Data Center SC1. Santa Clara, CA

Similar documents
Data Center NJ1. Piscataway, NJ

PISCATAWAY, NEW JERSEY NJ1 DATA CENTERS POWERED BY TRUST

KEEPING YOU OUT IN FRONT

2055 E TECHNOLOGY CIRCLE

1200 West 7th Street, Los Angeles, CA Smart.

CenturyLink Data Center Services Omaha, Nebraska

AT&T Enterprise Hosting Services

EXPERIS DATA CENTER Valley Pike, Middletown, VA. Location Map & Aerials. Building Profile & Facts. Floor Plans

CenturyLink Data Center Services Herndon, Virginia

Kifer Industrial Park

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

1301 FANNIN HOUSTON, TEXAS 77002

POWERING A CONNECTED ASIA. Pacnet Hong Kong DataSpace1 Technical Specifications. Advanced Data Center Facility for Multi-Site Enterprises

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

MD-ALPHA DATA CENTER. Hagerstown, Maryland

PEARL MANHATTAN, NY

ASCENT DATA CENTER. 30 MW Data Center Enterprise Grade Facility LEED Gold ATLANTA, GA ABOUT ASCENT CO LO CAT I O N SUI T E S AVAI LAB LE NO W!

DATA CENTER COLOCATION BUILD VS. BUY

THE TELEPORT. Merrill Lynch Data Center. TELEHOUSE Center. Teleport I Teleport II AT&T / Globecast. Ariel view of the Teleport

Integrated Systems in High Reliability Applications. John H. Hatcher, M.B.A., P.E., C.P.P., LEED President, HMA Consulting

Tier IV Standards as Specified in the TIA 942 Document

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

GROW YOUR BRAND AND MAKE AN IMPRESSION. Unique 2-storey office building with Highway 401 exposure

The Region s Leading Data Center Developer, Manager and Operator

RECENTLY RENOVATED OFFICE / DATA CENTER

Delaware s Premier Suburban Office Park

Delaware s Premier Suburban Office Park

DATA MSP RD AVE S MINNEAPOLIS, MN MINNEAPOLIS, MINNESOTA

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

TURN-KEY AND BUILD-TO-SUIT WHOLESALE DATA CENTER SOLUTIONS

CARRIER NEUTRAL, PROVIDING ACCESS TO A RICH CONNECTIVITY AND CLOUD ECOSYSTEM

8505 Baycenter Road Jacksonville, FL

Data Center. Tai Po Data Center

Dude Solutions Business Continuity Overview

THE DATA CENTRE EVOLVED. Montreal s only true stand-alone, purpose-built data centre NEXT GENERATION DATA CENTRE. 544 rue de l Inspecteur, Montreal

Dazelidis Thanos - Product Manager Rittal Greece 1

An Adaptive Data Center for Dynamic IT Aligned Energy s Dallas-Plano Data Center

AHEAD IN THE CLOUD. A business park for the digital age URBACON DATA CENTRE SOLUTIONS. Barker Business Park Digital Campus Richmond Hill, ON

World Class. Globally Certified. High Availability.

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

STREAM PRIVATE DATA CENTER HOUSTON MARKET THE WOODLANDS Ross Avenue, Suite 2800 Dallas, Texas

MSYS 4480 AC Systems Winter 2015

8505 Baycenter Road Jacksonville, FL

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

PRODUCTS & SERVICES. colocation services

Twin Core Data Center Munich

Building 8: Office & Lab Space

MINNEAPOLIS MARKET STREAM PRIVATE DATA CENTER CHASKA, MINNESOTA Ross Avenue, Suite 2800 Dallas, Texas 75201

intr ducing Sydney East GLOBAL SWITCH

RAPID CITY CALL CENTER 1400 TURBINE DRIVE RAPID CITY, SD FOR SALE / FOR LEASE OFFICE / CALL CENTER 133,102 SQ. FT.

