Operating Instructions Differential Pressure Transducer PS27

Similar documents
Instruction Manual PU/PI and PS10 Differential Pressure Transducers

Instruction Manual P82R Differential Pressure Transducer with Root- Extracted Characteristic Curve

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Serial PROFIBUS Interface

USER MANUAL. WBI414F21 AC current transducer

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

USER MANUAL. WBV412U01 AC voltage transducer

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating Instructions

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

USER MANUAL. WBI412F41 AC current transducer

GV204 Impulse Splitter for Incremental Encoders

Electronic Temperature Controller. Instruction Manual Version

Installation instructions Inclination sensor EC2019 EC / / 2013

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Operating Instructions VEGAMET 381

MINI MCR-SL-PT100-UI-200

MDM 011-Z1 Regen Resistor

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

OPERATING INSTRUCTIONS

Intrinsically safe batch controller Batching Master 110i

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

TRIO-DIODE/12-24DC/2X10/1X20

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

QUINT-BUFFER/24DC/24DC/40

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

InBin-P Pressure switches from 5 Pa Pa

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

V E1B Snap-in I/O Module

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Type Differential pressure transducer

PHOENIX CONTACT - 07/2006

VariTrans P The Problem The variety of tasks results in a large number of different devices.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

V E1B Snap-in I/O Module

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

DCM Digital Control Modules

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

V E2B Snap-in I/O Module

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

PRODUCT SPECIFICATION. PC Board Relays. Series.

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

TOXALERT MODEL AIR 2000

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

SP6R Level Controller Operation Manual

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Digital Quick-Response Thermometer

Manual Control Unit GFC 32

Operating Instructions

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

GEMS SENSORS & CONTROLS SERIES 35XX

User safety and equipment protection guidelines

Instruction Manual Differential Pressure Transducer Model P92

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Signal Doublers. VariTrans A 20300

MAXIMA+ Series Rotary Level Indicator

Products no longer available

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

Light Control SLS ADRIA

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Overview of types. Technical data

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Power consumption In operation At rest For wire sizing

User Manual Digital Input Module

Assembly instruction / User manual

ELV12 Series. Instruction Manual

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

PSBOC PSBOC 27,6V/5,5A/OC

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

SensoTrans DMS A 20220

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

MC 11 EB-2 Power supply cabinet with external bus, AC version

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Installation Instructions HIPERDRIVE HDA - with PROFIBUS DP - with cable adapter

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Hardware Manual RM CANview

Transcription:

Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com Internet: www.halstrup-walcher.com Document 7100.004354 04/2018

Contents 1. Safety Instructions... 4 1.1 Use for Intended Purpose Only... 4 1.2 Transport, Installation, Connection and Startup... 4 1.3 Malfunctions, Maintenance, Repairs, Disposal... 4 1.4 Symbols... 5 2. Description of the Transducer... 6 3. Startup... 6 3.1 Functional Description... 6 3.2 Connections for Four-Wire version (standard) in the device:... 7 3.3 Connections for Two-Wire System (Option):... 8 4. Resetting Offset... 8 5. Configuring the Output Signal... 9 6. Setting the Measuring Range (Optional)... 9 7. Display (Option)... 10 8. Setting the Relay Operating Point (Option)... 10 9. In case of Malfunctions... 10 10. Specifications... 11 11. Dimensional Drawing... 12 12. Certificate of Conformity... 13 2

Significance of the Operating Instructions These operating instructions go into the function and handling of the PS27 differential pressure transducer Use at variance to the purpose of the transducer and its incorrect operation may result in risks arising for both people and assets. That is why each and every person charged with handling the transducer must be instructed in its use and is to be aware of the dangers. Close attention must be given to these operating instructions and, in particular, to the associated safety instructions. Do contact the manufacturer should you not understand all the sections. Be heedful of the operating instructions: They must be readily available during the entire service life of the transducer. They must be passed on to the succeeding personnel charged with operations. Any additions coming from the manufacturer must be inserted. The manufacturer reserves the right to refine this type of appliance without having to document this fact in each particular instance. The manufacturer is more than willing to provide you with information on the updated nature of these operating instructions. Conformity This transducer conforms with the present stage reached in technical engineering. It complies with the statutory requirements of the EC directives. This is documented from the CE mark being affixed. 2015, 2017, 2018 The copyright to these operating instructions rests with the manufacturer. They include specifications, instructions and drawings on the function and handling of the transducer. Neither in their entirety not in part are they to be duplicated or made available to third parties. 3

