A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

Similar documents
Installing the DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards in the Cisco ONS MA

Ethernet Cards. 5.1 Card Overview CHAPTER

Hardware Specifications

Optical Cards. 4.1 OC-N Cards OC-N Card Overview CHAPTER

Hardware Specifications

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.

Cisco ONS CL Shelf Assembly Hardware

Hardware Specifications

Install the Cisco ONS CL

Ethernet Cards. 5.1 Ethernet Card Overview CHAPTER

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

Card Protection. 4.1 Overview CHAPTER

Install the Cisco ONS CL

Optimux-34, Optimux-25

DWDM Cards. 6.1 DWDM Card Overview CHAPTER

Cisco ONS MA Shelf Assembly Hardware

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

Optimux-34 Fiber Optic Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

Installing Cisco ONS SONET/SDH MRC-12 Cards

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Optimux-4T1 Four-Channel T1 Multiplexer

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

Loop-O9330 Fiber Optical Mux

16 x E1 G x Ethernet optical multiplexer

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

FCD-155 STM-1/OC-3 Terminal Multiplexer

V C ALIANT OMMUNICATIONS. STM-1 Optical to STM-1 Electrical Converter. Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

Installing ONS SDH OC3 IR 4/STM1 SH 1310 Cards

Gmux Modular TDMoIP Gateway FEATURES

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

5U CWDM Managed Platform SML-5000

Optimux-1032, Optimux-1025

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

IPmux-1E. TDMoIP Gateway FEATURES

Cisco ONS MA Shelf Assembly Hardware

VCL-TP, Teleprotection Equipment

Specifications FOX Matrix 3200/7200/14400/320x Series, SMX 88/1616 FOX

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

Traverse System Documentation. Installation and Commissioning Guide

Optimux-108, Optimux-106

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc.,

FLASHWAVE 4100 Multiservice Provisioning Platform

ISO 9001:2000 Certified Company

Loop-O 9300 Fiber Optical Mux

Installing ONS SDH FMEC-E3/DS3 Cards

WaveReady WRT-882. Dual 10 G Tunable Transponder

4xT1/E1 i nline probe ASE With LinkSafe capabilities

SONET Topologies and Upgrades

Prisma II Platform. Optoelectronics

WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

FOMi-40 Fiber Optic Modem with Remote Management

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

Cisco Prisma II Platform

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

ASMi-54 SHDSL.bis Modem

Mechanical. Chassis CHAPTER

Cisco MDS 9000 Family Pluggable Transceivers

Separate Video from Audio and Peripheral Data

TECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure

Cisco Series Gigabit Ethernet Half-Height Line Card

2/4-wire SHDSL Modem/Multiplexer

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

D9408 Advanced ATM Adapter

Cyan Z22 Platform. Edge-Optimized P-OTP. Introduction. Benefits

Product Overview CHAPTER

FCD-155 STM-1/OC-3 Terminal Multiplexer

IPmux-16 TDM Pseudowire Access Gateway

Optimux-108, Optimux-106

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

Multiservice Network Termination Unit

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

Where to buy > Product page >

SONET Topologies and Upgrades

Protocol/interface converter series

MARKET SEGMENTS AND APPLICATION

ORION TELECOM NETWORKS INC.

- 128 x Gigabit Ethernet connections - 32 x 4G Fibre Channel connections - 8 x 8G Fibre Channel connections - down to 2 Mbps

Installing the TXP_MR_10E_C and TXP_MR_10E_L Cards in the Cisco ONS SONET/SDH

ORION TELECOM NETWORKS INC. STM-1 (Optical / Electrical) Add-Drop Multiplexer (with upto 16 E1 & 4 Ethernet) SDH Equipment

Cisco ONS MA SONET Multiservice Platform

TECHNICAL SPECIFICATION. Brocade 7800 Extension Switch Technical Specifications

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

Separate Video from Audio and Peripheral Data

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

1-Port Gigabit Ethernet Line Card Overview

VE883. 4K HDMI Optical Extender (K1, MM) / 10km (K2, SM))

