How to Change Firmware in WT1000 Terminals. A Technote by Systems Engineering

Similar documents
Tisio CE Release Notes

NCD ThinPATH PC Installation Guide and Release Notes

NCD ThinSTAR User s Guide

Upgrading MYOB BankLink Notes (desktop)

SonicWALL CDP 2.1 Agent Tool User's Guide

WTOS FTP/HTTP/HTTPS/CCM UPGRADE METHODS

EAM Portal User's Guide

AVR42789: Writing to Flash on the New tinyavr Platform Using Assembly

IPNexus Server Secure Instant Messaging & Integrated Collaboration

Xerox Security Bulletin XRX12-011

Native route discovery algorithm

Polycom Updater Release Notes Applies to SoundStation IP 6000 and IP 7000

One Identity Active Roles 7.2

One Identity Quick Connect Express

Trimble S6 and SPS700 Total Station Firmware

Stellar Phoenix Password Recovery For Windows Server. Version 2.0. User Guide

May 2014 Product Shipping Configuration Change Notice

PCMCIA Flash Card User Guide

FW Update Tool. Installation Guide. Software Version 2.2

One Identity Password Manager User Guide

APPLICATION NOTE. AT03324: Atmel REB212BSMA-EK Quick Start Guide. Atmel MCU Wireless. Introduction

Polycom RealPresence Media Manager

Setting up the DR Series System on Acronis Backup & Recovery v11.5. Technical White Paper

MyCreditChain Terms of Use

Polycom Updater Release Notes

Mile Terms of Use. Effective Date: February, Version 1.1 Feb 2018 [ Mile ] Mileico.com

Dell Statistica. Statistica Enterprise Server Installation Instructions

SafeNet Authentication Client

Dell SonicWALL SonicOS 5.9 Upgrade Guide

APPLICATION NOTE. Atmel AT03160: Migrating Bootloader from ATxmega128A1 to other Atmel XMEGA Devices. Atmel AVR XMEGA. Features.

BIOS Update and Management. Motherboard

x10data Smart Client 7.0 for Windows Mobile Installation Guide

One Identity Starling Two-Factor Authentication. Administrator Guide

Polycom RealPresence Access Director System, Virtual Edition

SUPPORT MATRIX. Comtrade OMi Management Pack for Citrix

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

One Identity Starling Two-Factor HTTP Module 2.1. Administration Guide

One Identity Starling Two-Factor Authentication. Administration Guide

Quest VROOM Quick Setup Guide for Quest Rapid Recovery for Windows and Quest Foglight vapp Installers

AT60142H/HT. Rad-Hard 512Kx8 Very Low Power CMOS SRAM ERRATA-SHEET. Active Errata List. Errata History. Abbreviations. 1.

Trimble R/5000 Series GPS Receivers Release Notes

Setting up the DR Series System with vranger. Technical White Paper

Dell Change Auditor 6.5. Event Reference Guide

Stonesoft Firewall/VPN Express. Release Notes for Version 5.5.4

SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6. Getting Started Guide

CoreBlox Token Translator. Version 1.0. User Guide

This user guide describes how to run the Atmel ATWINC3400 Bluetooth Low Energy (BLE) Provisioning demo from out-of-box conditions.

Atmel LF-RFID Kit Comparison Chart. Application Note. Atmel LF-RFID Kit Comparison Chart. 1. Description

AT-S79 Version ( ) Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

AT-S79 Version Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

Multifactor Authentication Installation and Configuration Guide

Quest VROOM Quick Setup Guide for Quest Rapid Recovery and Foglight Windows Installers

ESS Utility Android App User Guide

One Identity Active Roles Diagnostic Tools 1.2.0

One Identity Active Roles 7.2. Replication: Best Practices and Troubleshooting Guide

One Identity Starling Two-Factor Desktop Login 1.0. Administration Guide

System Administrators Guide

Quest Migration Manager for Exchange Resource Kit User Guide

Metalogix Essentials for Office Creating a Backup

Titan V9 BIOS and Shell Upgrade ECN For all Titan Consoles

SOLUTION GUIDE February A Polycom MSR Series

Quest Enterprise Reporter 2.0 Report Manager USER GUIDE

SonicWall Secure Mobile Access

Quest Migration Manager Upgrade Guide

Paging and Loud Ringing with VVX600 and Algo 8180

WebSphere Integration Kit. Version User Guide

Cisco Unified Communications Self Care Portal User Guide, Release

RELEASE NOTES TRIMBLE REALWORKS SOFTWARE VERSION System requirements New Features and Changes

FontWizardXT 6.7. JoLauterbach Software GmbH. Extended EPS/PDF-Export for QuarkXPress. XTensions Software, Plug-Ins and individual solutions

Quest One Password Manager

Administrator s Guide

Quick Connection Guide

Nokia Horizon Manager Release Notes. Version1.4 SP1

SonicWall Content Filtering Client for Windows and Mac OS

Polycom RealPresence Media Editor

Product Release Information

Polycom Video Border Proxy (VBP ) 7301

Aellius LynX Office Lookup Enhancements

Host Upgrade Utility User Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

One Identity Quick Connect for Base Systems 2.4. Administrator Guide

Migration Tool. Migration Tool (Beta) Technical Note

One Identity Active Roles 7.2. Azure AD and Office 365 Management Administrator Guide

RealPresence Platform Director

SUPPORT MATRIX. HYCU OMi Management Pack for Citrix

Polycom RealPresence Distributed Media Application (DMA ) System

Volume Disaster Recovery Preparation Express Guide

StorageGRID Webscale NAS Bridge Management API Guide

Quest VROOM Quick Setup Guide for Quest Rapid Recovery for Windows and Quest Foglight vapp Installers

By Anthony di Donato. Citrix Systems, Inc.

