POSITILT CAN SAE J1939 Output Specification

Similar documents
POSITILT - PTAM / PTDM

POSITILT - PTAM/PTDM

Analog output linear. Wear free, high resolution High shock resistance Servo flange mounting U8 I1

Device manual Inclination sensor 2 axes JN /00 04/2015

Device manual Inclination sensor 2 axes. JN2301 from firmware /00 05/2016

INDUSTRIAL INCLINOMETER SAE J1939 INTERFACE

POSIROT. PRAS26 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

Encoder WDGA 36A CAN SAE J1939

PowerKey 1000 J1939 user manual

Encoder WDGA 36E CAN SAE J1939

POSIHALL. Magnetic Multiturn Angle Sensors Product catalog

DS WIRE INTERFACE 11 DECOUPLING CAP GND

POSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

SAE J1939. Serial Control and Communications Vehicle Network. Presented by Wilfried Voss

Inclination sensors 2-dimensional, measuring range up to ±90

J1939 user manual. Summary: PowerKey pro series

SAE J1939. Serial Control and Communications Vehicle Network

Specification G-NSDOG2-200

PRELIMINARY. Preliminary Technical Datasheet #TDAX Discrete I/O P/N: AX inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Eaton E32 3-switch modules

Current ma Redundant second channel as option

PKP-2200-SI J1939 USER MANUAL THE PRESENT MANUAL IS FOR REFERENCE ONLY AND MIGHT BE NOT UP TO DATE TO THE LATEST VERSION.

J1939/Modbus Slave Gateway FAQ

ACS HEAVY DUTY INCLINOMETER SAE J1939 INTERFACE

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

Inclination sensors 1-dimensional, measuring range

DS1625. Digital Thermometer and Thermostat FEATURES PIN ASSIGNMENT

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

Technical Manual Series M3658, M3678

GW-7228 J1939/Modbus RTU Slave Gateway

Protection class. ±0.35% f.s., other values on request. Protection class IP50

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

EM23-DIN COMMUNICATION PROTOCOL. Version 0 Revision 0

J1939 OVERVIEW. 1

J1939 USER MANUAL POWERKEY PRO SERIES

GIGAVAC Contactors J1939 Protocol

Digital Thermometer and Thermostat

Ergonomic joystick for parallel arrangement in the tightest installation spaces

PLC2 Board Communication Manual CANopen Slave

DS Wire Digital Thermometer and Thermostat

Applications: Stationary, portable power generator sets Genset control systems

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

J1939-based application profiles

DS75 Digital Thermometer and Thermostat

IFC 100 Supplementary instructions

Digital Thermometer and Thermostat in SOT23

DS1821 Programmable Digital Thermostat and Thermometer

READ/WRITE MODULES (RWM) RLS

User Reference Manual

GE Fanuc IC694ALG221. Rx3i PacSystem

Single-Wire, I/O Powered 1-Kbit (128 x 8) Serial EEPROM with a Unique, Factory-Programmed 64-Bit Serial Number

ORDERING INFORMATION. OPERATION Measuring Temperature A block diagram of the DS1621 is shown in Figure 1. DESCRIPTION ORDERING PACKAGE

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

ECOTRONS CAN USB CAN Bus. Support Windows XP, Windows 7 and Windows 10. CAN baud rate can be set anywhere between 5 Kbps and 1 Mbps

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

DS1855 Dual Nonvolatile Digital Potentiometer and Secure Memory

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

DS1821 Programmable Digital Thermostat and Thermometer

SCHMIDT Sensor interface PROFIBUS Instructions for use

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

MRUC-20 Modul-R CAN Bus Network

E/A CAN. I /O Module for CAN Networks. Product Manual E-V0305.doc

icex-cmtm General specs and Installation guide

Optimized for V CC range of 1.7V to 3.6V. 2-wire serial interface: I 2 C Fast Mode Plus (FM+) compatible

