PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Similar documents
IBS IL 24 BK RB-T-2MBD

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

IBS IL 24 RB-LK-2MBD:

IB IL 24 DI 16 IB IL 24 DI 16-PAC

This data sheet is only valid in association with the IL SYS INST UM E user manual.

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILC 200 IB ILC 200 IB-PAC

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

IBS ST (ZF) 24 BK LB-T

IB IL 24/48 DOR 2/W-XC-PAC

IB IL AO 2/SF... Inline terminal with two analog outputs. AUTOMATION Data sheet 6655_en_06. 1 Description

PHOENIX CONTACT - 10/2006

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 07/2005

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

IB IL IB IL PAC

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

VersaPoint I/O Module

Rexroth Inline terminal with one analog output

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 11/2008

PHOENIX CONTACT - 07/2006

IB IL RS 232 IB IL RS 232-PAC

PHOENIX CONTACT - 10/2009

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

AXL E IOL AO1 U M12 R

PI-EX-ME-2NAM/COC-24VDC

GFK-2415A March Type of sensor connection

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

PB IL 24 BK DIO 16/16

VersaMax IP I/O Module

PLC-OSC-120UC/ 24DC/ 2

MINI-PS AC/10-15DC/8

ASI QUINT /2.4 EFD

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

FL MC 2000E (SM40) LC

MINI MCR-SL-UI-2I(-SP)(-NC)

PLC-OPT- 24DC/230AC/1

PSI-MODEM-SHDSL/SERIAL

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Automation terminals of the Inline product range. User manual

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PHOENIX CONTACT Features

PLC-OPT-230UC/ 24DC/2

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

onlinecomponents.com

PLC-OSC- 24DC/ 48DC/100

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

TRIO-DIODE/12-24DC/2X10/1X20

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

PHOENIX CONTACT

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.:

PLC-RSC- 24DC/21 Order No.:

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

STEP-PS/1AC/24DC/1.75

MINI MCR-SL-CVS NC

IL CAN BK-TC-XC-PAC. Inline CANopen bus coupler Extreme conditions version. Data sheet _en_01. 1 Description

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

8 24 V DC, 8 24 V DC,

QUINT-PS/ 1AC/24DC/ 5

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT - 01/2007

PLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-PT100-UI(-SP)(-NC)

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

Extract from the online catalog

VersaMax IP Input Module

Extract from the online catalog

QUINT-PS-3x AC/24DC/10

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI MCR-SL-PT100-UI-200

PHOENIX CONTACT - 01/2008

ETD-BL-1T-OFF-CC- 10S

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

SUBCON-PLUS-PROFIB...

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

QUINT-BUFFER/24DC/24DC/40

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PLC-RSC- 24DC/ Extract from the online catalog. Order No.:

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Transcription:

INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler connects an Inline station to the INTERBUS remote bus. It provides the supply voltages U L and U ANA for the connected devices. Features Remote bus connections using copper cables via D-SUB connectors Electrical isolation to the remote bus segments Automatic configuration of the outgoing interface as remote bus or local bus interface Support of up to 15 connected terminals with remote bus branch When using a terminal with remote bus branch (IBS IL 24 RB-T...), please refer to page 14. Please note that the power terminal is not supplied with the bus coupler. To order this terminal, please refer to the "Ordering Data" on page 2 or to the latest "AUTOMATION" catalog. The end plate is supplied with the bus coupler. Place this plate at the end of the Inline station. The termination plate has no electrical function. It protects the station from ESD pulses and the user from dangerous voltage. A power terminal must be connected after the bus coupler to supply the main and segment voltage to the subsequent terminals. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for the products listed on the following page:

Ordering Data Products Description Type Order No. Pcs./Pck. INTERBUS bus coupler with D-SUB connection, without accessories; 500 kbps transmission speed INTERBUS bus coupler with D-SUB connection, with accessories (connector and labeling field); 500 kbps transmission speed INTERBUS bus coupler with D-SUB connection, without accessories; 2 Mbps transmission speed INTERBUS bus coupler with D-SUB connection, with accessories (connector and labeling field); 2 Mbps transmission speed IBS IL 24 BK-DSUB 2742104 1 IBS IL 24 BK-DSUB-PAC 2861593 1 IBS IL 24 BK-DSUB-2MBD 2855949 1 IBS IL 24 BK-DSUB-2MBD-PAC 2826123 1 Accessories Description Type Order No. Pcs./Pck. Two D-SUB connectors are required for connecting INTERBUS. The connectors are not supplied as standard. Bus connector, solder connection, male/female connector IBS DSUB 9/L 2758473 1 Bus connector, crimp connection, male/female connector IBS DSUB 9/C 2758486 1 A connector is required to provide the bus coupler supply for the IBS IL 24 BK-DSUB and IBS IL 24 BK-DSUB-2MBD terminals. Inline connector, with color print IB IL SCN-8-CP 2727608 10 Power Terminal, Complete With Accessories (Connector and Labeling Field), 500 kbps and 2 Mbps Transmission Speed Power terminal with fuse (U M, U S ) IB IL 24 PWR IN/2-F-PAC 2862136 1 Power terminal without fuse IB IL 24 PWR IN-PAC 2861331 1 Power terminal with fuse (U M, U S ) IB IL 24 PWR IN/F-PAC 2861438 1 Power Terminal, Complete With Accessories (Connector and Labeling Field), for 500 kbps Power terminal with fuse (U M, U S ) and diagnostics IB IL 24 PWR IN/2-F-D-PAC 2862152 1 Power terminal with fuse (U M, U S ) and diagnostics IB IL 24 PWR IN/F-D-PAC 2861894 1 Power terminal with fuse (U M, U S ) and diagnostics IB IL 24 PWR IN/2F-DF-PAC 2863779 1 Power Terminal, Complete With Accessories (Connector and Labeling Field), for 2 Mbps Power terminal with fuse (U M, U S ) and diagnostics IB IL 24 PWR IN/2F-DF-2MBD-PAC 2863834 1 Power terminal with fuse (U M, U S ) and diagnostics IB IL 24 PWR IN/2F-D-2MBD-PAC 2863821 1 Documentation Description Type Order No. Pcs./Pck. "Configuring and Installing the INTERBUS Inline Product Range" user manual IB IL SYS PRO UM E 2743048 1 6362_en_03 PHOENIX CONTACT 2

Technical Data General Data Housing dimensions (width x height x depth) 90 mm x 120 mm x 71.5 mm Weight 210 g (without connector); 225 g (with connector) Ambient temperature (operation) -25 C to +55 C Ambient temperature (storage/transport) -25 C to +85 C Permissible humidity (operation/storage/transport) 10% to 95%, according to DIN EN 61131-2 Permissible air pressure (operation/storage/transport) 70 kpa to 106 kpa (up to 3000 m above sea level) Degree of protection IP20 according to IEC 60529 Protection class Class 3 according to VDE 0106, IEC 60536 Connection data Connection type Spring-cage terminals Conductor cross-section 0.2 mm 2 to 1.5 mm 2 (solid or stranded), 24-16 AWG Interfaces (INTERBUS) Remote Bus Incoming remote bus Outgoing remote bus Recommended cable lengths Copper cable (RS-422), connected via D-SUB connector; electrically isolated supply; shielding connected with a capacitor to functional earth ground Copper cable (RS-422), connected via D-SUB connector; electrically isolated supply; shielding directly connected to functional earth ground See INTERBUS system data Functional Observe current consumption of the terminals Observe the logic current consumption of each device when configuring an Inline station. It is specified in every terminal-specific data sheet. The current consumption can differ depending on the individual terminal. The permissible number of devices that can be connected therefore depends on the specific station structure. Interface configuration (internal) If the next device is snapped on, the bus coupler automatically configures the interface. If the next device is a terminal with remote bus branch, the interface is configured as a remote bus interface. For every other device (e.g., I/O terminal) the interface is configured as a local bus interface with diagnostics. 6362_en_03 PHOENIX CONTACT 3