CALSTRS ONLINE AGREEMENT TERMS AND CONDITIONS

SafeNet Authentication Client

Videoscape Distribution Suite Software Installation Guide

Upgrade Express Guide

USER GUIDE. ZigBit USB Stick User Guide. Introduction

Carbonite Server Backup Portal 8.5. Administration Guide

Introduction to SAP BusinessObjects Dashboards

SQL Optimizer for Oracle Installation Guide

Cloud Access Manager How to Deploy Cloud Access Manager in a Virtual Private Cloud

Application Launcher User Guide

CoreBlox Integration Kit. Version 2.2. User Guide

Transcription:

How to Change Firmware in WT1000 Terminals A Technote by Systems Engineering February 2005

Summary This technote describes how to upgrade the Firmware for Winterm WT1000 terminals. Audience 1st Level Support, Systems Engineering, Customers. Affected Products All 1000 series Winterms. Steps to Perform 1. On the FTP server create a folder called WYSE under the FTP home directory. 2. Under the folder WYSE create a subfolder by the name wnos. Genarally we create the WYSE folder to differentiate between other folders that may reside on the ftp home directory. We create the wnos folder to keep the wnos.ini file as well as the firmware upgrade files. 3. Put the firmware upgrade files in the wnos directory created under WYSE folder in the FTP root directory. This would be TWA_WNOS and TWA_BOOT for 1125, STP_WNOS and STP_BOOT for 1200+, UTC_B512 for 1200. 4. Open the Network Setup Dialogue box by clicking Desktop>System Setup >Network from the Terminal (WYSE thin client). You will get the Dialogue box as shown in the screenshot below. How to Change Firmware in WT1000 Terminals Page 2 of 5

5. In the File Servers/Path field put the address of the FTP Server along with the path (which is wyse that is the folder we created under the FTP root directory). 6. In the username and password field put a valid username and password credentials through which the terminal can access the FTP server. Any user who has read access to the directory will do.if Anonymous user is allowed to logon to the FTP server you can as well use Anonymous logon credentials. 7. Before you can carry on with upgrade or downgrade the firmware you need to put a valid wnos.ini file in the wnos directory. When the terminal boots up it goes to the FTP server and accesses the wnos.ini (configuration file for the thin clients) and in the wnos.ini you can specify whether How to Change Firmware in WT1000 Terminals Page 3 of 5

to disable any upgrade or downgrade or enable upgrade or downgrade or only upgrade the firmware of the terminal. 8. As per the requirement you should include the line in your wnos.ini file as follows : AutoLoad=1 # Selects firmware update mode: 0=disable, 1=upgrade/downgrade, 2=upgrade only 9. Now restart the terminal. 10.The terminal reboots and checks for the new firmware in the wnos directory for an upgrade or downgrade as specified in the wnos.ini file and execute the same. 11. If you are changing both the Flash and Ram image then terminal will reboot twice. Caution has to be maintained as to not to power down the terminal during the process of upgrading or downgrading. 12. After that the terminal will be ready for use with the new Firmware. How to Change Firmware in WT1000 Terminals Page 4 of 5

Limitation of Liability IN NO EVENT SHALL MANUFACTURER, MANUFACTURER'S SUPPLIERS, ANY THIRD- PARTY PRODUCER, OR ANY OTHER PARTY THAT HAS BEEN INVOLVED IN THE CREATION, PRODUCTION, OR DELIVERY OF THE DOCUMENT BE LIABLE FOR ANY DIRECT, CONSEQUENTIAL, INCIDENTAL, INDIRECT, OR SPECIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSSES RESULTING FROM BUSINESS INTERRUPTION OR LOSS OF DATA, REGARDLESS OF THE FORM OF ACTION OR LEGAL THEORY UNDER WHICH THE LIABILITY MAY BE ASSERTED, EVEN IF ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH DAMAGES. THIS DOCUMENT IS PROVIDED "AS IS" WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE. MANUFACTURER DOES NOT WARRANT THAT THE INFORMATION CONTAINED IN THE DOCUMENT OR ANY SOFTWARE REFERRED THEREIN WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION WILL BE UNINTERRUPTED OR ERROR FREE. SOME JURISDICTIONS DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. If you have an technical enquiry please use the online knowledge portal at http://www.wyse.com/serviceandsupport/support/askwyse.asp or contact the numbers mentioned below. Wyse Technology Inc. 3471 North First Street San Jose, CA 95134-1801 International Sales: Australia 61 2 9319 3388 France 33 1 39 44 63 85 Germany 49 89 460099 26 Taiwan 886 3 577 9261 UK 44 118 982 8335 United States 408 473 1200 Wyse Sales: 800 GET WYSE (800 438 9973) Visit our websites at: http://www.wyse.com.au http://www.wyse.fr http://www.wyse.de http://www.wyse.com.tw http://www.wyse.co.uk http://www.wyse.com Or send email to: sales@wyse.com Wyse Customer Service Center: 800 800 WYSE (800 800 9973) 2005 Wyse Technology Inc. All rights reserved. This material is copyrighted. You may not reproduce, transmit, transcribe, store in a retrieval system, or translate into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, any part of this publication without express written permission. Wyse, WY, and WyseWorks are registered trademarks, and the Wyse logo, Winterm logo, Wyse, and Winterm are trademarks of Wyse Technology Inc. ICA is a registered trademark and MetaFrame is a trademark of Citrix Systems Inc. Rapport is a registered trademark of Rapport Technologies, Inc., a division of Wyse Technology Inc. Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Other product names mentioned herein are for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. 09/04 880924-45 Rev. A How to Change Firmware in WT1000 Terminals Page 5 of 5