MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

Similar documents
To connect the AC adapter:

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Dell OptiPlex All-in-One. Stand Installation Guide

Dell Inspiron N5110 Service Manual

Removing and Replacing Parts

Replacement Instructions. Backplane PCA for the HP Router 650

Dell Inspiron XPS and Inspiron 9100 Service Manual

Replacing the Power Supply

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Oracle <Insert Picture Here>

Installing and Upgrading Memory and Virtual Private Network Modules

Replacing Preamplifier Circuit Boards

Dell XPS L702X Service Manual

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Pro-Flo System Digital Controller EPROM Upgrade

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Power Supply, 17-inch

Dell XPS 14z Owner s Manual

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Replacement Keyswitch Assembly

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Installation Instructions

Replacement Instructions

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Gateway Profile 4 service guide

Dell Latitude C800 Service Manual

Series 3700 Screw Terminal Assemblies Installation Instructions

JDM Installation Guide

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Replacing the Gateway M275 Keyboard

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

120Ra-1 Pentium III Processor Installation Insert

Replacing the Gateway 200ARC Keyboard

Managing Individual Components

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Installation Job Aid for Ethernet Routing Switch 5900 Series

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015

TRC-190 User s Manual

Customer Upgrade Procedure

Controller PC Hard Drive

Upgrading and Servicing Guide

PC9/P9 CPU Card Replacement

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Installing a New Solo 1150 Hard Drive

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

Customer Replacement Procedure

SGI InfiniteStorage 120

HP EVA4400 M6412 drive enclosure

Field Service Guide Supplement for the NS 7000/030

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Chapter 2. Installing the Chapter 2. Contents

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

TDM To MiniMech conversion ProceDure

Dell Inspiron Optical-Drive Connector

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

Installing the upgrade memory kit in the G450 and G430 Media Gateway

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Installation Data. The 1771 OB module can control the following output devices: dc motor starters indicators solenoids

Memory (RAM) Replacement Instructions. apple PowerBook (FireWire) Tools Required. Electrostatic Discharge (ESD)

Dell Latitude C800 SERVICE MANUAL. support.dell.com

Intel NUC Kit NUC6CAYS User Guide

Replacing the Hardware Configuration Option EPROM on the 1822

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Dell XPS M1530 Service Manual

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

Dell Precision 3430 Small Form Factor

Installing the Cisco SFS 3504 Server Switch

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

*E * E E0606

Adding or Replacing a PCI Card

Job Aid: Replacing the Field Replaceable Units (FRUs) for the Avaya G430 Media Gateway

Upgrading LVDS Cables Instruction Sheet

Installing and Removing SDRAM and DRAM

Replacement Instructions

TRC-190 User s Manual

Dell Inspiron System Board

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

Replacing the Gateway M305 Optical Drive

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Upgrading and Servicing Guide

How to Upgrade the Hard Drive in a 24 imac (2007-Early 2009)

Replacing a 3.5-inch disk drive

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

PC9/P9 Floppy Drive Replacement

XTM 1050 Replacement Parts Installation

Replacing the Gateway M405 Keyboard

Maintaining the Cisco Internet Router

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Upgrading and Servicing Guide

Removing and Replacing Chassis Components

Precision 3930 Rack. Zoom card Installation Guide. Regulatory Model: D24M Regulatory Type: D24M003

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

Customer Replacement Procedure

Dell Latitude V710/V740 Service Manual

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Transcription:

Page 1 of 16 MODULUS 21 Power Distribution Unit (PDU) Replacement Overview Introduction This notice explains how to replace the AC Power Distribution Unit (PDU), also known as a Power Distribution Assembly (PDA), in a Modulus 21 enclosure. This notice assumes familiarity with Modulus 21-mounted products and the Modulus 21 itself. Your conþguration may vary from the examples shown here. Additional Information For details, refer to your device documentation, and to the Modulus 9 and 21 Installation and Operation Guide (Part No. 09564). In This Manual Topic See Page Modulus 21 Enclosure Overview... 3 Removing Product Cards from a Modulus 21... 4 Removing Power Supply Modules from a Modulus 21... 6 Removing a Modulus 21 Enclosure From a Rack... 7 Removing Backplane(s) and the PDU from a Modulus 21... 8 Replacing a PDU and Backplane(s) in a Modulus 21... 10 Replacing a Modulus 21 in a Rack... 11 Checking Modulus 21 Resistance... 12 Re-installing Power Supply Modules in a Modulus 21... 13 Checking Modulus 21 Voltage... 14 Re-installing Product Cards in a Modulus 21... 15 Returning a PDU to Motorola ISG... 16 PDU Kit Contents The PDU replacement kit includes: PDU hardware PDU replacement label This document If your kit is incomplete, contact Motorola ISG Customer Support. 09564-2 A

