converter Systems MBC System Block Diagrams n1-for-1 (1:1) Redundant converter System n1-for-2 (1:2) Redundant converter System Supply #1 Supply #1 Supply #2 Passive Splitter 10 MHz Ext Ref Supply #2 Passive Splitter 10 MHz Ext Ref Pol #1 Converter #1 Converter #2 Blindmate Backplane Online Online Offline Converter #1 Converter #3 Converter #2 Blindmate Backplane Pol #1 Offline Offline Pol #2 Touch Screen Local Control Offline Touch Screen Local Control Pol #2 Main Logic Board = Front panel access for ease of replacement Switch Assembly Main Logic Board Switch Assembly = Front panel access for ease of replacement n1-for-1 (1:1) Redundant converter System n1-for-2 (1:2) Redundant converter System Supply #1 Supply #2 Passive Splitter 10 MHz Ext Ref Supply #1 Supply #2 Passive Splitter 10 MHz Ext Ref Pol #1 Converter #1 Converter #2 Touch Screen Local Control Blindmate Backplane Online Online Offline Offline Converter #1 Converter #3 Converter #2 Touch Screen Local Control Blindmate Backplane Pol #1 Offline Offline Pol #2 Pol #2 Main Logic Board = Front panel access for ease of replacement Switch Assembly Main Logic Board Switch Assembly = Front panel access for ease of replacement

converter Module Performance Parameter Notes Min. Nom./Typ. Max. Units RF put At maximum gain -10 m RF put VSWR IF put VSWR Ratio Return Loss 19.1 Ratio Return Loss 14 1.25 :1 1.5 :1 LO Leakage -50 m Reference put Frequency Auto Detect 5 or 10 MHz Reference put At module -7.5 0 +7.5 m put at 1 Compression (P 1 ) IF put, at max. gain +15 +17 m 3rd Order tercept Point IF put, at max. gain +26 +28 m Gain At max. gain setting 24 26 30 Gain Step Resolution 0.5 Adjustable Gain Range 25 Gain Flatness Gain Stability -Band Spurious Full band, at max. gain Per 40 MHz, at max. gain Over temperature Per week, constant temp. Per week and over temp. Signal-related Non-signal-related Harmonics At IF -55-45 c Noise Figure At maximum gain 15 16 Temperature Range Voltage Operating Storage ± 1.0 ± 0.5 ± 1.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. Reference Performance 0-40 Parameter Notes Min. Nom./Typ. Max. Units ternal Reference Standard Aging per day Aging after 10 years External Reference Requirements Frequency Frequency Tolerance Level Impedance Ref PLL Bandwidth Ext. Ref. Phase Noise Req. 12 20 0 to +50 C ±30 ±1 ±500 All subbands At module 10 Hz Offset 100 Hz Offset 1 khz Offset 10 khz Offset -10 5 or 10 ±0.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. 50 ± 1 ± 0.25-60 -70 +50 +85 0 10-105 -135-145 -150 c m Vdc W C C MHz ppm m ohms Hz m/hz m/hz m/hz m/hz

Modular Block Converter Systems converter Module Performance Parameter Notes Min. Nom./Typ. Max. Units IF put -7 m IF put VSWR RF put VSWR Ratio Return Loss 14 Ratio Return Loss 19.1 1.5 :1 1.25 :1 LO Leakage -50 m Reference put Frequency Auto Detect 5 or 10 MHz Reference put At module -7.5 0 +7.5 m put at 1 Compression (P 1 ) RF put, at max. gain +15 +17 m 3rd Order tercept Point RF put, at max. gain +26 +27 m Gain At max. gain setting 24 26 30 Gain Step Resolution 0.5 Adjustable Gain Range 25 Gain Flatness Gain Stability -Band Spurious Full band, at max. gain Per 40 MHz, at max. gain Over temperature Per week, constant temp. Per week and over temp. Signal-related Non-signal-related Noise Figure At maximum gain 15 16 Temperature Range Voltage Operating Storage ± 1.0 ± 0.5 ± 1.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. 0-40 12 20 ± 1 ± 0.25-60 -70 +50 +85 c m Vdc W C C Reference Performance Parameter Notes Min. Nom./Typ. Max. Units ternal Reference Standard Aging per day Aging after 10 years External Reference Requirements Frequency Frequency Tolerance Level Impedance Ref PLL Bandwidth Ext. Ref. Phase Noise Req. 0 to +50 C ±30 ±1 ±500 All subbands At module 10 Hz Offset 100 Hz Offset 1 khz Offset 10 khz Offset -10 5 or 10 ±0.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. 50 0 10-105 -135-145 -150 MHz ppm m ohms Hz m/hz m/hz m/hz m/hz