Bus Coupler Supply Connections See Figure 4 on page 11 Connection method Recommended cable lengths Continuation Special demands on the voltage supply Spring-cage terminals 30 m, maximum; routing cables through outdoor areas is not admissible Via potential routing The bus coupler supply U BK is electrically isolated from U M /U S if it is supplied separately. This is only ensured if two separate power supply units are used. Nominal value DC Tolerance -15%/+20% (according to EN 61131-2) Ripple ±5% Permissible range 19.2 V to 30 V Minimum current consumption at nominal voltage 0.10 A DC (At no-load operation, i.e., incoming remote bus connected, no local bus devices connected, bus inactive) Maximum current consumption at nominal voltage 1.25 A DC consisting of: 0.75 A DC for communications power 0.5 A DC for analog voltage supply Safety equipment For the bus coupler supply only Surge voltage Yes Polarity reversal Yes Provide an external fuse for the area This area must be externally protected. The power supply unit must be able to supply 4 times (400%) the nominal current of the external fuse, to ensure that the fuse blows safely in the event of an error. Module Supply Communications Power (Potential Jumpers) Nominal value 7.5 V DC Tolerance ±5% Ripple ±1.5% Maximum output current 2 A DC (observe derating) Safety equipment Electronic short-circuit protection Communications Power (Interfaces) Nominal value 2 x 5 V DC Tolerance ±5% Ripple ±1.5% Maximum output current 2 x 0.15 A DC Safety equipment None Communications Power (Internal) Nominal value 1 x 5 V DC Tolerance ±5% Ripple ±1.5% Maximum output current 1 x 0.15 A DC Safety equipment None Analog Supply (Potential Jumpers) Nominal value DC Tolerance -15%/+20% Ripple ±5% Maximum output current 0.5 A DC (observe derating) Safety equipment Electronic short-circuit protection 6362_en_03 PHOENIX CONTACT 4

Derating of the Communications Power and the Analog Terminal Supply P [%] 100 90 80 70 60 50 40 30 20 10 0 0 5 10 15 20 25 30 35 40 45 50 55 T A [ C] P [%] Current carrying capacity of the power supply unit for communications power (U L ) and analog supply (U ANA ) in % T A [ C] Ambient temperature in C Power Dissipation Formula to Calculate the Power Dissipation of the Electronics P EL = P BUS + P PERI b P = 1.6 W + (1.375 W EL x I Ln) + (0.7 W x I Lm) A n = 1 A a m = 1 6291A006 Where: P EL P BUS P PERI Total power dissipation in the terminal Power dissipation for bus operation without I/O load (permanent) Power dissipation with I/O connected I Ln Current consumption of device n from the communications power n Index of the number of connected devices (n = 1 to a) a Number of connected devices (supplied with communications power) Total current consumption of the devices from the 7.5 V communications power (2 A, maximum) a I Ln n = 1 I Lm Current consumption of the device m from the analog supply m Index of the number of connected analog devices (m = 1 to b) b Number of connected analog devices (supplied with analog voltage) Total current consumption of the devices from the analog supply (0.5 A, maximum) b I Ln m = 1 6362_en_03 PHOENIX CONTACT 5

Power Dissipation/Derating Using the maximum currents 2 A (logic current) and 0.5 A (current for analog terminals) in the formula to calculate the power dissipation when the I/O is connected results in the following: P PERI = 2.75 W + 0.35 W = 3.10 W 3.1 W correspond to 100% current carrying capacity of the power supply unit in the derating curves on page 5. Ensure that the indicated nominal current carrying capacity in the derating curves is not exceeded when the ambient temperature is above 45 C. Corresponding to the formula, the total current carrying capacity of the connected I/O (P PERI ) is relevant. If, for example, no current is drawn from the analog supply, the percentage of current coming from the communications power may be increased. Example: Ambient temperature: 55 C Nominal current carrying capacity of communications power and analog supply: 75% according to the diagram I LLogic = 1.5 A, I LAnalog = 0,375 A P PERI = 2.0625 W + 0.2625 W P PERI = 2.325 W (corresponds to 75% of 3.10 W) Possible logic current if the analog supply is not loaded: P PERI = 1.375 W/A x I LLogic + 0 W P PERI / 1.375 W/A = I LLogic I LLogic = 2.325 W / 1.375 W/A I LLogic = 1.691 A Error Messages to the Higher-Level Control or Computer System I/O error No Safety Equipment Surge voltage (bus coupler supply) Polarity reversal (bus coupler supply) Input protective diodes (can be destroyed by permanent overload) Pulse loads up to 1500 W are short circuited by the input protective diode. Serial diode in the lead path of the power supply unit; in the event of an error only a low current flows. In the event of an error, no fuse trips within the external power supply unit. If you want to protect the bus coupler supply U Bk, use a 2 A medium blow fuse. Electrical Isolation/Isolation of the Voltage Areas Please note that the bus coupler supply U BK must be supplied at the bus coupler and the supplies U M /U S must be supplied at a separate power terminal. Common Potentials When providing the bus coupler supply separately from the main supply/ segment supply When providing the bus coupler supply by jumpering the main supply/ segment supply Main and segment supply galvanically have the same potential. From the bus coupler onwards, common ground is led through the potential jumper to the devices as the reference ground GND. Bus coupler supply, analog supply, and 7.5 V communications power galvanically have the same potential. From the bus coupler onwards, common ground is led through the potential jumper to the devices as the reference ground LGND. Bus coupler supply, main supply, segment supply, analog supply, and 7.5 V communications power galvanically have the same potential. From the bus coupler onwards, common ground is led through the potential jumper to the devices as reference ground LGND for the communications power and analog supply and separately as reference ground GND for the supply and segment level. 6362_en_03 PHOENIX CONTACT 6