Overview Page 2 of 16 Modulus 21 Serial Numbers Affected This notice refers only to replacing PDUÕs in Modulus 21Õs whose serial number is one of the following. (For serial-number label location, refer to Figure 5, L.) 3494 5043 285000-330000 (range) 549998-600000 890000-893000 915000-999999 2026000-9000000 9400000-32220000 6009568007 10052388-8 890000A - 999999A 890000B - 999999B 890000D - 999999D 3150000A - 3300000A 3100000B - 3300000B 3100000R - 3300000R 890100DM - 890200DM Warning! Only qualified Service personnel should perform this procedure. Use of the procedure by unqualiþed personnel could result in personal injury or equipment damage, which could jeopardize your warranty and maintenance agreement. Tools Needed The following tools and supplies are required: Grounding wrist strap Labels Flat- and Phillips- head screwdrivers Anti-static plastic bags Multi-meter

Page 3 of 16 Modulus 21 Enclosure Overview Overview This section explains how Motorola products are contained in Modulus 21 enclosures (Figure 1) and equipment racks. Rack Front Door (Product Cards Within) Rack Mount Bracket Front Door Hinge Pin Locations Front Back Front Door Latch Location Figure 1. Modulus 21 Enclosure Product Cards Enclosures Backplanes Equipment Racks A Modulus 21 enclosure provides common housing and power for plug-in card versions of Motorola products, such as 35XX DSU/CSUs, 326X dial modems, 33XX leased-line modems, and 6500 nodes. The Modulus 21 enclosure accommodates product cards in its 21 slots. It can hold two or three independent power supply modules, and one power distribution unit (PDU). The Modulus 21 can contain one or more product-speciþc backplanes to carry the signal and data ßow between product cards and the external environment, and to provide cable connections to product cards. A standard 19-inch equipment rack can hold Modulus 21Õs and other units.

Page 4 of 16 Removing Product Cards from a Modulus 21 Overview This section explains how to remove product cards from a Modulus 21 enclosure. Card Removal Remove product cards and Þller panels from the Modulus 21 enclosure as follows. IMPORTANT This procedure removes power from all devices in the Modulus 21. Before you begin, plan for the effects on your network functions and users. Warning! Before you begin, unplug the AC power cord from the power source. Removing Product Cards from a Modulus 21 Enclosure 1 Attach a grounding wrist strap to yourself and a grounded object. 2 Unplug both ends of the AC power cable (Figure 2, A) from the PDU. 3 Open the Modulus 21 front door. From the front and back of the Modulus 21, label each product card and cable connector. Label each backplaneõs location. 4 Detach the cable connectors from the backplane(s) (Figure 5, B). 5 Remove a product card (Figure 3, A) by pressing its top and bottom clips apart and pulling it from the slot. Put the card in an anti-static bag. Repeat for each product card. Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. Card, cable, and backplane locations and connections are labelled. Cables are disconnected. Cards are removed from Modulus 21. Cards are protected from damage.

Removing Product Cards from a Modulus 21 Page 5 of 16 (PDU Within) Modulus 21 (Back) AC Power Connector on PDU C Sheetmetal Retainers A AC Power cable is Removed from PDU B Modulus 21 Sheetmetal Figure 2. Unplugging AC Power Cord from Back of Modulus 21 Modulus 21 (Front) A Product Card Unlock Lock Card top clips Slide Card Out of Slot Slide Card Into Slot Unlock Card Bottom Clips Lock B Front Filler Panel Figure 3. Removing/Installing Product Cards in Modulus 21 Slots

Page 6 of 16 Removing Power Supply Modules from a Modulus 21 Overview This section explains how to remove a power supply module from a Modulus 21. Removing a Power Supply Module From a Modulus 21 1 Ensure that you are wearing a grounding wrist strap and that the AC power cable is disconnected from the PDU (Figure 5, A). 2 With the Modulus 21 front door open, squeeze the two front door hinge pins (Figure 1) toward each other until the pins are free. Remove the front door. 3 Insert a ßat-blade screwdriver into each of a power supplyõs two locking tabs (Figure 4, A). Gently turn the screwdriver until the tab clicks. Pull the power supply module (Figure 4, B) from the Modulus 21. 4 Repeat for each power supply module. Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. Modulus 21 front door is removed. Power supply modules are removed from the Modulus 21. Modulus 21 (Front) B Power Supply Modules A Locking Tab Locations Figure 4. Removing Power Supply Modules From Modulus 21

Page 7 of 16 Removing a Modulus 21 Enclosure From a Rack This section explains how to remove the Modulus 21 enclosure from a rack. Warning! The Modulus 21 enclosure is heavy. To avoid injury, two people should remove it. Removing a Modulus 21 Enclosure from a Rack 1 Ensure that the AC power cable is disconnected from the PDU (Figure 5, A). 2 Position one person in front of the Modulus 21 and one at the back. 3 Hold the Modulus 21 in place in the rack while removing the rack mount bracket screws (Figure 1). 4 Carefully slide the Modulus 21 out of the front of the rack. Power is removed from the Modulus 21 and the devices in it. Modulus 21 is removed from rack.