Transcription:

APPENDIX A Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This appendix contains shelf, card, and Small Form-factor Pluggable (SFP) specifications for the Cisco ONS 15310-CL and Cisco ONS 15310-MA. A.1 Cisco ONS 15310-CL Shelf This section includes hardware and software specifications. A.1.1 Bandwidth The following bandwidth specifications apply to the ONS 15310-CL: Total bandwidth: 2.054 Gbps Optical: 1.24 Gbps (2 x OC-12) Electrical: 188 Mbps Expansion: 622 Mbps (OC-12) A.1.2 Expansion Slot Total card slots: 1 expansion slot for CE-100T-8 and ML-100T-8 cards. A blank card (15310-EXP-FILLER) can also be plugged into the expansion slot. A.1.3 Internal Cards The following internal cards are available in the ONS 15310-CL: 15310-CL-CTX card A-1

A.1.4 15310-CL-CTX Appendix A Interconnect card Connector expansion card A.1.4 15310-CL-CTX The 15310-CL-CTX card has the following specifications: Optical ports Two user upgradeable and hot swappable SFPs with SONET interface support Support for multirate SFPs (155.520 Mbps and 622.080 Mbps) Support for operating the two optical facilities at different line rates in unprotected facility mode (non 1+1 Automatic Protection Switching [APS] operation) DS-1 ports Supports Telcordia GR-499-compliant 1.544 Mbps (DS-1) interface Performance monitoring (PM) is provided through the interface to allow validation of signal quality. Any outgoing DS-1 signal can be retimed to eliminate accumulated jitter and wander at the point of egress from a synchronous network. Any incoming T1 signal from the transport element can also be used as a timing source. DS-3/EC1 ports Supports Telcordia GR-499-compliant 44.736 Mbps (DS3) interfaces or EC1. PM is provided through the interface to allow validation of signal quality. Each port can be provisioned in any combination of DS-3 or EC1. Building integrated timing supply (BITS) Supports one BITS input and one BITS output The BITS I/O ports support a 100-ohm termination for external 1.544 Mbps DS1 timing signals. Alarm LAN The alarm system provides three alarm inputs and two contacts for alarm outputs. Supports a 10/100-Mbps Ethernet interface for Cisco Transport Controller/Transaction Language One (CTC/TL1) provisioning. For node access in secure mode, SSL (for TL1) and HTTPS (for CTC) security protocols are supported. Craft interface An EIA/TIA-232 craft interface is provided and is used for TL1 provisioning. The craft interface is set to 9600 baud, no parity, and 1 stop bit by default. 64-kbps user data channel (UDC) digital interface The 6- kbps digital interface provides a digital input and output. Any F1 byte that is accessible on the system is interfaced at the UDC connector. The UDC provides a simplex interface. Protection for UDC overhead channel(s) follows interface line protection for traffic. A-2

Appendix A A.1.5 Configurations The UDC can be enabled or disabled through the management interfaces. The default state is disabled. The UDC supports a 64-kbps serial interface adaptation function to overhead byte F1. The physical interface is defined in ITU-T G.703 as a 120-ohm, twisted pair connection. The jitter specification is defined in ITU-T G.823. The physical interface is defined in ITU-T G.703 as a 120-ohm, twisted pair connection. The jitter specification is defined in ITU-T G.823. The UDC supports a serial port interface adaptation function to overhead bytes F1. This is an EIA/TIA-232 interface capable of 9.6-, 19.2-, 38.4-, and 56-kbps operation. The rate is selectable through the management interface. The default is 56 kbps with no parity and 1 stop bit. A.1.5 Configurations The ONS 15310-CL supports the following configurations: Two-fiber path protection 1+1 protection Path protected mesh network (PPMN) Add/drop multiplexer (ADM) Point-to-point (PPP) terminal mode A.1.6 Cisco Transport Controller CTC, the ONS 15310-CL graphical user interface (GUI), has the following specifications: 10/100BaseT 15310-CL-CTX access: RJ-45 connector A.1.7 TL1 Craft Interface TL1, the ONS 15310-CL craft interface, has the following specifications: Speed: 9600 baud, no parity, 1 stop bit 15310-CL-CTX: EIA/TIA-232 with RJ-45 type connector A.1.8 LEDs Table A-1 describes the possible LED colors and their significance. A-3