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Vantage 70 Frederick s Most Visible Location

Washington Square FPO. 111 Washington Square > Office Space FOR LEASE > OFFICE SPACE 111 WASHINGTON AVENUE, MINNEAPOLIS, MN 55401

University of Florida Data Center at Eastside Campus: Key Facts

The Shared Data Centre Project

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Data Center Facility Analysis Project. Final Presentation Wednesday, July 22, :30 3:30 PM

98,000 sq. ft. Crescent Building For Sale. Sale Price: $5,500,000. Jim Koon, Managing Broker (208) or (208)

Datacentre Reading East 2 Data sheet

1605 Lakes Parkway. Lawrenceville, Georgia Gwinnett County. 100,000 SF (Expandable) 17.7 Acres

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

HPC Solutions in High Density Data Centers

5.2 MW, Pod-based build, Chilled Water, ft 2

LEADERS IN MEP, COMMISSIONING & ICT FOR BOSTON AND THE NORTHEAST

November/December 2011

FPX. Forest Park Ten 8333 Forest Point Boulevard Charlotte, NC Cardinal Real Estate Partners LLC

FOR SALE OR LEASE CORPORATE RIDGE I FORMER INTEL FAB 23 BUILDING 1615 GARDEN OF THE GODS ROAD COLORADO SPRINGS, CO The Flexible Fab Building

High Performance Computing (HPC) Data Center Proposal

FAIRFIELD COUNTY S PREMIER TECHNOLOGY CENTER River Bend 2

WHITE PAPER. Solutions OnDemand Hosting Overview

COPT DC-6. Security & Reliability Redefined Hornbaker Road Manassas, Virginia » UP TO 5MW AVAILABLE

Data Center and Colocation RFP Template

FOR SALE OR LEASE CORPORATE RIDGE I FORMER INTEL FAB 23 BUILDING 1615 GARDEN OF THE GODS ROAD COLORADO SPRINGS, CO The Flexible Fab Building

210,000 rsf Typical floorplate 67,549 rsf

Introduction. Service and Support

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

AVANTAGE DATA CENTER. The only ecological «green» data center in Russia with application of the best innovative technologies

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

DATACENTER COLOCATION. Flexible, Secure and Connected

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Data Center Energy Savings By the numbers

About Infomart Data Centers

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

DUB4. An innovative data centre. Resilience. Power. Flexibility AT NORTHWEST BUSINESS PARK

Office/R&D Space for Sublease 1955 Concourse Drive, San Jose

DATACENTER CAMPUS FRANKFURT. Plan for Every Second

Datacentre Newbridge Data sheet

DATACENTER BERLIN Definitely a Good Perspective

Case Study: Two New High-Rise Buildings ABN AMRO Plaza, Chicago, IL

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Datacentre Milton Keynes Data sheet

Fact sheet VIENNA DATA CENTRE CAMPUS. Connect, transact and grow

41965 ECORSE ROAD VAN BUREN TOWNSHIP, MICHIGAN

N O W A V A I L A B L E

Planning a Green Datacenter

Impact of Air Containment Systems

1008 kw, Tier 2, Chilled Water, ft 2

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Transcription:

Data Center SC1 Santa Clara, CA

powerful/ efficient /reliable solutions >

Data Center SC1 ABOUT DUPONT FABROS TECHOLOGY (DFT) DFT is a leading owner, developer, operator and manager of wholesale data centers. Our highly advanced and secure facilities power, cool, and protect the computer servers of numerous enterprise and technology companies. In conjunction with our operational expertise, we deliver uninterrupted service and ultimate reliability to our customers mission critical business applications. OVERVIEW One of the largest, most sophisticated and efficient data centers available in the Greater San Francisco Bay area, SC1 will bring a new class of data center to the market. Designed to LEED Standards, SC1 will be built in two identical Phases, each comprising 18.2 MW of Critical Load. With its flexible and efficient design, customers are able to lease one or multiple dedicated computer rooms each with independent redundancy and security. Should a tenant s requirement increase, our scalable solution enables them to take additional space as needed. The facility has multiple major fiber carriers on site and will benefit from the area s most competitive power rates. PHILOSOPHY Committed to ultimate reliability, DFT s philosophy is to design, build, operate and manage highly dependable and environmentally efficient data centers. Our goal is to maximize Power Usage Effectiveness ("PUE") in all aspects of data center operations. Dynamic electrical distribution and flexible floor plans provide optimal solutions for our tenants. DFT commissions proven technologies, such as rotary UPS and evaporative chilled water systems, in configurations that maximize utilization of the data center design and infrastructure. Our engineering track record and expertise enable us to shorten the duration of construction and minimize costs which directly benefit our clients. >

