Linear Actuators (235N)

Similar documents
ASI Systems ML5720A Series

ASI Systems ML5740A Series

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Type Electrically Actuated 3-way Ball Valves

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

VA Electric Terminal Unit Actuator. Benefits. Technical Specifications. Double colour LED. Low and line voltage.

Data Sheet A200 Series Electric Actuators

Motorised actuator 0-10V EAC

24V, Motorized Actuators

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Rotork Fairchild PAX1 Linear Actuator User s Manual

Overview of types. Technical data

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

PGR-3200 MANUAL INSULATION MONITOR

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Power consumption In operation At rest For wire sizing

Proportional Control Unit (PCU)

Technical data sheet. Technical data

ETV Control ETV Valve

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AF24-MFT (-S) US Proportional damper actuator, Spring Return Fail-Safe, Multi-Function Technology

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

COMMERCIAL. VAM24-90-(A) Series

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

COMMERCIAL. VAM24-90-(A) Series Installation Instructions

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Networkable Dual Duct VAV Controller Specification and Installation Instructions

ML7421A,B Electric Linear Valve Actuators

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Modulating controlled actuator AME 11

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Instruction Sheet Board Style Low Water Cutoff

MCS-2015 Basic power supply for on-off and emergency 115 VAC Electrak 1 stop. 115 VAC or 230 VAC input. 230 VAC Electrak 10 Electrak 100

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Electromotive actuators for combi valves

Actuator Commissioning Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VA-748x Electric Valve Actuators

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

MVE5xxR. Globe Valves Actuators with Emergency Fail Safe Function DESCRIPTION POWER SUPPLY [N] APPLICATION AND USE OPERATION

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

ECM3000. Control Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

User Guide True RMS Multimeter Extech EX205T

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Digital ac/dc (24V) Input Module

Zone Pressure Touch (ZPT) Sensor - Standard Range

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Zone Pressure Touch Sensor - Standard Range

Installation, Operation and Maintenance Manual

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

General-Purpose Photoelectric Sensor

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

Zenith DS9000 Dispensing System

NovoCon S Digital/Hybrid - High Accuracy Actuator

P216 Series Condenser Fan Speed Controller

STAC5 Stepper Drives. A high performance, compact and cost-effective stepper drive with advanced features and control options

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

clarity 3 VAV Programmable Controller

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

RCx-xxxAx Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

Control Motor ECM3000

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

MaxStepper Serial Step and Direction Pulse Generator. User Manual

P2-04DA Analog Output. Removable Terminal Block Specifications

OPERATING INSTRUCTIONS

Transcription:

Features: Force limiting adaptor Digital or analog models Patented Enerdrive Fail-Safe System* (optional) Auto stroke on power up (analog models) Simple manual override Direct or reverse acting (configurable) Status LED Standard cable 1 meter (3.2 ft) long Easy installation, no tools required Small size allows for easy installation in limited space Stall-proof, maintenance free Anti-stick option (analog models) IP54 enclosure FN.0.2 FN.0.4 FN.1.2 FN.1.4 * Enerdrive Fail-Safe System: US Patent # 5,278,454 European Patent # 0647366 with Failsafe option Description Actuator Technical Data FN.0.2 FN.1.2 FN.0.4 FN.1.4 Force (range) 220N to 270N (minimum 220N during the lifetime of 30,000 cycles) Power supply 22 to 26 Vac or 22 to 26 Vdc 100-250Vac 50/60Hz Power consumption 5VA 10VA peak, 6VA 5VA 10VA peak, 6VA 5VA Impedance > 30K Ω > 30K Ω 4.7K Ω 4.7K Ω 400K Ω Electrical connection Halogen free cable 0.8 mm 2 [18AWG], 1 m (3.2 ft) long 4 wires for FN.0.2, FN.1.2, FN.1.4 3 wires for FN.0.4, Control mode & signal Analog, 0-10Vdc, 2-10Vdc, or 3 wire/2 position 4-20mA (w/ external 500Ω resistor) 3 wire 4 wire 3 point floating 3 point floating Feedback signal 0-10Vdc or 2-10Vdc No feedback Running time 18.5 sec/mm - 120 sec for 6.5mm Failsafe running time 9.2 sec/mm 9.2 sec/mm 60 sec for 6.5mm 60 sec for 6.5mm Direction Reversible, normally up position (close) or normally down position (open) Force Limiting Adaptor Stroke Up to 6.5 mm [¼ in] 14.3mm [+0.3mm / -0.0mm] 3 wire 3 point floating Actuator top position (fully open) Thread type (actuator to valve) Materials Environmental and Other M30x1.5 - Valve adaptor (4) legs (MA073): PA66+50%GF - Union with thread (MA028): SAE1010+Trivalent Chromate (RoHS) Ambient temperature -18ºC to 50ºC [0ºF to 122ºF] Storage temperature -30ºC to 50ºC [-22ºF to 122ºF] Relative Humidity 5 to 95 % non condensing Weight 240g [0.5 lbs] 295g [0.65 lbs] 246g [0.55 lbs] 295g [0.65 lbs] 246g [0.55 lbs] Certifications / Standards CE, UL, IP54* (* IP54 Equivalent to NEMA type 3R) CE, IP54* Enclosure Materials Top (MA041-3 & MA050-1): ABS+10%GF, UV, FR Bottom (MA040): ABS, UV, FR Serigraphy on enclosure White on black Firmware (FlowCon 40 x 5 mm) V301 X_FL3(NEP)-171013-Rev07.docx Page 1