A.1.9 Alarm Interface Appendix A Table A-1 LED FAIL ALARM PWR SYNC LED Description Color Red for system failure or during initialization Red (Major and Critical) Amber (Minor) Green (AC source present or both DC sources present) Amber (one DC source present) Green (primary and secondary reference synchronization) Amber (only one reference) Red (loss of both references) A.1.9 Alarm Interface The ONS 15310-CL alarm interface has the following specifications: Visual: Critical (red LED), Major (red LED), Minor (amber LED) Three alarm inputs and two alarm contacts, all on the same RJ-45 connector (ALARM port) A.1.10 DS1 Interface The ONS 15310-CL DS-1 interface has the following specifications: 21 DS-1 (1.544 Mbps) ports Connector: LFH96 (100-ohm balanced) Any two ports can be used as primary and secondary timing sources A DS01 output can be retimed to system clock on a per-port basis A.1.11 DS3/EC1 Interface The ONS 15310-CL DS3/EC1 interface has the following specifications: Three DS3 (44.736 Mbps)/EC1 (51.84 Mbps) ports Connector: 75-ohm mini-bnc connector Ports can be any combination of DS-3 and EC-1 A.1.12 Nonvolatile Memory The ONS 15310-CL nonvolatile memory has the following specifications: 128 MB, Compact Flash card A-4

Appendix A A.1.13 BITS Interface A.1.13 BITS Interface The ONS 15310-CL BITS interface has the following specifications: One DS-1 BITS input One derived DS-1 output A.1.14 Push Buttons The ONS 15310-CL has the following push buttons: Lamp test: When momentarily pushed, lights all LEDs on the ONS 15310-CL front panel. If an LED has more than one color, all the colors will be cycled when the lamp test button is pushed. Note Another use for the lamp test button is to reset the CTC password to its default value (otbu+1). To reset the password, press the lamp test button for at least five seconds, release it for a maximum of five seconds, then press it again for at least five seconds. After the button is released, the default password is set. System reset: When pressed, performs a soft reset (does not impact traffic). A.1.15 System Timing The ONS 15310-CL has the following timing specifications: +/ 20 ppm SONET Minimum Clock (SMC) free-running internal clock Maintains SMC holdover (+/ 4.6 ppm for first 24 hours) in the event of reference frequency loss Timing reference: External BITS, line optical port, any DS-1 clock, and internal clock A.1.16 Power The ONS 15310-CL has the following power specifications: Input power: 48 VDC (dual DC power supply model) or 100/240 VAC (AC power model) Maximum power consumption DC chassis with no expansion board: 60 W DC chassis with expansion board: 115 W AC chassis with no expansion board: 70 W AC chassis with expansion board: 140 W Power requirements: 42 to 56 VDC or 100/240 VAC (+/ 10 percent) Power terminals: Three-prong male locking connector for DC power supply model or three-prong male AC connector for AC power model Note An ONS 15310-CL that uses DC power is classified as DC-I (DC Isolated). This means that the DC return (RET) conductor at the DC power input connector is not bonded to the chassis frame ground. A-5