Phase Noise Performance Maximum c/hz at converter converter 10 Hz Offset -36-36 100 Hz Offset -66-66 1 khz Offset -76-76 10 khz Offset -86-86 100 khz Offset -96-96 1 MHz Offset -106-106 System Performance The redundant modular block downconverter or upconverter system generally has the same performance as the individual converter modules with the following exceptions: Parameter RF port VSWR IF port VSWR System RF Losses (typ.) System IF Losses (typ.) Gain Flatness (typ.) Noise Figure Reference put Specification 1.3:1 max. (17.7 RL) 1.9:1 max. (10.1 RL) 2 1 Add ±0.3 to module specification Add +2 to module specification -5 to +5 m; 0 m typical Supply Parameter Specification AC put (dual line input) 90 264 Vac, 47 63 Hz; 60 W typical DC put 12 V, 250 W over 0 to +50 C Connector terfaces Parameter Specification RF/IF put Type N, 50 ohms (standard); SMA, 50 ohms (option) IF/RF put Type N, 50 ohms (standard); SMA, 50 ohms (option) 10 MHz External Reference put BNC Female Network RJ-45/CAT 5 Ethernet Serial I/O DB-9 (RS-232, RS-422, RS-485:2, RS-485:4)

J4 J5 J6 WARNING Hazardous moving parts Keep away from moving fan blades J1 J2 J3 J7 Modular Block Converter Systems line Drawing 26.26 [667] 0.65 [16] 23.87 [606] AC 2 AC 1 AC INPUT: 90-264 Vac, 47-63 Hz IEC 60320-1:C14 FACTORY USE ONLY - 100-135/180-240V; 6.0/3.0A; 50/60 Hz - Fusing - 100-135V: 250V 6.3A SLO-BLO 180-240V: 250V 3.15A SLO-BLO - Consult O&M manual for installation instructions. - Refer servicing to qualified personnel. USB - FIRMWARE UPGRADE PORT NETWORK CAN SERIAL I/O SERIAL I/O - DB9 GND TERMINAL - #8-32 HARDWARE PROVIDED WIRE SIZE: 18-22 GA NETWORK - CAT 5 ETHERNET REMOVE DISPLAY TO ACCESS POWER SUPPLY MODULES REAR PANEL AIR EXHAUST POINTS DANGER RISK OF ELECTRIC SHOCK. Disconnect all sources of supply prior to servicing. 19.0 [483] 18.13 [461] STATUS ONLINE MODULE 2 J1-6 TYPE N (F) - 50 OHM SEE CHART STATUS ONLINE MODULE 3 (OFFLINE) SEE NOTE 2 - CONNECTOR OPTION STATUS ONLINE MODULE 1 10 MHz EXTERNAL REFERENCE INPUT BNC (F) - 50 OHM MBC-2XXXX-X BLOCK CONVERTER RF: XX.XX-XX.XX GHz LO: XX.XX GHz IF> XXX-XXXX MHz IF/RF CONNECTORS: DESIGNATOR FUNCTION J1 POL 1 IN J2 OFFLINE IN J3 POL 2 IN DESIGNATOR FUNCTION J4 POL 1 OUT J5 OFFLINE OUT J6 POL 2 OUT NOMINAL LENGTH 22 [559] EXTENDED LENGTH 44 [1118] MAX. 0.43 [11] 1.75 [44] 0.86 [22] 3.47 [88] NOTES: 1. DIMENSIONS ARE IN INCHES [MM]. 2. SMA CONNECTOR (50 OHM) OPTION AVAILABLE. 3. CHASSIS WEIGHT, INCLUDING SLIDES (WITH NO RF MODULES INSTALLED) IS APPROXIMATELY 21.8 lb (9.9 kg). CHASSIS WEIGHT WITH 3 RF MODULES INSTALLED IS APPROXIMATELY 32.4 lb (14.7 kg). 4. MATING CONNECTORS INCLUDED BUT NOT SHOWN. AIR INTAKE POINTS ALONG FRONT PANEL Part Number/Ordering formation Top-Level Configuration cludes rack chassis with 2 power supply modules and choice of 1 (single-thread), 2 (1:1 redundant), or 3 (1:2 redundant) RF modules: Configuration Single-thread, no redundancy (1 RF module)...x 1:1 Redundant (2 identical RF modules)...1 1:2 Redundant (3 identical RF modules)...2 Module Identifier (see below)...xxxx Rear Panel RF connectors Type N, 50 ohms (Standard)...X SMA, 50 ohms (Option)...1 - Note: Standard configuration includes only one type of RF module per chassis. RF Modules... To order single modules separately: MBC- BCM- converters C-Band 3.4-4.2 GHz in, 5.15 GHz LO, 950-1750 MHz out... DCDX (inverted spectrum) converters C-Band 950-1825 MHz in, 4.9 GHz LO, 5.85-6.725 GHz out... UCBX Note: To order a blank module cover plate, use part number MPAN-30281. PS modules can also be ordered separately, part number AMAX-30271-1. Spares Kit cludes 1 Fan Assembly, 1 Supply Module, 1 Logic Module, and 1 Display Module. Converter modules sold separately.

SATCOM Technologies customercare@gd-ms.com www.gdsatcom.com Phone: +1-770-689-2040 2017 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes in its products and specifications at anytime and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners. Reg. U.S. Pat. and Tm. Off. 31339 Rev. - Preliminary