Dimensions FN.0.2 / FN.0.4 / A FN.1.2 / FN.1.4 (with failsafe) A A = 2.00 51mm B = 4.09 104mmm C = 3.62 92mm B A = 2.00 51mm B = 4.09 104mm C = 4.18 107mm B adaptor: BWMA520 C adaptor: BWMA520 C Mechanical Installationn Correct mounting Incorrect mounting 1. The actuated valve installation should be easily accessible and provide sufficient clearance for servicee and replacement. 2. Horizontal and vertical positions are preferred orientation for the installation of actuated valve. However, this actuator can be installed at any in between angle. Caution: Do not install at more than 90º from horizontal. KNOB MANUAL OVERRIDE FORCE LIMITING ADAPTOR (MA500) 1. Ensure the actuator is disengaged from the valve adaptor. To do so, press the release button while turning the actuator CCW 30º. 2. Mount the valve adaptor to the valve and finger- tighten only. 3. Rotate knob counter clockwise (CCW) to open the valve. Do not force knob in either direction! 4. Manually adjust the knob to test piping network. 5. Once satisfied that the network is working properly, engage the actuator over the valve adaptor and turn 30º clockwise (CW). You should hear an audible click. To disengage the actuator, press the release button while turning the actuator CCW 30º. Caution: The actuator is specifically calibrated to its adapter. Do not exchange original adapter with a different actuator. WARNING! You must connect the actuator to its adaptor and mount it on a valve before applying power. Failure to do so will result in incorrect operation of the actuator. If you plan to add foam insulation, do not add insulation foam beyond the chrome ring and around the adaptor. Improper installation of insulation material could lead to a build-up of condensatee water around the valve and the chrome ring of the adaptor, which could lead to build up of rust and compromise the structure of the chrome ring that holds the adaptor. Caution We strongly recommend that alll Neptronic products be wired to a separate grounded transformer and that transformer shall service only Neptronic products. This precaution will prevent interference with, and/or possible damage to incompatible equipment. www.neptronic.com Page 2

Wiring: Analog Models FN.0.2 & FN.1.2 Analog 500 Ohms Optional: Add 500 Ohms resistor (1%/0.25W) between BLK and WHT to use 4-20mA control signal. DIP switch 3 must be set to OFF ANALOG SIGNAL FEEDBACK Wiring: Digital Models Please note that the following wirings are shown for the Normally Closed (rotation direction). With the normally open setting, the red wire becomes open and the white wire becomes closed. FN.0.4 & 3-wire / Digital 2 positions FN.0.4 & 3-wire / Digital 3 point floating FN.0.4 = = 100-250 Vac FN.1.4 3-wire / Digital 2 positions FN.1.4 4-wire / Digital 3 point floating DIP Switches Each model has a different number of DIP switches, which are located behind the translucent silicon cap at the back of the actuator. Please read the following sections carefully for detailed information on the options. DIP switches can be changed at any time. The changed option (DIP switch setting) takes effect immediately. If a change is made during an Auto-Stroke sequence (analog models only); the change takes effect once the Auto-Stroke sequence is complete (up to 240 seconds). Settings: Analog Models Auto-Stroke Analog actuators perform an Auto-Stroke sequence upon every power up. The Auto-Stroke sequence runs from 0 to the end position and back in order to automatically detect the stroke limits and calibrate the input signal to the detected stroke limits. The Auto-Stroke sequence can take up to a maximum of 4 minutes to complete. During the Auto-Stroke sequence the status LED remains on and the actuator will not perform any other action. If the actuator and/or adaptor are removed from the valve after initial installation, you must initiate an Auto- Stroke sequence to recalibrate the actuator. To do, remove power and reapply power Anti-Stick Option If activated, the actuator makes one full cycle every day if no action or motion has been applied in the last 24 hours. This operation clears up any possible impurities accumulated on the plug and seat of the valve. Activate the Anti-Stick option by setting DIP switch #2 to the ON position. During the Anti-Stick cycle, the actuator will not react to a control signal. Do not activate the Anti-Stick option in case of incompatibility with your application. www.neptronic.com Page 3

Settings: Analog Models FN.0.2 (Analog) FN.1.2 (Analog with Fail Safe) Rotation Direction The motor direction of the analog actuators is reversible. By default the actuator is set to reverse acting (DIP switch #1 = ON). Reverse Acting (default) DIP Switch #1 = ON Direct Acting DIP Switch #1 = OFF Enerdrive* Fail Safe System The Enerdrive* system is a patented method of storing energy (using super capacitors) that is later used drive the actuator to its failsafe position during a power failure. It takes approximately 90 seconds to fully charge the Enerdrive* system. With the restoration of power, the actuator immediately resumes operation and the Enerdrive* system is recharged. Use DIP switch #2 to set the actuator to respond according to the application requirements. Fail Safe Direction Final position during fail safe operation www.neptronic.com Page 4

Settings: Digital Models FN.0.4 & (Digital) FN.1.4 (Digital with Fail Safe) Stickers: Analog Models FN.0.2 FN.1.2 Sticker Placement (all models) Stickers: Digital Models FN.0.4 FN.1.4 www.neptronic.com Page 5