A.1.17 Environmental Appendix A A.1.17 Environmental The ONS 15310-CL has the following environmental specifications: Operating temperature: 0 to +55 degrees Celsius (32 to +131 degrees Fahrenheit) for AC chassis; 40 to +65 degrees Celsius ( 40 to +149 degrees Fahrenheit) for dual-dc chassis Operating humidity: 5 to 95 percent, noncondensing A.1.18 Shelf Dimensions The ONS 15310-CL has the following shelf dimensions: Height: 1 Rack Unit (RU), 1.75 inches (4.45 cm) Width: 19.0 inches (48.3 cm) 23.0 inches (58.4 cm) including rackmount brackets Depth: 15.0 inches (38.1 cm) sheet metal only 15.8 inches (40.2) including mini-bnc and DC inlet connectors Weight: 11.5 lb. empty 12.5 lb. maximum (line card installed) A.2 Cisco ONS 15310-MA Shelf This section provides ONS 15310-MA topologies; Cisco Transport Controller (CTC) specifications; LAN, TL1, modem, alarm, and electrical interface assembly (EIA) interface specifications; timing, power, and environmental specifications; and shelf dimensions. A.2.1 Alarm Interface The ONS 15310-MA alarm interface has the following specifications: The alarm interface provides 32 alarm inputs and 8 contacts for alarm outputs. Connector J6: Alarm inputs Connector J7: Alarm outputs A.2.2 UDC Interface The ONS 15310-MA 64-kbps user data channel (UDC) digital interface has the following specifications: The 64- kbps digital interface provides a digital input and output. Any F1 byte that is accessible on the system is interfaced at the UDC connector. A-6

Appendix A A.2.3 Cisco Transport Controller LAN Interface The UDC provides a simplex interface. Protection for UDC overhead channel(s) follows interface line protection for traffic. The UDC can be enabled or disabled through the management interfaces. The default state is disabled. The physical interface is defined in ITU-T G.703 as a 120-ohm, twisted pair connection. The jitter specification is defined in ITU-T G.823. The UDC supports a serial port interface adaptation function to overhead bytes F1. This is an EIA/TIA-232 interface capable of 9.6-, 19.2-, 38.4-, and 56-kbps operation. The rate is selectable through the management interface. The default is 56 kbps with no parity and 1 stop bit. Connector J3: UDC A.2.3 Cisco Transport Controller LAN Interface The ONS 15310-MA CTC LAN interface has the following specifications: 10/100BaseT CTX2500 access: RJ-45 connector Connector J3: LAN port A.2.4 TL1 Craft Interface The ONS 15310-MA TL1 craft interface has the following specifications: Speed: 9600 baud, no parity, 1 stop bit CTX2500: EIA/TIA-232 with RJ-45 type connector Connector J2: Craft port A.2.5 Configurations The ONS 15310-MA supports the following configurations: Two-fiber path protection 1+1 protection Path protected mesh network (PPMN) Add/drop multiplexer (ADM) Point-to-point (PPP) terminal mode A.2.6 LEDs Table A-1 describes the system-level LEDs, located on the on the ONS 15310-MA fan tray, and the possible LED colors and their significance. A-7

A.2.7 Push Buttons Appendix A Table A-2 LED FAIL CR MJ MN REM PWR A PWR B LED Description Color and Meaning Red indicates system failure or during initialization Red indicates a critical alarm is present on the shelf assembly. Red indicates a major alarm is present on the shelf assembly. Amber indicates a minor alarm is present on the shelf assembly. Red indicates a remote alarm is present on the shelf assembly. Green indicates that a DC power source present and within normal operating range. Red indicates that DC power source is not present, or is present and not within normal operating range. A.2.7 Push Buttons The ONS 15310-MA has the following push buttons: Lamp test: When momentarily pushed, lights all LEDs on the ONS 15310-MA front panel. If an LED has more than one color, all the colors will be cycled when the lamp test button is pushed. Note Another use for the lamp test button is to reset the CTC password to its default value (otbu+1). To reset the password, press the lamp test button for at least five seconds, release it for a maximum of five seconds, then press it again for at least five seconds. After the button is released, the default password is set. A.2.8 BITS Interface The ONS 15310-MA has the following building integrated timing supply (BITS) specifications: Supports two BITS inputs and two BITS outputs The BITS I/O ports support a 100-ohm termination for external 1.544 Mbps DS1 timing signals. Connector J4: BITS1; Connector J5: BITS2 A.2.9 System Timing The ONS 15310-MA has the following timing specifications: +/ 20 ppm SONET Minimum Clock (ST3) free-running internal clock Maintains SMC holdover (+/ 4.6 ppm for first 24 hours) in the event of reference frequency loss Timing reference: External BITS, line optical port, any DS-1 clock, and internal clock A.2.10 Power The ONS 15310-MA has the following power specifications: A-8