Page 8 of 16 Removing Backplane(s) and the PDU from a Modulus 21 This section explains how to remove backplanes and the PDU from a Modulus 21. Removing Product Backplanes and the PDU From a Modulus 21 Enclosure 1 Ensure that you are wearing a grounding wrist strap and that the AC power cable is disconnected from the PDU (Figure 5, A). 2 From the back of the Modulus 21, loosen a backplaneõs top and bottom screws (Figure 5, B). Push the backplane vertically, very slightly, to disconnect it from the power distribution connector (Figure 5, C). Tilt the top of the backplane away from the Modulus 21 (Figure 5, D), and remove it. Put the backplane in an anti-static bag. Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. 3 Repeat for each backplane. Backplanes are removed from the enclosure. 4 Remove any back Þller panels from unused slots. 5 From the back of the Modulus 21, remove the sheetmetal screws (Figure 5, E); there are six of one size and two of another. Remove the sheetmetal. 6 Press forward on each of the four PDU locking tabs (Figure 5, F) to unlock them. Pull the PDU (Figure 5, G) out. Set it aside for return to Motorola ISG, as described in a later section. Sheetmetal is removed from the Modulus 21. PDU is removed from the Modulus 21.

Removing Backplane(s) and the PDU from a Modulus 21 Page 9 of 16 B Backplane G PDU D Modulus 21 Enclosure (Back) I Test Connectors E Sheetmetal Screw J Sheetmetal L Modulus 21 Serial- Number Label H Slots F PDU Locking Tabs A AC Power is removed from PDU AC Power connector aperture K PDU Upgrade Label Avoid Bending These Male Pins C Power Distribution Connector Figure 5. Removing Backplane(s) and PDU from a Modulus 21

Page 10 of 16 Replacing a PDU and Backplane(s) in a Modulus 21 This section explains how to install a PDU and backplane(s) in a Modulus 21. Replacing a Power Distribution Unit (PDU) and Backplane(s) in a Modulus 21 PDU p/n: 65524 G01 Artwork Rev: B Assembly Rev: C 1 Ensure that you are wearing a grounding wrist strap and that the AC power cable (Figure 5, A) is disconnected from the PDU. 2 From the back of the Modulus 21, slide the PDU (Figure 5, G) into its slots, then press down on it, so that all four locking tabs (Figure 5, F) lock. 3 Slide the sheetmetal into place while pressing its two retainers (Figure 2, C) with your thumbs. Install the sheetmetal screws (Figure 5, E); there are six of one size and two of another. Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. PDU is installed in the Modulus 21. Sheetmetal is installed in the Modulus 21. 4 Re-install a backplane by pressing it down and into the power distribution connectors (Figure 5, C). Ensure that the backplane is seated Þrmly in the connectors. 5 Repeat for each backplane. Backplanes are re-installed in the Modulus 21. 6 Replace any back Þller panels in unused slots (Figure 5, H). 7 Tighten all backplane screws. 8 Attach the PDU upgrade label (Figure 5, K) to the Modulus 21 sheetmetal (Figure 5, J). Modulus 21 is labelled to conþrm PDU upgrade.

Page 11 of 16 Replacing a Modulus 21 in a Rack This section explains how to install a Modulus 21 in a rack. Warning! The Modulus 21 enclosure is heavy. To avoid injury, two people should install it. Installing a Modulus 21 Enclosure in a Rack 1 Position one person in front of the Modulus 21 and one at the back. 2 Carefully slide the Modulus 21 into the front of the rack. 3 Hold the Modulus 21 in place in the rack while installing the screws in the rack mount brackets (Figure 1). Modulus 21 enclosure is installed in the rack.

