FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

Similar documents
FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT - 02/2007

PHOENIX CONTACT - 06/2006

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000E (SM40) LC

FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E)

PHOENIX CONTACT - 11/2008

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 04/2008

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Valueline Industrial PC

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

TRIO-DIODE/12-24DC/2X10/1X20

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PHOENIX CONTACT - 07/2006

Stride Industrial Ethernet Switches

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

onlinecomponents.com

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

MINI-PS AC/10-15DC/8

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

QUINT-BUFFER/24DC/24DC/40

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial Ethernet Switch

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

PHOENIX CONTACT Features

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Hardened PoE Ethernet Switch

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

STEP-PS/1AC/24DC/1.75

Redundancy Module QUINT-DIODE/40

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI MCR-SL-PT100-UI-200

Rugged MediaConverter

IBS IL 24 RB-LK-2MBD:

onlinecomponents.com

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

PHOENIX CONTACT - 05/2007

FL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm)

QUINT-PS-3x AC/24DC/10

PSI-MODEM-SHDSL/SERIAL

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Hardened Media Converter

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

RTU500 series Data Sheet Power Supply CP-E 24/2.5

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

MINI MCR-SL-UI-2I(-SP)(-NC)

Quick Start Guide. Physical Description. The Port Status LEDs

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Industrial Switches Industrial Switches

MINI MCR-SL-PT100-UI(-SP)(-NC)

114FX6. Phone: Fax: Web: -

ETD-BL-1T-OFF-CC- 10S

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

HARTING econ 3000 Introduction and features

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

MINI MCR-SL-UI-REL(-SP)

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

PHOENIX CONTACT - 12/2007

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PHOENIX CONTACT

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

PI-EX-ME-2NAM/COC-24VDC

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

PTC-101-M12 Hardware Installation Guide

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FL MC EF WDM... Ethernet FO converter for bidirectional data transmission via a single optical fiber (SC simplex) Data sheet.

Quick Start Guide. Installation. User s Manual 1

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Transcription:

Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches can be used for quick and cost-effective Ethernet network expansion to the field level. Due to the narrow housing design, the switches are suitable for use in control cabinets and junction boxes. The switch supports the auto negotiation function and offers transmission speeds of 10/ Mbps across RJ45 ports and Mbps across fiber optic ports. Mixed operation for the connection of segments with different data transmission speeds is also supported. The RJ45 ports offer an autocrossing function, which means it is not necessary to make a distinction between 1:1 and crossover cables. Switches are available with either SC or ST multi-mode fiber optic ports. For longer distance, a single-mode fiber optic switch extends the segment to 20 km typical. Increased network performance Switched Ethernet networks reduce traffic and nonpredictable timing Easy network expansion No configuration of the switch Auto-negotiation and autocross simplify cabling Couple copper network segments with different bit rates with automatic detection of the data transmission speed of 10 or Mbps. Easy maintenance Individual LEDs at each port indicate communication activity and data rate Removable power connector Internal, resettable fuse NS 35 DIN rail (EN 60715) compatible Fiber optic ports extend distance and provide electrical noise immunity SC multi-mode, SC single-mode and ST multimode versions available Industrial rated Rugged metal housing for industrial applications -10 to 60 C operating range Meets IEC 60-6-2 electrical noise immunity Meets IEC 60068-2-6 vibration test standards Meets IEC 60068-2-27 shock test standards Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page:

3 Ordering Data Description Type Order No. Pcs./Pkt. Ethernet switch with 5 RJ45 ports 2891 1 Ethernet switch with 8 RJ45 ports 2892 1 Ethernet switch with 4 RJ45 ports and 1 SC format fiber optic port FL SWITCH SFNB 4TX/FX 2891027 1 Ethernet switch with 4 RJ45 ports and 1 ST format fiber optic port FL SWITCH SFNB 4TX/FX ST 2891028 1 Ethernet switch with 4 RJ45 ports and 1 SC format single-mode FL SWITCH SFNB 4TX/FX SM20 2891029 1 fiber optic port Accessories Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 Lockable security element for FL PATCH FL PATCH GUARD 2891424 20 Key for FL PATCH GUARD FL PATCH GUARD KEY 2891521 1 Color marker for FL PATCH GUARD, black FL PATCH GUARD CCODE BK 2891136 12 Color marker for FL PATCH GUARD, blue FL PATCH GUARD CCODE BU 2891233 12 Color marker for FL PATCH GUARD, orange FL PATCH GUARD CCODE OG 2891330 12 Color marker for FL PATCH GUARD, yellow FL PATCH GUARD CCODE YE 2891437 12 Color marker for FL PATCH GUARD, turquoise FL PATCH GUARD CCODE TQ 2891534 12 Color marker for FL PATCH GUARD, green FL PATCH GUARD CCODE GN 2891631 12 Color marker for FL PATCH GUARD, red FL PATCH GUARD CCODE RD 2891738 12 Color marker for FL PATCH GUARD, violet FL PATCH GUARD CCODE VT 2891835 12 2642_en_H PHOENIX CONT 2

