ClareHAL 104 Electrical Safety Tester

Similar documents
The new ClareHAL Series. Keeping electrical products safe.

The new Clare HAL Series. Keeping electrical products safe. Experts in what we do.

277 Plus Electrical Medical Safety Analyser

Dielectric Withstand and Ground Bond Testers

LOW WEIGHT, SMALL SIZE,

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Features and Benefits

HAL Range of Industrial Electrical Safety Testers. This Operating Manual Covers the HAL 100 HAL 101 HAL 102 HAL 103 HAL 104

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

Solar Installation PV100 Operating Instructions

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

Fully-Automated, Multi-Functional Electrical Safety Compliance Analyzers

Operating Instructions

Operating Instructions

PAT-Cal 2 TECHNICAL MANUAL

Portable Appliance Tester KT75 OPERATORS MANUAL

Experts in what we do. Electrical Safety Test Instrumentation

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Portable Appliance Testing: Choosing the right tester for you

MI 3394 CE MultiTester XA

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Instructions 309A553. August Clare Instruments Issue 2

Solar Installation PV150 Operating Instructions

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

Apollo+ Series. Why buy the new Apollo+ Series? Apollo+ Series Users:

Seaward Supernova Elite

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Seaward Supernova Plus

OPERATING INSTRUCTION

700 Series 200 Amp Clamp Meters

Autoranging True RMS Multimeter User Manual

Clare Safe Check 8. Electrical Safety Tester. Operating Manual. Instructions 309A550. November Clare Instruments Issue 2

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Model A Mini AC/DC Clamp Meter. User's Guide

Wireless TRMS Multimeter and Insulation Tester

Mini Digital Multimeter

User Guide True RMS Multimeter Extech EX205T

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

Seaward Europa Plus. Portable Appliance Tester. Instruction Manual 302A550. December Seaward Electronic Ltd. Issue 2

Clare Safetest Manufacturing (UK / Europe)

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Digital Clamp Meter User Manual

METREL Measuring and Regulation Equipment

Mini Digital Multimeter

HYPOT III. Quick Start Guide

Mini Digital Multimeter Model MN15. User's Guide

PROFITEST 204 For testing the safety of electrical machinery equipment

PRIMETEST PRIMETEST. Operating Instructions

Seaward Supernova. Portable Appliance Tester. Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Earth-fault Relay SPAJ 110 C. Product Guide

ETHOS Auto Ranging Digital Multimeter

Date received into service; / /.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

PrimeTest 250+ PrimeTest 250+ Users Professional PAT Testers Service Engineers Facilities Managers.

Please use the Q & A utility to ask us any questions concerning the material being presented.

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

USER'S MANUAL DCL-650

Top-Innovator Top-Innovator GLP1-g. Safety, function and high-voltage testers. Expect more. Made in Germany. Safety and function testers

Fluke 3000 FC Series Test Tools Technical Data

Wireless TRMS Multimeter and Insulation Tester

MTP INSTRUCTION MANUAL

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Models 6522, 6524, 6526, 6532, 6534 & 6536

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

3156 LEAK CURRENT HiTESTER

HYAMP. Quick Start Guide

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

TRANSMILLE PRODUCT GUIDE 2015/16 PROVIDING SOLUTIONS IN CALIBRATION WORLDWIDE. www. transmille.com

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Sentinel Series Safety Tester. Operating Instructions

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Medical Device Testing Explained

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

Testing Instruments Manufactured by

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

7032 Digital-Analog Multimeter

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

964i High Voltage Switching System

MI 3394 CE MultiTester XA

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Mini Digital Multimeter

User's Guide. Digital Multimeter. Model MN42

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

TELARIS 0701/0702 easy TELARIS 0701/0702

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Transcription:

ClareHAL 104 Electrical Safety Tester Technical Data Sheet Experts in what we do. ClareHAL 104 helps production line test process by: Improving productivity Increasing efficiency Stores results automatically Custom Pass/Fail levels Safety guard operation IEC/EN International Standards compliance Fast testing