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 1

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

1.Overview of X7083/X7043/X7023

DS1631/DS1631A/DS1731 High-Precision Digital Thermometer and Thermostat

EM21 COMMUNICATION PROTOCOL. Version 1 Revision 0

Linear-Encoders CANopen Profile

DS1845 Dual NV Potentiometer and Memory

EM24-DIN PFA, PFB & X models

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0

PART IN+ IN- TX_DISABLE TX_FAULT BIAS SET BIASMAX 2 APCSET 2 MODSET 2 MOD SET PC_MON BS_MON

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )

Zone monitoring device TGÜ-BS 2.6 (Slave) for car parks

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

TLP100 INCLINATION SENSOR MEMS technology with High resolution

EM271 COMMUNICATION PROTOCOL. Version 0 Revision 0

FM3104/16/64/256 Integrated Processor Companion with Memory Features

WIE485 and WIE232. Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers

Touch Encoder. Interface Control Document (CANBUS J1939 Protocol)

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 3

POSIROT / PRAS. Analog Magnetic Angle Sensors. Instruction Manual. Please read carefully before installation and operation!

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

Device manual Encoder with CANopen interface RM7 RN7

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

Linear-Encoder Multi-Sensor CANopen Profile

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

EM270 COMMUNICATION PROTOCOL. Version 1 Revision 0

RS485 MODBUS Module 8I8O

FM3104/16/64/256 Integrated Processor Companion with Memory Features

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual

Hardware Manual RM CANview

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

DS1624 Digital Thermometer and Memory

MIC-2 MKII Profibus module user s manual

Transcription:

CAN SAE J1939 Output Specification Description Inclination sensor according to standard SAE J1939. Configuration of operating parameters by proprietary-a- Message (peer-to-peer connection). Process data exchange by proprietary-b-message (broadcast). Interface J1939 CAN specification Transceiver Communication profile Baud rate Internal temination resistor Address ISO 11898, Basic and Full CAN 2.0 B 24V-compliant, not isolated SAE J1939 250 kbit/s 120 Ω Default 247d, configurable NAME Fields Arbitrary address capable 1 Yes Industry group 0 Global Vehicle system 7Fh (127d) Non specific Vehicle system instance 0 Function FFh (255d) Non specific Function instance 0 ECU instance 0 Manufacturer 145h (325d) Manufacturer ID Identity number 0nnn Serial number 21 bit Parameter Group Numbers (PGN) Configuration data PGN EFddh Proprietary-A (PDU1 peer-to-peer) dd Sensor Node ID Process data PGN FFnnh Proprietary-B (PDU2 broadcast); nn Group Extension (PS) configurable Specifications Excitation voltage 8... 36 V DC Excitation current 15/30 ma typical for 24/12 V, 100 ma max. Measuring rate 1 khz standard Stability (temperature) ±100 x 10-6 / C f.s. Repeatability 1 LSB Operating temperature -40... +85 C Protection Reverse polarity, short circuit EMC EN61326-1:2006 ASM GmbH MAN-PT-E-11 17

Setup procedure Node-ID The default Node-ID the sensor will claim on power up is user or factory configurable. The user can configure by Commanded Address service according to the J1939 standard or by Peer-to-Peer message as described below. User configuration User accessible parameters including node-id may be configured by peerto-peer proprietary A message PGN 0EF00h. The parameters are accessed by byte-index and read/write operations coded in the data frame. The slave will return the data frame including the acknowledge code. Parameter values will be effective immediatly. On execution of Store Parameters the configuration is saved nonvolatile. Peer-to-peer message (PGN 0x00EF00), send/receive format PGN HIGH PGN PGN LOW (Node-ID) Request: Control Unit Sensor 8 Byte data frame Index Rd/Wr 0 Ack 4-Byte Data 0EFh dd i 0/1 0 0 LSB.... MSB Response: Control Unit Sensor 0EFh cc i 0/1 0 a LSB.... MSB a: Acknowledge codes: 0: Acknowledge, 81: Read only parameter, 82: Range overflow, 83: Range underflow, 84: Parameter does not exist dd: Sensor Node-ID (Default 0F7h, 247d) cc: Control-Unit Node-ID Warning notice Changing the parameters can cause a sudden step of the instantaneous value and can result in unexpected machine (re)actions! Precautions to prevent danger for man or machine are necessary! Execute parametrizing at standstill of the machine only! 18 MAN-PT-E-11 ASM GmbH