4 Technical Data General Data Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor 8 μs plus frame time 9 μs plus frame time Housing dimensions (width x height x depth) 28 x 110 x 70 mm 50 x 110 x 70 mm Weight 205 g 291 g Operating temperature All models except FL SWITCH SFNB 4TX/FX FL SWITCH SFNB 4TX/FX -10 C 60 C 0 C 60 C Storage temperature -20 C 85 C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 5% to 95%, no condensation Air pressure (operation) 86 kpa to 108 kpa, 1500 m above sea level Air pressure (storage) 66 kpa to 108 kpa, 3500 m above sea level Mounting rail NS 35 (EN 60715) Preferred mounting position Perpendicular to a standard mounting rail Connection to protective earth ground Snapped onto a grounded mounting rail Supply Voltage () Connection type Removable, screw-clamp connector Wire size (solid/stranded/awg) 0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG Recommended PE wire size 2.5 mm 2 Nominal power supply 24 V DC Permissible ripple 3.6 V pp within the permissible voltage range Permissible voltage range Current consumption, nominal FL SWITCH SFNB 4TX/FX FL SWITCH SFNB 4TX/FX ST FL SWITCH SFNB 4TX/FS SM20 Inrush current maximum FL SWITCH SFNB 4TX/FX FL SWITCH SFNB 4TX/FX ST FL SWITCH SFNB 4TX/FX SM20 Test voltage Protection against polarity reversal 12 V DC 48 V DC 9VDC 32VDC 180 ma@24 V DC; 340 ma@12 V DC 138 ma@24 V DC; 272 ma@12 V DC 185 ma@24 V DC; 385 ma@12 V DC 185 ma@24 V DC; 385 ma@12 V DC 185 ma@24 V DC; 385 ma@12 V DC 15 A for 35 μs 9.1 A for 40 μs 7.2 A for 80 μs 7.7 A for 80 μs 7.7 A for 80 μs 500 V DC for one minute Present Interfaces Total number of Ethernet interfaces (RJ45) FL SWITCH SFNB 4TX MAC Address Table Size (Entries) Properties of RJ45 Ports Connection format 5 8 4 2 K 8-pos. RJ45 female connector on the switch 2642_en_H PHOENIX CONT 3

Interfaces (Continued) Connection medium Twisted-pair cable with a conductor cross section of 0.14 mm 2 to 0.22 mm 2 Cable impedance Ω Transmission speed 10/ Mbps network segment length m Properties of Fiber Optic Ports Connection format SC duplex or ST female connector Fiber type Glass Laser protection Class 1 according to DIN EN 60825-1:2001-11 Properties of Mbps Multimode Transmission rate Mbps full duplex Wavelength 1300/1310 nm Fiber optic segment length 12.1 km with glass fiber 62.5/125 0.7 db/km F0 3.3 km with glass fiber 62.5/125 2.6 db/km F600 7.1 km glass fiber with F-G 50/125 0.7 db/km F1200 3.1 km glass fiber with F-G 50/125 1.6 db/km F800 Transmission power (medium type) dynamic (average) Transmission power (medium type) static Receiver sensitivity Properties of Mbps single mode Transmission rate Fiber type Wavelength transmission length Transmission power Receiver sensitivity Mechanical Tests -23.5 dbm (50/125 μm) / -20 dbm (62.5/125 μm) -14 dbm (50/125 μm) / -14 dbm (62.5/125 μm) -22.5 dbm (50/125 μm) / -19 dbm (62.5/125 μm) -14 dbm (50/125 μm) / -14 dbm (62.5/125 μm) -31 dbm (dynamic) / -31 dbm (static) -14 dbm (dynamic) / -14 dbm (static) Mbps full duplex 9/125 μm 1310 nm 25 km with glass fiber 9/125 μm 0.5 db/km -15 dbm -3 dbm -32 dbm -3 dbm Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1 m Conformance With EMC Directives Developed according to IEC 60-6-2 IEC 60-4-2 (ESD) IEC 60-4-3 (radiated-noise immunity) IEC 60-4-4 (burst) IEC 60-4-5 (surge) IEC 60-4-6 (conducted noise immunity) IEC 60-4-8 (noise immunity against magnetic fields) EN 55022 (noise emission) Contact: ±4 kv, Criterion B Air: ±8 kv, Criterion B 10 V/m, Criterion A Ports: ±1 kv, Criterion B DC power: ±2 kv, Criterion B Ports: ±1 kv, Criterion B DC power: ±500 V, Criterion B 10 V/m, Criterion A 30 A/m, Criterion A Class A 2642_en_H PHOENIX CONT 4