1. Safety Instructions 1.1 Use for Intended Purpose Only The PS27 differential pressure transducer registers both differential pressure and positive/negative gauge pressure. The operational requirements on the rating plate and in the "Specifications" chapter - and the safe supply voltage in particular - must be kept to. The transducer is only to be handled in conformity with these operating instructions. No modifications to the transducer are permitted. The manufacturer is not liable for damage arising from any incorrect use or one at variance to the intended purpose. Claims to warranty in such an instance would be forfeited. 1.2 Transport, Installation, Connection and Startup Do not block the pressure inlets on the transducer being moved! Changes in barometric pressure may damage transducers with low measuring ranges. Only qualified personnel are to assemble the appliance and see to its electrical connections. They must be instructed as such and be assigned by the plant operator. Only instructed persons as assigned by the plant operator are to operate the transducer. Do not perform any functional test involving compressed or breathable air. This would otherwise damage those transducers with low measuring ranges. Measurement errors may occur should the appliance not be protected from sunlight. Specific safety instructions are given in the individual chapters. 1.3 Malfunctions, Maintenance, Repairs, Disposal Malfunctions which cannot be put right as specified in Chapter 8 and damage at the appliance itself must be immediately reported to the qualified personnel with responsibility for the electrical connections. The appliance must be taken out of service by the qualified personnel responsible until the malfunction has been put right and also secured against being unintentionally used. Always switch off the power to the appliance before it is opened! The appliance does not need any maintenance. Only the manufacturer is to carry out repairs. The electrical components of the transducer contain both environmentally hazardous materials and materials that can be reused. That is why the appliance is to be recycled once it is finally immobilized. The environment directives on this from the country in question must be followed. 4

1.4 Symbols The symbols below in these operating instructions point to the risks, which could arise in handling the equipment: WARNING! It points to a hazard possibly extending from injures through to death should the instructions not be followed. CAUTION! It points to a hazard which could cause considerable damage should the instructions not be followed. INFORMATION! This indicates information, which is vital for proper appliance operations. 5

2. Description of the Transducer Operating Instructions PS27 Type PS27 differential pressure transducers are pneumatic/electrical sensors for pressure testing (positive/negative gauge pressure and differential pressure) purposes. They are typically used in air-conditioning and ventilation technology e.g. pressure testing in ventilation ducts. The transducer's core is a piezoresistive pressure transducer. 3. Startup 3.1 Functional Description PS27 pressure transducers are of the precision type and despite their sturdiness they should still be treated with care. Installation right next to heat and radiation sources e.g. radiators should be avoided as this may lead to measurement errors arising. Ideally the appliance should be vertically mounted on a wall not subject to any vibrations. To stop any condensed water entering the measurement cell, the transducer together with the hose connections for positive gauge pressure + and negative gauge pressure - should be pointing downwards. The right pressure sign must be used in keeping with the following table when connecting the pressure to the transducer: Type of pressure Connect pressure to Example pos. gauge pressure + input 0...1 kpa neg. gauge pressure - input 0...- 500 Pa Differential pressure Higher pressure at + input lower pressure at - input 0...125 Pa e.g via a differential pressure producer (e.g. measuring orifice) Symmetrical pressure ranges + input 200 Pa Asymmetrical pressure ranges Input of the larger pressure range -300 Pa...+ 1 kpa (here connect to + input) 6

3.2 Connections for Four-Wire version (standard) in the device: 5 4 3 2 1 5 4 3 2 1 One measurement range Four measurement ranges Note the prescribed supply voltage (see rating plate). Also follow the connection diagram on the appliance cover / circuit board mount. ST4 Pin Connection name Meaning 1 24V Power supply input - 24VAC/DC 2 GND Ground for power supply 3 OUT Voltage or current output 4 GND Ground for output signal 5 SET 0 Zero-point input (+24V zero-point is active) The transducer outputs are protected from short circuits. The DC-supplied appliances are protected from reverse polarity of the supply voltage. 7

3.3 Connections for Two-Wire System (Option): 5 4 3 2 1 5 4 3 2 1 One measurement range Four measurement ranges ST4 Pin Connection name Meaning 1 24V +terminal 15-32VDC 2 GND Not used 3 OUT -terminal 4 GND Not used 5 SET 0 Zero-point input 4. Resetting Offset After starting the pressure transducer, give it some 15 minutes to warm up. During this time the output signal may be unstable. Zero-point calibration of the appliance is only effected via the input assigned for this purpose. The user must ensure that the appliance is not subjected to any pressure during the calibration process as this might lead to a wrong offset value which, in turn, would result in a wrong output signal. The 24V input makes it possible to activate a 3/2 directional control valve with the same signal, which switches the PS27's pressure inputs at zero pressure during the zero calibration process. In this case the zero point calibration signal must be applied until there is no doubt that the pressure has fallen to zero. While Resetting Offset is in progress, the power supply must not be switched off. This might result in a loss of the device setting and may leave the PS27 unusable. 8