Appendix A A.2.11 Environmental Input power: 48 VDC Maximum power consumption Chassis with no cards installed (fan tray only): 55 W Chassis with cards installed: 347 W Power requirements: 44 to 54 VDC Power terminals: Three-prong male locking connector Note An ONS 15310-MA that uses DC power is classified as DC-I (DC Isolated). This means that the DC return (RET) conductor at the DC power input connector is not bonded to the chassis frame ground. A.2.11 Environmental The ONS 15310-MA has the following environmental specifications: Operating temperature: 40 to +65 degrees Celsius ( 40 to +149 degrees Fahrenheit) Operating humidity: 5 to 95 percent, noncondensing A.2.12 Fan-Tray Assembly Environmental Operating temperature: -40 to +65 degrees Celsius (-40 to 149 degrees Fahrenheit) Operating humidity: 5 to 90%, noncondensing Power 50 W, 4.2 Amps (at 12 V), 170 BTU/hr Shelf Acoustics (NEBS acoustic noise compliant) Normal fan speed: 58 dba High fan speed: 64 dba A.2.13 Shelf Dimensions The ONS 15310-MA has the following shelf dimensions: Height: 6 Rack Units (RUs), 10.44 inches (26.51 cm) Width: 10.67 inches (27.10 cm) Depth: 12 inches (20.5 cm) without cables installed 13.7 inches (34.8 cm) with cables installed Weight: 25 lbs. (11.3 kg) maximum (line cards, fan-tray assembly, and two electrical interface assemblies (EIAs) installed) A-9

A.3 Card Appendix A A.3 Card This section provides specifications for the cards that can be installed in the 15310-CL expansion slot, including the CE-100T-8, ML-100T-8, and Filler cards. It also includes the 15310-MA electrical and CTX2500 cards. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document. A.3.1 CTX2500 Card The CTX2500 card is installed in Slots 3 and 4 of the ONS 15310-MA only. The CTX2500 has the following specifications. LAN Port Supports a 10/100-Mbps Ethernet interface for Cisco Transport Controller/Transaction Language One (CTC/TL1) provisioning. For node access in secure mode, SSL (for TL1) and HTTPS (for CTC) security protocols are supported. CRAFT Port An EIA/TIA-232 craft interface is provided and is used for TL1 provisioning. The craft interface is set to 9600 baud, no parity, and 1 stop bit by default. Nonvolatile memory 128 MB, Compact Flash card Optical ports: Line Bit rate: OC-3 (155.520 Mbps), OC-12, (622.080 Mbps), and OC-48 (2488.320 Mbps), depending on the SFP installed Note Both optical interfaces on the card can be configured as OC-3, OC-12, or OC-48. Code: Scrambled NRZ Fiber: depends on the SFP used (see the A.4 SFP section on page A-15) Loopback modes: Terminal and facility Connectors: LC duplex connector for each SFP Compliance: Telcordia SONET, Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 Optical ports: Transmitter Maximum transmitter output power: Depends on the SFP used (see the A.4 SFP section on page A-15) Minimum transmitter output power: Depends on the SFP used (see the A.4 SFP section on page A-15) Center wavelength: See wavelength plan Center wavelength accuracy: 1 nm to 4 nm, depending on the SFP used Transmitter: DFB laser A-10