Approvals General Hazardous location ROHS EEE 2002/95/EC, WEEE 2002/96/EC Class 1, Division 2, Groups A, B, C, D Temp Code T5 installed in minimum IP54 enclosure 5 Overview 5.1 Diagnostic and Status Indicators Ord.No.2891 1 2 3 4 1 2 3 4 Des. Color Status Meaning Green ON Supply voltage in the tolerance range OFF Supply voltage too low 5.2 Data Transmission Speed LEDs (2 LEDs/Port) 10 Mbps Mbps ON/blinking ON/blinking OFF ON X7 X8 LED: ON: indicates an electrical link Flashing: indicates network traffic (at high data rates the blinking is in a constant rate) 1 Power connector 2 Power LED () - green 3 LED - green 4 LED - yellow Figure 1 Housing 2642_en_H PHOENIX CONT 5

6 Installation CAUTION: Only qualified personnel may start up and operate this device. Qualified personnel are persons authorized to start up, ground and mark devices, systems, and equipment according to the standards of safety technology. NOTE: The FL SWITCH SFNB module is designed for SELV and PELV operation according to IEC 61140/EN 61140. Install the FL SWITCH SFNB on a clean mounting rail. To avoid contact resistance only use clean, corrosion-free mounting rails that meet the EN 60715 standard. End clamps can be mounted on both sides of the module to stop the modules from slipping on the rail. NOTE: Connect the mounting rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the rail. Connect protective earth ground with low impedance. 6.1 Assembly 1. Place the module onto the rail from above. The upper holding keyway must be hooked onto the top edge of the rail. 2. Push the module from the front towards the mounting surface. 3. Once the module has been snapped on properly, check that it is fixed securely on the rail. by an additional low-impedance connection to functional earth ground (see Figure 2). Figure 2 Power connections Use power conductors between 0.2-2.5 mm² (24-12 AWG). Torque connection screws to 0.5-0.6 Nm (5-7 lb-in.). 6.4 Ethernet Interface The FL SWITCH SFNB has either five or eight Ethernet ports on the front in RJ45 format to which only twisted-pair cables with an impedance of Ω can be connected. The data transmission speed is 10/ Mbps. In addition, every port has an auto crossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet cables. + GND RJ45 24 V DC 6.2 Removal 1. Insert a suitable tool (e.g., needle-nose pliers) into the arresting latch and pull it down. 2. Pull the module slightly away from the mounting surface. 3. Lift the module from the rail. 6.3 Power Connection The switch is designed for SELV and PELV operation at +24 V DC according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. Snapping the switch onto a grounded mounting rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased Figure 3 8 7 6 5 4 3 2 1 n.c. ṬD-n.c. n.c RD- n.c ṪD+ RD+ RJ45 pin assignment 2642_en_H PHOENIX CONT 6

6.5 Fiber Optic Connection Two different types of fiber optic connection are available. The ST connectors are typically individual round connectors and use a 1/4-turn connection. The SC connectors have a square interface and the conductors are typically locked together through the connector. SC Connectors TD ST Connectors 1 00 TD 8 Dimensions Ord.No.2891 14 mm RD TD RD RD 110 mm Figure 4 Fiber optic ports X7 X8 7 Switching Characteristics Store and Forward All data telegrams received by the switch are saved and their validity checked. Invalid or faulty data packets (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. Multi-Address Function The switch independently learns the addresses for termination devices, which are connected via a port, by evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. A restart deletes the entire address table. 28 mm Depth = 70 mm Figure 5 Housing dimensions 50 mm 2642_en_H PHOENIX CONT GmbH & Co. KG 32823 Blomberg Germany Phone: +49-(0) 5235-3-00 7 PHOENIX CONT P.O. Box 4 Harrisburg PA 17111-0 A Phone: +717-944-1300 www.phoenixcontact.com