5. Configuring the Output Signal Operating Instructions PS27 The user can configure the PS27's output signal. This can be done in various ways Output SW Pos 3 SW Pos 4 Comments 0 10V on off R Load > 50k Ω 2 10V on on R Load > 50k Ω 0 20mA off off max. load 500Ω 4 20mA off on max. load 500Ω The two-wire model must be configured by the manufacturer. 6. Setting the Measuring Range (Optional) The transducer with 4 measuring ranges can be adapted to the measuring assignment in question. The teaching of 4 measuring ranges into the appliance has been undertaken by the manufacturer. The switches 1 and 2 of SW can be used to select the measuring range in question before the transducer is switched on. SW Pos 1 SW Pos2 Measuring range off off 1 on off 2 off on 3 on on 4 The limiting values of the measuring ranges are noted on the label on the side of the PS27. Display-optional appliances indicate the limiting value of the selected measuring range for 1.5 seconds after being switched-on. The appliance should be re-zeroed following any measuring range change-over. This is because the amplification change-over may produce offset voltages. Four-wire: Two-wire: Pos1 Pos2 Pos1 Pos2 9

7. Display (Option) To show up the readings, the PS27 can also be fitted out with a display. The readings will be shown in either Pa or kpa depending on the limiting value of the measuring range. The number of the measuring range selected is always shown on the bottom line of the display. On switching on a display-equipped appliance, the first thing shown is the PS27 programme version followed by a 1.5 second screening of the limiting value of the selected measuring range and then the actual readings. 8. Setting the Relay Operating Point (Option) The relay operating point can be adjusted with the aid of the P2.1 potentiometer. Adjustment is easiest when the desired switching pressure is applied and the potentiometer set so that the relay is just triggered. Please note: The relay is connected to the sensor's output so that any adjusted time delay will also cause a delay in relay triggering. 9. In case of Malfunctions Fault description Possible cause Corrective action No output signal Supply voltage is not connected Incorrect supply voltage connected Defective input protection diode Only for DC power: defective reverse polarity diode Connect correct supply voltage Connect correct supply voltage (see rating plate) Send the appliance to the manufacturer for repairs Send the appliance to the manufacturer for repairs Output signal is constant despite change in pressure Output signal incorrect Defective output protection diode Pressure ports reversed Faulty pressure sensor Zeroing with pressure applied For current output: load too high For voltage output Load resistance too low Send the appliance to the manufacturer for repairs Connect the pressure as described in "3. Installation" Send the appliance to the manufacturer for repairs Renewed zeroing without pressure Note maximum 500 load Note minimum 50 k load resistance (see "7 Specifications") 10

10. Specifications Accuracy: t.c. offset: t.c. span: Measuring ranges: Min. response time: Pressure ports: Output signals: 2.0 % of the measuring range limiting value +/- 0.1 %/ C +/- 0.1 %/ C +/-2.0kPa (+/-100 Pa 2,0 kpa) +/-10 kpa (+/-2,5 kpa 10 kpa) +/-100 kpa (+/-20 kpa 100 kpa) As an option, the customer can use a DIP-switch to select 4 pre-set measuring ranges 20 ms Nominal 4 or 6 mm width for hose 0/2 10 V or. (RL> 50 kohm) 0/4 20 ma (RL< = 500 Ohm) 4 20 ma (two-wire 17 32 V,RL< = 500 Ohm) Switching contact (optional): max. 230 VAC, 6 A; min. 500 mw Display (optional): 3½-digit LCD Overload range: Range +/-2,0kPa : 10 kpa Range +/-10 kpa : 200kPa Range +/-100 kpa : 500kPa Storage temperature: Working temperature: Supply voltage: Power consumption: Operating position: Housing: -20 C...+70 C -20 C...+60 C, with Display 0 C 50 C 24 VDC/VAC +/-10 % (no galvanic isolation) 15 32 VDC (two-wire) (no relay output) approx. 1 W vertical preference see drawing Protection class: IP 65 Installation: Testing: The appliance can be installed either on a top-hat rail or on a wall with fastening holes EN 61000-4-2, EN 61000-4-3-6, EN 61000-4-11, EN V50204 11

11. Dimensional Drawing Operating Instructions PS27 For additional specifications and dimension drawings, please visit our website at http://www.halstrup-walcher.de/en/products/measurement-technology/index.php 7100.004354H_PS27_4B.doc 04/2018 Sie/Ka 12

12. Certificate of Conformity Operating Instructions PS27 13