Appendix A A.3.2 Nonvolatile Memory Optical ports: Receiver Maximum receiver level: Depends on the SFP used (see the A.4 SFP section on page A-15) Minimum receiver level: Depends on the SFP used (see the A.4 SFP section on page A-15) Receiver: PIN PD Receiver input wavelength range: Depends on the SFP used Environmental Operating temperature: C-Temp: +23 to +131 degrees Fahrenheit ( 5 to +55 degrees Celsius) I-Temp: 40 to +149 degrees Fahrenheit ( 40 to +65 degrees Celsius) Operating humidity: 5 to 95 percent, noncondensing Power consumption: 9.28 W, 0.19 A, 31.68 BTU/hr Dimensions Height: 6.94 in. (167.28 mm) Width: 1.45 in. (36.83 mm) Depth: 8.35 in. (212.09 mm) Weight not including clam shell: 1.6 lb (0.73 kg) LAN Port Supports a 10/100-Mbps Ethernet interface for Cisco Transport Controller/Transaction Language One (CTC/TL1) provisioning. CRAFT Port An EIA/TIA-232 craft interface is provided and is used for TL1 provisioning. The craft interface is set to 9600 baud, no parity, and 1 stop bit by default. A.3.2 Nonvolatile Memory The ONS 15310-MA nonvolatile memory has a 128 MB Compact Flash card A.3.3 CE-100T-8 and ML-100T-8 Cards The CE-100T-8 and ML-100T-8 cards have the following specifications: Environmental Operating temperature C-Temp: 0 to +55 degrees Celsius (32 to 131 degrees Fahrenheit) Operating humidity: 5 to 95%, noncondensing Power consumption: 1.10A, 53 W Dimensions Height: 176 mm (6.93 in.) A-11

A.3.4 DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards Appendix A Width: 34.29 mm (1.35 in.) Depth: 238.25 mm (9.38 in.) Weight (not including clam shell): 0.499 kg (1.1 lb) A.3.4 DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards The ONS 15310-MA DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 cards have the following specifications: For DS1: For DS1: Input Bit rate: 1.544 Mbps +/- 32 ppm Frame format: Unframed, SF (D4), ESF Line code: AMI, B8ZS Termination: AMP Champ Input impedance: 100 ohms Cable loss: Max 655 feet ABAM #22 or #24 AWG AIS: TR-TSY-000191 compliant Output Bit rate: 1.544 Mbps +/- 32 ppm Frame format: Unframed, SF (D4), ESF Line code: AMI, B8ZS Termination: AMP Champ Input impedance: 100 ohms Cable loss: Max 655 feet ABAM #22 or #24 AWG AIS: TR-TSY-000191 compliant Power level: 12.5 to 17.9 dbm, centered at 772 KHz, 16.4 to 11.1 dbm centered at 1544 KHz Pulse shape: Telcordia GR-499-CORE Figure 9-5 Pulse amplitude: 2.4 to 3.6 V peak-to-peak Loopback modes: Terminal and facility Line build out: 0-131 ft., 132-262 ft., 263-393 ft., 394-524 ft., 525-655 ft. Electrical interface: 64-pin Champ connectors on high-density EIA For DS3: Input Bit rate: 44.736 Mbps +/- 20 ppm Frame format: Unframed, M13, C-bit Line code: B3ZS Termination: Unbalanced coaxial cable A-12