ClareHAL 104. A combined AC Ground Bond, AC/DC Flash, DC Insulation Resistance Tester with Power, Load and Leakage capabilities. ClareHAL 104 is designed to offer advanced automation techniques which can make dramatic improvements in productivity and efficiency of the production line manufacturing test process. Key features Function/Power/Load/Leakage/ Touch current test Flash/Hipot/Delectric Strength test COMPLIANCE Standards and Directives Validation testing is essential for manufacturers to ensure compliance with legislation for their products including CE marking. Electrical safety testing specialists Seaward have produced the HAL series that performs all of the applicable tests needed for demonstrating compliance with EU Directives, International, European and UK standards in one convenient package. The ClareHAL 104 will help you meet your legal obligations. All basic tests, as specified in widely used product and safety standards, are included: Earth Bond/ Ground Bond testing DC Insulation Testing AC/DC Flash/ Hipot/Dielectric withstand testing Functional/ Run testing Touch/Leakage Current testing Test Methods using the ClareHAL 104 The ClareHAL 104 Tester can be used in three modes automatic, manual and direct pc control via the external communications port. Automatic Mode In automatic mode complete test sequences are stored in the memory and new sequences can programmed using testcodes. Up to 5 tests can be linked into 1 sequence, all tests are timed and all results are stored in memory. Automatic mode provides a structured, repeatable route to testing which ensures all data is collected for traceability and auditing. This mode is intended for standard production line use. Manual Mode Manual mode provides a quick, simple route to tests and is intended for use in the laboratory, repair or re-test environments where ease of use and quick repeatable tests are are paramount. Manual mode can be initiated by a one button press and allows individual tests to be performed more freely. The type of test and its parameters are entered into the tester. The output can be maintained continuously, varied by means of the rotary encoder or timed as in automatic mode. A facility to store results is available although this is not necessary to perform tests. Ground/Earth Bond test at 40A Fast testing production efficiency savings Compact unit Tests in accordance with IEC/EN/UL International Standards Isolated test outputs on Flash/Hipot/Dielectric Strength/Insulation test to aid with EN 50191 and for safety Arc Detect Regulated outputs on Flash/Hipot/Dielectric Strength, Insulation and Ground/Earth Bond tests independent of supply fluctuations PLC control. Simple command protocol for external control via communications port Visual and audible pass/fail indication cont...

Select the ClareHAL unit which suits your requirements Earth/Ground Bond AC Flash/Hipot DC Flash/Hipot Features 100 101 102 103 104 Key features Operation from 115 and 230 V (nom.), 50 or 60 Hz mains supply. Barcode scanner support DC Insulation Resistance Storage of test results ARC Detection Leakage Large graphical display Load Power Power Factor Selectable 50 or 60 Hz output frequency for AC tests. Results Memory Automation Option Barcode scanner/printer Option Internal scanner External scanner switching matrix for high voltage and high current switching (optional) Safety enclosure (optional) Direct PC Control Simple command protocols are incorporated to enable the product to be controlled directly by a PC or other device connected to the external control port. This level of control is particularly advantageous where the application requires a number of events to occur before test measurements are valid or if a number of measurements need to be taken and synchronized with each event. A typical example requiring this level of control would be the testing of equipment that has several modes of operation, each having the potential to present errors that would not be apparent until the product has reached the applicable state such as a washing machine. PLC Control A PLC can be used to control the ClareHAL unit via the external control ports. PLC control can be initiated with a barcode reader or simulation of the barcode protocol. TESTING - General The unit can perform either continuous or timed tests, except the Earth/ Ground bond test which is timed. If during the Flash test, the arc detect level is exceeded the test will be halted and the output removed. A beeper is present to let the user know that a test fail condition has occurred. The Reset button will clear the condition back to a default screen. If the programmed limit is exceeded at any time during a test, the unit will display the appropriate test fail message. If the test fails the unit will light the red fail indicator, and sound the audible alarm. If hazardous voltages (50V AC or DC) are present on the outputs of the unit, this will be indicated by a red warning indicator and a lightning strike icon will blink on the display. Also the HT present LED indicator will illuminate adjacent to the test output sockets. Auto discharge - at the end of Insulation and Flash testing test all capacitances and inductances will be automatically discharged. The tester would normally be used with a test fixture or guard system and no tests can be performed without positive confirmation that the guard is in place. If the guard is opened or the RESET button is pressed at any time, the test will be halted and an appropriate test fail message will be displayed. Earth/ Ground Bond test The unit generates a constant current output independent of input voltage, which is ramped linearly to the set value. The voltage across and current through the ground