Data Center SC1: Specifications Location: Santa Clara, CA Acreage: 16 Building Size: 360,000 sq ft Nearest Airport: San Jose International Airport PROPERTY BUILDING DESCRIPTION ROOM SPECIFICATIONS DATA CENTER AREA DESCRIPTION STAGING/TENANT OFFICE SPACE SECURITY CRITICAL POWER UPS SYSTEMS GENERATORS ON SITE FUEL CAPACITY HEAT REJECTION SYSTEMS (HVAC) PDUS COMMUNICATIONS Utility Power: 26.4 kv Parking: 182 Number of Stories: 1 plus Mezzanine Loading Docks: 4 Dock Bays Rooms 1-6, 11-16: Critical Load: 2.275 MW Approx. Gross SF: 11,000 Rooms 7A-10D: Critical Load: 0.56875 MW Approx. Gross SF: 2,700 Raised Floor Area: 176,200 sq ft Raised Floor Height: 42 under raised floor plenums Raised Floor to Ceiling Height: 15-22 ft Office: 12 private suites Staging: multiple staging rooms Building: Ballistic glass enclosed security check-in, front window areas and loading dock. Security Guards: Staffed 24/7 Access Control: Electronic security features with card key access and dual authentication with biometric readers CCTV: 24/7 surveillance of the interior/exterior of the facility Total Megawatts: 36.4 Description: 32 Rotary power systems with 1,300 kw of critical output each Redundancy: N+2, Each Phase Description: 32 diesel-powered engine generators with 2,250 kw capacity each Redundancy: N+2, Each Phase Storage Tanks: Four 50,000 gallon underground diesel storage tanks Number of Hours: Nominal 55 Hours Description: 16 centrifugal chillers with 1,080 Ton capacity each Redundancy: N+2, Each Phase Storage Tanks: Two 500,000 gallon above ground chilled water storage tanks Description: Dual Input 300 kva PDUs - 600 volt primary POE: 4 separate network Points of Entry (POE) with diverse underground duct banks providing multiple entry points into the facility Conduits: Dedicated underground conduits to each computer room Multiple Carriers: Available Meet-Me-Room: Available Description: Conventional smoke detector and laser based incipient smoke detection systems and double interlocked pre-action sprinkler system FIRE PROTECTION >

Data Center SC1: Map CENTRIFUGAL CHILLER (TYP.) CENTRIFUGAL CHILLER (TYP.) CORRIDOR 4 ROOMS 1-6 28 TON CRAH (TYP.) MECHANICAL ROOM 1 MECHANICAL ROOM 2 BLR. RM. 1 CORRIDOR 3 BLR. RM. 2 CORRIDOR 8 ROOMS 11-16 CORRIDOR 9 ROOMS CORRIDOR 6 CORRIDOR 7 ROOMS 1 2 3 4 5 6 11 12 13 14 15 16 7B 7D 8B 8D 9B 9D 10B 10D CORRIDOR 5 MV. 1 UPS 1-8 UPS 9-16 POE 1 7A POE 4 CORRIDOR 2 7C 8A 8C 9A 9C 10A 10C CORRIDOR 2 POE 2 NOC/FAC. ELEV. CNTRL. RM. POE 3 MR. TC. MEET RM. 1 9 10 2 3 4 5 6 7 8 W. OFF. 11 12 13 14 15 16 SPK. SHOP/STORAGE FACILITIES STG. 4 STG. 3 CORRIDOR 1 M. STG. 2 DOCK STG. 1 LOB. CON. STG. 5 SEC. CON. OFF SWITCHBOARD (TYP.) SWITCHBOARD (TYP.) EG 1-8 DIESEL ENGINE GENERATOR (TYP.) STOR. MER. RM. MECH. RM. MECH. RM. STOR. DIESEL ENGINE GENERATOR (TYP.) EG 9-16 1 2 3 4 5 6 7 8 ELEV. CR. PRTS. 9 10 11 12 13 14 15 16 LOU. OFF. 201 OFF. 212 OFF. 213 TE/EL OFF. 203 OFF. 209 OFF. 211 W. STOR. MEZZANINE FLOOR M. OFF. 204 OFF. 208 OFF. 210 OFF. 205 OFF. 206 OFF. 207 BR. RM. SPACE ALLOCATIONS PHASE 1 PHASE 2 Electrical/Mechanical Computer Room Public Circulation Data/Telco Support Administration/Office MV. 2 T. S. T.

For more information please contact leasing@dft.com 1212 New York Ave., NW Suite 900 Washington, DC 20005 P 202.728.0044 F 202.728.0220 www.dft.com NYSE: DFT