Appendix A A.3.4 DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards Input impedance: 75 ohms +/-5 percent Cable loss: Max 450 feet with 734A or 728A AIS: TR-TSY-000191 compliant Output Bit rate: 44.736 Mbps +/- 20 ppm Frame format: Unframed, M13, C-bit Line code: B3ZS Termination: Unbalanced coaxial cable Input impedance: 75 ohms +/-5 percent Cable loss: Max 450 feet with 734A or 728A cable AIS: TR-TSY-000191 compliant Power level: -1.8 to +5.7 dbm Pulse shape: ANSI T1.102-1988 Figure 8 Pulse amplitude: 0.36 to 0.85 V peak Loopback modes: Terminal and facility Line build out: 0 to 225 feet, 226 to 450 feet Electrical interface: BNC Connectors on high-density EIA For EC-1: Input Bit rate: 51.84 Mbps +/- 20 ppm Frame format: SONET Line code: B3ZS Termination: Unbalanced coaxial cable Input impedance: 75 ohms +/- 5 percent Cable loss: Max 450 feet 734A or 728A AIS: TR-TSY-000191 compliant Output Bit rate: 51.84 Mbps +/- 20 ppm Frame format: SONET Line code: B3ZS Termination: Unbalanced coaxial cable Input impedance: 75 ohms +/-5 percent Cable loss: Max 450 feet 734A or 728A AIS: TR-TSY-000191 compliant Power level: -1.8 +/- 5.7 dbm Pulse shape: ANSI T1.102-1988 Figure 8 Pulse amplitude: 0.36 to 0.85 V peak to peak Loopback modes: Terminal and facility A-13

A.3.5 Filler Cards Appendix A Line build out: 0 to 225 feet, 226 to 450 feet Electrical interface: BNC connectors on high-density EIA Surge protection: Telcordia GR-1089 Operating temperature: I-Temp, -40 to +65 degrees Celsius. Operating humidity: 5 to 95 percent, noncondensing Power consumption: 36.60 W, 0.76 A, 124.97 BTU/hr Dimensions Height: 6.93 in. (17.60 cm) Width: 1.35 in. (3.43 cm) Depth: 8.80 in. (22.35 cm) Card weight: 1.5 lbs (0.68 kg) A.3.5 Filler Cards The 15310-EXP-FILLER card has the following specifications: Environmental Operating temperature I-Temp: 40 to +65 degrees Celsius ( 40 to 149 degrees Fahrenheit) Operating humidity: 5 to 95 percent, noncondensing Dimensions Height: 6.93 in. (176 mm) Width:1.35 in. (34.29 mm) Depth: 9.38 in. (238.25 mm) Card weight (not including clam shell): 0.9 lb (0.45 kg) The 15310-CTX-FILLER card has the following specifications: Environmental Operating temperature I-Temp: -40 to +65 degrees Celsius (-40 to 149 degrees Fahrenheit) Operating humidity: 5 to 95%, noncondensing Dimensions Height: 6.94 in. (167.28 mm) Width: 1.450 in. (36.83 mm) Depth:8.35 in. (212.09 mm) Weight not including clam shell: 0.51 lb (0.23 kg) A-14