connections of the equipment under test are continuously measured and the impedance calculated and displayed in real-time Test Current the desired test current up to 40A (time limited) Ramp up the time required for the current to be ramped from zero to the desired test current. Ramp hold - the time required for the constant test current to be applied. Ramp down - the time required for the test current to be ramped down to zero amps. Resistance Limit in (mω) Flash/Hipot/Dielectric strength test The voltage generated by this test is isolated at the test outputs for assisting with complying with EN 50191. This test can be timed or continuous. The unit will generate a regulated flash test voltage (independent of the supply voltage), which is ramped linearly to the desired value. The unit will then sample the total leakage current and display it in realtime. The unit will compare the instantaneous measured total leakage against the upper programmed leakage limit to indicate pass or fail. There is a programmable upper and lower limit which ensures that there is a positive indication that the Flash probe has been connected. Test Voltage the desired test voltage. Ramp up the time required for the voltage to be ramped from zero to the desired test voltage. Ramp hold - the time required for the constant voltage to be applied. Ramp down - the time required for the test voltage to be ramped down to zero volts. Total Leakage limit upper (ma) Total Leakage limit lower (ma) Arc detection level All times will be configurable between 0.1 and 300s. The displayed Total Leakage value will be displayed from 0.01 to 10mA (DC) and 0.01 to 20mA (AC). The arc detection level can be programmed between 0 and 10, where 0 disables the function altogether, and 10 provides the least sensitive setting. Insulation Test An insulation resistance measurement at a DC test voltage of 250V, 500V or 1000V is available. This test can be continuous or timed. The selected voltage is ramped linearly to the desired value, where it is then held. The insulation resistance is displayed in real time. If this value is less than the minimum pass value programmed, then the appropriate fail message is displayed along with the red fail indicator Test Voltage which can be pre-selected for 250V, 500V or 1000V Ramp up the time required for the voltage to be ramped from zero to the desired test voltage. Ramp hold - the time required for the constant voltage to be applied. Ramp down - the time required for the test voltage to be ramped down to zero volts. Insulation Resistance value, lower limit (MΩ) Functional/Run/Leakage test An operational test will be conducted at the value of the input supply voltage. The measured power of the unit under test will be displayed in real time. An auxiliary input is provided so that any voltage up to 300VAC can be used in conjunction with the powered test. A simple switch is used to choose between the supply input and Aux input for powered tests. Load Power Min/Max Value (kva) Power Factor Min/Max Value (Ratio) Leakage Current Min/Max Value (ma) Touch Current Min/Max Value (ma) The touch current test will be conducted at the value of the supply and applied via the probe. The measured touch current will be displayed in real time and will use the body model in BS EN 1010 fig A1 Annex A and BS 60990 fig 4.