Page 12 of 16 Checking Modulus 21 Resistance Overview This section explains how to check the Modulus 21 electrical resistance. Checking Modulus 21 Resistance 1 2 3 4 5 6 1 Ensure that you are wearing a grounding wrist strap and that the AC power cable is disconnected from the PDU (Figure 5, A). 2 Set a multi-meter to a minimum 20-W range. On the PDU, measure the resistance between pairs of test connector pins (Figure 5, I). Readings should be W, as shown in Table 2. Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. If any pair registers resistance, the backplane connectors are short-circuited. Remove the product backplane (as explained above), and carefully straighten any bent pins on the PDU. If a pair still registers resistance, repeat the entire PDU replacement procedure. If you cannot resolve the problem, contact Motorola Customer Support. If all pairs register as open circuits, the backplane circuits are OK. Table 1. Resistance Check Pin Connections Measure From This Pin... To This Pin... To Obtain Number Description Number Description This Reading: 1 Ground 4 +5V W 1 Ground 5 +12V W 1 Ground 6-12V W 4 +5V 5 +12V W 4 +5V 6-12V W 5 +12V 6-12V W

Page 13 of 16 Re-installing Power Supply Modules in a Modulus 21 Overview This section explains how to re-install a power supply module in a Modulus 21. Installing Power Supply Modules in a Modulus 21 Enclosure 1 Ensure that you are wearing a grounding wrist strap and that the AC power cable is disconnected from the PDU (Figure 5, A). 2 Carefully slide a power supply module (Figure 4, B) into the front of the Modulus 21. 3 Repeat for each power supply module. Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. The tabs lock in place (Figure 4, A). Power supply modules are replaced in the Modulus 21.

Page 14 of 16 Checking Modulus 21 Voltage Overview This section explains how to check the Modulus 21 electrical voltage. Checking Modulus 21 Voltage 1 2 3 4 5 6 1 Ensure that you are wearing a grounding wrist strap. 2 Connect the AC power cable to the PDU (Figure 5, A). 3 Set a multi-meter to a DC voltage setting. On the PDU, measure the voltage between pairs of connector pins (Figure 5, I). Voltages should match those in Table 2. Any electrostatic energy is discharged from you. Power is supplied to the Modulus 21 and the devices in it. If any voltage reading is incorrect, immediately disconnect the AC power cord. Ensure that the power supplies are seated correctly, remove the backplane(s) as explained above, and carefully straighten any bent pins. Repeat Step 3. If you cannot resolve the problem, contact Motorola Customer Support. If all voltages are correct, the PDU is installed correctly. Table 2. Voltage Check Pin Connections Measure From This Pin... To This Pin... To Obtain Number Description Number Description This Reading: 1 Ground 4 +5V +5V 1 Ground 5 +12V +12V 1 Ground 6-12V -12V

Page 15 of 16 Re-installing Product Cards in a Modulus 21 Caution! Before you begin, unplug the AC power cable from the power source. Card Installation Re-install product cards and Þller panels in the Modulus 21 enclosure as follows. Installing Product Cards in a Modulus 21 Enclosure 1 2 3 4 5 6 1 Ensure that you are wearing a grounding wrist strap. 2 Disconnect the AC power cable from the Modulus 21 (Figure 2). 3 From the front of the Modulus 21, slide a product card into its labelled slot and seat it in its top and bottom clips (Figure 3). Any electrostatic energy is discharged from you. Power is removed from the Modulus 21 and the devices in it. 4 Repeat for each product card. Product cards are re-installed in Modulus 21. 5 From the back of the Modulus 21, connect cables to backplane(s) according to their labelled locations. Cables are reconnected. 6 Plug the AC power cable into the Modulus 21. 7 Set a multi-meter to a DC voltage setting. On the PDU, measure the voltage between pairs of connector pins (Figure 5, I). Voltages should match those in Table 2. Power is supplied to the Modulus 21 and the devices connected to it. If any voltage reading is incorrect, immediately disconnect the AC power cord. Ensure that the power supplies are seated correctly, remove the backplane(s) as explained above, and carefully straighten any bent pins. Repeat Step 3. If you cannot resolve the problem, contact Motorola Customer Support. If all voltages are correct, the product cards are installed correctly.

Page 16 of 16 Returning a PDU to Motorola ISG This section explains how to prepare a PDU for return to Motorola ISG. Returning a PDU to Motorola ISG 1 Attach the following information to the PDU: RMA # 062095000 Subsidiary name and location Modulus 21 serial number Customer name 2 Put the PDU in a poly bag and carefully pack it in the package that the new PDU came in. 3 Mark the Equipment Return Authorization (ERA) number on the outside of the package. The ERA is on the replacement-pdu order acknowledgment. 4 If you are in the U. S. A., ship the PDU to: Modulus Project Motorola ISG 11-A Norfolk Street MansÞeld, MA 02048 USA Attn.: Roy Savill If you are outside the U. S. A., ship the PDU to: Modulus Project Motorola ISG Church Road LowÞeld Heath Crawley, West Sussex RH11 OPQ, Great Britain Motorola ISG recommends that you use a delivery company that offers proof-of-delivery. Return multiple PDUÕs in batches, one per month. PDU is identiþed for proper credit to your account. The PDU replacement procedure is complete.