Appendix A A.4 SFP A.4 SFP Table A-3 lists specifications for available SFPs that can be used with the 15310-CL-CTX and CTX2500 cards. Table A-4 lists specifications for available SFPs that can be used only with the CTX2500 card. The 15310-CL-CTX card does not have a faceplate because it is located inside the chassis; therefore, the two SFP slots are located on the ONS 15310-CL faceplate, just to the left of the LAN port. The two SFP slots on the CTX2500 are located on CTX2500 faceplate. Table A-3 SFP ONS 15310-CL and ONS 15310-MA SFP Product ID Interface Transmitter Output Power Min/Max (dbm) Receiver Input Power Min/Max (dbm) ONS-SI-155-L1 OC-3 5.0 to 0 34 to 10 ONS-SI-155-L2 OC-3 5.0 to 0 34 to 10 ONS-SI-155-I1 OC-3 15 to 8.0 28 to 8 ONS-SI-622-L1 OC-12 3.0 to 2.0 28 to 8 ONS-SI-622-L2 OC-12 3.0 to 2.0 28 to 8 ONS-SI-622-I1 OC-12/OC-3 15 to 8.0 28 to 8 Table A-4 SFP ONS 15310-MA Only SFP Product ID Interface Transmitter Output Power Min/Max (dbm) Receiver Input Power Min/Max (dbm) ONS-SE-155-1470= through OC-3 0 to +5 34 to 3 (at BER 10-10 ) ONS-SE-155-1610= ONS-SE-622-1470= through OC-12 0 to +5 28 to 3 (at BER 10-10 ) ONS-SE-622-1610= ONS-SI-2G-I1= OC-48 5.0 to 0 18 to 0 ONS-SI-2G-L1= OC-48 3 to +2 27 to 9 ONS-SI-2G-L2= OC-48 3 to +2 28 to 9 ONS-SI-2G-S1= OC-48 10 to -3 18 to 3 ONS-SC-2G-30.3= through ONS-SC-2G-60.6= OC-48 0 to +4 28 to 9 Table A-5 provides cabling specifications for the single-mode fiber (SMF) SFPs that can be used with both the 15310-CL-CTX and the ONS 15310-MA CTX2500. The ports of the listed SFPs have LC-type connectors. Table A-6 provides cabling specifications for SFPs that can only be used with the ONS 15310-MA CTX-2500 card. Table A-5 Single-Mode Fiber SFP Port Cabling ONS 15310-CL and ONS 15310-MA SFP Product ID Wavelength 1 Fiber Type Cable Distance ONS-SI-155-L1 Long Reach 1310 nm 9 micro SMF 50 km (31.07 miles) ONS-SI-155-L2 Long Reach 1550 nm 9 micro SMF 100 km (62.15 miles) A-15

A.4 SFP Appendix A Table A-5 Single-Mode Fiber SFP Port Cabling ONS 15310-CL and ONS 15310-MA (continued) SFP Product ID Wavelength 1 Fiber Type Cable Distance ONS-SI-155-I1 Intermediate Reach 1310 nm 9 micro SMF 21 km (13.05 miles) ONS-SI-622-L1 Long Reach 1310 nm 9 micron SMF 42 km (26.10 miles) ONS-SI-622-L2 Long Reach 1550 nm 9 micron SMF 85 km (52.82 miles) ONS-SI-622-I1 Intermediate Reach 1310 nm 9 micron SMF 21 km (13.05 miles) 1. Typical loss on a 1310-nm wavelength SMF is 0.6 db/km. Table A-6 Single-Mode Fiber SFP Port Cabling ONS 15310-MA Only SFP Product ID Wavelength 1 ONS-SE-155-1470 through ONS-SE-155-1610 (CWDM) ONS-SE-622-1470 through ONS-SE-622-1610 (CWDM) 1470 nm through 1610 nm, according to the wavelength indicated in the SFP s product ID 1470 nm through 1610 nm, according to the wavelength indicated in the SFP s product ID 1. Typical loss on a 1310-nm wavelength SMF is 0.6 db/km. Fiber Type Cable Distance 9 micron SMF 120 km (74.56 miles) 9 micron SMF 100 km (62.14 miles) ONS-SI-2G-I1 1310 nm 9 micron SMF 15 km (9.3 miles) ONS-SI-2G-L1 1310 nm 9 micron SMF 40 km (25.80 miles) ONS-SI-2G-L2 1550 nm 9 micron SMF 80 km (49.71 miles) ONS-SI-2G-S1 1310 nm 9 micron SMF 2 km (1.2 miles) ONS-SC-2G-30.3 through ONS-SC-2G-60.6 (DWDM) 1530.30 nm through 1560.60 nm, according to the wavelength indicated in the SFP s product ID Note When using ONS-SC-2G-xx.x on CTX-2500 the Cisco ONS 15310 -MA operating temperature specification is limited to 5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit). 9 micron SMF N/A 2 2. ONS-SC-2G-xx.x cable distance varies depending on DWDM system installation. A-16