SPECIFICATIONS: ClareHAL 104, 103, 102, 101, 100 Accessories Power Requirement AC Voltage Selectable 115 or 230 VAC RMS Frequency 50/60 Hz Mechanical Specification Size (HxWxL) 300mm-200mm-370mm Weight 15kg Approx Ground Bond Test 104, 103, 100 Test Voltage Nominal 6V AC Frequency 50 or 60 Hz (Independent of supply) Display Range and Accuracy 0-1500mΩ ±2% ±5 Counts 1 mω Compliance Test Ranges: Current/Load Resistance/Time 5 A-1000mΩ - Continuous 10 A-500mΩ - Continuous 25 A-200 mω - Continuous 30 A-150 mω - 60 secs 40A-100 mω - 60 secs Settable Output Current Range 0.1A-40.0A Selectable Range of Pass/Fail Levels 0-1500mΩ Insulation Resistance Test 104, 103, 102, 101 DC Output Voltage 250V, 500V, or 1000V Selectable Display Range 0.01MΩ-500MΩ Display Range / Accuracy 0.03MΩ-350MΩ ± 5% ± 5 Counts 350MΩ-500MΩ Indication Only 0.01MΩ Pass/Fail Level 0.00MΩ-500.0MΩ Hipot Probe & lead Part number: 03918/2 Hipot Clip (Std. Black) & lead Part number: H-5003 Hipot Clip (Red) & lead Part number: H-5003/R Ground Bond Clip Lead Part number: 01521/1 Hand Held Guard Switch Part number: DCS317 Calibration Checkbox Part number: V242 CCD Barcode Scanner Part number: 194A922 Status Beacon (mains cord 230/110V) Part number: H 5017 Enclosures ENC 6: W300mm x H240mm x D280mm Part Number: 73B239 ENC 7: W600mm x H475mm x D280mm Part Number: 73B240 EN50191 Kit Switching Matrix Part number: 485A910 PowerSmart 1 phase Part number: 483A910 AC Flash / Hipot Test 104, 103, 102, 101 Programmable Voltage Range Frequency Independent of Supply Voltage Display Range and Accuracy Voltage Current Display Range and Accuracy Current Selectable Range of Pass/Fail Levels Maximum Current Output Optional Arc Detection 0.10kV-5.00kV (10V/Step Resolution) 50 or 60 Hz 0.10kV-5.00kV ±1% ± 5 Counts 0.01kV 0.01mA-20.00mA ±1% ± 5 Counts 0.01mA 0.01mA-20.00mA 20.00mA @5kV 9 Levels

DC Flash / Hipot Test 104, 103, 102, 101 Programmable Voltage Range 0.10kV-6.00kV (10V/Step Resolution) Voltage Display Range and Accuracy 0.10 kv-6.00kv ±1% ± 5 Counts Voltage 0.01kV Current Display Range and Accuracy 0.01mA-10.00mA ±1% ± 5 Counts Current 0.01mA Selectable Range of Pass/Fail Levels 0.01mA-10.00mA Maximum Current Output 10.00mA Optional Arc Detection 9 Levels Power and Leakage Test 104 only Power Output Rating Also available ClareHAL 103 AC/DC Hipot (flash dielectric strength) and DC Insulation and Ground/Earth Bond Tester Part No: H103 ClareHAL 102 AC/DC Hipot and DC Insulation Tester with built-in scanner switching matrix Part No: H102 Test Voltage Maximum Power Output 110V 230V AC 20A nominal (Vin-Vout) Up to 5.0kVA (dependant on mains supply rating) ClareHAL 101 AC/DC Hipot and DC Insulation Tester Part No: H101 Output Power Measurement Single Phase Power Measurement Display Range and Accuracy Selectable Range of Pass/Fail Levels 0.02kVA-5.00kVA ±2% ±0.02kVA 0.001kVA-5.000kVA ClareHAL 100 40A Ground/Earth Bond Tester Part No: H100 Single Phase Power Factor Measurement Display Range and Accuracy Ratio 0.000-1.000 ± 0.030 Selectable Range of Pass/Fail Levels 0.000-1.000 Leakage Current Measurement Display Range and Accuracy Selectable Range of Pass/Fail Levels 0.10mA-20.00 ma ± 1% ±5 Counts 0.01mA 0.01mA-20mA Touch Current Measurement Display Range and Accuracy 0.02mA - 5.00 ma ± 1% ±5 Counts 0.01mA Selectable Range of Pass/Fail Levels 0.02mA-5.00mA Measuring Device IEC/EN 60990 Fig 4 (IEC/EN 60990 Fig 3 or Fig 5 Upon Request) ClareHAL 104 Part No: H104 For orders or enquiries call +44 (0) 191 586 3511 Seaward, Bracken Hill, South West Industrial Estate, Peterlee, County Durham SR8 2SW United Kingdom Fax: +44 (0) 191 586 0227 Email: sales@seaward.co.uk Web: www.seaward.co.uk/hal104 Information contained within this document is for guidance only we accept no responsibility for any claim arising from this information