Electrical Isolation/Isolation of the Voltage Areas (Continued) Separate Potentials When providing the bus coupler supply separately from the main supply/ segment supply: When providing the bus coupler supply by jumpering the main/ segment supply: The bus coupler supply is physically and therefore electrically isolated from the main and segment supply. The interface supplies for the incoming and outgoing remote bus are electrically isolated from one another and from the supplies. The bus coupler has two interface supplies for the incoming and outgoing remote bus that are electrically isolated from one another and from the primary/secondary supply. The main supply is electrically isolated from the interface supplies. Electrical Isolation/Isolation of the Voltage Areas Test Distance 5 V supply incoming remote bus / 5 V supply outgoing remote bus 5 V supply incoming remote bus / 7.5 V communications power, analog supply, bus terminal supply 5 V supply incoming remote bus / functional earth ground 5 V supply outgoing remote bus / 7.5 V communications power, analog supply, bus terminal supply 5 V supply outgoing remote bus / functional earth ground 7.5 V communications power, analog supply, bus coupler supply / functional earth ground Test Voltage 500 V AC, 50 Hz, 1 min 500 V AC, 50 Hz, 1 min 500 V AC, 50 Hz, 1 min 500 V AC, 50 Hz, 1 min 500 V AC, 50 Hz, 1 min 500 V AC, 50 Hz, 1 min Approvals For the latest approvals, please visit www.download.phoenixcontact.com. 6362_en_03 PHOENIX CONTACT 7

Local Diagnostic and Status Indicators Remote Bus Connections REMOTE IN REMOTE IN REMOTE IN REMOTE OUT BA UL RD RC LD REMOTE OUT REMOTE OUT DSUB Figure 1 Diagnostic indicators of the terminal 6362A003 Des. Color Meaning UL Green bus coupler supply/ 7.5 V communications power/ interface supply BA Green Bus active RC Green Remote bus cable check RD Yellow Outgoing remote bus switched off LD Yellow Local bus disabled Figure 2 X Y 6 1 7 2 X /DO DO /DI DI Y /DO DO /DI 1 6 1 6 8 reserved reserved 8 3 GND GND 3 5 9 5 9 9 not conn. not conn. 9 4 reserved reserved 4 5 +5 V +5 V 5 Assignment of the remote bus interfaces Remote OUT (outgoing remote bus) Remote IN (incoming remote bus) DI 6 1 7 2 6362B004 6362_en_03 PHOENIX CONTACT 8

Connecting Bus Cables Assemble the D-SUB connectors according to the specifications in the following section. Plug the connectors into the appropriate connections. Secure the connectors using knurled-head screws. Signal /DO DO /DI DI GND Shield (incoming remote bus) Shield (outgoing remote bus) Remark/ Wire Color in the INTERBUS Standard Cable Green Yellow Pink Gray Brown Shield potential is connected with a capacitor to functional earth ground (FE) of the potential jumper. Shield potential is directly connected to functional earth ground (FE) of the potential jumper. 6362_en_03 PHOENIX CONTACT 9

Assembling D-SUB Connectors Type: 9-pos. D-SUB connector, male and female, mechanical protection against polarity reversal Order designation: IBS DSUB 9/L (solder connection), Order No. 2758473 IBS DSUB 9/C (crimp connection), Order No. 2758486 ) % ' &! + + *! +, - $! $ ) ' Figure 3 Assembling D-SUB connectors Strip 20 mm off the cable sheath (A). Shorten the shielding to 8 mm (A). Fold the shielding uniformly back over the sheath (A). Strip 3 mm off the wires. Cut off the white wire (B). Solder the wires to the contacts or crimp them using crimping pliers (C). The contacts of a connector in crimp design must be inserted into the contact housing. To ensure optimum shielding, as much of the shielding as possible must have contact with the shield connection clamp and the mounting base housing. The shield connection clamp also provides strain relief. Place the cables with their contact housing in the slot of the mounting base housing and connect the shielding of the cable with the shield connection clamp by screwing them together (D). Screw the shield connection clamp on tightly using the two countersunk screws. The wires must not be squeezed between the housing parts. Insert the interlocking screws into the drill holes of the contact housing and place them into the guideways of the mounting base housing. Snap the upper part of the housing on the mounting base housing and fasten these parts together using the two socket-head cap screws (E). 6362_en_03 PHOENIX CONTACT 10