Configuration examples Example: Set Transmit Cycle to 10ms, Index 31, Node-ID 247d (F7h) PGN HIGH PGN LOW 8 Byte data frame 0EFh F7h 1Fh 01h 00 00 0Ah 00 00 00 0EFh cc 1Fh 01h 00 00 0Ah 00 00 00 Example: Read Transmit Cycle value, Index 31 0EFh F7h 1Fh 00 00 00 00 00 00 00 0EFh cc 1Fh 00 00 00 0Ah 00 00 00 Example: Store Parameters permanently, Index 28 0EFh F7h 1Ch 01h 00 00 65h 76h 61h 73h 0EFh cc 1Ch 01h 00 00 65h 76h 61h 73h Example: Reload factory defaults, Index 29 0EFh F7h 1Dh 01h 00 00 64h 61h 6Fh 6Ch 0EFh cc 1Dh 01h 00 00 64h 61h 6Fh 6Ch ASM GmbH MAN-PT-E-11 19

Configurable parameters Parameter Index [dec] Default Range / Selection Unit Read / Write Control Node ID 20 247 128... 247 1) Baude rate 21 3 (250kB) - 1) Termination resistor 22 0 0 (OFF) 1 (ON) 1) Store parameters 28 - save 2) wr Reload factory defaults 29 - load 2) wr Communication Transmit mode 30 0 0 timer 1 request 2 event Transmit cycle 31 100 10..65535 ms PGN Group Extension 32 0 0..255 Event mode hysteresis 38 0 0..16383 steps Process data byte order 39 0 0 little / 1 big endian Measurement 1 axis ±180 0: 1 axis 69 1 2 axes ±60 80h: 2 axis Code sequence_x 70 0 0 CW 1 CCW Code sequence_y 71 0 0 CW 1 CCW Resolution (in 0.001 ) 73 100 10... 10000 deg Preset 1 axis X/Y 74 0 ±0,1.. deg Preset 2 axes X 75 0 ±0,1.. deg Preset 2 axes Y 76 0 ±0,1.. deg Averaging Filter 77 1 1...255 Identification SW Version 198-4 bytes number rd Serial number 199 4 bytes number rd Identity number 200-21 bit number rd 1) Effective on next power-up 2) save MSB...LSB: 73h, 61h, 76h, 65h load MSB...LSB: 6Ch, 6Fh, 61h, 64h Depending on configuration ordered default settings may be different, refer to ASM homepage. 20 MAN-PT-E-11 ASM GmbH

Process data Process data are transmitted by broadcast proprietary-b-message PGN 0x00FFxx where the low byte is configurable. Data field of process data B7 B6 B5 B4 B3 B2 B1 B0 Error Inclination Y Inclination X Byte *) MSB LSB MSB LSB *) Error codes: 0 = no error, 1 = error ASM GmbH MAN-PT-E-11 21

Connecting cables Signal wiring / connection Signal name Connector pin Shield 1 Excitation + 2 GND 3 CAN-H 4 CAN-L 5 View to sensor connector CAN bus wiring Connect the device by a T-connector to the CAN trunk line. Total length of stubs should be minimized. Connect terminating resistors 120 Ohm at both ends of the trunk line. Terminating resistor Cable T Cable T T Terminating resistor * Device 1 Device 2 Device n * Only if device n has no internal terminating resistor 22 MAN-PT-E-11 ASM GmbH