Connection of the Bus Coupler Supply 1 2 1.1 1 1 2.1 1.2 2 2 2.2 REMOTE IN 1.3 3 3 2.3 REMOTE OUT 1.4 4 4 2.4 6362A005 Figure 4 Terminal point assignment Terminal Point Assignment Terminal Point Assignment Remark/ Wire Color in the INTERBUS Standard Cable 1.1, 2.1 Reserved 1.2, 2.2 DC U BK bus coupler supply; supply of the bus coupler power supply unit 1.3, 2.3 BK-GND GND GND of the bus coupler supply This potential is reference ground for the bus coupler electronics. 1.4, 2.4 FE Functional earth ground Connection of the bus coupler and therefore of the Inline station to functional earth ground The contacts are directly connected to the potential jumper and the FE spring on the bottom of the housing. Functional earth ground is only used to discharge interference. Ground the bus coupler Connect the bus coupler to functional earth ground via one of the FE connections of the connector. For this, connect the corresponding contact with a grounding terminal (see also Figure 7 on page 14). In addition, the bus coupler is automatically connected to functional earth ground by snapping it onto a grounded DIN rail. Bus Coupler Supply The bus coupler supply is protected against polarity reversal and surge voltage. These protective elements are only used to protect the power supply unit. Ensure short-circuit protection The bus coupler supply does not have short-circuit protection. The user must provide short-circuit protection. The rating of the preconnected fuse must be such that the maximum permissible load current is not exceeded. 6362_en_03 PHOENIX CONTACT 11

Internal Basic Circuit Diagram OPC UL Local bus RS-422 interface 5V 5V 7.5 V BA RD U L U ANA RC LD 5V RS-422 interface Figure 5 Internal wiring of the terminal points 6362C006 D-SUB connector Converter 4 5 " E JA HB=? A Interface component OPC INTERBUS protocol chip (bus logic including voltage conditioning) Optocoupler Diode Power supply unit with electrical isolation LED with function identification Other symbols used are explained in the IB IL SYS PRO UM E user manual. 6362_en_03 PHOENIX CONTACT 12

Electrical Isolation 1 OPC UL Local bus RS-422 interface 5 5V 5V 5 7.5 V BA RD U L+ U ANA U L- 3 RC LD 2 5V RS-422 interface 4 Figure 6 Electrical isolation of individual function areas (separate power supply units) 6362C007 Potential areas when using separate power supply units to supply U BK and U M /U S : 1 Area of incoming remote bus 2 Area of outgoing remote bus 3 Area of functional earth ground (FE, capacitive) 4 Area of functional earth ground (FE) 5 Area of bus coupler supply U BK from which the communications power U L and the analog terminal supply U ANA are generated 6362_en_03 PHOENIX CONTACT 13

Connection Example Information for Using Terminals With Remote Bus Branch Up to 15 terminals with remote bus branch can be installed after the bus coupler. REMOTE IN BA UL RD RC LD DSUB 1 2 1 1 As of hardware revision 02, the IBS IL 24 RB-T terminal with remote bus branch is no longer supplied from the segment circuit but from the analog circuit. This provides various options for supplying the main and segment voltage to the subsequent terminals. REMOTE OUT 2 3 2 3 + - DC (U ) BK The power terminal can be installed before the terminal with remote bus branch. In this case, only a power terminal, which is not a bus device, may be installed. 4 4 The power terminal can be installed after the terminal with remote bus branch. In this case, there are no restrictions. FE 6362B008 Programming Data Figure 7 Typical connection of the cables to the bus coupler Connect the cables according to the information in the "Configuring and Installing the INTERBUS Inline Product Range" user manual. ID code 04 hex (04 dec ) Length code 00 hex Input address area 0 bytes Output address area 0 bytes Parameter channel (PCP) 0 bytes Register length (bus) 0 bytes PHOENIX CONTACT 11/2007 6362_en_03 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 14 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com